Eastern Dedicated Freight Corridor Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Eastern Dedicated Freight Corridor - EDFC Tender
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date29 Jul 2024
Closing Date14 Aug 2024
Tender Amount₹ 1,58,40,053.4
Costs
EMD
₹ 93,500Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Electrical Work In Connection Of Wiring Of 175 Numbers Of Staff Quarters, 01 No Imsd & 01 No Imd At In Khurja-pilkhani Section Of Dfccil Under Cgm/meerut
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DFCC_EL_EW_IMD_IMSD_QRT01-EDFC FIELD UNIT- MEERUT-ADMINISTRATION/EDFCTender No
DFCC_EL_EW_IMD_IMSD_QRT01Tender Authority
Eastern Dedicated Freight Corridor ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for 3/5 pin 6/16 amps plug points with 2.5/4 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked in recessed PVC pipe of ISI marked and MS switch box 4 having wall thickness 16 SWG and fixing 3/5 pin 6/16 Amps socket outlets and 6/16 Amps piano type switch with modular fitting and earthing the 3rd pin with 16 SWG/(2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) Copper earth wire along with pipe duly clamped as required and as per relevant technical specification.
2549
408
1041037.09
Wiring for circuit with 4 sqmm (56/0.3mm) PVC insulated single core unsheathed stranded Copper 5 conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 36 SWG/ (2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and MS switch box for neutral looping etc. as required and as per relevant technical specification. 2*4 sq.mm
19680
146
2875444.8
Wiring for submain with 6 sqmm (84/0.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISImarked and running of 36 SWG/ (2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box as required and as per relevant technical specification.(a) 2 x 6 sq mm .
3814
222
846784.28
Erection, connecting, testing and commissioning of 1Ph energy meter connection with DBs in a Single block as per relevant connections including lugs & other items as required as per relevant technical specifications
52
1639
85260.24
Erection, connecting, testing and commissioning of distribution box as per relevant technical specification including all necessary connections & proper dressing of wire, lugs & other items as required
191
1653
315812.77
Erection & installation of 9 Mtr. Galvanized octagonal pole with base Numbers as per drawing 9 (foundation should be as per design approved by pole manufacturer) GI base plate G.I. anchor plate etc.as required including supplying and fixing of street light fittings with electrical connections with 4x10 Sq.mm Aluminium Armoured XLPE conductors including termination with lugs as required.
60
7265
435935.4
Erection & Installation of Feeder Pillar (foundation should be as per design approved by manufacturer) as required per relevant technical specifications including termination. as required per relevant technical specifications including termination.
7
13048
91339.71
Collecting, Transporting from DFCC store for testing, and commissioning of 4C x10 sq.mm LT Al 11 cable, Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/in wall/in concrete floor by cutting recessed and finished originally as required per relevant technical specifications including termination.
600
367
220428
Collecting, Transporting from DFCC store for testing, and commissioning of 4C x 25 sq.mm LT Al cable, Laying in 100 mm HDPE pipe buried in ground as per relevent specification including termination of cable with lugs & gland.
800
168
135128
Concret & casting M 15/20 grade RCC and FE 415 grade reinforcement as per approved drawing
60
8076
484590.6
Wiring for telephone point with fixing of socket & GI Box as per relevent specification
573
281
161110.41
Wiring of TV points with fixing of socket & GI Box as per relevent specification
573
244
140321.97
Transportation charges & other consumble items i.e tape, screw lugs & other small accessories
1
409531
409531.46
Wiring for light/fan/exhaust fan with 2.5 sqmm (36/.3 mm) PVC insulated single core unsheathed 1 stranded Copper conductor ISI markedrunning of 36 SWG/(2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire a with MS switch box having wallthickness 16 SWG as per relevant technical specification
564
338
190964.76
Erection & testing of light/ceiling fan/exhaust fan & fixing MS box as per relevant technical specification
564
186
105073.2
Wiring for Geyser/AC with 4 sqmm (56/.3 mm) PVC insulated single core unsheathed stranded 3 Copper conductor ISI markedrunning of 36 SWG/(2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire along with MS switch box having wallthickness 16 SWG and socket & switch fixing in modular sheetas per relevant technical specification
4
387
1551.44
Wiring for 3/5 pin 6/16/20 amps plug points with 2.5/4 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked in recessed PVC pipe of ISI marked and MS switch box having wall thickness 16 SWG and fixing 3/5 pin 5/15 Amps socketoutlets and 5/15 Amps piano type switch and earthing the 3rd pin with 16 SWG/(2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) Copper earth wire along with pipe duly clamped as required and as per relevant technical specification.
338
408
138042.58
Wiring for circuit with 4 sqmm (56/0.3mm) PVC insulated single core unsheathed stranded Copper 5 conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 36 SWG/ (2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and MS switch box for neutral looping etc. as required and as per relevant technical specification. 2*4 sq.mm
16400
146
2396040
Wiring for submain with 6 sqmm (84/0.3 mm) PVC insulated single core unsheathed stranded 6 Copper conductor ISI marked cable in recessed PVC pipe of ISImarked and running of 36 SWG/ (2.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box as required and as per relevant technical specification.(a) 2 x 6 sq mm .
4000
222
888080
Erection, connecting, testing and commissioning of Sub distribution box as per relevant technical specification including all necessary connections & proper dressing of wire, lugs & other items as required
25
1525
38142.5
Erection & installation of 9 Mtr. Galvanized octagonal pole with base Numbers as per drawing 8 (foundation should be as per design approved by pole manufacturer) GI base plate G.I. anchor plate etc.as required including supplying and fixing of street light fittings with electrical connections with 4x10 Sq.mm Aluminium Armoured XLPE conductor sincluding termination with lugs as required.
51
7280
371312.13
Erection & Installation of main distribution panel (foundation should be as per design approved by manufacturer) as required per relevant technical specifications including termination. as required per relevant technical specifications including termination.
7
13075
91527.31
Collecting, Transporting from DFCC store for testing, and commissioning of 4C x10/25 sq.mm LT 10 Al cable, Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/in wall/in concrete floor by cutting recessed and finished originally as required per relevant technical specifications including termination.
1200
367
440856
Collecting, Transporting from DFCC store for testing, and commissioning of 4C x 95 sq.mm LT Al 11 cable, Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/in wall/in concrete floor by cutting recessed and finished originally as required per relevant technical specifications including termination.
150
615
92329.5
Concret & casting M 15/20 grade RCC and FE 415 grade reinforcement as per approved drawing
50
7958
397905.5
Erection & installation of RO with water cooler inlcuding socket & pipe fitting as required
2
2213
4426.66
Erection & installation of 82.5 KVA DG set with casting foundation concret grade M15/20 including cable termination, earthing & exhaust fan
1
52033
52033.33
Erection & installation of 20 KVA UPS with cable termination with lugs, connection & input & output panel
1
5933
5933.33
erection & testing of earth electrode conventional & maintenance free with all civil work
35
4938
172841.55
Laying of GI earth flat 20x3, 25x4 & 50x6 including fixing of fasteners
1180
105
124289.4
Fixing & testing for Automation of water pump
2
1520
3040
Erection & installation of 2/5 KW solar panel including wiring, connection & its DCDB box & its other accessories with foundation & other Civil work
2
20265
40530
Erection & installation of fire detection & alram system with control panels wiring , connection & other its accessories.
2
291650
583300
Erection & testing installation of 1.5/2 ton split AC including accessories
17
2206
37513.22
Transportation charges & other consumble items i.e tape, screw lugs & other small accessories
1
308791
308791.9
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements