East Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

East Central Railway - ECR Tender

Works
Civil And Construction
Building Construction
Ireps
Opening Date13 Dec 2024
Closing Soon13 Jan 2025
Tender Amount₹ 87,95,912.38 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
FLOORING // CERAMIC GLAZED TILES // Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of 2 approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

403

938

291225.93

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Polished Granite stoneflooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. // Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent

421

3908

1267115.7

... More
FLOORING // TILE FLOORING // Chequerred precast cement concrete tiles 22 mm 4 thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). // Light shade pigment using white cement

60

1233

56966.91

... More
CLADDING WORK // STONE WORK DRY CLADDING // Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer 5 rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

260

4474

895734.84

... More
DISMANTLING AND DEMOLISHING // Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. // For thickness of tiles 10 mm to 25 mm

429

60

19984.97

... More
DISMANTLING AND DEMOLISHING // Disposal of building rubbish / malba / similar 7 unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

7

219

1182.3

... More
FINISHING // CEMENT PLASTER (IN COARSE SAND) // 15 mm cement plaster on rough side of single or half brick wall of mix: // 1:4 (1 cement: 4 coarse sand)

476

354

129931.34

... More
FINISHING // CEMENT PLASTER (IN COARSE SAND) // 15 mm cement plaster on rough side of single or half brick wall of mix: // 1:6 (1 cement: 6 coarse sand)

390

339

101831.73

... More
FINISHING // CEMENT PLASTER (IN COARSE SAND) // 12 mm cement plaster of mix : // 1:4 (1 cement: 4 coarse sand)

130

307

30755.72

... More
MASONRY WORK // HALF BRICK MASONRY // Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : // cement mortar 1:4 (1 cement : 4 coarse sand)

13

837

8386.88

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : // Cement mortar 1:4 (1 cement : 4 coarse sand) 6.1.1 20.00 cum 6882.00 137640.00 (-) 23.00 105982.80

4

8512

26217.27

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: // Cement mortar 1:4 (1 cement : 4 coarse sand)

-

-

13

... More
MASONRY WORK // Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : // With F.P.S.(non modular) bricks

33

8030

204057.55

... More
FLOORING // Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with local sand, with common burnt clay non modular bricks.

13

733

7340.33

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in 16 position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

4

7783

23973.64

... More
REINFORCED CEMENT CONCRETE // DESIGN MIX CONCRETE // Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing 17 strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. // All works above plinth level upto floor V level // Concrete of M25 grade with minimum cement content of 330 kg /cum

22

10306

174587.03

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. // Hot rolled deformed bars

3000

89

207091.5

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

9

669

4639.98

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Lintels, beams, plinth beams, girders, bressumers and cantilevers

39

608

18268.75

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Suspended floors, roofs, landings, balconies and access platform

104

766

61385.32

... More
DISMANTLING AND DEMOLISHING // Demolishing R.C.C. work by mechanical 22 means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.

2.5

2328

4482.46

... More
ROOFING // CEILING // Providing 10 mm thick plaster of Paris (gypsum anhydrous) 23 ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): // Flat surfaces

200

1421

218872.5

... More
DISMANTLING AND DEMOLISHING // Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

400

219

67683

... More
FLOORING // Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. // 40 mm thick with 20 mm nominal size stone aggregate 15.2.1 1.00 cum 2007.10 2007.10 (-) 23.00 1545.47

120

545

50358

... More
DISMANTLING AND DEMOLISHING // Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. // Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

-

-

26

... More
FINISHING // Applying priming coats with primer of approved brand and manufacture, 27 having low VOC (Volatile Organic Compound ) content. // Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specification. // One or more coats on old work

9300

50

362346.6

... More
FINISHING // Applying priming coats with primer of approved brand and manufacture, 28 having low VOC (Volatile Organic Compound ) content. // Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : // One or more coats on old work

1040

86

69309.24

... More
FINISHING // Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. // Two or more coats on new work

500

92

35708.75

... More
FINISHING // Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. // White washing with lime to give an even shade : // Old work (two or more coats)

2200

19

32186

... More
FINISHING // Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. // Finishing walls with water proofing cement paint of required shade : // Old work (one or more coats @ 2.20 kg/10 sqm) complete.

8380

63

408126.95

... More
FINISHING // EXTERIOR FINISHING // Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. // On concrete work

30

198

4583.04

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of 33 extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer- in-Charge.

60

408

18861.15

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on 34 the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. // 30 mm thick pre laminated PVC door shutters

24

2455

45370.25

... More
WOOD AND P.V.C. WORK // Providing and fixing 25 mm thick shutters for cup board 35 etc. : // Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. // 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

20

3086

47525.94

... More
WOOD AND P.V.C. WORK // FRAMES AND TRUSSES // Providing wood work in frames 36 of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). // Kiln seasoned and chemically treated hollock wood

3

74199

171401.31

... More
WOOD AND P.V.C. WORK // Providing and fixing 25 mm thick shutters for cup board 37 etc. : // Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: // 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

93

2015

144347.86

... More
WOOD AND P.V.C. WORK // Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both 38 directions for doors, windows and clerestory windows with necessary screws : // Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. // With 2nd class teak wood beading 62X19 mm

33

1404

35681.99

... More
DISMANTLING AND DEMOLISHING // Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : // Of area 3 sq. metres and below

33

302

7691.61

... More
DISMANTLING AND DEMOLISHING // Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : // Of area 3 sq. metres and below

15

118

1366.37

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and 41 sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // For fixed portion // Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

210

433

70169.71

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, 42 straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) // Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

110

531

45043.46

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, 43 straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): // With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

75

1019

58893.45

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, 44 ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. // Pre-laminated particle board with decorative lamination on both sides

90

951

65907.76

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS 45 designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). // 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.

225

936

162283.27

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Providing 46 and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : // Precoated/mill finish aluminium Ridges plain (500- 600mm)

60

969

44790.9

... More
STEEL WORK // Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

100

111

8620.15

... More
ROOFING // SHEET ROOFING // Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. // 0.80 mm thick with zinc coating not less than 275 gm/sqm

110

822

69636.1

... More
REPAIRS TO BUILDING // ROUTINE MAINTENANCE WORK // Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25 degrees celsius, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of 49 membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23 degrees celsius as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150 degrees celsius. Cold flexibility shall be upto -2 degrees celsius when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : // 3 mm thick

450

563

195252.75

... More
FINISHING // Painting with aluminium paint of approved brand and manufacture to give an even shade . // Two or more coats on new work

450

121

42082.43

... More
WATER PROOFING // Grading roof for water proofing treatment with // Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

6

7510

34699.67

... More
FINISHING // CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT // Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. // 20 mm cement plaster

85

507

33238.78

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.-Internal work - Exposed on wall // 15 mm dia nominal bore

180

304

42155.19

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.-External work // 25 mm dia nominal bore

225

417

72409.84

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.-External work // 40 mm dia nominal bore

90

558

38693.65

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.-External work // 50 mm dia nominal bore

160

654

80597.44

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : // 15 mm nominal bore

30

262

6059.13

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : // 25 mm nominal bore

45

369

12797.98

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and 59 fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : // 40 mm nominal bore

15

943

10900.89

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and 60 fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : // 50 mm nominal bore

60

1280

59149.86

... More
DISMANTLING AND DEMOLISHING // Dismantling G.I. pipes (external work) 61 including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : // 15 mm to 40 mm nominal bore

150

124

14333.55

... More
DISMANTLING AND DEMOLISHING // Dismantling G.I. pipes (external work) 62 including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : // Above 40 mm nominal bore

180

134

18607.05

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and 63 placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

6000

9

44814

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : // 25 mm nominal bore

15

399

4610.18

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing brass stop cock of approved quality : // 15 mm nominal bore

23

303

5381.18

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : // 25 mm nominal bore

23

532

9427.92

... More
SANITARY INSTALLATIONS // Providing and fixing white vitreous china pedestal 67 type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : // W.C. pan with ISI marked white solid plastic seat and lid 17.10.2.2 5.00 Each 3337.85 16689.25 (-) 23.00 12850.72

8

5540

34129.79

... More
SANITARY INSTALLATIONS // Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : // Kitchen sink without drain board // 610x460 mm bowl depth 200 mm

-

-

68

... More
SANITARY INSTALLATIONS // Providing and fixing wash basin with C.I. brackets, 15 69 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: // White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

16

1679

20692.67

... More
SANITARY INSTALLATIONS // Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

10

1411

10865.85

... More
SANITARY INSTALLATIONS // Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia

9

6119

42405.71

... More
SANITARY INSTALLATIONS // Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic 72 flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : // Single squatting plate with 5 litre P.V.C. automatic flushing cistern

2

7752

11939

... More
SANITARY INSTALLATIONS // Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, 73 including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: // White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

18

5781

80129.51

... More
SANITARY INSTALLATIONS // Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes 74 respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : // One urinal basin with 5 litre white P.V.C. automatic flushing cistern

14

5268

56798.2

... More
EARTH WORK // Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

3

2161

4992.37

... More
REPAIRS TO BUILDING // ROUTINE MAINTENANCE WORK // Cutting holes of required 76 size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in- charge.

3

243

561.56

... More
ROOFING // Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of 77 masonry (lead caulking will be paid for separately): // Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. // 110 mm diameter

33

319

8124.85

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ 78 accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Bend 87.5 degrees // 110 mm bend

6

132

609.84

... More
SANITARY INSTALLATIONS // Providing and fixing soil, waste and vent pipes : // 100 mm dia // Sand cast iron S&S pipe as per IS: 1729

190

1018

148940.71

... More
SANITARY INSTALLATIONS // Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : // 100 mm dia pipe 17.39.1.1 50.00 Each 412.95 20647.50 (-) 23.00 15898.58

115

163

14473.5

... More
SANITARY INSTALLATIONS // Providing and fixing plain bend of required degree. // 100 mm dia // Sand cast iron S&S as per IS - 1729

-

-

81

... More
SANITARY INSTALLATIONS // Providing and fixing single equal plain junction of required degree : // 100x100x100 mm // Sand cast iron S&S as per IS - 1729

30

580

13402.62

... More
REPAIRS TO BUILDING // ROUTINE MAINTENANCE WORK // Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i)Tank shall be 83 emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.

2000

71

109802

... More
REPAIRS TO BUILDING // ROUTINE MAINTENANCE WORK // Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting 84 with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)

5900

-

1817.2

... More
ROAD WORK // MISCELLANEOUS // Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in 85 required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. // 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

105

1011

81755.52

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame 86 & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).

20

10030

154466.62

... More
WOOD AND P.V.C. WORK // Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : // Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

20

7249

111648.46

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, 88 straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): // With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

10

1325

10206.74



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.