If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Dr Ram Manohar Lohia Institute Of Medical Sciences - RMLIMS Tender

Works
Electrical and Electronics
Eprocure
Opening Date28 Jun 2024
Closing Date11 Jul 2024
Tender Amount₹ 41,88,194 
Notes
Download

Costs

Summary

Supply, Installation ,testing And Commissioning Of Vrv Vrf Air Conditioning System With Ahu In Emergency Of Old Hospital Block

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Supply, installation ,testing and commissioning of VRV VRF Air conditioning system with AHU in Emergency of Old Hospital Block at Dr RMLIMS
Format of Financial bid
Tender document with specification, terms and conditions etc.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
20.0 HP capacity aircooled outdoor unit

2

-

-

... More
Supply and installation of 20 HP Capacity AHU Kit having electronic expansion valve, controller and wire remote compatible with AHU to be installed under this work.

2

-

-

... More
Air Handling Units:

-

-

-

... More
Supply,installation,testing & commissioning of following capacity factory fabricated, double skin, horizontly mounted Air Handling Unit made out of pre coated GI sheet with CFC free PUF injected insulation of thickness 23+/- 2 mm of density 40+/-2 Kg/Cu.Mtr, thermal break, mixing chamber , fresh air arrangement and weather proof canopy and AHU shall be suitable for outdoor application. The AHU shall have filter section fitted with 50 mm thick with non woven filter media suitable for 10 micron filtration.The AHU shall have four rows of deep interwined air cooled type copper cooling coils with aluminium fins, distributor and insulated SS-304 drain pan. The fan section of the AHU shall be fitted with DIDW centrifugal backward curved blower fan, Sq-cage induction motor ,V belt and drive set. The operating voltage of AHU shall be 415V, 3 phase, 50 hertz and it shall have electrical control panel fitted with all suitable starter,door limit switch with LED lamp inside AHU, motorized damper,actuator and control panel for supply outlet, control relays & switch gear of required current rating complete with electrical & control wiring complete with piping connection, making of required size p.c.c pedestal for installing the AHU etc complete work as required to make the VRV system fully functional. Make of AHU: Zeco/Edgetech/System Air/Carryaire. The capacity of new AHUs to be installed are as given below:

-

-

-

... More
AHU 16.0 TR, 5600 CFM with S.P. of 45 MMWG complete with all accessories.

2

-

-

... More
Supplying, Installation and of interconnection of following sizes of copper pipe work insulated with closed cell electromeric nitrile rubber tubular insultation between each set of AHU & outdoor units, all piping shall be properly fixed/supported with suitable size of clamp/M.S. hanger and all piping shall run on cable tray complete work as reqd.The final size of refrigerant pipe shall be as per VRV/VRF plant manufacturer's guidelines/recommendations. Make: Copper tube: Mexflo/Mandev or equivalent. Insulation: A flex/K flex/Armaflex or equivalent.

-

-

-

... More
22.2 mm to 28.6 mm dia with 19mm thick insulation

40

-

-

... More
12.7 mm to 15.88 mm dia with 13mm thick insulation

40

-

-

... More
Providing fabricating and installation of following size of perforated M.S. Painted Cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders including painting etc. complete work as required as per site requirement.

-

-

-

... More
200mm x 50mm x 1.6mm thickness

40

-

-

... More
Providing,fixing and connecting of Hard PVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation.

-

-

-

... More
50 mm dia

20

-

-

... More
Supply, laying & fixing of site fabricated 24G thick GSS Sheet metal for covering of cable tray for outside condition complete work as required.

25

-

-

... More
Supply, Fabrication, installation, testing and commissioning of Hand Fabricated GSS sheet metal rectangular ducting (as per SMACNA standard) complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specifications, requirement, standardard and drawings. Make: GSS sheet : SAIL/Jindal/Tata.

-

-

-

... More
20 G (1.0 mm thick) (Plenum Box)

40

-

-

... More
22 G (0.8 mm thick)

140

-

-

... More
24 G (0.63 mm thick)

220

-

-

... More
Supply and fixing of Thermal insulation of the supply/return air ducts with class O XLPE insulation of following sizes. Make:- Supreme/K FLEX/Paramount/Vidoflex.

-

-

-

... More
16 mm thick (Supply and retrurn air inside building)

230

-

-

... More
35 mm (16+ 19) thick with aluminium foil on outer side (Supply and retrurn air out side building including Plenum Box)

180

-

-

... More
Supply & fixing of accoustic Lining of 10 mm thick open cell nitrile insulation. Make:- Supreme/K FLEX/Paramount/Vidoflex/Equivalent

40

-

-

... More
Supply and installation of Extruded Aluminium Powder coated Supply/Return air grills of required size. Make:- Systemair/Airmaster/Airflow/Opella

9

-

-

... More
Supply and installation of G.I. damper for supply air Main Duct. Make:- Systemair/Airmaster/Airflow/Opella

2

-

-

... More
Supply and installation of Alluminium collar damper for supply air. Make:- Systemair/Airmaster/Airflow/Opella

3.5

-

-

... More
Supply and fixing of water proof and fire retardent Canvass Connection for connecting indoor with duct.

4

-

-

... More
Supply, installation ,testing & commissiioning of weatherproof Box for ELCB for out door and AHU complete in all respect as required.

4

-

-

... More
Supply and fixing ELCB for following rating units .

-

-

-

... More
32 amps, 4 pole, 415V, AC

2

-

-

... More
63 amps, 4 pole, 415V, AC

2

-

-

... More
Supply, Installation, testing & commissioning of LT electrical Panel made out of CRCA sheet 1.6 mm thick for AC Plant duly compartmentalised having suitable incomer of 150 Amp MCCB, Alluminium Bus Bar, suitable out going having 02 nos. of 63 Amp TP MCB for out door units and 2 nos of 32 Amp MCB for AHU complete with push button, indicating lamp, metering devices complete in all respect.

1

-

-

... More
Supply, laying and termination of following sizes XLPE/PVC insulated Copper and alluminium cable, overall PVC sheathed 1.1 KV grade conductor cables conforming to relevant IS code and technical specifications. Make – Havells , Gloster, Rallison,SBEE, Finolex, Polycab, Dynamic Cables.

-

-

-

... More
4 Core x 6 sq.mm. Copper Cable Flexible

120

-

-

... More
4 Core x 16 sq.mm. Copper Cable Flexible.

120

-

-

... More
3.5 core x 70.0 sq.mm .Al. Armoured

80

-

-

... More
Supply and fixing of brass/nickel plated compression gland for PVC insulated & armoured served sheathed , underground cables including rubber ring etc. Complete in all respect, The armouring of the cable shall be properly connected with the earth.

-

-

-

... More
4C x 6 sq.mm

4

-

-

... More
4C x 16 sq.mm

4

-

-

... More
3.5C x 70 sq.mm

2

-

-

... More
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect.

-

-

-

... More
6.0 sqmm

16

800

50

... More
10.0 sqmm

16

-

-

... More
70.0 sqmm

8

-

-

... More
Supply, Installation, testing & commissioning of control cable having copper conductor wire between indoor and outdoor units in PVC Conduit, Make – Havells , Gloster, Rallison,SBEE, Finolex, Polycab, Dynamic Cables.

-

-

-

... More
2 core x 1.5sqmm copper conductor

200

-

-

... More
Supply and laying of 8 SWG G.I. Earth Wire for earthing.

220

-

-

... More
Supply and Fixing of MS angle stand for VRF Out door unit.

2

-

-

... More
Supply, making and fixing of Gypsum Boxing of required size to cover the Supply & Return air conditioning Ducts laid under neath the tin shed using good quality G.I. Channel and Gypsum board including its painting and other accessories as required to complete the boxing work.

120

-

-

... More
Minor Civil Work such as making of all wall openings for laying the ducts and pipes and closing /repair of all such openings to make it leak proof with suitable tools to minimise the damage in existing interrior.

1

-

-

... More
Total Sub Head-I without GST

-

-

-

... More
Labour Cess @1%

-

-

-

... More
GST @18%

-

-

-

... More
Total Sub Head-I with GST & labour Cess

-

-

-

... More
Description

-

-

-

... More
Sub Head-II

-

-

-

... More
Comprehensive AMC of VRV/VRF air conditioning system including all other associated items as mentioned & installed under Sub Head-I of this work including charging of refrigerant gas and all other spares required to keep this VRV/VRF A/C plant all the time fully functional including its switchgears,control cabling etc complete work as required for the following period after completion of completion of defect liabilty period of one :

-

-

-

... More
Comprehensive AMC for Ist twelve months period after expiry of defect liability period of one year.

12

-

-

... More
Comprehensive AMC for 2nd year- twelve month period.

12

-

-

... More
Comprehensive AMC for 3rd year- twelve month period.

12

-

-

... More
Total Sub Head-II without GST

-

-

-

... More
Labour Cess @1%

-

-

-

... More
Add GST@ 18%

-

-

-

... More
Total Sub Head-II with GST & labour Cess

-

-

-

... More
Grand Total: Total Sub Head-I with GST + Total Sub Head- II with GST)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.