Dr Ram Manohar Lohia Institute Of Medical Sciences Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dr Ram Manohar Lohia Institute Of Medical Sciences - RMLIMS Tender
Electrical and Electronics
Eprocure
Opening Date30 Dec 2023
Closing Date12 Jan 2024
Tender Amount₹ 30,32,126
Costs
EMD
₹ 60,645Document Cost
₹ 1,180Tender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning Of Ceiling Suspended Ductable Vrv Vrf Air Conditioning System In Mri Section Of Old Hospital Block
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_RMLIM_875773_1Tender No
3008/DrRMLIMS/Electrical/2023Tender Authority
Dr Ram Manohar Lohia Institute Of Medical Sciences ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning of ceiling suspended Ductable VRV VRF Air conditioning system in MRI Section of Old Hospital Block.
BOQ Items
22.0 HP capacity, Heat pump type outdoor unit comprising of 02 Nos. of Scroll compressor.
2
-
-
Indoor Units
-
-
-
Supply, installation, testing and commissioning of ceiling suspended ductable split indoor units with pre filter, fan section, copper coil section , outer GI cabinet , insulated drain pan, pipe & duct connections etc of various capacities along with supply & installation of corded remote for operating the indoor unit complete work as required. . Make of Indoor Unit shall be same as Item No.1.
-
-
-
5.5 TR
2
-
-
11 TR
2
-
-
Supply, installation, testing and commissioning of three star rated inverter type hi wall split air conditioner including five Rmt additional copper pipes, drain pipe,electrical cable & out door stand,stablizer etc complete work as required. Make: LG/Mitsubhishi/O General/Voltas/
Blue Star/Carrier/Hitachi/Toshiba/Samsung.
-
-
-
2.0 TR Nominal capacity
2
-
-
Supply and Fixing of copper Y-joints/Refnuts of required sizes as per capacity of indoor units.Make same as Item Sl No.1.
2
-
-
Supplying, Installation and of interconnection of following sizes of one end expanded refrigerant copper piping with Y-Joint and Headers of following outer diameter , insulated with closed cell electrometric nitrile rubber tubular insultation between each set of indoor & outdoor units, all piping inside the room shall be properly fixed/supported with suitable size of clamp/M.S. hanger and all external piping shall run on existing GSS cable tray etc. complete work as reqd.The final size of refrigerant pipe line shall be as per VRV/VRF plant manufacturer's guidelines/recommendations.
Make: Copper pipe: Rajco/MaxflowMandev/Met tube. Nitrile insulation: A Flex/Kflex/Aeroflex/Armaflex/Insyflex.
-
-
-
31.8 mm dia with 19mm thick insulation
30
-
-
28.6 mm dia with 19mm thick insulation
72
-
-
22.2mm dia with 19mm thick insulation
2
-
-
19.1mm dia with 13mm thick insulation
36
-
-
15.9mm dia with 13mm thick insulation
46
-
-
12.7mm dia with 13mm thick insulation
46
-
-
9.5mm dia with 13mm thick insulation
2
-
-
6.35mm dia with 13mm thick insulation
2
-
-
Providing fabricating and installation of following size of perforated G.I. Cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. threaded suspenders including painting etc. complete work as required as per site requirement.
-
-
-
300m x 50mm x 1.6mm thickness DSR 2018 S.No 4.1.4
15
-
-
200mm x 50mm x 1.6mm thickness DSR 2018 S.No. 4.1.3
18
-
-
Providing,fixing and connecting of UPVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation.Make: PVC drain pipe:Supreme/Astral/Kisan/Prince.
-
-
-
40 mm dia
20
-
-
50 mm dia
18
-
-
Supply, laying & fixing of site fabricated 24G thick GSS Sheet metal for covering of cable tray for outside condition complete work as required.Make: Jindal/TATA/SAIL.
10
-
-
Supply, fabrication,installation of following gauge aluminium sheet duct of required size as per site requirement along with hangers & all accessories etc as required with sealing gasket for supply air duct etc complete work as required.Make of Al. sheet: Hindalco/Balco or equvalent approved.
-
-
-
20G
25
-
-
18G
45
-
-
Supply & fixing of Thermal insulation on supply & return air duct of following thickness complete work as required.
Make: Supreme/K flex/Paramount/Vidoflex..
-
-
-
12 mm
50
-
-
Supply & fixing of 9 mm thick open cell nitrile insulation accoustic lining in plenum chamber.Make: Supreme/K flex/Paramount/Vidoflex..
30
-
-
Supply & installation of extruded aluminium powder coated supply & return air grill of required sizes as per site requirement.Make: Systemair/Airmaster/ Airflow/Opella.
4.5
-
-
Supply & installation of GI aluminium coller damper for main duct supply air complete work as required. Make: Systemair/Airmaster/Airflow/Opella.
2
-
-
Supply & installation of GI duct for supply air complete work as required.
Make: Systemair/Airmaster/Airflow/Opella.
2
-
-
Supply and fixing of water proof & fire retardent canvass connection for for connecting indoorunit with ducts complete work as required.
4
-
-
Supply, fixing, testing & commissioning of motorized duct damper with actuator ,sensor & control panel for supply air including wiring complete work in all respect as required. The opening & closing of supply air damper shall be interlocked with indoor blower motor. Make: Seimens/Honeywell/Belimo.
4
-
-
Supply & fixing of M S powder coated weather proof outdoor MCB cover box for providing 415V,AC power supply to outdoor unit .
2
-
-
Supply, installation , testing & commissioning of following rating MCCB for controlling power supply to outdoor units complete with connection etc as required.
-
-
-
63 Amp, 4 pole , 415V,AC
4
-
-
Supply,installation,testing & commissioning of 415V,AC rating LT electrical panel consisting of 4 strip aluminium busbar of 150 Amp currenet rating , made out of 1.6 mm thick mild steel CRCA sheet duly powder coated duly comparmentalized having one incomer of 150 Amp rating 4P,MCCB and 02 Nos. of outgoing of 125Amp, 3P, MCCB & 02 Nos. of 16 Amp rating SP, MCB for indoor units complete with panel indicating lamps,volt meter, ammeter,selector switches, push button and earth bar etc complete in all respect as required. The panel shall comply to the specifications as per relvant IS.
1
-
-
Supply, laying and termination of following sizes XLPE/PVC insulated Copper cable, overall PVC sheathed 1.1 KV grade conductor cables conforming to relevant IS code and technical specifications. Make – Havells/ Gloster/ Rallison/ Finolex/Polycab.
-
-
-
4Core X 25sq.mm. Copper conductor Armoured.
40
-
-
3Core x 2.5sq.mm. PVC insulated copper conductor cable
100
-
-
3.5 core x 50.0 sq.mm . Aluminium conductor ,PVC insulated /XLPE armoured power cable.
40
-
-
Supply and fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed , underground cables including rubber ring etc. Complete in all respect, The armouring of the cable shall be properly connected with the earth as per direction of Engineer. Incharge.
-
-
-
4C x 25 sq.mm
4
-
-
3.5C x 50.0 sq.mm
2
-
-
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect as per direction of Engineer – Incharge.
-
-
-
25 sqmm
16
-
-
50 sqmm
8
-
-
2.5 sqmm
24
-
-
Supply, Installation, testing & commissioning of control cum trans-mission wiring with screened copper conductor wire between indoor and outdoor units in PVC Conduit, Make – Havells/Gloster/Rallison/SBEE/ Finolex/Polycab.
-
-
-
2 core x 1.5sqmm copper conductor
100
-
-
Supply and laying of 25mmx5mm size GI earthing from main electrical panel to local electrical panel complet with all accessories as required.
100
-
-
Supply,installation,testing & commissioning of heating system for controlling humidity in winter season comprising of following capacity strip heaters with desired rating geysestats,thermostat, humidistat and controller etc complete system in all respect as required.
-
-
-
9KW(3KWx3)
2
-
-
Total Sub Head-I (Total from Item No.1 to 24)
-
-
-
Add GST
-
-
-
Total Sub Head-I with GST
-
-
-
Sub Head-II
-
-
-
Comprehensive AMC of ductable VRV/VRF air conditioning system of given capacity including all other associated equipments items & accessories as mentioned & installed under Sub Head-I of this work including charging of refrigerant gas and all othe spares required to keep this ductable VRV/VRF A/C plant all the time fully functional including its switchgears, power cables, control cabling etc complete work as required for the following period after completion of defect liabilty period of one year :
-
-
-
Comprehensive AMC for Ist twelve months (Ist one year)period after expiry of defect liability
periodof one year.
12
-
-
Comprehensive AMC for Iind twelve month (2nd one year) period after expiry of defect liabilty period of one year.
12
-
-
Comprehensive AMC for IIIrd twelve month (3rd one year ) period after expiry of defect liability period of one year.
12
-
-
Total Sub Head-II without GST
-
-
-
Add GST
-
-
-
Total Sub Head-II with GST
-
-
-
Grand Total with GST: (Sub Head-I + Sub Head- II)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements