Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Directorate Of Medical Education And Training

Kanpur, Uttar Pradesh

  • Opening Date

    16 Aug 2019

  • Closing Date

    14 Sep 2019

  • Tender Amount

    ₹ 49,50,000

  • EMD

    ₹ 49,500

Are you Looking for Joint Venture Partners, Contractor Consortium, Back-to-Back Contractor, Project Financier?
We will help you to find the right match for FREE.
Summary

Ultrasound Scanning Machine

Don't have sufficient eligibility, BG funds or resources?
We will help you to find the right match for FREE.
BOQ Items

No BOQs Available

Bid Number: GEM/2019/B/322821 Dated: 16-08-2019 Bid Document Bid Details Bid End Date/Time 31-08-2019 17:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 30 (Days) Ministry/State Name Uttar Pradesh Department Name Medical Education Department Uttar Pradesh Organisation Name Directorate Of Medical Education And Training Office Name Director General Medical Education Total Quantity 1 Item Category Ultrasound Scanning Machine Average Turnover (Last 3 Years) 25 Lakh (s) MSE Exemption For Years Of Experience And Turnover No Startup Exemption For Years Of Experience And Turnover No Document required from seller Experience with Government,Annual Turnover,OEM Authorization Certificate Bid to RA enabled No Ultrasound Scanning Machine ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Product certification Both EU CE (With verified number) and US FDA Both EU CE (With verified number) and US FDA Certification number and date - * Confirmity to Manufacturer's Certification ISO 9001 & ISO 13485 ISO 9001 & ISO 13485 1 / 9 Confirmity to Performance and safety standards specific to the device IEC 60601-2-37 or equivalent BIS * Performance Parameters Scope of supply General-purpose ultrasonic scanning systems provide two- dimensional (2-D) B- mode images of soft tissues without subjecting patients to ionizing radiation. It intends to primarily for abdominal, obstetric/gynecologic (OB/GYN), small-parts, and vascular imaging * UMDNS Code and names(Hint: This is for indicating the relevant universal medical devices nomenclature for the category of product ) "Scanning Systems, Ultrasonic, Abdominal [16-241] Scanning Systems, Ultrasonic, General-Purpose [15-976] Scanning Systems, Ultrasonic, Obstetric/Gynecologic [15-657] Scanning Systems, Ultrasonic, Small-Parts [18-052] Scanning Systems, Ultrasonic, Vascular [15-957]" * Types of Probes & Features Applications- Abdomen, abdominal vascular, urology, OB/GYN, neonatal brain, small parts (breast, thyroid, scrotal, prostate, MSK) Yes * Flat linear array 5-10 MHz (±2) * Convex array 2.5-5 MHz (±2) * Microconvex array Yes * Volume Convex Probe No Yes, No Volume Linear Probe No Yes, No Volume TV Probe No No E- Breast Elastography Yes Yes E- Thyroid Elastography Yes Yes Liver Elastography Yes Yes Intraoperative Probe No Yes, No 2 / 9 Gel Warmer No Yes, No Dedicated 3-D/4-D No Yes, No Scan Modes B-mode Yes * M-mode Yes * Contrast harmonic imaging with angio mode No Yes, No Tissue harmonic imaging mode Yes * Provision of Harmonic imaging in Linear Probes Yes * Color Doppler imaging (CDI) Yes * Color Doppler 3-D/4-D option Yes * Power Doppler imaging (PDI) Yes * Power Doppler 3-D/4-D option Yes * Continuous wave Yes * Pulsed wave Yes * Duplex mode Yes * Triplex mode Yes * Tissue Doppler imaging Yes * Contrast-enhanced ultrasound (CEUS) option No Yes, No Tissue synchronization, tissue velocity Yes Yes Gain control in two dimensions for additional level of flexibility for image quality control Yes * "Provision for higher resolution " Real time high frequency 2D * Probes supplied shall be in latest generation bandwidth Yes * Provision for higher sensitivity for low frequency doppler in all probes Yes Yes 3 / 9 Number of Channels in color doppler system 50000 or more (If channels are being designated as digital channels) 50000 or more (If channels are being designated as digital channels) Live 3 D imaging in color doppler system No Yes, No Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval No Yes, No Number of grey shades for sharp contrast resolutions in db 256 or more * High-definition acoustic

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.