If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Directorate General Of Medical Education And Training - DGME Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Aug 2024
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 1,00,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Electrical Maintenance And Item Supply Work
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DGMET_949871_1Tender No
400 Date 23-08-2024Tender Authority
Directorate General Of Medical Education And Training ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
630 KVA Transformer repairing &binding& installation (All Requirement)
1
-
-
500 KVA Transformer repairing &binding& installation (All Requirement)
1
-
-
Complete Maintenance 1250 KVA Transformer (Items that need to be checked yearly) a) Oil in the transformer (this time check the acidity resistivity, tan delta and sludge. It may need to be filtered or replaced entirely)
1
-
-
b) Check the Buchholz relay function completely.
1
-
-
c) Oil-filled condenser bushing
1
-
-
d) Gasket joints (may need to be tightened to avoid uneven pressure)
1
-
-
e) Check the transformer marshalling box
1
-
-
f) Relays alarm and other circuits
1
-
-
g) Transformer body clear& Paintwork
1
-
-
h) Transformer Earthing test
1
-
-
i) Transformer insulation resistance test
1
-
-
j) All power& control terminal tightness and overheating check
1
-
-
Complete Maintenance 630 KVA Transformer (Items that need to be checked yearly)
1
-
-
a) Oil in the transformer (this time check the acidity resistivity, tan delta and sludge. It may need to be filtered or replaced entirely)
1
-
-
b) Check the Buchholz relay function completely.
1
-
-
c) Oil-filled condenser bushing
1
-
-
d) Gasket joints (may need to be tightened to avoid uneven pressure)
1
-
-
e) Check the transformer marshalling box.
1
-
-
f) Relays alarm and other circuits
1
-
-
g) Transformer body clear& Paintwork.
1
-
-
h) Transformer Earthing test.
1
-
-
i) Transformer insulation resistance test.
1
-
-
j) All power& control terminal tightness and overheating check
1
-
-
Complete Maintenance 500 KVA Transformer (Items that need to be checked yearly) a) Oil in the transformer (this time check the acidity resistivity, tan delta and sludge. It may need to be filtered or replaced entirely)
1
-
-
b) Check the Buchholz relay function completely.
1
-
-
c) Oil-filled condenser bushing
1
-
-
d) Gasket joints (may need to be tightened to avoid uneven pressure)
1
-
-
e) Check the transformer marshalling box
1
-
-
f) Relays alarm and other circuits
1
-
-
g) Transformer body clear& Paintwork
1
-
-
h) Transformer earthing test.
1
-
-
i) Transformer insulation resistance test.
1
-
-
j) All power& control terminal tightness and overheating check
1
-
-
Carriage of transformer in Para medical training college campus with loading, unloading T&P Labor complete
1
-
-
Transformer oil fresh
1
-
-
Repairing, Overhauling of 415 V, 4P A free standing floor mounted main panel for A.C. ( make -L&T) INCOMER: 2000 A, 55KA 4P,MDO ACB
1
-
-
INCOMER: 1000 A, 55KA 4P,MDO ACB
1
-
-
INCOMER: 800 A, 55KA 4P,MDO ACB
1
-
-
Repairing, Overhauling of 415 V, 4P A free standing floor mounted main panel for A.C. INCOMER: 1000 A, 50KA 4P 415V ACB (MODEL NO AH-10D-CS IEC 60947-2)
1
-
-
S/F of 630 A, 50KA 4P MCCB (Molded Case Circuit Breaker) ( make -L&T)
1
-
-
S/F of 400 A, 50KA 4P MCCB (Molded Case Circuit Breaker) ( make -L&T)
1
-
-
S/F of 250 A, 50KA 4P MCCB (Molded Case Circuit Breaker) ( make -L&T)
1
-
-
Supply And fixing of ACB 3 Phase 4-pole 2000A 415 V Cat-B (L&T Make) CN-CS 2000 S1 Amp fixed type manually operated
1
-
-
Supply And fixing of ACB 3 Phase 4-pole 1000A 415 V Cat-B (L&T Make) CN-CS 2000 S1 Amp fixed type manually operated
1
-
-
Supply And fixing of ACB 3 Phase 4-pole 800A 415 V Cat-B (L&T Make) CN-CS 2000 S1 Amp fixed type manually operated
1
-
-
Making of foundation and electric pole with cement, concrete and sand 1:3:6 including around the pole and filling properly complete
1
-
-
Charges for one time repair/ maintenance & painting of all electrical distribution panels and all feeder pillar in the Para medical campus. (indoor/outdoor)
1
-
-
S/F of Generator Battery 180 AH 12 volts .( Lead acid battery)
1
-
-
S/F of Battery 150 AH 12 volts. .( Lead acid battery)
1
-
-
Supply& Boring of copper plate 600 x 600 x 3mm, vertically for earthing with its top at least 3 mtrs. Below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no.32x6mm Cu. Stip upto glalso including 30sqcm C.I. frame charcoal/coke and salt at least 150mm thiock alround etc. as per direction of Engg-in –charge complete in all respects.
1
-
-
Supply& boring of G.I plate 600 x 600 x 3mm, vertically for earthing with its top at least 3 mtrs. Below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no.32x6mm Cu. Stip upto glalso including 30sqcm C.I. frame charcoal/coke and salt at least 150mm thiock alround etc. as per direction of Engg-in –charge complete in all respects
1
-
-
S/F of Cu. Strip size 50 x 6 mm size for earthing
1
-
-
S/F of G.I strip 32 x6 mm size earthing
1
-
-
S/F of 11 KVA Grade XLPE cable box outdoor type 185sqmm x 3 core complete
1
-
-
S/F of 11 KVA Grade XLPE cable box indoor type 185sq.mm x 3 core complete
1
-
-
S/F of Al. conuctor XLPE armoured cables 11000V grade at a depth of 700 mm below ground level over a cushion of 75 mm thick sand all around and protection with burnt bricks on sides & on top .The armourising of the cable shall be properly connected with the earth conductor by clamps etc. of following sizes:(HT) • 120 sq.mm x 3 core
1
-
-
• 185 sq.mm x 3core
1
-
-
Painting work of sub –station Transformers, shutter, DG set ,HT/LT panel, feeder pillar ,transformer,transformer shade etc
1
-
-
S&F of UPS with battery 1 KVA
1
-
-
2 KVA
1
-
-
5.5 KVA
1
-
-
10 KVA
1
-
-
12.5 KVA
1
-
-
15 KVA
1
-
-
Supply and fixing 120 watts LED Flood Lights Fittings Street Light (High power LED Flood Light With Pressure Die Cast Aluminum Housing.(OSRAM, PHILIPS,NICHIA,CREE,EVERLIGHT,TOSHIBA nichia or equivalent
1
-
-
Supply& fixing of 2x2 Panel LED celling Lights (Day cool Lights) 42 Watts. Square shape
1
-
-
Supply& fixing of 2x2 Panel LED surface Lights (Day cool Lights) 42 Watts. Square shape
1
-
-
Supply& fixing of 1x1 Panel LED celling Lights ( Day cool Lights) 36 Watts. Square shape
1
-
-
Supply& fixing of 1x1 Panel LED surface Lights ( Day cool Lights) 36 Watts. Circle shape
1
-
-
Supply 20 to 24 watts LED Tube Lights (syska, Philips, Havells, Suraya, Bajaj)
1
-
-
Supply& fixing of 70 to 100 watts LED Street for Lights. (Syska ,Havells, Matador)
1
-
-
Supply meter (single phase digital meter 5-30amp)
1
-
-
Supply meter (three phase digital meter 10-40 amp)
1
-
-
S/F of Fan regulator .Make Legrand
1
-
-
Supply Modular Switch 5/6 Amp Make Legrand
1
-
-
Supply Modular Switch 15/16 Amp Make Legrand
1
-
-
Supply Modular Socket 5/6 Amp Make Legrand
1
-
-
Supply Modular Socket 15/16 Amp Make Legrand
1
-
-
Supply 3way Modular Plate Make Legrand
1
-
-
Supply 6 way Modular plate Make Legrand
1
-
-
Supply 8 way Modular plate Make Legrand
1
-
-
Supply& fixing of Exhaust fan • 18 Inch 450 mm
1
-
-
• 12 Inch 300 mm
1
-
-
Supply& fixing 1HP Submersible pump Single phase (make Kirloskar, Crompton)
1
-
-
Supply& fixing 1.5 HP Submersible pump Single phase (make Kirloskar, Crompton)
1
-
-
Supply& fixing 2 HP Submersible pump Single phase (make Kirloskar, Crompton)
1
-
-
Supply& fixing 5 HP Submersible pump 3 phase (make Kirloskar, Crompton)
1
-
-
Supply& fixing 10 HP Submersible pump 3 phase (make Kirloskar, Crompton)
1
-
-
1HP Submersible pump Single phase binding & Repairing.
1
-
-
1.5 HP Submersible pump Single phase binding & Repairing
1
-
-
5 HP Submersible pump 3 phase binding & Repairing
1
-
-
10 HP Submersible pump 3 phase binding & Repairing
1
-
-
Repairing & servicing of 1HP Submersible Starter Single phase
1
-
-
Repairing & servicing of 1.5HP Submersible Starter Single phase
1
-
-
Repairing & servicing of 2HP Submersible Starter Single phase
1
-
-
Repairing & servicing of 5HP Submersible Starter 3phase
1
-
-
Repairing & servicing of 10HP Submersible Starter 3 phase
1
-
-
Supply and laying 75mm dia GI pipe for laying in of road cutting crossing
1
-
-
Supply and fixing of 30 Meter High mask LED Light Pure wight ,200 watts
1
-
-
Supply and fixing of 30 Meter High mask contactor 63 AMP
1
-
-
32 AMP
1
-
-
S/F OF UPS BATTERY 12VOLTS/7AH
1
-
-
S/F of LT cable joint kit • 25 sq.mm X4 core
1
-
-
• 35 sq.mm X4 core
1
-
-
• 50 sq.mm X4 core
1
-
-
• 70 sq.mm X4 core
1
-
-
• 95 sq.mm X4 core
1
-
-
• 120 sq.mm X4 core
1
-
-
• 150 sq.mm X4 core
1
-
-
• 185 sq.mm X4 core
1
-
-
• 240 sq.mm X4 core
1
-
-
• 300 sq.mm X4 core
1
-
-
• 400 sq.mm X4 core
1
-
-
Lkhfyax QSu dh dEiyhV fjokbfUMx dk dk;Z lqij buSfeyaM dkWij ok;j vkbZ0,l0vkbZ ekdZ ds }kjk vk;fyax ,oa xzhflax lfgrA 1- 48** iqjkus ia[ks
1
-
-
2- 56** iqjkus ia[ks
1
-
-
lhfyax QSu ds cq”k cnyus dk dk;Z vk;fyax ,oa xzhfalax lfgrA 1- 48** iqjkus ia[ks
1
-
-
2- 56** iqjkus ia[ks
1
-
-
lhfyax QSSu ds cq”k cnyus dk dk;Z vk;fyax ,oa xzhflax lfgr
1
-
-
Lkhfyax QSu dh vk;y ,oa xzhflax dk dk;ZA
1
-
-
Lkhfyax QSu ds dUMsUlj cnyus dk dk;ZA
1
-
-
,XtkWLV QSu dh dEiyhV fjokbfUMx dk dk;Z lqij buSfeyaM dkWij ok;j vkbZ0,l0vkbZ ekdZ ds }kjk vk;fyax ,oa xzhflax lfgrA 1&18**
1
-
-
2&20**
1
-
-
3&24**
1
-
-
,XtkWLV QSu dh ckWyfo;fjax cnyus dk dk;Zaaa A 1&18**
1
-
-
2&20**
1
-
-
3&24**
1
-
-
,XtkWLV QSu ds dUMsUlj cnyus dk dk;ZA 1&18**
1
-
-
2&20**
1
-
-
3&24**
1
-
-
,XtkWLV QSSu ds cq”k cnyus dk dk;ZA 1&18**
1
-
-
2&20**
1
-
-
3&24**
1
-
-
dkWEisDVksa rFkk vksoj gsM “ksM ds iksyks dks isUV djkus dk dk;ZA
1
-
-
dkWEisDVks rFkk QhMj fiyjksa dh lfoZflax dk dk;ZA
1
-
-
dkWEisDVksa rFkk QhMj fiyjksa ds vklikl dh ?kkl dkVkus bR;kfn dk;ZA
1
-
-