Directorate General Of Lighthouses And Lightships Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Directorate General Of Lighthouses And Lightships - DGLL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Apr 2023
Closing Date9 May 2023
Tender Amount₹ 1,11,32,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying factory made chamfered edge 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.

20

19827

991.37

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.

5

20781

4156.23

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter and frames including labours, tools & plants etc., complete and stacking within 50 metres including cost of supply of all labours, tools & plants, scaffolding and all other charges etc. complete.

188

23648

125.79

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.(In cement Mortar )

3

5417

1805.96

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

11.5

35804

3113.45

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of supply of all labours, tools & plants, scaffolding and all other charges etc. complete.

2.25

20364

9050.92

... More
Providing and laying cement concrete 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering and shuttering including cost of supply of all labours, tools & plants, scaffolding and all other charges etc. complete. (For roof top water tank plateform)

4

41654

10413.69

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Columns,beams, slab, piers, abutments, pillars, posts and struts etc (For roof top water tank plateform)

84.24

72038

855.16

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (For roof top water tank plateform)

303.2

28901

95.32

... More
Providing and laying in position cement concrete :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) of specified grade excluding the cost of centering and shuttering - All work up to plinth level

15.9

115528

7265.95

... More
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95x38.10x0.90 millimetre at weight 0.637 kg/mtr.with window frame bottom track section 92x31.75x1.30 mm at weight 1.070kg./mtr.Top and side track section 92x31.75x1.30mm at weight 0.933kg/mtr. The shutter should be of bearing bottom 40x18x1.25mm at weight 0.417kg/mtr. inter locking section 40x18x1.10mm at weight 0.469kg/mtr.and handle and top section 40x18x1.25 mm at weight 0.417kg/mtr. as per detailed drawing and as directed by Engineer incharge with all necessary Aluminium section fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted verticle section of shutter including 5 mm thick high performance single glaze unit (SUG)-glass aluminium mosquito net shutter with stainless steel jali with all required screws and nuts etc,complete. With colour anodising with box. including cost of all materials, labour, tools, scaffolding etc; complete

112.88

540113

4784.85

... More
Providing and fixing of colured rolling blinds with pelmet in Aluminium window of approved brand and colour as directed including frame and necessary require item etc complete with cost of supply of all labours, materials, tools and plants and all other charges etc complete

112.88

144030

1275.96

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine/coarse sand)

973

478287

491.56

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections including cost of supply of all labours, materials, tools and plants and all other charges etc complete

100

6880

68.8

... More
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement: 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine/coarse sand) mixed with 10% finely grounded hydrated lime by volume of cement.

207

165606

800.03

... More
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work

25

12484

499.38

... More
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto and above 12 mm diameter

50

710

14.2

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

50

20758

415.17

... More
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. 25 mm average thickness in 2 layers.

50

27140

542.81

... More
Providing and fixing of MS cupboard of depth upto 550mm including removing and dismantling of existing plywood cupboard and its RCC shelf etc including cost of supply of all materials, labors tools and plants etc (as per existing fixed MS cupboard)

36

287091

7974.75

... More
Finishing walls with two coats of Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2300

408043

177.41

... More
Wall painting two coats with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.

1032

133375

129.24

... More
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

1032

22879

22.17

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1032

135904

131.69

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer

1032

70722

68.53

... More
Polishing on wood work with ready made wax polish of approved brand and manufacture- for old work

40

3528

88.2

... More
Providing wood work in frames (Second class teak wood) of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length-

0.15

20985

139905.77

... More
Providing and fixing 35mm thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hardwood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including necessary hardwares i.e including necessary hardwares ISI marked M.S. pressed butt hinges bright finished 250mm GI tower tower bolt, 150mm drop bo;t, all of approved quality as per drawing nd specification including cost of supply supply of all labour, materials, tools etc complete.

16.5

54143

3281.45

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

10

7696

769.62

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm

10

1251

125.1

... More
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete

10

1165

116.54

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment withnecessary accessories and screws etc. complete.

6

5463

910.5

... More
Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125 mm

18

4335

240.84

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm

270

26813

99.31

... More
Providing and fixing Ist quality ceramic glazed wall tiles (300mmx600mm) conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make and size, in all colours, shades as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

92

104030

1130.77

... More
Providing and laying vetrified floor tiles of size 600mmx600mm size with water absorption less then 0.08% and conforming to IS 15622 of approved make ( Johnson /Kajaria /Nelco), in all colours and shades laid on 20mm. thick cement mortar 1:4(1cement,4coarse sand), including grouting the joints with white cement and matching pigments etc. In true line and level and joints filled with white cement and matching pigments, including cost of supply of all labours, tools and plants, materials and finishing etc. complete as directed by the Engineer in charge.

180

280679

1559.33

... More
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Medium shade pigment using 50% white cement, 50% ordinary cement

53

73943

1395.16

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of different dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
20 mm nominal dia Pipes

15

4389

292.62

... More
25 mm nominal dia Pipes

15

5911

394.11

... More
1. Applying a coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge after cleaning of slab surface and removing of all loose particle 2.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry including cost of supply of all materials labors, tools and plants, curing etc complete for making of proper slope in roof surface to completely drain out of water. (For roof treatment work)

150

126958

846.39

... More
Providing and applying of Dr fixit 603 NEWCOAT (Heavy duty Reinforced Acrylic water proof coating) water proofing treatment with the following steps-1. cleaning of slab surface and removing of all loose particle. 2-filling of all cracks and joints with cement and Dr fixit URP. 3-Applying of one coat primershield primer. 4-Applying 1st coat of Dr. fixit new coat with fibre mess. 5-Applying of 2nd coat Dr fixit new coat. 6-Applying of Dr fixit 3rd and final coat and as per the specification of Dr fixit, including cost of supply of all materials labors, tools and plants etc complete (As per manufacture specification) (For roof treatment work)

150

151998

1013.32

... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.

332.75

16451

49.44

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)

202.5

246744

1218.49

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main"T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.

317.63

625149

1968.17

... More
Supply of low height modular four seater Workstation with partitions as per following: Partitions:- 75mm thickness, height 1300mm, provision for cable tray below & above workstation partition, minimum cable tray 50mm, Frame :- Steel frame, powder coated oven baked finish, average weight of 900mm x 1200mm frame shall be 14kg minimum shall have tile fixing arrangement partition finish combination of 10mm thick MDF with 1mm laminated on both sides, 12mm thick fabric tiles, 12mm thick pinup tiles made up of 6mm polypropylene fluted sheets as per approved design and shade, curved trim Table top:- 1500mm x 1500mm pre laminated partical board. Accessories :- 3 drawer units with locking arrangement, keyboard pullout tray, and powder coated CPU trolley, concealed wire management all as approved etc including cost of supply of all labour, materials, tools, transportation etc complete.

2

456708

228354.31

... More
Supply of low height modular two seater Workstation with partitions as per following: Partitions:- 75mm thickness, height 1300mm, provision for cable tray below & above workstation partition, minimum cable tray 50mm, Frame :- Steel frame, powder coated oven baked finish, average weight of 900mm x 1200mm frame shall be 14kg minimum shall have tile fixing arrangement partition finish combination of 10mm thick MDF with 1mm laminated on both sides, 12mm thick fabric tiles, 12mm thick pinup tiles made up of 6mm polypropylene fluted sheets as per approved design and shade, curved trim Table top:- 1500mm x 1500mm pre laminated partical board. Accessories :- 3 drawer units with locking arrangement, keyboard pullout tray, and powder coated CPU trolley, concealed wire management all as approved etc supply of all labour, materials, tools, transportation etc complete.

2

238391

119195.93

... More
Supply of low height modular single seater Workstation with partitions as per following: Partitions:- 75mm thickness, height 1300mm, provision for cable tray below & above workstation partition, minimum cable tray 50mm, Frame :- Steel frame, powder coated oven baked finish, average weight of 900mm x 1200mm frame shall be 14kg minimum shall have tile fixing arrangement partition finish combination of 10mm thick MDF with 1mm laminated on both sides, 12mm thick fabric tiles, 12mm thick pinup tiles made up of 6mm polypropylene fluted sheets as per approved design and shade, curved trim Table top:- 1500mm x 1500mm pre laminated partical board. Accessories:- 3 drawer units with locking arrangement, keyboard pullout tray, and powder coated CPU trolley, concealed wire management all as approved etc including cost of supply of all labour, materials, tools, transportation etc complete.

2

125469

62734.7

... More
Providing and fixing in position 3.0m height partition both side prelaminated and frame work made from selected seasoned hardwood timber, 100mm thick cladded with 6mm ply on both sides and laminate with 1mm thick of approved shade sunmica and glazing with 4mm floated glass as per specification, drawings, design, supply of all labour, materials, tools etc complete.

31.5

184216

5848.15

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building, wherever required for inspection of work at required locations with essential safety features for the workmen, etc., complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.

900

272736

303.04

... More
Providing and fixing 12 mm thick frameless frosted toughened glass door shutter with department logo (as per existing desigh and pattern) of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, Door handle, lock and stopper etc all complete (reputed make) as per direction of Engineer-in-charge.

10.08

114211

11330.52

... More
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.

224.38

99631

444.03

... More
Repair and maintenance of existing sliding gate with replacement of existing motor by 2HP Crompton Greaves motor with gear box, motor gear racks with gear, operating motor panel with sunk counter, control switch with 3core wire, and base wheels etc including cost of supply of all materials, labour and all other charges with scarp charges of dismentled items etc complete

1

52101

52101.7

... More
Removing and refixing of existing roof top water tank after the completion of water tank plateform with making suitable inlet and out let connections including the cost of supply of all materials, labour, tools and plants etc complete.

3

7974

2658.25

... More
Dismentling of existing concrete and excavation of hole pit for genset 100mm dia MS pipe including providing and laying of C C 1:2:4(1 cement :2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources) as directed including cost of supply of all labour, materials, tools etc complete.

6

7655

1275.96

... More
Providing and fixing of MS hollow tube section, angulars, flats and channel framed structure and 100mm dia GI pipe of approval size by welding etc to genset shed as per drawings and as directed including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, welding and bolted with special shaped warsher etc. complete with applying epoxy primer coat of approved steel primer etc including cost of supply of all labors, materials, tools and plants and fixing all other charges etc complete. MS Hollow tube sections, angulars flats etc framed structure

750.33

125380

167.1

... More
Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 withcharacteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self rilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately).0.91 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.

126

222071

1762.47

... More
Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

416

24548

59.01

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work

620

86657

139.77

... More
Shiffting of all demolised debris from Deep Bhavan premises to municipal limits for dumping of dabris and cleaning this site including loading of truks and unloading at munsipal areas supply of all labours transportation charges etc complete.

15

15949

1063.3

... More
Scrap Value of removed Paver Block including cost of transportation and all other charges etc complete.

20

-21

1.06

... More
Scrap Value of Dismentled of windows shutters and grill and completely removing from the office premises including cost of transportation and all other charges etc complete.

188

-19990

106.33

... More
By back/scrap value of Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.

332.75

-3537

10.63

... More
Scrap Value of Dismentled existing four seater with completely removing from the office premises including cost of dismentling, transportation and all other charges etc complete.

2

-5316

2658.25

... More
Scrap Value of Dismentled existing two seater with completely removing from the office premises including cost of dismantling, transportation and all other charges etc complete.

2

-3189

1594.95

... More
Scrap Value of Dismentled existing single seater with completely removing from the office premises including cost of dismentling, transportation and all other charges etc complete.

2

-2126

1063.3

... More
Completely dismentling of existing Genset shed including recovery of salvage value/scrap value of recovered materials at the time od dismantling of shed etc. including cost of transportation from the site as per direction of engineer in charge.

1

-5316

5316.5

... More
PART-B ELECTRICAL WORKS

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C

190

278730

1467

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A

100

64900

649

... More
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.

10

8940

894

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

-

-

-

... More
2 x 1.5 sq. mm +1 x1.5 sq. mm earth wire

450

104850

233

... More
2 x 2.5sq.mm+1 x2.5sq.mm earth wire

300

82500

275

... More
2 x 4 sq.mm+1 x4 sq.mm earth wire

350

116900

334

... More
2 x 6 sq. mm +1 x 6 sq. mm earth wire

150

65850

439

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

300

38400

128

100

18400

184

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required (for telephone connection) 1 run of cable

350

19950

57

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

80

8240

103

... More
15/16 A switch

25

3900

156

... More
3 pin 5/6 A socket outlet

50

6100

122

... More
6 pin 15/16 A socket outlet

25

4925

197

... More
Telephone socket outlet

50

7400

148

... More
Bell push

13

1820

140

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required

-

-

-

... More
1 or 2 Module (75mm X 75mm)

38

11324

298

... More
3 Module (100mmX75mm)

25

8175

327

... More
4 Module (125mmX75mm)

8

2744

343

... More
6 module (200mmX75mm)

25

10050

402

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

38

5054

133

... More
3 Module

25

3775

151

... More
4 Module

10

1580

158

... More
6 module

28

5096

182

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required

54

36504

676

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

40

23440

586

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

13

1287

99

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

7

3339

477

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

15

600

40

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required

6

2214

369

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C "curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

180

46080

256

... More
Double pole

2

1312

656

... More
Triple pole and neutral

6

7368

1228

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63A

5

14360

2872

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earSupplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door

5

20455

4091

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Server room) 12 way , Double door

1

2315

2315

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB

5

6700

1340

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

3

4776

1592

... More
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required

17

12359

727

... More
Supplying and installation of LED false ceiling light round type 10-watt cool white light mark ISI Support to hang the fixture to be provided in the roof with suitable length of chain links or GI wires of suitable size, as per recommendation of the light manufacturer.

121

107085

885

... More
Supplying and installation of LED false ceiling light square type 2x2 size 36–40-watt cool white light mark ISI Support to hang the fixture to be provided in the roof with suitable length of chain links or GI wires of suitable size, as per recommendation of the light manufacturer.

101

297950

2950

... More
Dismantling old split type 1.5-ton capacity air conditioner, including all connection as required complete.

17

10030

590

... More
Installation of indoor-outdoor unit of air conditioner it to the desired location, closing of open space with plywood, including all connection as required complete.

8

11328

1416

... More
Re- Installation of indoor unit of air conditioner it to the desired location, closing of open space with plywood, including all connection as required complete.

17

14042

826

... More
Supply, and Installation of refrigerant pipes of copper, required for the re fixing installation

35

30975

885

... More
Supply, and Installation of following drain piping for indoor units complete with connection etc.

20

2360

118

... More
Supply, and Installation of 3 core wire suitable for air conditioner electrical connection

40

7080

177

... More
Supply, and Installation of 20 mm dia pipe size CPVC pipes having thermal stability for hot & cold-water supply, plain & brass threaded fitting including jointing of pipes

50

16284

325.68

... More
Supply and fixing wall mounted fan 400mm size mark ISI

20

59000

2950

... More
Providing and fixing male female plug 5 amp.

50

1180

23.6

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
10 Pair

100

8260

82.6

... More
20 Pair

80

12272

153.4

... More
Supplying and installation of 50 Pair MDF BOX with Krone strip

5

8850

1770

... More
MAINTENANCE FREE CHEMICAL GEL EARTHING SYSTEM Supply of advance chemical gel earthing system for the proper dissipation of fault / leakage current to the ground and ensure the continuous electrical connectivity and proper functioning to the electrical system. The earth rod shall be of UL listed & CPRI tested 3 mtr. long 17.2 mm dia 250 microns copper bonded steel rod along with 50Kgs of Resistance Lowering Grounding Minerals. The chemical compound should be tested and certified by any international accredited and BIS (Bureau of Indian Standards) accredited laboratory. The testing laboratory should be ISO 9001 & IS) 14001 certified. The UL listed copper bonded rod also should be tested & certified from CPRI for a short circuit current of 31.5 KA or more. The UL listing shall be punched / engraved on the rod for the physical verification at site. The engravings shall contain the following details - UL Control number, Dimension details of the rod, Product model number & UL certificate reference number as per detailed technical specification attached. To ensure the electrical conductivity, 50 Kgs (per pit) or more resistance grounding minerals per earth pit l earth rod shall be used along with the copper bonded rod. The chemical compound shall be tested for the contents from BIS (Bureau of Indian Standards, Govt of India) & NABL accredited laboratory in India. The testing laboratory shall be an ISO 9001 & ISO 14001 certified. As per IEEE 80-2013 (Clause 14,5 d), the grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr. The grounding minerals should be ROHS certified to ensure it does not pollute the ground water.

5

27582

5516.5

... More
SITC of copper lightning arrester of 16mm dia/ 500mm long air terminal along with fixing base plate fixing at all corners of building along with Mumty room.

12

11682

973.5

... More
SITC of copper lightning arrester of 16mm dia/ 1000mm long air terminal along with fixing base plate fixing near antenna.

3

5763

1921.04

... More
SITC of Vertical Copper Lighting Arrester of 16MM dia, 3000 mm long with Gun Metal base plate fixing at near water tank, Chimney, & solar module area.

10

67850

6785

... More
SITC of copper strip -25x5 mm for horizontal lightning protection - run in roof.

260

371228

1427.8

... More
SITC of copper strip -25x5 mm for vertical lightning protection - run in wall as down conductor.

80

114224

1427.8

... More
INTERCONNECTION CONDUCTOR: 25x5 cu strip to inter connect of all earthing.

12

17133

1427.8

... More
Supply of Digital AC clamp meter for measuring DC and AC Voltage, AC current, resistance, continuity test, continuity buzzer, Digital LCD panel ISI mark

1

3528

3528.2

... More
Supply of Socket Spanner set included 19 sockets ISI mark

1

5286

5286.4

... More
Labour Charges for removing of old tube light, ceiling fans, wall fan, old electrical supply point, switch/socket, electrical wire, G.I strip MCBs, motor starters etc complete and store at desired place.

1

11800

11800

... More
PART-C ELECTRICAL POWER DISTRIBUTION PANEL AND CABLING WORK

-

-

-

... More
Supply, installation, testing & commissioning of Industrial Main panel Lighting cum power distribution board with Volt Ampere and frequency meter, R Y B indication, CT & PT suitable way comprising of 1 No.630A, 4P, MCCB, C series Main panel following switch etc. on suitable angle iron frame CRCA Sheet panel body 16 gauge panel door 14 gauge & power coted paint, all power wire RYBN colour including inter connection wiring 1.5 sq. mm FRLS size CT&PT circuit wire 2.5 sq. mm FRLS with socketing earthing attachment etc. & outgoing circuits with suitable copper wires/busbars for each phase and neutral with earth link and all other components In comer: 630 A (100 MA) 4 Pole MCCB 7 Nos. Outgoing :200 A 3 Pole MCCB including Surge protection facility, and provision of capacitors bank 3 Phase, 440 Volt Power Capacitor Bank suitable rating for improving power factor for section load 123 KVA

1

1244802

1244802.06

... More
CABLE AND TERMINATION Supply, installation & dressing of 1.1 KV grade PVC insulated armoured cable with copper conductor including back filling of trenches if necessary.

-

-

-

... More
4 core 70 sq.mm from transformer to Meter box and meter box to Main panel

60

401365

6689.42

... More
4 core 35 sq.mm from Main panel to PAO Side distribution box

40

171619

4290.48

... More
4 core 16 sq.mm Main panel to IT cell side distribution box

5

9959

1991.84

... More
4 core 25 sq.mm Main panel to Admin-II Side distribution box

30

93102

3103.4

... More
4 core 16 sq.mm Main panel to C&G ground floor distribution box

55

109551

1991.84

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Up to 35 sq. mm (clamped with 1mm thick saddle)

130

7150

55

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

60

7800

130

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 16 sq. mm (22mm)

4

1236

309

... More
4 X 25 sq. mm (28mm)

3

945

315

... More
4 X 35 sq. mm (32mm)

3

1110

370

... More
4 X 35 sq. mm (32mm)

5

2090

418

... More
Busbar Chamber Box Enclosures are made from thick CRCA Sheet, protected with seven tank phosphating process and powder coated to prevent from corrosion. Copper Strips are used for better conductivity & are fitted in steps. Fire Retardant Bakelite sheets are fitted at the interior bottom of chamber and also have high insulation properties. Earthing terminals are provided on both sides

-

-

-

... More
200 Amp, 415 volt

1

6554

6554.9

... More
100 Amp, 415 volt

4

23600

5900

... More
Supply of TPMCCB Metal sheet box for fixing of MCCB ISI make

5

9381

1876.2

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
100 A, 16 KA, TPMCCB

4

15108

3777

... More
200 A, 25 KA, TPMCCB

1

11016

11016

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

26

22568

868

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

-

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

45

61425

1365

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7-metre-long etc. with charcoal/ coke and salt as required.

1

7472

7472

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm

25

3600

144

... More
Brazing of all the connectors and connecting assemblies with G.I. Plates

1

3540

3540

... More
Labour charges for dismantling of existing cable connection and old paneLabour charges for dismantling of existing cable connection and old panel, necessary connection of new cable, miscellaneous item like cable tie, PVC pipe, different size copper lugs, insulation tap, flexible pipe, steel nut-bolt, steel spring and bolts hacksaw blade. Etc.

1

21240

21240

... More
Buyback value of old existing copper wire, Modular switches - sockets, G. I box, PVC box, Modular plate, Modular boxes, MCBs, G.I strip, PVC pipe (without MCB distribution box) & other ancillary and components.

1

-15000

15000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.