If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Director General Medical Health - DGHS Tender

Works
Security and Emergency Services
Eprocure
Opening Date3 Jan 2024
Closing Date11 Jan 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Summary

(line 03) Maintenance/reparing And Annual Operating Charges Of Pre Installed Fire Fighting System At District Male/female/ Other Hospitals,community Health Centers Of Moradabad , Rampur, Amroha, Sambhal And Bijnor (except Dch Bijnor).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, installation, testin & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

1

-

-

... More
Supplying, installation, testin & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required

1

-

-

... More
Supplying, installation, testin & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc as required.

1

-

-

... More
Supplying, installation, testin & commissioning fire alarm sounder with facility to make announcement, mounted in M.S box (16 SWG) with hanged cover plate & suitable for operation with amplifire i/c line matching transformer etc. complete as required.

1

-

-

... More
Supplying, installation, testin & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hanged cover plate & suitable for operation with amplifire i/c line matching transformer etc. complete as required.

1

-

-

... More
Supplying, installation, testin & commissioning talk back slave station in surface/recess suitable for operation on simples mode complete with P.T.T. knob & speaker/microphone enclosed in M.S. (16 SWG) ABS box with break glass in front etc. complete as required.

1

-

-

... More
Supplying, installation, testin & commissioning sector panel suitable for following zones complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all conectins interconnections as required.

-

-

-

... More
4 Zone

1

-

-

... More
6 Zone

1

-

-

... More
10 Zone

1

-

-

... More
Supplying, installation, testin & commissioning of main control and indication panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation locking arrangement audio and visual indication for fire alarm and public address system monitoring system including connection, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifire racks suitable for operation on 230V AC/24V DC supply conforming to IEC -268-3 complete with all accessories as required-2 Nos (one to act as stand by) Talk back msater station with LED PTT (Press to talk) push button for operation on 230 V AC/24 V DC supply conforming to IEC -268 for simples mode of operation/communication suitable for 20 Nos. talk back unit -1 set Annoucement control desk sitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. Complete as required -1 Set. Amplifire change over switch for inter changing amplifier-1 No Monior panel for loudspeaker complete with outpur selector, ON/OFF Switch, fuse indication lamps DC and AC Voltmeters & ammeters, terminal block etc, complete as required-1 set. No. Gooseneck microphone with stand and ON/OFF switch-1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeter, terminal blocks etc. complete as required-1 Set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH each sealed maintenance free batteries-1 set.

1

-

-

... More
Supplying installation, testion & commissioning of main control and indication pannel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections. interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifire racks suitable for operation on 230V AC/24 V DC supply conforming to IEC-268-3 complete with all accessories as required -2 Nos (one to act as standby) Talk back msater station with LED PTT (Press to talk) push button for operation on 230 V AC/24 V DC supply conforming to IEC -268 for simples mode of operation/communication suitable for 20 Nos. talk back unit -1 set Annoucement control desk sitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. Complete as required -1 Set. Amplifire change over switch for inter changing amplifier-1 No Monior panel for loudspeaker complete with outpur selector ON/OFF Switch, fuse visual indications etc. Complete as required-1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeter, terminal blocks etc. complete as required-1 Set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH each sealed maintenance free batteries-1 set.

1

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube. 30 cms long high pressure discharge hose. Discharge nozzle, suspension bracket, confiming to IS:934 finished externaly with red enamel paint and fixed to wall with brackets with rawl plug dash fasteners complete with internal charge. Capacity 4.5 Kg

1

-

-

... More
Refiling of Carbon-di-oxide fire extinguisher, Capacity 4.5

1

-

-

... More
Providing and fixing of DCP type fire extinguisher ISI marked & TAC Approved complete in all respect.Capacity 5.0 Kg

1

-

-

... More
Refiling of DCP type fire extinguisher, Capacity 5.0

1

-

-

... More
Providing and fixing of ABC type (stored pressure) fire extinguisher ISI marked & TAC approved complete in all respect.

-

-

-

... More
Capacity 4.0 Kg

1

-

-

... More
Capacity 2.0 Kg

1

-

-

... More
Refiling of ABC type (stored pressure) fire extinguisher, Capacity 4.0

1

-

-

... More
Refiling of ABC type (stored pressure) fire extinguisher, Capacity 2.0

1

-

-

... More
INTELLIGENT FIRE ALARM SYSTEM

-

-

-

... More
Supplying installation, testion & commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km. network communication card, minimum 320 craracter graphics/LCD display with touch screen or other keypad and minimum 400 events history log in the non volatile memory (EPROM), power supply unit (230 +_ 5% V, 50hz) 48 hrs back up with 24 volt sealed maintenance free batteries with automatic charger The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evaccuatin system (wchic is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shallbe compatible for IBMS system with open protocol BAC net/Modbus over IP complete as per specifications.

-

-

-

... More
Ten Loop Panel.

1

-

-

... More
Two Loop Panel.

1

-

-

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required

1

-

-

... More
Supplying installation, testion & commissioning of repeater panel with 320 character/Touch screen LCD display with inbuilt rset. Acknowledge and silence swithches complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of intelligent analog addressable phototermal detector complete with mounting base complete as requierd

1

-

-

... More
Supplying installation, testion & commissioning of response indicator on surface/recessed MS Box having two LED metalic cover complete with all connections etc as required.

1

-

-

... More
Supplying installation, testion & commissioning of intelligent addressable programmable sounder complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of fault isolator complete with base as required.

1

-

-

... More
Supplying installation, testion & commissioning of intelligent aspiration detector for area coverage of minimum 500 sq ft complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of intelligent addressable termal detector with rate of rise cum fixed temprature thermistor complete with base as required.

1

-

-

... More
Supplying installation, testion & commissioning of addressable fire control module complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of addressable phone control module complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc momplete as required.

1

-

-

... More
Supplying installation, testion & commissioning of intelligent addressable duct detector including suitable photo detector complete with base as required.

1

-

-

... More
Supplying installation, testion & commissioning of addressable manual call point complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of addressable horn cum strobe complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of addressable strobe complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of fire fighter telephone handset complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of intelligent interface unit BAC net/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of fire fighter telephone jack complete as required.

1

-

-

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
Supplying installation, testion & commissioning of 6 ZONE, Voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of 1.5/3/6W celling speaker complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of ceiling /wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of digital audio amplifier 50 Watt. 25V rms operation at 240 volt AC supply complete ar required.

1

-

-

... More
Suplying installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operation at 240 Volt AC Supply complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of exit point directional sound speaker with viice and integral audio amplifier with selectable sound pulse patterns complete as required.

1

-

-

... More
Supplying installation, testion & commissioning of Voice comand keypad 6 zone, with microphone assembly complete as required.

1

-

-

... More
ASPIRATION DETECTOR ACCESSORIES

-

-

-

... More
Supplying installation, testion & commissioning of 25 mm Quter dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropraiate interval and all accessories as required, (rate for area protected in sqm)

1

-

-

... More
CABLING & WIRING

-

-

-

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extrudid layer of Cross Linkable Ethlene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.

1

-

-

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

1

-

-

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface/recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.

-

-

-

... More
Speaker cable Single pair, 2-core, 1.5 sqmm

1

-

-

... More
Speaker cable Two pair, 2-core, 1.5 sqmm

1

-

-

... More
Speaker cable Three pair, 2-core, 1.5 sqmm

1

-

-

... More
Speaker cable Four pair, 2-core, 1.5 sqmm

1

-

-

... More
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.

1

-

-

... More
PUMP

-

-

-

... More
(A) Supplying installation testing and commissioning of Electric driven Main fire Pump suitable for automatic operation and consisting of following, complete in all respects as required. (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class- 'F' insulation, conforming IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. Note:* The head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
2850 Ipm at 88 m Head

1

-

-

... More
2850 Ipm at 70 m Head

1

-

-

... More
2850 Ipm at 56 m Head

1

-

-

... More
2280 Ipm at 88 m Head

1

-

-

... More
2280 Ipm at 70 m Head

1

-

-

... More
2280 Ipm at 56 m Head

1

-

-

... More
1620 Ipm at 88 m Head

1

-

-

... More
1620 Ipm at 70 m Head

1

-

-

... More
1620 Ipm at 56 m Head

1

-

-

... More
(A) Repairing work of diesel engine driven main fire pump including rewinding of stator coil and required machining work Complete in all respects as required. (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class- 'F' insulation, conforming IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. Note:* The head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
2850 Ipm at 88 m Head

1

-

-

... More
2850 Ipm at 70 m Head

1

-

-

... More
2850 Ipm at 56 m Head

1

-

-

... More
2280 Ipm at 88 m Head

1

-

-

... More
2280 Ipm at 70 m Head

1

-

-

... More
2280 Ipm at 56 m Head

1

-

-

... More
1620 Ipm at 88 m Head

1

-

-

... More
1620 Ipm at 70 m Head

1

-

-

... More
1620 Ipm at 56 m Head

1

-

-

... More
(A) Supplying installation testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following. Complete in all respects as required. (Diesel Driven Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indication, painted with post office red colour etc, as required. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. Note:* The head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
2850 Ipm at 88 m Head

1

-

-

... More
2850 Ipm at 70 m Head

1

-

-

... More
2850 Ipm at 56 m Head

1

-

-

... More
2280 Ipm at 88 m Head

1

-

-

... More
2280 Ipm at 70 m Head

1

-

-

... More
2280 Ipm at 56 m Head

1

-

-

... More
1620 Ipm at 88 m Head

1

-

-

... More
1620 Ipm at 70 m Head

1

-

-

... More
1620 Ipm at 56 m Head

1

-

-

... More
(A) Repairing work of diesel engine driven main fire pump including rewinding of stator coil and required machining work Complete in all respects as required. (Diesel Driven Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indication, painted with post office red colour etc, as required. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. Note:* The head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
2850 Ipm at 88 m Head

1

-

-

... More
2850 Ipm at 70 m Head

1

-

-

... More
2850 Ipm at 56 m Head

1

-

-

... More
2280 Ipm at 88 m Head

1

-

-

... More
2280 Ipm at 70 m Head

1

-

-

... More
2280 Ipm at 56 m Head

1

-

-

... More
1620 Ipm at 88 m Head

1

-

-

... More
1620 Ipm at 70 m Head

1

-

-

... More
1620 Ipm at 56 m Head

1

-

-

... More
(A) Supplying installation testing and commissioning of diesel engine driven main pressuristaion pump suitable for automatic operation and consisting of following. Complete in all respects as required. (Jockey Pump)(B) Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP squirell cage induction motor TEFC type suitable of operation on 415 volts, 3 phase 50Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
180 Ipm at 88 m Head

1

-

-

... More
180 Ipm at 70 m Head

1

-

-

... More
180 Ipm at 56 m Head

1

-

-

... More
300 Ipm at 88 m Head

1

-

-

... More
300 Ipm at 70 m Head

1

-

-

... More
300 Ipm at 56 m Head

1

-

-

... More
(A) Repairing work of diesel engine driven main fire pump including rewinding of stator coil and required machining work Complete in all respects as required. (Jockey Pump)(B) Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP squirell cage induction motor TEFC type suitable of operation on 415 volts, 3 phase 50Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
180 Ipm at 88 m Head

1

-

-

... More
180 Ipm at 70 m Head

1

-

-

... More
180 Ipm at 56 m Head

1

-

-

... More
300 Ipm at 88 m Head

1

-

-

... More
300 Ipm at 70 m Head

1

-

-

... More
300 Ipm at 56 m Head

1

-

-

... More
(A) Supplying installation testing and commissioning electric driven terrace pump suitable for automatic operation and consisting of following. Complete in all respects as required. (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP squirell cage induction motor TEFC type suitable of operation on 415 volts, 3 phase 50Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
900 Ipm at 35 m Head

1

-

-

... More
450 Ipm at 35 m Head

1

-

-

... More
(A) Repairing work of diesel engine driven main fire pump including rewinding of stator coil and required machining work Complete in all respects as required. (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ( C ) Suitable HP squirell cage induction motor TEFC type suitable of operation on 415 volts, 3 phase 50Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc, as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
900 Ipm at 35 m Head

1

-

-

... More
450 Ipm at 35 m Head

1

-

-

... More
CONTROL PANELS

-

-

-

... More
Fabrication, supply Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2 mm thick CRCA sheet, Compartmentalised with hinged lockable doors, dust and vermin proof, powedr coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals. numbering etc. complete in all respect, suitable for main fire pump. Pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415 V, 3 phase. 50Hz AC Supply with enclosure protection class IP 42 as required.

-

-

-

... More
INCOMING 250 A, 50KA 4 pole MCCB, Ics=100% icu rating Difital Voltmeter 0-500V with Selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 125 A, 50kA TPN MCCB, Iccs=100% Icu, with fully automatic Star/Delta Starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. JUCKEY PUMP 63 A, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. DIESEL ENGINE CONTROL Control for diesel engine comprising Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 400 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-400A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 500A OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for Iocal/remote, auto/manual /OFF operation JUCKEY PUMP 100 A, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. DIESEL ENGINE CONTROL Control for diesel engine comprising Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 630 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-630A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 800Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 250 A, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation JUCKEY PUMP 125 A, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 400 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-400A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 500Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 125 Amp, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation -2 Sets JUCKEY PUMP 60 Amp, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation- 2 Sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 630 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-630A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 800Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 200 Amp, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation -2 Sets JUCKEY PUMP 100 Amp, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation- 2 Sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 800 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-800A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 1000Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 250 Amp, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation -2 Sets JUCKEY PUMP 125 Amp, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation- 2 Sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine.

-

-

-

... More
REPAIRING OF CONTROL PANELS

-

-

-

... More
Repairing of Electrical control panel ratings three phase 415 Volts 50 Hz including replacement of all type insulators, busbar, all type insulation, analog and digital Ampere and volte meters & multy function meters demaged panel covers, luvers, filters and all type locks to proper reparing work.

-

-

-

... More
INCOMING 250 A, 50KA 4 pole MCCB, Ics=100% icu rating Difital Voltmeter 0-500V with Selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 125 A, 50kA TPN MCCB, Iccs=100% Icu, with fully automatic Star/Delta Starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. JUCKEY PUMP 63 A, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. DIESEL ENGINE CONTROL Control for diesel engine comprising Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 400 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-400A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 500A OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for Iocal/remote, auto/manual /OFF operation JUCKEY PUMP 100 A, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. DIESEL ENGINE CONTROL Control for diesel engine comprising Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 630 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-630A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 800Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 250 A, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation JUCKEY PUMP 125 A, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 400 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-400A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 500Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 125 Amp, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation -2 Sets JUCKEY PUMP 60 Amp, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation- 2 Sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 630 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-630A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 800Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 200 Amp, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation -2 Sets JUCKEY PUMP 100 Amp, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation- 2 Sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine. SYSTEM CONTROLLER Dasigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump. Diesel pump Pressurization pump. Terrance pump in sequence as per specification conisting of relays timers Sensors annuciation window for fault indication cimplete as per specification.

1

-

-

... More
INCOMING 800 A, 50kA 4 ple MCCB, ics=100% Icu rating digital voltmeter 0.500V with selector switch Ammeter (0-800A) with selector switch & CTs etc LED Type RYB phase idicating lamps. ON, OFF, trip Indication lamps set of Copper Bus Bar 1000Amps OUTGOING (Note: All outgiing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicationg lamps) MAIN FIRE PUMP 250 Amp, 50KA 4 pole MCCB, Ics=100% icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF Operation -2 Sets JUCKEY PUMP 125 Amp, 50kA TPN MCCB, Iccs=100% Icu, with suitable HP fully automatic Star/Delta Starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for Local/remote, auto/manual/off operation- 2 Sets. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor seitch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode inducating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on idication Battery charger suitble for 12V/24V DC with boost and triclkle selector switch, 0-30 V DC volt meter, and 0-20 ADC Ammeter all standard relays and accessories fir automatic operation of diesel engine.

-

-

-

... More
PIPES & ACCESSORIES

1

-

-

... More
Providing laying testing & commissionning of 'C' class heavy duty MS pipe conforming to IS 1239/3589 I/c fittings like elbows, tees flanges, lapers, nuts bolts gaskets etc. in ground including welding excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.

1

-

-

... More
200 mm dia (wall thickness = 6.3mm)

1

-

-

... More
150 mm Dia

1

-

-

... More
Providing laying testing & commissionning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding fittings like elbows, tees flanges, tapers, nuts bolts gaskets etc and fixing the pipe on the wall/celling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.

-

-

-

... More
25 mm dia

1

-

-

... More
32 mm dia

1

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm Dia

1

-

-

... More
200 mm dia (wall thickness = 6.3mm)

1

-

-

... More
250 mm dia ( wall thickness = 6.3 mm)

1

-

-

... More
300 mm dia ( wall thickness = 7.1 mm)

1

-

-

... More
Providing laying testing & commissionning of 'B' class medium duty GI pipe conforming to IS 1239 including welding, fittings like elbows, tees flanges, tapers, nuts bolts gaskets etc and fixing the pipe on the wall/celling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.

-

-

-

... More
25 mm dia

1

-

-

... More
32 mm dia

1

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm Dia

1

-

-

... More
Supplying and fixing headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked confroming to IS 5290 (type-A) with blank Gunmetal/Stainless steel cap and chain as required.

-

-

-

... More
Single headed Gunmetal

1

-

-

... More
Single headed Stainless steel

1

-

-

... More
Supplying and fixing headed external yard hydrant valve with 1 No 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel ISI marked, conforming to IS 5290 (type-A) with blank Gunmetal/Stainless steel cap and chain as required.

-

-

-

... More
Single headed Gunmetal

1

-

-

... More
Single headed Stainless steel

1

-

-

... More
supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.

-

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
200 mm dia

1

-

-

... More
250 mm Dia

1

-

-

... More
300 mm Dia

1

-

-

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gunmetal seat ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required.

-

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
200 mm dia

1

-

-

... More
250 mm Dia

1

-

-

... More
300 mm Dia

1

-

-

... More
Supplying, fixing, orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete with

1

-

-

... More
Providing installation, testing and commissioning of non return valve of following sizers confirming to IS 5312 complete with rubber qasket, GI bolts, nuts, washers, etc. as required.

-

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
125 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
200 mm dia

1

-

-

... More
250 mm Dia

1

-

-

... More
300 mm Dia

1

-

-

... More
Providing installation, testing and commissioning of stainless steel Y Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, Sheet with 3mm dia holes with stainless steel flange.

-

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
200 mm dia

1

-

-

... More
250 mm Dia

1

-

-

... More
300 mm Dia

1

-

-

... More
Supplying and fixing 63 mm dia 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire rivets etc. conforming to IS 6.36 (type-A) as required

-

-

-

... More
Gun metal

1

-

-

... More
Stainless steel (Grade-304)

1

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water house thermaoplastic (Textile) reinforced) type-2 as per IS 12585 20 mm nominal internal dia gun metal globe valve & nozzle Drun and brackets for fixing the equipments on wall Connections from riser with 25 mm dia stop gun metal valve & M.S. pipe and socket.

-

-

-

... More
30 m

1

-

-

... More
40 m

1

-

-

... More
Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required

-

-

-

... More
Gun metal

1

-

-

... More
Stainless steel (Grade-304)

1

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required.

-

-

-

... More
2 way -100 mm dia M.S. pipe

1

-

-

... More
4 way -150 mm dia M.S. pipe

1

-

-

... More
3 way -150 mm dia M.S. pipe

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia. 8 mm thick MS sheet 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories pressure gauge and painting with synthetic enamel paint of approved shade as requred.

1

-

-

... More
Providing, fixing testing & commissioning of 15 mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:

-

-

-

... More
Pendient Sprinkler

1

-

-

... More
Upright Sprinkler

1

-

-

... More
Horizontal side wall sprikler

1

-

-

... More
Concealed Sprinkler

1

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as requred

1

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc. as requred

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm Dia

1

-

-

... More
Providing, fixing testing & commissioning of intallation control valve of cast iron body. Brass/bronze working parts comprising of water motor alarm. Bronze seat ckaooer, clapper arm and hydraulically driven mechanical gong bell to sonund continuous alarm when the wet riser/sprinkler system activaties. pressure gauges. emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass. test control box. ball valves. MS pipe of required size flanges. orifice plate gasket etc. of following sizes as required

-

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm Dia

1

-

-

... More
Supplying installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 Psi test pressure of 875 Psi (Burst) with branch line (Inlet) 25 mm NPT male thread to sprinkler head (Outlet) 15 mm NPT female thread with reducer nipple, 2 side brackets, center braket, stockbar of following sizes complete as required.

-

-

-

... More
700 mm

1

-

-

... More
1000 mm

1

-

-

... More
1200 mm

1

-

-

... More
1500mm

1

-

-

... More
Supplying installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required.

-

-

-

... More
50 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
Supplying installation, testing & commissioning of water curtain nozzle 15 mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.

1

-

-

... More
Supplying installation, testing & commissioning of adjustable rosette plate for 15 mm dia in white finish UL Listed or FM approved complete as requierd

1

-

-

... More
Supplying installation, testing & commissioning of adjustable rosette plate for 15 mm dia in white finish UL Listed or FM approved complete as requierd Note: For cabling earthing and cable trays please refer to DSR (E&M) for digging of hard & soft soil please refer to DSR (Civil)

1

-

-

... More
Operation of Fire Fighting System-

-

-

-

... More
For District Male/Female/100 Baded MCH Wing/other Hospital

-

-

-

... More
Operating Charges of Fire fighting System to keep the fire fighting system working continously pre-installed in hospital building consisting of LT breakers/Switch gear panels Fire Engine Pump, Main Water Pump and Jokey Pump and other fire related equipents etc. Three Experienced Holder Electricians cum fitter will duty eight hours round 'o' clock. Charges for three Electricians cum fitter to operate one fire fighting system in three shifts for 12 months.

1

-

-

... More
For CHC /30 baded MCH Wing/Other Unit

-

-

-

... More
Operating Charges of Fire fighting System to keep the fire fighting system working continously pre-installed in hospital building consisting of LT breakers/Switch gear panels Fire Engine Pump, Main Water Pump and Jokey Pump and other fire related equipents etc. One Experienced Holder Electricians cum fitter will duty eight hours round 'o' clock. Charges for one Electricians cum fitter to operate one fire fighting system in one shifts for 12 months.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.