Defence Research And Development Organisation Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Defence Research And Development Organisation - DRDO Tender

Works
Civil And Construction
Eprocure
Opening Date27 Sep 2024
Closing DateCancelled
Tender Amount₹ 96,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil.

2455

-

-

... More
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m (a) Ordinary rock

100

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.

-

-

-

... More
All kinds of soil

652

-

-

... More
Ordinary or hard rock

50

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift.

7488

-

-

... More
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.

3255

-

-

... More
Supplying and filling in plinth with Sand / M Sand under floors, including watering, ramming, consolidating and dressing complete.

572

-

-

... More
Disposal of surplus excavated earth for leads as mentioned below:-

-

-

-

... More
a) Beyond initial lead of 50m upto 1 Km per Km

1250

-

-

... More
b) From 1 Km up to 2 Km per Km

1250

-

-

... More
c) From 2 Km up to 3 Km per Km

1500

-

-

... More
Supplying chemical emulsion in sealed containers including delivery as specified. (a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

2030

-

-

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
i) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: (a) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.

405

-

-

... More
ii) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: (a) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.

3560

-

-

... More
SUBHEAD - II : CONCRETE WORK

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
(a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).

31

-

-

... More
(b) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).

25

-

-

... More
(c) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

1072

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

25

-

-

... More
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).

101

-

-

... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).

140

-

-

... More
Extra for providing and mixing water proofing material in cement concrete in doses by weigh of cement as per manufacture’s specification.

4020

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

140

-

-

... More
Extra for concrete work in superstructure above floor V level for each four floors or part thereof by mechanical means.

30

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

405

-

-

... More
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (a) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).

50

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin- charge.

50

-

-

... More
Providing and laying cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded brick aggregate 40mm nominal size) in depressed portion of toilets, kitchen and balconies etc.

80

-

-

... More
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. (a) 50mm thick.

150

-

-

... More
SUBHEAD - III : REINFORCED CEMENT CONCRETE WORK

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for.

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete.

1167

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

2808

-

-

... More
Suspended floors, roofs, landings, balconies and access platform.

18331

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.

14079

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.

9380

-

-

... More
Stairs, (excluding landings) except spiral-staircases.

435

-

-

... More
Extra for shuttering in circular work - Columns.

50

-

-

... More
Extra for shuttering in circular work - Walls.

50

-

-

... More
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.

100

-

-

... More
Weather shade, Chajjas, corbels etc., including edges.

322

-

-

... More
Edges of slabs and breaks in floors and walls , Under 20 cm wide.

1975

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). (a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).

5630

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.

1793397

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level.

-

-

-

... More
(a) Concrete of M25 grade with minimum cement content of 330 kg /cum.

85

-

-

... More
(b) Concrete of M30 grade with minimum cement content of 350 kg /cum.

4029

-

-

... More
All works above plinth level upto floor V level.

-

-

-

... More
(a) Concrete of M25 grade with minimum cement content of 330 kg /cum.

6785

-

-

... More
(b) Concrete of M30 grade with minimum cement content of 350 kg /cum.

47

-

-

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

800

-

-

... More
Extra for R.C.C / B.M.C / R.M.C work above floor V level for each four floors or part thereof.

1900

-

-

... More
Providing and fixing 25mm thick expansion joint filler board using Supreme Capcell-HD-100, Semi-rigid UV resistant high performance laminated closed cell polyethelene foam joint filler in sheet form complete as directed.

35

-

-

... More
Providing and fixing in position minimum 20 mm thick bitumen hot sealing compound 20 mm thick and 20mm deep in expansion joints, (Rate will be paid per running meter only).

60

-

-

... More
Providing and fixing in position copper plate as per design for expansion joints.

50

-

-

... More
Providing and fixing sheet covering over expansion joints with iron screws as per design. (a) Aluminium fluted strips 3.15 mm thick. (i) 200 mm wide

40

-

-

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063).

-

-

-

... More
(a) Floor Joint of 100 mm gap.

35

-

-

... More
(b) Floor Joint of 150 mm gap.

140

-

-

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge . The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.)

-

-

-

... More
Wall Joint of 100 mm gap.

25

-

-

... More
Wall Joint of 150 mm gap.

115

-

-

... More
Providing and fixing of expansion joint system of approved make amd manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) Note: Contractor has to get the profile and sample approved by Engineer in Charge before execution of work under items of expansion joint above.

-

-

-

... More
Roof Joint of 100 mm gap.

35

-

-

... More
Roof Joint of 150 mm gap.

50

-

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

2000

-

-

... More
SUBHEAD - IV : MASONRY WORK

-

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (a) Cement mortar 1:6 (1 cement : 6 Coarse sand).

125

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : (a) Cement mortar 1:6 (1 cement : 6 Coarse sand).

100

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (a) Cement mortar 1:4 (1 cement :4 Coarse sand).

100

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

100

-

-

... More
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm to 300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer--in-Charge. (The payment of RCC band and reinforcement shall be made for separately).

3800

-

-

... More
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

500

-

-

... More
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).

405

-

-

... More
Extra for brick work /AAC block masonry / Tile brick masonry in superstructure above floor V level for each four floors or part thereof by mechanical means.

1000

-

-

... More
SUBHEAD - V : STONE WORK

-

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand).

450

-

-

... More
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 Coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.

-

-

-

... More
Red sand stone.

10

-

-

... More
White sand stone.

10

-

-

... More
Wall lining butch work upto 10m height with Dholpur stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width, including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75 mm and by providing layer of 75 mm thick strips i/c 12 mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand) i/c ruled pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge.

320

-

-

... More
SUBHEAD - VI : STEEL WORK

-

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

100

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

2250

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

-

-

-

... More
(a) Hot finished welded type tubes.

200

-

-

... More
(b) Hot finished seamless type tubes.

7600

-

-

... More
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

150

-

-

... More
Providing and fixing bolts including nuts and washers complete

50

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete.

3257

-

-

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

250

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (a) M.S. tube.

250

-

-

... More
SUBHEAD - VII : JOINERY

-

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood.

6

-

-

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. (a) Using M.S. angels 40x40x6 mm for diagonal braces

10

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. (a) 80x1.25 mm M.S. laths with 1.25 mm thick top cover.

10

-

-

... More
Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. (a) Exceeding 10.00 sqm and upto 16.80 sqm in the area.

10

-

-

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-Charge, (area of grill to be measured).

5

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified including fixing with adjustable lugs with split end tail to each jamb and filling in the frame cement concrete 1:3:6 by using 20mm and down graded metal complete, applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: (a) Profile C

600

-

-

... More
Providing and fixing of Hollow metal General purpose door at all levels from ISO 9001-2000 certified Manufacturer with or without vision panel. Pressed Galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Single rebate profile of size 100 x 58 mm made out of 1.20mm thick galvanised steel sheet (18 gauge). Frames should be Mitered and field assembled with self tabs. Door leaf should be 46 mm thick , double skin door shell and manufactured from 0.80 mm thick galvanised steel sheet (22 gauge). The infill material shall be resin bonded honey comb paper glued and sandwiched in between with an interlocking arrangements. Vision lite wherever applicable should be of size 150mm x 750mm. All doors should be factory preped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonary opening.

-

-

-

... More
Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 guage) thick galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be asper joinery details with a screw on glass beeding on the inside. The glass should be 5mm clear toughened glass. Louvers when recommended should be site proof and shall be flush fixed on the external surface. All doors and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved RAL colour. The door leaf and frame shall have passed minimum 250 hours of salt sprey test. Rate should include supply and installation of door and all other hardware etc all complete. (a) For doors upto 3.0m height.

221

-

-

... More
Providing and fixing factory made ISI marked uninsulated metal fire rated doorset assembly for all non egress application areas like shafts etc consisting of galvanized iron steel frame and double leaf shutter, including necessary hardware accessories conforming to FD 120 classification of IS 3614 : 2021 with fire rating of 120 minutes integrity. The door frame and shutter shall be made out of minimum 1.2mm thick GI sheet with minimum 120GSM Zinc coating as per IS:277. The entire fire rated doorset assembly shall be tested as per IS : 17518 (Part -1) ; 2022 Frame : The frame shall be of minimum size 90 x 60mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joints (self tab screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS : 4351. The smoke seal material shall be of EPDM or any other material tested in accordance with BS 476 (Part - 22) ASTM E-84 of minimum size 10mm x 4mm , fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed in all four sides of masonry wall opening with CSK headed fasteners of minimum 8mm dia size and minimum 80mm long hot dip galvanized with 8mm dia polyamide sleeves @ 4 numbers at each on vertical sides (upto 2100mm height) and 2 numbers each on top and bottom sides.

-

-

-

... More
Door Shutter : The double skin double leaf door shutter shall be consisting of minimum 46mm thick and having box like structure, slots cut and holes punched for fixing hardwares with stiffeners as per IS:16074, including resin bonded honey comb paper core infill material of density 5kg/cum. Integral astragats to be provided on meeting styles of double leaf door, each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing hinges as per EN : 1935 : 2002 or butt hinges as per IS : 12817 both of minimum size 100 x 75 x 3mm @ 4 numbers hinges per door leaf upto 2100mm / 2400mm height or as per test evidence, which ever is more, fixed with M625 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. Accessories Hardware : Fire doorset shall be provided with one number fire rated SS 304 grade shaft mortise dead lock, one number 50mm to 80mm backset with minimum 20mm square forend with allen key including SS 304 dead strike plate comforming to EN12209. Two numbers recessed flush pull handle (SS 304) of minumum size 40mm x 120mm. one number 300mm long concealed lever action flush bolt(dye cast stainless steel finish) at bottom with SS dust proof socket and one number minimum 300 mm lomg concealed flush bolt (dye cast stainless steel finish) at top of inactive leaf of double door , as approved by the Engineer-In - Charge. (a) For doors upto 3.0m height with Clear fire rated vision glass 6mm thick of size 200 x 300mm, S.S.Butt hinges, external lever handle, door closer with standard arm, panic bar, S.S. Gasket fire rated,smoke seal etc complete.

75

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

140

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

135

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) laminated type, core of block board construction with frame of 1st class hard wood and fixing 1mm thick laminate (of approved colour) on both faces of shutters. (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

130

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) laminated type, core of block board construction with frame of 1st class hard wood and fixing 1mm thick laminate (of approved colour) on one face and 0.8mm thick balancing laminate on other face of shutter. (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

75

-

-

... More
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) (a) On one side only

25

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

480

-

-

... More
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): (a) Rectangular or square.

100

-

-

... More
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

50

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (a) 4.0 mm thick glass panes.

25

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (a) Fixed to steel windows by welding

1020

-

-

... More
Providing 40x5 mm flat iron hold fast 400mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150mm 1:3:6 mix (1 cement : 3 Coarse sand : 6 graded stone aggregate 20mm nominal size).

775

-

-

... More
Providing and fixing Dead Lock with 55mm backset, 20mm square forend prepared for euro profile cylinder including strike plate and EPC 60mm length, both side key operation & Escutcheons in SSS Finish of model no : 278a of Dormakaba or equivalent.

129

-

-

... More
Providing and fixing pull Handle of length 300mm and 22mm dia, made of SS 304 grade, of model no : TGDI-D300 of Dormakaba or equivalent, single side with adjustable fixing for wood and metal doors in satin stainless steel finish. The pull handles shall have supporting washer with raised bevelling on the outer surface.

129

-

-

... More
Providing and fixing rack and pinion door closer of model no : TS 68 of Dormakaba or equivalent, EN size 2/3/4, with std. arm and with two independent closing valves and latching speed adjustable by arm, Silver finish and as per EN 1154.

245

-

-

... More
Providing and fixing floor stop half dome in satin Chrome, of model no : 3108 of Dormakaba or equivalent, 45mm dia with fixing accessories.

129

-

-

... More
Providing and fixing door lock cum handle of model no : Pure 8100 of Dormakaba or equivalent ,Type 3 Package with Pair of Pure 8100 Design Lever Handle on Roses & escutcheons, including 271a Sash lock with 72mm CTC, 55mm Backset 20mm Square forend, EPC 60mm length oneside thumb turn otherside coin release operation.

116

-

-

... More
Providing and fixing wall mounted door stop with coat hook in SSS finish of model no : 4014 of Dormakaba or equivalent with fixing accessories.

116

-

-

... More
Providing and fixing door lock cum handle of model no : Pure 8100 of Dormakaba or equivalent, Type 3 Package with Pair of Pure 8100 WC Design Lever Handle on Roses & escutcheons 7122, including 275a WC lock with 78mm CTC, 55mm Backset 20mm Square forend.

2

-

-

... More
Providing and fixing Grab Bar for wall fixing of Length 305mm, 25mm Diameter in Satin stainless Steel Finish of Dormakaba model no : GBDI D-300 or equivalent.

4

-

-

... More
Providing and fixing cam action door closer with slide channel arm, Silver finish of model no : TS 90 of Dormakaba or equivalent, Spring size EN 3/4 as per EN 1154 and CE marked.

2

-

-

... More
Providing and fixing disable sign plate of model no : 3040-D of Dormakaba or equivalent, for WC application with fixing screws size 125 x 125mm, rounded corners in SS 304 satin stainless steel finish and marking in black.

2

-

-

... More
Providing and fixing Coat hook of model no : 3106 of Dormakaba or equivalent with face fixing screws in satin stainless steel finish.

2

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.

5

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

5

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (a) With stainless steel cover plate minimum 1.25 mm thickness.

8

-

-

... More
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge.

20

-

-

... More
Providing and fixing to existing door frames. 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S.galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.

10

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

4750

-

-

... More
Providing and fixing toilet partitions of size upto 1200mm x 1500mm and 2000mm height made of 12mm thick solid compact laminate board (Phenolic core board) based on thermosetting resins, homogeneously reinforced with cellulosefibres . The intermediate panel shall be one continued panel without any joints. All intermediate panels, panels, pilasters and doors shall be 12mm thick with edges chamfered.Frame work shall be with SS coated aluminium U channel for fixing the intermediate panel to the wall and also for fixing the door. All pilasters shall be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with exterior polyamide coating and shall guarantee resistance to breakage, heat, humidity and chemicals. The base of the adjustable foot shall be anchored to the floor with a clearance height of 100mm .The top surface shall be melamine coated on both sides and shall be scratch and impact resistant. Each toilet compartment shall be equipped with accessories in stainless steel smart series privacy thumb turn, door knob, coat hook, auto return hinges, adjustable legs, SS coated aluminium top profiles etc., all complete

50

-

-

... More
Sound Reducing-fire retardant door for Auditorium

-

-

-

... More
Supply and fixing of 83mm thick wooden acoustic cum fire / smoke check door of 120 minutes fire rating and with 38 dB noise reduction, made of 2nd Class Teak Wood door frame of section 145mm x 90mm , fixed to the wall with holdfasts, with heat activated intumescent fire seal strip of size 10mm x 4mm (Marshall /Raven ) fixed alround the door frame. Shutter shall be of 83mm(+-2mm ) thick having 38 dB acoustic , noise reduction properties cum fire door of 120 min. fire rating.The door shutter shall be made of 68 x 80mm thick hard wood internal frame work (hardwood red marrandi) having infill of 47mm thick resin bonded glass wool of 24kg /cum density with FR Acrylic Sealant ( SDHL / Pemko ) sandwiched between two 9mm thick only Starpan Calcium Silicate boards , which shall be 100% without asbestos, Brucite and Meerschaum. The density of the boards shall not be more than 950kg/cum and thermal conductivity 0.14 W/m*K. The boards shall be faced with 6mm thick commercial ply ( Century / Green ply ) along with 1.5mm thick laminate facing / 3mm Decorative Veneer final finish.The shutter shall be provided all around with heat activated intumescent fire seal strip of size 10mm x 4mm( Marshall/Raven) mounted in the grooves having teak wood lipping of size 15x83mm. The acoustic wooden door assembly shall have heavy duty 2 nos. automatic concealed spring loaded, self-levelling door bottom seals (Marshall / Pemko) and 3 nos. heavy duty full length exposed door jamb seal (Marshall / Pemko). The entire assembly would be prior tested from CBRI Roorkee for double leaf configuration as per IS: 3614 (Part 2, meeting insulation criteria) and BS 476 (Part 20 & 22). The CBRI Roorkee test report should not be older than 5 years and shall clearly reveal the thickness of the calcium silicate board, laminate , ply and the panic hardware, acoustic seals and the door closer that it was tested with and the same shall be submitted to the Engineer -in-charge for approval of the specialzed agency prior to manufacturing. (The rated quoted shall be including fixing with necessary accessories but excluding hardware which shall be paid separately under relevant item).

10

-

-

... More
Providing & fixing stainless steel 304 grade fire rated ball bearing hinges of size 102mm x 76mm x 3mm thick from Dorma BB4330/ Ingersoll Rand "Brition " / Marshall Make. of 2hrs. Fire rated , CBRI tested as per IS 3614 Part - 2 and BS 476 Part - 22

10

-

-

... More
Providing & fixing exturded aluminimum body heavy duty 2 hrs fire rated door closer of Dorma's TS 93 , Brition's LCN1460 and Marshall MH-DC-S-14016 , tested from CBRI Roorkee as per IS : 3614 Part -II and BS : 476 Part 20& 22 from CBRI Roorkee along with wooden /glazed / metal fire doors. The door closer shall be of type 1-6 , non handed having back check function , ANSI/BHIMA certified , and shall comply with EN 1154 for 100000 cycles with full body stainless steel cover.

2

-

-

... More
Providing and fixing door lock cum handle of model no : Pure 8100 of Dormakaba or equivalent, Type 3 Package with Pair of Pure 8100 WC Design Lever Handle on Roses & escutcheons 7122, including 275a WC lock with 78mm CTC, 55mm Backset 20mm Square forend. (a) For Double Leaf

2

-

-

... More
Providing & fixing stainless steel 304 grade external trim (Latch & Lock) with 3 keys for providing outside access for panic bar of approved make Marshall MH-PB- SS- 11002 SS / Dorma 's PHX 03 / Von Duprin's CX 98 series for wooden /glazed / metal fire doors. all complete as per manufacturer's specifications, approved drawing and direction of the Engineer- in- charge.

2

-

-

... More
Providing and fixing satin stainless finish Mortise Dead Lock with 80mm both side key cylinder of Dorma’s 288 Series, Briton’s EL 2010, Marshall’s MH-L-13002, European standard tested to 100000 cycles of approved make and tested along with the Wwooden /glazed / metal fire doors for 2 hrs. fire rating from CBRI Roorkee.

2

-

-

... More
Providing wall panelling of Armstrong Industries or approved equivalent make as per specification and direction of EIC at all heights and levels.

-

-

-

... More
Providing and Fixing Channelled Woodworks perforated panels for wall panelling of Armstrong Industries or approved equivalent make of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 21mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Armstrong or equivalent and approved by the Architect/ Engineer-in-Charge.

250

-

-

... More
Providing and fixing ‘Optra Acoustical Wall Paneling - Fabric wrapped’ of Armstrong or approved equivalent make with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class B-s1, d1 as per EN13501, fabric with an option of colors – Ivory, Autumn Orange, Pista Green, Straw Gold, Rustic Green, Burgundy, Rust, Peacock Blue, Ash Grey, Mocha as per the choice of the Architect of size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt. Ltd and construction adhesives as per the instructions laid down by the manufacturer.

250

-

-

... More
SUBHEAD - VIII : FLOORING

-

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (a) 40 mm thick with 20 mm nominal size stone aggregate.

3027

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

240

-

-

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (a) 18 mm thick.

55

-

-

... More
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.

10

-

-

... More
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.

100

-

-

... More
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (a) 40 mm wide and 4 mm thick.

100

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.

-

-

-

... More
(a) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand). Acid and alkali resistant tile.

3635

-

-

... More
(b) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand). Acid and alkali resistant tile

1400

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (a) 25 mm thick.

575

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

100

-

-

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab

400

-

-

... More
Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre.

180

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : (a) Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

1005

-

-

... More
Providing and laying Polished Granite Stone work for skirting, risers of steps over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 Coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.

330

-

-

... More
Providing grooves in treads of granite steps, 3 Nos. In each tread of width 6mm and depth 6-8mm (Effective area of Tread shall be measured for payment) .

65

-

-

... More
Providing and fixing 18 to 20mm thick Polished Granite cladding with edge chamfering whereever required of approved shade stones of required size, backing with a grout of Latricrete or approved equivalent of 12mm or required thickness with an admixture of pigment matching the stone shade complete for all heights and lifts as per drawing and directions of Engineer-in-charge.

200

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : (a) Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent.

3585

-

-

... More
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (a) 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.

330

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

50

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 400x400 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

50

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600 x 600 mm.

2085

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. (a) Size of Tile 600x600 mm.

130

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.

-

-

-

... More
(a) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble. Area of slab over 0.50 sqm.

30

-

-

... More
(b) Granite stone slab of colour black, Cherry/Ruby red. Area of slab over 0.50 sqm

200

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.

-

-

-

... More
(a) Marble work.

35

-

-

... More
(b) Granite work.

300

-

-

... More
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

335

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

140

-

-

... More
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :

-

-

-

... More
(a) Makrana white second quality.

420

-

-

... More
(b) Udaipur green marble.

420

-

-

... More
Extra for pre finished nosing to treads of steps of marble stone.

30

-

-

... More
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.

15

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1860

-

-

... More
Providing and fixing of Laminated wooden flooring & skirting (thickness as per manufacturers specifications), classification of use 33/23 with a surface abrasion resistance of class AC5 (average 6500 cycles), impact resistance of 7.7mm, resistance to cigarette burn with a rating of class 184(EN 438-2:05), swelling after 24 hrs in water of 8.22%, Modulus of rupture of 53.3 newton/mm2, Internal bond 1.78 newton/mm2, surface soundness 2.62 newton/mm2 (EN 13329:2000) with a 0.2 mm thick wear layer on top of a High Density Fiber substrate core (density ~ 948.3 Kgs/M3) of plank size 1200 mm x 125 mm x (thickness as per manufacturers specifications) having locking arrangement (lock strength 1100 lbs/ft) with an underlayment made of natural colour foam, with accessories like End profile, Transition profile, reducer, Stair nosing etc. complete. INSTALLATION: It is important to ensure the sub floor on which the laminate is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the same should be levelled by self levelling compound. The moisture level present in the subfloor should be less than 8% before installation of the floor. It is recommended to use a water barrier of minimum of 250 microns and 2mm polyethylene foam under the planks. The installation shall be undertaken as per the manufacturer’s installation instructions

2670

-

-

... More
Providing and fixing roll carpet / plank carpet of approved make , firmly anchored to a waterproofing backing with an underlayer of 6mm thick foam wall of density of 70 million fibres of nylon 6.6 per sqm. Carpet layers of non woven manufacturing with a thickness of 5.3mm available in plank size of 100 cm x 25 cm. Commercial use as per EN-ISO 10874 : Class 33 Heavy, with resilient waterproof backing , anti static., with a weight of 5.4 kg/M2 as per ISO 8543, abrasion resistance of 1000 cycles and sound absorbtion of 20 dB. The product - Flocked Carpet must be ZERO EMISSION Carpet and should have a green manufacturing certificate having average recycled contents of 67% by weight. To be flame resistant and have non toxic fume emission on burning. Reaction to fire as per EN 13501-1 : Bfl-s1, along with the thermal conductivity as per (ISO8302). Instalation shall be done by Low VOC factor 4 adhesive complete to the satisfaction of Engineer-in-Charge.

380

-

-

... More
Wooden Flooring on Auditorium stage

-

-

-

... More
Providing and installing wooden flooring with European white Oak, 18mm thick and width 123mm, with length as per manufacturer availability, natural grade (each plank unique with possible knots & colour variations), finished with durable and scratch resistant PU coating. The wooden planks shall be dried to a wood moisture level of 9 ± 2% and shall be bevelled alround for better edge protection and style. The planks shall be provided with tongue and groove joints for easy installation and shall be nail down to sub floor of water proof and pest proof 12mm thick plywood. The rate shall include cost of planks and plywood, all accessories necessary for installation, labour charges etc., complete as per the instruction of Engineer-in-Charge.

180

-

-

... More
Providing and fixing 145 x 50mm teakwood moulding made of second class teak wood, on the edges of stage wooden flooring including wax polishing of teak wood planks after filling wood filler and sand papering up to smooth finish in natural colour etc all complete as per the architect and to the satisfaction of Engineer-in-Charge.

60

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

75

-

-

... More
Providing and applying 2mm thick ESD (Antistatic Flooring) of approved make, with Surface resistance(BS 2050 5x104 Ohms and shall confirm to Technical properties mentioned below Compressive strength 60 N/mm2 , Volume solids 100% (BS 6319), Tensile strength (BS 6319) 16 N/mm2, Flexural strength (BS 6319) 40 N/mm2, Temperature resistance Upto 80 degree Centigrade . Flooring System shall consist of 1 coat of Primer (Nitoprime 25 of Fosroc or approved equivalent),Copper tape laying in a grid size not less than 3mtr X 3mtr ,1 layer of Under coat (Nitoflor SL Conductive of Fosroc or approved equivalent ) and 1 layer of Top Coat (Nitoflor SL Conductive of Fosroc or approved equivalent ) etc all complete as per manufacturer specification.

500

-

-

... More
Supplying and laying 125 microns plastic sheets below RCC

500

-

-

... More
Making grooves, 5mm wide and 12mm deep in concrete (VDF) / screed flooring with mechanical cutter and filling and sealing the same with polysulphide sealant of approved make through an authorized applicator including all material, labour etc., complete.

230

-

-

... More
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:- a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.

-

-

-

... More
c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and, an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. (a) 450 mm Finished Floor Height (FFH).

95

-

-

... More
SUBHEAD - IX : ROOFING

-

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of total coated thickness 0.50 mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1086

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :

-

-

-

... More
Ridges plain (500 - 600mm)

100

-

-

... More
Flashings/ Aprons.( Upto 600 mm)

200

-

-

... More
Gutter (600mm overall girth)

200

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

47

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm diameter

25

-

-

... More
160mm diameter

920

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c ) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.

-

-

-

... More
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e ) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

3595

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).

1000

-

-

... More
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

1000

-

-

... More
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.

130

-

-

... More
Providing and fixing GI pipes (Class B) including fittings i.e. elbow, socket, tee etc and MS clamps and including painting with anticorrosive bitumastic paint, cutting chases (if required) and making good the wall etc all complete as directed - 100mm diameter.

40

-

-

... More
Providing and fixing 50mm dia GI spout set in cement mortar 1:3 (1 cement : 3 coarse sand ) complete.

23

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

44

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 20 cm x 20 cm and weighing not less than 995 grams.

5

-

-

... More
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)

1900

-

-

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (a) With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7).

3790

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (a) GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595 x 595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.

3790

-

-

... More
Providing & Fixing of Wooden finish Suspended Ceiling System with WOODWORKS (MICRO LOOK) EDGE TILES of approved make WITH XL 15 MM EXPOSED GRID. The tiles shall be of perforation pattern R3/R3B/R6/O6/O11/O12/SQ01 perforation with approved laminate/natural veneer finish and shall have Humidity Resistance (RH) of 90%, Fire Performance Class 1(BS - 476) in module size of 600mm x 600mm x 12mm The grid shall consists of 15mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 43mm and a load carrying capacity of 23.71 Kgs/M2. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test. The Tile & Grid system used together should carry a 15 year warrantee. INSTALLATION: Shall comprise main runner spaced at 1200mm centers securely fixed to the structural soffit using suitable suspension system (specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be of wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centers. SUSPENSION SYSTEM accessories manufactured and supplied by approved make consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanized steel of size 26 x 26 x 25 x 1.2mm with a Galvanized Thickness of 80gsm, A pre Straightened Hanger wire of die – 2.68 mm of 1.83 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanized spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner.

200

-

-

... More
Supply and Installation of false ceiling Anutone Strand1 Colour or equivalent make , Square edge, magnesite-bonded pinewood fibre 1mm width core, factory prepainted, ceiling tile of size 595x595x15mm, volume density 400Kgs/m3, weight 6kg/m2 which is suspended by using 0.3mm thick Anutone Skelet Trelis T24 ceiling grid system or approved equivalent. Anutone Skelet Trelis T24 ceiling grid system shall consist of 600x600mm module includes Anutone Skelet WA24W30 wall angle with equal flanges of 24mm, length 3000mm,0.4mm thk, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centres. Then suspend the Anutone Skelet MT24W36 MainT with flange width 24mm, height 38mm and length 3600mm, from the soffit slab with help of anchor bolt, soffit cleat and wire rod with leveling clip at 1200mm centres. Anutone Skelet CT24W12 CrossT with flange width 24mm, height 32mm and length 1200mm is interlocked into the pre-cut slots in the Main T24 at 600mm centers in the perpendicular direction to the Main T24. Finally Anutone Skelet CT24W06 CrossT with flange width 24mm, height 32mm and length 600mm are interlocked into the pre-cut slots in the CT24W12 CrossT in direction parallel to the Main T24 to result in 600x600mm module. Anutone Strand1 Colour ,square edge, of size 595x595x15mm shall be placed into the grid size of 600x600mm. The system is backlined with the acoustical infill Anutone SynthPF 10x50.(The Skelet Trelis T24 ceiling grid system can be in same shade as Strand1 Colour panels,or as per architect choice). Technical Parameters • Fire (Class) – 1 & P • Acoustics – NRC upto 0.9 • Thermal (W/mk)– 0.07 • Climate (°C, RH) – 50, 95 • Light (%) – Colour Dependant • Green (VoC, RC %) – Low, 30

360

-

-

... More
Note: The rate quoted shall include the cost of making opening for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of Engineer-in-charge

-

-

-

... More
SUBHEAD - X : FINISHING WORKS

-

-

-

... More
Providing and applying 12 mm cement plaster of mix : (a) 1:6 (1 cement: 6 fine sand)

1700

-

-

... More
Providing and applying 15 mm cement plaster on the rough side of single or half brick wall of mix: (a) 1:6 (1 cement: 6 fine sand).

600

-

-

... More
Providing and applying 12mm thick (average) premixed formulated one coat gypsum light weight plaster having additives and light weight aggregates as vermiculite / perlite respectively conforming to IS: 2547 (Part - I & II) 1976, applied on hacked / uneven background such as bare brick / block / RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc complete.

33100

-

-

... More
Providing and applying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.

-

-

-

... More
Above plinth level up to 10 mtr.

4485

-

-

... More
From 10.0 mtr upto 13.0 mtr.

1000

-

-

... More
From 13.0 mtr upto 16.0 mtr.

1000

-

-

... More
From 16.0 mtr upto 19.0 mtr.

1000

-

-

... More
From 19.0 mtr upto 21.0 mtr.

1000

-

-

... More
From 21.0 mtr upto 24.0 mtr.

1000

-

-

... More
From 24.0 mtr upto 27.0 mtr.

1250

-

-

... More
From 27.0 mtr upto 30.0 mtr.

500

-

-

... More
Providing and applying 6 mm cement plaster of mix. (a) 1:3 (1 cement : 3 fine sand)

15275

-

-

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

30

-

-

... More
Providing and applying 20mm thick plastering in sumps / OHT / Drains and similar locations with cement mortar 1:3 (1 cement: 3 coarse sand) with water proofing compound mixed as per manufacturer instruction, a floating coat of neat cement including benching, haunching, providing over flow pipes and proper slopes, all as directed by Engineer-in-charge. (including cost of water proofing compound).

1690

-

-

... More
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : (a) Flush/ Ruled pointing.

110

-

-

... More
White washing with lime to give an even shade : (a) New work (three or more coats).

100

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram / litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. (a) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.

800

-

-

... More
Finishing walls with water proofing cement paint of required shade : (a) New work (Two or more coats applied @ 3.84 kg/10 sqm).

100

-

-

... More
Finishing walls with textured exterior paint of required shade : (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).

3500

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : (a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre/10 sqm).

7100

-

-

... More
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

8875

-

-

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (a) Two coats.

35115

-

-

... More
Providing and applying interior textured paint of Altek Super fine or approved equivalent anti fungal, anti rusting, anti foaming, with excellent acrylic synthetic binders and plasticizers with particle size upto 100 microns in two coats to give ultra smooth surface by spatula followed by two coats of Altek Flora or approved equivalent Plastic Emulsion in desired shade over a coat of Cement primer as per specification of approved manufacturer and texture as approved by Engineer-in-charge including the cost of all materials, labour, surface preparation, impliments etc., in all floors at all heights as required to complete for the finished item of work.

5000

-

-

... More
Providing & fixing chiken mesh at the junctions of RCC and brick work, 100mm overlapping on both sides with all necessary hardware etc., complete.

330

-

-

... More
Applying priming coat.

-

-

-

... More
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

335

-

-

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

400

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (a) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

735

-

-

... More
Melamine polishing on wood work (one or more coat).

350

-

-

... More
SUBHEAD - XI : ALUMINIUM WORKS

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion (a) Powder coated aluminium (minimum thickness of powder coating 50 micron).

1590

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (a) Powder coated aluminium (minimum thickness of powder coating 50 micron).

1590

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in- charge. (a) Pre-laminated particle board with decorative lamination on both sides.

20

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With frosted glass panes of 4.0 mm thickness (weight not less than 10kg/sqm).

20

-

-

... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm).

320

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (a) Upto 5mm depth and 5 mm width.

785

-

-

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. (a) Powder coated minimum thickness 50 micron aluminium tubular handle bar.

359

-

-

... More
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. (a) Powder coated minimum thickness 50 micron aluminium.

359

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture , including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

10

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.

7500

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO / IEC 17025 (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr. (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml. (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm. (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml.

1000

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item above“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (a) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

1000

-

-

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

100

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

300

-

-

... More
Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 250/ 300/ 400mm and length of 595 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework(Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L'(for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 600mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x25x2mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/ c matching to the tile horizontal grid with two numbers of selfdrilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns)of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be additionally secured to the horizontal ‘C’ clamps using special SS clips of required size which shall be inserted and pressed into position on the ‘C’ clamps holding the tiles and the cuttiles shall be glued at points to the horizontal ‘C’ clamps by using MS Polymer sealant adhesive. The vertical joint open groove between two adjacent tiles shall be 5mm.

-

-

-

... More
The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-inCharge. Note : Scaffolding wherever required to be paid separately. (a) With 16mm thickness (+/- 10%) terracotta tiles of grey colour.

500

-

-

... More
Providing and fixing skylight system made of framework with aluminium 52mm module mullion transom grid with thermal break properties, assembled square cut with ensured drainage continuity. Profiles shall be dimensioned according to design criteria. Infill shall be with 24 mm thick glass made of 6mm thick reflective glass + 12mm air gap + 6mm thick heat strengthened glass) , maintained vertically by a pressure plate and horizontally by glass roof capping pressure blocks. Glass shall be 4 edged or 2 edged according to DTU standards. The whole system shall be supported on MS frame structure. Collection and drainage of any water ingress shall be via profile rebate. Internal water proofing shall be with EPDM gasket. Externally, a butyle strip on mullions and transoms shall be used, or a foam seal + silicon weatherproofing on transoms for vertical line effect finishes. Horizontally, pressure block in the centre of the free edge shall be provided which holds infills for maximum deflection requirements exceeding 2mm. Minimum slope of 15 degrees shall be maintained. Roof opening vents may be integrated: 6 - 30mm glazing with 60 degree electronically controlled. The rate quoted shall be for supply & installation of whole system including all accessories required except MS frame work which shall be measured and paid separately under the relevant item.

260

-

-

... More
SUBHEAD - XII : SANITARY INSTALLATIONS

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (a) W.C. pan with ISI marked white solid plastic seat and lid.

113

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

7

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

64

-

-

... More
Supply, Installing, testing and commissioning EWC & concealed Cistern (2/4 dual flush) complete with fittings & seat cover for Physically Challenged with increased height for convenience with 'P' or 'S' trap with cistern with raised soft- push button for convenient access, with grab bars and hinged bars necessary for physically challenged toilets with all internal parts for efficient functioning with polypropylene solid hard seat and cover of with polythene buffers and flap, brass CP wall flanges, brass CP bolts and nuts 15mm brass CP angle valve, 450 mm long inlet (type) connection pipe, all HINDWARE Cat 70002 or Equivalent model from Parryware, (Wash basin 46 x 36 with one pair mounting brackets, ewc & cistern complete with fittings & seat cover, one no. Hinged rail 76 cm & 5 nos. of grab rails 60 cm COMPLETE) with mounting chair bracket custom made to specific dimensions as mentioned by the architect / engineer, fixing of 110mm dia straight type straight syphon UPVC WC pan connector with neoprene rubber ring and necessary accessories etc., complete. (All fittings of approved make). Supply and fixing of vitreous china oval type wash basin for Physically Challenged of HINDWARE MAKE, make colour, with cold water supply connecting pipe with angular stop cock, CP waste coupling with plug chain, 32mm dia CP bottle trap, etc of approved make. The work shall include cutting and making good the walls and floors complete. Supply and fixing of 15mm dia CP pillar cock with aerators / flow restrictors. The work shall include cutting and making good the walls and floors. (All fittings of PARRYWARE MAKE or Equivalent model from Jaquar) (Flow rate - 1.3 LPM @ 58 PSI)

2

-

-

... More
Providing and fixing Wash Hand Basin Rectangular type comprising of; a) Glazed vitreous china below counter Rectangular shaped wash basin of approved brand/ make, shape, size and pattern of (Jaquar make, Model No.CNS-WHT-701 or Equivalent model from Parryware / Hindware). b) One Aquisense sensor faucet for wash basin with base flange (Jaquar make, Model No.SNR-CHR-51011 or Equivalent model from Parryware / Hindware). c) One 15mm heavy quality flexible PVC inlet pipe connection with C.P.brass hexagonal check nuts with washers at both ends. d) One 15mm Angle Stop Cock (Jaquar make, Model No. KUP-35053PM or Equivalent model from Parryware / Hindware) on the inlet to the basin. e) One 32mm heavy quality CP brass waste coupling with rubber plug and CP chain (JAQUAR-ALD-709 or Equivalent model from Parryware / Hindware). f) Bottle Trap of JAQUAR Code No. ALD-769L or Equivalent model from Parryware / Hindware with internal parttion, 32mm size with 300mm and 190mm long wall connection pipes and wall flange. g) 32mm PVC waste pipe with specials from extension piece of the bottle trap to the floor trap, length not exceeding 1mtr.concealed in the wall.

10

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (a) White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.

167

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (a) Kitchen sink with drain board. 510x1040 mm bowl depth 200 mm

16

-

-

... More
Supply and fixing of Health Faucet (ABS Chrome Plated) of the closet mounting type with hose, hand shower (Health Faucet) with 8mm Dia 1.2m long Flexible tube and Wall Hook with complete fittings of JAQUAR make - ALD-565 or Equivalent model from Parryware / Hindware. (All fittings of approved make).

120

-

-

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (a) 100 mm diameter.

8

-

-

... More
Providing and fixing 6mm thick frameless mirror fixed to the wall / tiles with wall anchors, glue and mirror clips screws including all incidentials etc all complete as directed by engineer-in-Charge.

164

-

-

... More
Providing and fixing in position Hand dryer of Jaquar- Code No. HDR-SAP-M06ACS or Equivalent model from Parryware / Hindware, made of AISI 304 stainless steel and satin finish etc., complete all as specified and directed by EIC

10

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (a) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

24

-

-

... More
Providing and fixing in position Towel Ring of Jaquar- Code No. AQN-7721 or Equivalent model from Parryware / Hindware with necessary CP screws and TW plugs fixed to wall complete all as specified and directed by Engineer In Charge.

152

-

-

... More
Providing and fixing in position Toilet paper roll holder with flap recessed type (Jaquar Code No. AKP-35753PS) or Equivalent model from Parryware / Hindware with necessary CP screws and washers fixed to wall, fixing and making good the surface etc; complete all as specified and directed.

120

-

-

... More
Providing & fixing in position CP brass twin coat hook including cutting necessary CP brass screws etc complete.

84

-

-

... More
Supply and fixing C.P. brass long nose Sink cock with Swinging Casted Spout of Jaquar make Model No. CON-349KNM / Parryware / Hindware or approved equivalent make (Table mounted Model) with complete fittings of approved make. (Flow rate - 6 LPM).

277

-

-

... More
Supply and fixing of Bib Cock (Straight line Model) with wall flange of Jaquar make, Model No. KUP-35041PM / Parryware / Hindware or approved equivalent make with complete fittings of approved make. (Flow rate - 6 LPM).

154

-

-

... More
Providing, fixing, testing and commissioning of CP brass angle valve with CP wall flange, nut and washers etc., complete as required (KUP-35053PM or equivalent).

350

-

-

... More
Providing and fixing in position soap dish Jaquar- Code No. AQN-7731 or Equivalent model from Parryware / Hindware with necessary CP screws and washers fixed to the wall etc. Complete all as specified.

158

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (a) 15mm nominal bore.

265

-

-

... More
Providing & fixing in position CP Towel rack.

25

-

-

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : (a) Single half stall urinal with 5 litre P.V.C. automatic flushing cistern.

10

-

-

... More
Providing and fixing urinal partition made of glass of width 400mm and height 900mm, made of 5mm thick clear heat strengthened glass + 0.76mm clear PVB + 0.38mm milky PVB + 5mm clear heat strengthened glass, fixed to the wall with stainless steel (SS-304 grade) accessories like L clamp with SS screws etc all complete to the satisfaction of Engineer-in-Charge.

70

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (a) Semi rigid pipe. 40 mm dia.

309

-

-

... More
Providing, fixing, jointing and testing in position of ISI marked UV stabilized uPVC pipes for soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (conforming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, expansion joints / belows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall conform to IS:5382. The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by the Engineer-in-charge at site..(Specials at Junction of lateral pipe and vertical stack must have access door for inspection).

-

-

-

... More
(a) 75 mm diameter.

600

-

-

... More
(b) 110 mm diameter.

1100

-

-

... More
Providing and fixing UPVC floor trap with 75mm dia outlet "Supreme" or Equivalent model from Parryware / Hindware, including connection with PVC soil / waste pipe, necessary 150mm thick CC 1:2:4 for embedding the trap including providing and fixing top rail and strainer on top of the trap etc. complete all as per specifications and as directed by the Engineer in-charge.

80

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (a) 180x150 mm size P type. With Sewer bricks conforming to IS : 4885.

12

-

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: (a) Inside dimensions 455x610 mm and 45 cm deep for single pipe line; With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

12

-

-

... More
Supply and Installation of 15 litres (5Star Rated) storage type water heaters with 2KW heating element fixed on wall/column with necessary bracket including all installation materials, fixing of inlet/outlet water pipes, interconnections as required , labour for fixing etc all complete to the satisfaction of Engineer-in-Charge.

48

-

-

... More
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (a) Size 600x450x200 mm.

80

-

-

... More
SUBHEAD - XIII : INTERNAL WATER SUPPLY

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, iicluding cutting and making good the walls etc. Internal work - Exposed on wall

-

-

-

... More
25 mm dia nominal bore.

500

-

-

... More
32 mm dia nominal bore.

250

-

-

... More
40 mm dia nominal bore.

150

-

-

... More
50 mm dia nominal bore.

100

-

-

... More
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :

-

-

-

... More
15 mm dia nominal bore.

400

-

-

... More
20 mm dia nominal bore.

650

-

-

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :

-

-

-

... More
25 mm diameter pipe

500

-

-

... More
32 mm diameter pipe

250

-

-

... More
40 mm diameter pipe

150

-

-

... More
50 mm diameter pipe

100

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (a) 15mm nominal bore

200

-

-

... More
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. (a) 15 mm nominal bore with 45 cm length.

450

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
25 mm nominal bore

60

-

-

... More
40 mm nominal bore

30

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (a) 25 mm nominal bore.

50

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

50000

-

-

... More
SUBHEAD - XIV : INTERNAL ELECTRIFICATION

-

-

-

... More
a) Point Wiring

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C.

2200

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C

4000

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.

3000

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.

5000

-

-

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire.

5500

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire.

500

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
2 x 1.5 sq. mm

3500

-

-

... More
6 x 1.5 sq. mm

1500

-

-

... More
3 x 2.5 sq. mm

4000

-

-

... More
6 x 2.5 sq. mm

6000

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

2400

-

-

... More
32 mm

2500

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

4000

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

3000

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

850

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

350

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

300

-

-

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

250

-

-

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

250

-

-

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

180

-

-

... More
Providing and laying 1.6 mm thick pregalvanized GI factory fabricated raceways of the following sizes including 2 mm thick GI covers, providing knock out holes and all required fixing accessories including 6 SWG GI earth wire complete as required including floor /wall supports, bends, access boxes and tap off boxes as per specification and cross over as per site requirement. Note:- Blue & Orange colour shall be considered for Power & Data raceway respectively. The item shall include the cost of chipping, cutting the floor for laying the raceway and making good the finish including chicken mesh complete as required as per site requirement.

-

-

-

... More
150 mm wide x 40 mm deep raceway.

900

-

-

... More
200 mm wide x 40 mm deep raceway.

550

-

-

... More
300 mm wide x 40 mm deep raceway.

350

-

-

... More
Providing and fixing of 350 x 350 x 40 mm deep (Nominal size) floor junction box including providing 2 mm thick GI cover required as per specification.

200

-

-

... More
Providing and fixing of 250 x 250 x 40 mm deep (Nominal size) floor junction box including providing 3 mm thick GI cover required as per specification.

150

-

-

... More
Providing and fixing of 150 x 150 x 40 mm deep (Nominal size) floor junction box including providing 3 mm thick GI cover required as per specification.

300

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).

-

-

-

... More
4 way (4 + 12), Double door.

6

-

-

... More
6 way (4 + 18), Double door.

8

-

-

... More
8 way (4 + 24), Double door.

20

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door.

12

-

-

... More
8 way (4 + 24), Double door.

4

-

-

... More
12 way (4 + 36), Double door.

4

-

-

... More
Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V,10 KA,`C' series, Miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole.

700

-

-

... More
Double pole.

12

-

-

... More
Triple pole and neutral.

18

-

-

... More
Supplying and fixing following rating, four /two pole 415 volts, /220 volt Residual Current Device (RCBO)/RCD having earth leakage, over load and short circuit protection at the incomer of existing Distribution Boards or in seperate enclosure, having a sensivity current of 100 mA complete with connections, testing and commissioning etc. as required :

-

-

-

... More
63A 100mA 4P RCBO.

20

-

-

... More
32A/40A 100mA 4P RCBO.

60

-

-

... More
32A/30mA DP RCBO.

12

-

-

... More
125 A 100MA RCD.

12

-

-

... More
Supplying installation, testing and commissioning of surface/recess mounting vertical/horizental type three pole and neutral,prewired, sheet steel with double door MCCB distribution board 415 volt volt LOAD BANK dust protected, duly phosphatized and powder coated ,inclusive of 200-400 amps tinned copper busbar as per incommer ratings , common netrul link, earth bar, din bar for mounting MCCB detachable gland /knock out plate, and with built in loose wire box, and superior make terminal connectiors for all incoming and outgoing circuits duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/neutral link and ready for installation including following incoming & outings as required ( L&T MAKE ) 8 Way TPN MCCB SM DB including 315 A 4P MCCB as incommer DB with 8nos-160/100/63/32Amps MCCB 25 KA Square flush mounting 0-300Amp ammeter with 3 way and OFF selector switch. 3 Nos. Cast resin current transformers of 300/5 ratio Class 1.0 for metering. Three phase indicating lamps (LED type) with MCB. Square flush mounting voltmeter 0-500 volt with 3 way and OFF selector switch.

6

-

-

... More
b) Lighting Fixtures

-

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

4190

-

-

... More
Supply of the following lighting fixtures with high efficiency translucence diffuser complete with driver having CRI 80 with THD 10% & PF 0.9 with all suspension, fixing termination, cables, accessories etc. complete in all respect as required as per site conditions.

-

-

-

... More
20 Watt Surface / Suspended / Wall Mounted LED Battern with minimum luminaire system efficiency of 100 lm/w having a color temperature of 6500K and housing should made up of extruded aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat ref. LL20-281-XXX-65-AL1

800

-

-

... More
40 Watt Surface / Suspended LED fixture with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. LE10-491-XXX-57HCSL

550

-

-

... More
12 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRDL11R017HP57

600

-

-

... More
18 Watt Surface mounted LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. LD99-281-XXX57SMWH

300

-

-

... More
18 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRDL11R023HP57

350

-

-

... More
24Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRDL11R024HP57IR

300

-

-

... More
30 Watt Recessed Server Room bottom opening Clean RoomLED 2 x 2 panel with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. LC20-411-XXX-57-XX

40

-

-

... More
36 Watt Recessed LED 2 x 2 panel with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRCO10R038HP57GL1

500

-

-

... More
10 Watt Bulkhead LED light fixture with minimum luminaire system efficacy of 70 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro cat ref. LW07-141-XXX-57-XX

250

-

-

... More
10 Watt LED Ramp light fixture with minimum luminaire system efficacy of 70 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro LW07-141-XXX-57-XX.

40

-

-

... More
LED strip with Integral driver & minimum lumen output of 400 lumens and shall have a rated system lifetime of 20,000 hours, having a color temperature of 4000K, IP 20. The Total power consumption should not exceed 14.4W (including driver) with accessories wiring etc equivalent to Wipro D45027 5050 Strip Light ( 14.4 Watt )

1500

-

-

... More
Supply of the following lighting fixtures with high efficiency translucence diffuser complete with dimmable driver having CRI 80 with THD 10% & PF 0.9 with all suspension, fixing termination, cables, accessories etc. complete in all respect as required as per site conditions.

-

-

-

... More
12 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRDL11R017HP57AN

300

-

-

... More
18 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRDL11R023HP57AN

200

-

-

... More
24Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRDL11R024HP57ANIR

60

-

-

... More
33 Watt Recessed LED 2 x 2 panel with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc equivalent to Wipro Cat. Ref. CRCO10R036HP57ANG1

100

-

-

... More
CEILING FANS Supply of the single phase heavy duty grease filled double ball bearing, aerodynamically designed heavy gauge aluminium blades, copper wounded, required length down rod, capacitor and impregnated silicon stamping motor etc.a 1400 mm sweep, brilliant white/As directed by Engineer-In-Charge (without regulator)

30

-

-

... More
Supplying and fixing two module stepped type electronic fan,regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

30

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (a) Upto 450 mm sweep.

120

-

-

... More
Supply of following sizes of Havey duty Exhaust fan with Louver suitable for operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required. (a) 450 mm Sweep (900 RPM)

120

-

-

... More
Supply of following sizes of Wall fan with suitable for operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required. (a) 600 mm Sweep.

200

-

-

... More
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type, suitable for connected load upto 10 A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

150

-

-

... More
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

100

-

-

... More
Supplying,installation,testing and commissioning of ceiling chrome and white, Opal glass. Lamp:E-14 ;LED 4Wx12 Dimension : D:870 mm H:490mm -Chandelier.

2

-

-

... More
Supplying and fixng of unifolding an intregral type flood light fixture with 50W led with powder coated die cast aluminium housing & UV-resistant high impact polycarbonate protector with inbuilt power unit -driver . The luminaire emits a pleasant, glarefree light due to the highly efficient white reflector (Asymmetrical light distribution). The complete luminaire is sealed to IP 66 & Impact resistance & LED compartment including connection with 3x1.5 sq.mm single core PVC insulated copper conductor cable form junction box to fixture as required as per Philips make BVP120 LED47 CW NB FG A1 PSU GR.

8

-

-

... More
(c) Wiring for Data / Telephone System & TV System

-

-

-

... More
Supply & fixing of one outlet of approved make and design in 1.2 mm thick GI box with grid plates with earthing complete in all respect. (a) TV antenna socket outlet.

250

-

-

... More
Supply & fixing of one no. RJ 45 jack for Data / Voice outlet of approved make and design in 1.2 mm thick GI box with grid plates with earthing complete in all respect. (a) Simplex oulet for 1 no. Data / Voice.

600

-

-

... More
Supply, installation, testing and commissioning of following  Category  6, IDC patch panel prepackaged with wiring block with legs with legs insert labels, label holders, jumper  troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs.

-

-

-

... More
24 port jack  panel

100

-

-

... More
12 port jack  panel

50

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm.

1000

-

-

... More
32 mm.

500

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 1 or 2 Module (75 mmX75 mm).

250

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

600

-

-

... More
Supply, laying, testing & commissioning of Cat-6a cable of approved make for Data/Voice system in existing conduit complete in all respect as required upto EPBAX / Data Server system.

7000

-

-

... More
(d) Earthing System

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

10

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.

10

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

500

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

300

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

250

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

600

-

-

... More
Supply, Testing & Commissioning, fixing of following bare Copper / GI tapes / wires including all necessary fixing accessories, insulators and effecting connections as per specifications.

-

-

-

... More
50 x 6 mm thick Copper Colour Code tape.

300

-

-

... More
50 x 6 mm thick GI Colour Code tape.

150

-

-

... More
32 x 6 mm thick GI Colour Code tape.

150

-

-

... More
Providing, laying, testing and commissioning of following 1100 volts grade PVC insulated sheathed copper conductor unarmoured cable including copper thimbles, fixing hardware as required.

-

-

-

... More
Single core 150 sq.mm Green colour cable.

100

-

-

... More
Single core 25 sq.mm Green colour cable.

100

-

-

... More
Single core 16 sq.mm Green colour cable.

200

-

-

... More
Single core 6 sq.mm Green colour cable.

300

-

-

... More
Supplying and making Cable end termination of following 1100 volts grade PVC insulated sheathed copper conductor unarmoured cable including copper thimbles, fixing hardware as required.

-

-

-

... More
Single core 150 sq.mm Green colour cable.

4

-

-

... More
Single core 25 sq.mm Green colour cable.

4

-

-

... More
Single core 16 sq.mm Green colour cable.

2

-

-

... More
Single core 6 sq.mm Green colour cable.

2

-

-

... More
Supply, installation, testing and commissioning of lockable terminal box in 1.6mm thick with MS enclosure with transperant cover with 1 no. (300 mm length) 50 x 6 mm copper strip on epoxy insulators with 30 no. 8mm dia holes with 8mm x 25mm dia brass nut bolt with double washer.

60

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. (a) 50 mm dia.

500

-

-

... More
(E) Lighting Protection System

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

100

-

-

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required

100

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run).

2200

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run).

300

-

-

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

80

-

-

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

2000

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.

45

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. (a) 50 mm dia.

500

-

-

... More
SUBHEAD - XV : AIR CONDITIONING SYSTEM

-

-

-

... More
EQUIPMENT VARIABLE REFRIGERANT FLOW SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow type air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating application as per the specifications and drawings. The quoted price should be include clearances charges, local taxes, freight etc. Quoted price shall also be inclusive of loading, unloading, lifting & shifting on outdoor location at site location or other suitable location as per drawing, positioning charges besides including charges towards structural steel supports, MS base frame duly painted & vibration isolation arrangement etc. Any additional required top up charge of refrigerant shall be added at site free of cost & loss of refrigeration due to deflect in equipment or workmanship shall also be filled up free of cost during execution and guarantee period. OUTDOOR UNITS- HEAT PUMPS Supply, Installation, Testing and Commissioning of Air cooled variable refrigerant flow modular type Heat Pumps, each comprising of energy efficient multiple scroll compressors, full charge of R-410a refrigerant gas and all accessories as per the specifications. All compressors shall be inverter type. The condensing units shall be suitable to work on cooling as well as heating mode. The condensing units shall be Anti Corrosive coating on Fins / Copper tubing and suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply and complete with auto check function for connection error, auto address setting and Nitrogen Testing etc. The outdoor units shall be low noise type. Quoted price shall be inclusive of MS frame duly applied with 2 coat of primer & one coat of black enamel paint with Sandwitched type Rubber Pads. The outdoor units shall be of following capacities : The machine selection based on COP Minimum 3.8 or above at full load at AHRI Condition.

-

-

-

... More
26 HP (Cooling & Heating).

5

-

-

... More
18 HP (Cooling & Heating).

8

-

-

... More
28 HP (Cooling & Heating).

2

-

-

... More
30 HP (Cooling & Heating).

9

-

-

... More
36 HP (Cooling & Heating).

4

-

-

... More
42 HP (Cooling & Heating).

1

-

-

... More
INDOOR UNITS Supply, Installation, Testing and Commissioning of variable refrigerant flow modular type indoor units equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower,multi speed motor,coil section with DX Copper coil,electronic expansion valve,outer cabinet, Grilles in ductable type unit, drain pump, necessary supports with vibration isolation & all accessories as per the specifications. The indoor units shall be suitable to work on cooling as well as heating mode. The indoor units shall be suitable for operation on 230 ±10% volts, 50Hz, 1 phase AC power supply. The unit shall have automatic force shut down provision incase of fire on receiving signal from BMS System. The IDU shall be as shown in the design drawings capacity shall be of following capacities.

-

-

-

... More
DUCTABLE TYPE

-

-

-

... More
8.0 TR / 2800 CFM.

6

-

-

... More
6.4 TR / 2400 CFM.

16

-

-

... More
4.5 TR / 1600 CFM.

1

-

-

... More
4.0 TR / 1370 CFM.

7

-

-

... More
3.2 TR / 1130 CFM.

2

-

-

... More
2.6 TR / 880 CFM.

4

-

-

... More
2.0 TR / 630 CFM.

10

-

-

... More
1.3 TR / 560 CFM

11

-

-

... More
Supply,Lifting,Shifting installation, testing and commissioning of DX TYPE Coil, MICROPROCESSOR BASED PRECISION A/C UNIT,bottom discharge complete with air cooled condenser, The unit includes scroll compressor, Electronic Expansion Valve, evaporator coil with hydrophillic coating, SS Drain Tray, EC brushless motor, plug type variable speed backward curved centrifugal blower, multistage electric heater, humidifer and vibration isolator. The cooling section should be made by a self-supporting structure of hot-dip galvanized steel; along the whole perimeter ”double skin” panels are present with internal 30 kg/m³ glass wool insulation density and 19 mm thickness.The panel should be classified as A1 according to EN13501 standard - fire reaction classes. The outer panels and the portions of the structure visible from the outside should be painted with epoxy powder colour with textured surface finish. Motor shall be suitable for 410+10% volts, 50 cycles, 3 phase AC supply .Outdoor unit motor should be with IP-54 protection and should be weather proof. PAC shall have Fan speed comtroller inbuilt in PAC unit. Auto sequencing of the unit for equal run time should be integral part of the micro-processor and also hard wired to be provided by PAC supplier. The units should be equipped with pleated air filters, with filtration class G4 according , high filtering surface and low pressure drop. The filters should be mounted inside the air handling section, on a steel frame and are disposable type (non-regenerable). The electrical panel should be positioned inside the unit, equipped with door locked by mains switch to cut power to the unit before accessing the internal components. The electrical panel shoulde include the following for all units: - Mains switch - Circuit-breakers for power and auxiliary circuits - Contactors for power loads - Microprocessor control card - Terminal strip with labelling of all cables. Unit should operate on Power supply of 415VAC/3ph/50Hz;

-

-

-

... More
Humidifer: In built Immersed Electrode Humidifier should be provided. The PAC microprocessor, the microprocessor controller should proportionally adjusts the output steam, based on the humidification level required in the room, through the regulation of the current absorbed by the electrodes. It should also control all the operating phases of humidifer: water filling and discharge, periodic emptying cycle, viewing of operating status and alarm messages. There should be an option to select whether the control needs to be based on either relative or absolute humidity. Heater: In built electrical heaters should be provided to control heating and/or post-heating. The heating elements are made of AISI304 steel and have low surface temperature, spiral AISI304 steel fins featuring a safety bimetal thermostat.Heater should be modulating type Triac-controlled electric heaters such that it can follow the condition of the room with accuracy, thus improving efficiency in heating and post-heating operation. The microprocessor control should comprise of a I/O unit to which the controlled and safety devices are connected, and an external graphic user HMI display. The graphic terminal should be a minimum 7” touch screen panel with 65000 colour display for managing high quality images and advanced functions. The touch screen panel shall be designed for easier man-machine interaction by making the screen browsing more user-friendly.

-

-

-

... More
Capacity: 11 TR / 6500 CFM.

2

-

-

... More
Capacity: 5 TR / 3000 CFM.

2

-

-

... More
Capacity: 3 TR / 1800 CFM.

2

-

-

... More
FLOOR MOUNTED AIR HANDLING UNITS WITH MIXING CHAMBER SUN EXPOSED TYPE

-

-

-

... More
Supply, Installation, Testing & Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with Thermal break profile at corners and at joints for double skin air handling units alongwith internal covings with Mixing Chamber included Fresh air damper with 0.8 mm thick precoated galvanised sheet outside & 0.8 mm thick polished finish stainless Steel sheet SS 304 inside with Backward curved direct driven plug type mettalic construction in supply with fan section with fan motor with IE3 rating & suitable for 415+10%, 3 Phase, 50 Hz along with IP 20 VFD, 6 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% combination with fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 5µ (micron) before cooling coil in supply. The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor & belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 48+/-2 mm thick injected fire retardent PUF of density 40+/-2 Kg/m³ . The motor & fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows. NOTE: 1. Magnehelic differential pressure gauge required with fine filter & same shall be included in AHU. 2. AHU, Fans & Coil should be AHRI / EUROVENT Certified. 3. Noise Level should not be exceed dB70 @ 1 Meter.

-

-

-

... More
7000 CFM / 20 TR / 6 RD / 65 mmwg St. Pressure.

2

-

-

... More
5000 CFM / 13 TR / 6 RD / 65 mmwg St. Pressure.

2

-

-

... More
FLOOR MOUNTED AIR HANDLING UNITS

-

-

-

... More
Supply, Installation, Testing & Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside & 0.8 mm thick polished finish stainless Steel sheet SS 304 inside with Backward curved direct driven plug type mettalic construction in supply with fan section with fan motor with IE3 rating & suitable for 415+10%, 3 Phase, 50 Hz along with IP 20 VFD, 6 RD DX coil suitable for refrigerant R410a with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% combination with fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 5µ (micron) before cooling coil in supply. The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor & belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 48+/-2 mm thick injected fire retardent PUF of density 40+/-2 Kg/m³ . The motor & fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows. NOTE: 1. Magnehelic differential pressure gauge required with fine filter & same shall be included in AHU. 2. AHU, Fans & Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB70 @ 1 Meter

-

-

-

... More
8500 CFM / 22 TR / 6 RD / 65 mmwg St. Pressure.

9

-

-

... More
7000 CFM / 20 TR / 6 RD / 65 mmwg St. Pressure.

2

-

-

... More
5000 CFM / 13 TR / 6 RD / 65 mmwg St. Pressure.

4

-

-

... More
REMOTE CONTROLS

-

-

-

... More
Supply, Installation, Testing and Commissioning of Nevigiator Display Type wired remote controller Corded type to control fan speed / temperature etc for the above indoor units.

19

-

-

... More
Supply, Installation, Testing and Commissioning of Cordless Type wireless remote controller to control fan speed / temperature etc for the above indoor units.

57

-

-

... More
CENTRALISED CONTROLLER

-

-

-

... More
Supply, Installation, Testing & Commissioning of Main Master Central Remote controller panel system with LCD panel suitable for above indoor units to operate, monitor, on/off, temperature setting etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of circular / rectangular inline fans for exhaust air complete with sheet metal casing, direct driven centrifugal fan, motor with proper protection and inspection door. Fan shall be suitable for operation on 220 ± 6 % volts, 50 Hz,1 phase AC power supply. Flanges to be provided on both sides to facilitate duct connections. Fan shall be installed as shown in the drawings and will be of following characteristics. All single phase inline fans shall be provided with factory fitted speed regulators. All Fans Should be complete with Plug Top & necessary power cable.

-

-

-

... More
1000 CFM / 15 mm WG St. Press. - Rectangular

12

-

-

... More
350 CFM / 15 mm WG St. Press. - Circular

2

-

-

... More
200 CFM / 15 mm WG St. Press. - Circular

2

-

-

... More
Supply, installation, testing and commissioning of Axial propeller fans manufactured from tough injection moulded polypropylene including automatin open / close louvers with motor complete motor suitable for 220 volts ± 10%, 50Hz ± 3 %, single phase A.C supply of class "F" insulation with , mountings accessories in all respect with wiring upto power supply point & of following capacities as per specification and tender drawing mentioned.

-

-

-

... More
8" Dia / 200 mm +10mm

6

-

-

... More
6" Dia / 150 mm +10mm

10

-

-

... More
LIFT WELL PRESSURIZATION & MAKE UP AIR IN EMERGENY

-

-

-

... More
Supply,installation,testing and commissining of direct driven Tube axial flow fans suitable for installing in any position in Horizontal or vertical with adjustable pitch blade, MS MS with powder double coated / High duty GSS long Casing , cast aluminium alloy impeller complete with TEFC Sq. Cage Induction type IE-3 motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 Pole, three phase A.C supply of class "F" insulation motor's winding with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep with 25 mm slack at Outlet etc.The fans shall be as per specifications & tender drawing of following capacity:- Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm.Multi piece casing is not accepted. Manufacturer shall furnish AMCA Test Certificate for air performance along with fire test certificate (Latest) for each fan sourced from that particular factory.

-

-

-

... More
11000 CFM / 25 mm Wg - For lift well pressurization.

2

-

-

... More
8500 CFM / 20 mm Wg - For lift well pressurization.

5

-

-

... More
5000 CFM / 20 mm Wg - For lift well pressurization.

2

-

-

... More
SMOKE EXTRACTION FAN FROMOCCUPIED AREA

-

-

-

... More
Supply,installation,testing and commissining of direct driven Tube axial flow fans suitable for installing in any position in Horizontal or vertical with adjustable pitch blade, MS MS with powder double coated / High duty GSS long Casing , cast aluminium alloy impeller complete with TEFC Sq. Cage Induction type IE-3 motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 Pole, three phase A.C supply of class "F" insulation motor's winding with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep with 25 mm slack at Outlet etc.The fans shall be as per specifications & tender drawing of following capacity:- Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm.Multi piece casing is not accepted. Manufacturer shall furnish AMCA Test Certificate for air performance along with fire test certificate (Latest) for each fan sourced from that particular factory.

-

-

-

... More
11000 CFM / 25 mm Wg - For lift well pressurization.

2

-

-

... More
10000 CFM / 25 mm Wg - For lift well pressurization.

2

-

-

... More
8500 CFM / 25 mm Wg - For lift well pressurization.

6

-

-

... More
7500 CFM / 25 mm Wg - For lift well pressurization.

1

-

-

... More
5000 CFM / 25 mm Wg - For lift well pressurization.

2

-

-

... More
3600 CFM / 25 mm Wg - For lift well pressurization.

2

-

-

... More
DX TYPE HI WALL SPLIT UNIT

-

-

-

... More
Supply, Installation, Testing & Commissioning of 5 star rated DX Type Hi wall split air-conditioning unit with Refrigerant R-410A consisting of condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 10 RMT(G & L). Cost includes double coat painted M.S. Stand, Gas Charging & Internal Copper Wiring & Remote Control, power wiring, stablizer alongwith each unit (set of indoor & outdoor unit) etc for below mentioned capacity. Makes: Daikin / LG / Samsung / Blue Star / Mitsubishi Electric. (a) 1.5 TR Hi-wall split.

4

-

-

... More
IAQ Device & Monitor (Sensor)

-

-

-

... More
Supply, installation, testing and commissioning of Bipolar Air Ionizer combination of Self cleaning nickel titanium based Needle point , Tube Type & Carbon Brush Type which produces a natural Bio Climate rich in equal amount of positive and negative ions. The ionizer shall be kill microorganism and pathogens, remove Odour, VOC and reduce dust particle. The Ionizer should be UL 2998 & UL 867 listed With Zero Ozone Emission. The housing material is 18G steel powder coated. Models accept 24V AC input, 120V AC to 12V DC wall pack, 120V/240V AC to 12V DC power supply and 241V/277V AC to 12V DC power supply. The cost shall be included with interlocking with IDU's fan's motor on / off. The All Cassette, Hi Wall & Ductable Units shall be Electronic Air Cleaner(EAC) Filter or Active Carbon Polarised Filter with maximum 5 mm Wg pressure drop and capbable to arrest PM 2.5 / PM1.0 particulates. For AHU

-

-

-

... More
8500 CFM

9

-

-

... More
7000 CFM

4

-

-

... More
5000 CFM

6

-

-

... More
IAQ Device & Monitor (Sensor)

-

-

-

... More
8.0 TR / 2800 CFM.

6

-

-

... More
6.4 TR / 2400 CFM

16

-

-

... More
4.5 TR / 1600 CFM

1

-

-

... More
4.0 TR / 1370 CFM

7

-

-

... More
3.2 TR / 1130 CFM

2

-

-

... More
2.6 TR / 880 CFM

4

-

-

... More
1.3 TR / 560 CFM

11

-

-

... More
2.0 TR / 630 CFM

10

-

-

... More
Supply, Installation, Testing & commissioning of IAQ Monitor to remotely measure the levels of PM 2.5, VOCs, CO2, Temperature(In / Out), Humidity on a real time basis. The IAQ Monitor shall be capable of getting connected with Wi-Fi. The Monitor should be capable of sending the indoor air quality information on display Screen/Mobile/Browser as per Client's requirement. The Monitor should indicate the quality of air through changing the colours on the display screen as per the NAAQS standards and should meet the WELL building standards. This monitor should be a 3 tier architecture including sensor Hardware, secure cloud infrastructure, monitoring apps including dashboard, android/IOS. Quoted price shall be inclusive of all necessary arrangement as required to make the unit proper functional.

2

-

-

... More
(B) PIPING WORKS.

-

-

-

... More
COPPER REFRIGERANT PIPING All refrigerant piping shall be constructed from soft seamless upto 19.1mm and hard drawn copper refrigerant pipes for above 19.1mm with copper fittings and silver soldered joints. All joints in copper piping shall be sweat joints using low temperature brazing and or silver solder. Before jointing any copper pipe or fitting, its interiors shall be thoroughly cleaned by passing a clean cloth via wire or cable through its entire length. The piping shall be continously kept clean of dirt etc. while constructing the joints. Subsequently, it shall be thoroughly blown out using nitrogen. After the refrigerant piping installation has been completed, the refrigerant piping shall be pressure tested using nitrogen at 32 Kg per sq.cm. Pressure shall be maintained in the system for 24 hours. The system shall then be evacuated to minimum vacuum if 700 mm Hg and held for 24 hours. Refrigerant should be only R-410A.

-

-

-

... More
Supply, fabrication, installation, testing of Inter connecting refrigerant pipe(whole of the suction and liquid line) including all fitting etc. with (19 mm / 13 mm thick class 'O') closed cell elastomeric nitrile rubber tubular insulation (factory laminated glass cloth 7mil thick). All piping inside the building shall be properly laid on 180 GSM GI slotted channel with steel wire rope hanger with maximum 1.8 meter span or as required(as per suit at site condition).

-

-

-

... More
41.3 mm O.D.(insulation : 19 mm)

40

-

-

... More
34.9 mm O.D.(insulation : 19 mm)

45

-

-

... More
28.6 mm O.D.(insulation : 19 mm)

90

-

-

... More
22.2 mm O.D.(insulation : 19 mm)

110

-

-

... More
19.1 mm O.D.(insulation : 19 mm)

130

-

-

... More
15.9 mm O.D.(insulation : 19 mm)

180

-

-

... More
12.7 mm O.D.(insulation : 19 mm)

270

-

-

... More
9.5 mm O.D.(insulation : 13 mm)

140

-

-

... More
6.4 mm O.D.(insulation : 13 mm)

50

-

-

... More
Supply,Installation,Testing and Commissioning of Imported Y-joints.

47

-

-

... More
(B) CONDENSATE DRAIN PIPING

-

-

-

... More
Supply & installation of rigid heavy duty uPVC piping density 10 KG/sqcm with proper slope(By gravity without any obstruction) efficeint draining of condensate water, suspended from slab with GI rod suspenders alognwith chilly clamp or recessed mounted including the cost of cutting & filling chases,repairing & making good as before or surface mounted including all fixing hardware, complete with U trap, fittings, elbows, bends and duly insulated with 6 mm thick closed cell Nitril rubber tubular / XLPE insulation as per specifications. The cost of drain pipe pipe shall be included with Brush fitting upto nearest drain trap.

-

-

-

... More
50 mm dia

30

-

-

... More
40 mm dia

150

-

-

... More
32 mm dia

130

-

-

... More
25 mm dia

50

-

-

... More
(C) DUCTING, ADP & INSULATION WORKS

-

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
24 G (0.63 mm)

2100

-

-

... More
22 G (0.80 mm)

1450

-

-

... More
20 G (1.0 mm)

400

-

-

... More
18 G (1.25 mm)

90

-

-

... More
Rectangular / Square Ducting ( Site fabrication )

-

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
24 G (0.63 mm)

50

-

-

... More
22 G (0.80 mm)

20

-

-

... More
20 G (1.0 mm)

40

-

-

... More
18 G (1.25 mm)

50

-

-

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

20

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

30

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

20

-

-

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

14

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
a) Fire damper

19

-

-

... More
b) Actuator

66

-

-

... More
Supply, Installation,Testing and Balancing of flexible ducting comprising of inner as well as outer skin constructed out of aluminium & fibre glass insulation 25mm thick of minimum 24 kg/cu.m density insulation sandwitched in between. Duct should confirm to fire rating standards BS-476 part 5, 6 & 7. Flexible Ducts of following sizes as per approved shop drawings, specifications :

-

-

-

... More
a) 100 mm Diameter

100

-

-

... More
b) 150 mm Diameter

150

-

-

... More
Duct Accoustic Lining

-

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. or anti-microbial Chemically cross linked polyethlyne foam of class"O"(XLPE)complete as required and as per specifications.

400

-

-

... More
Duct External Insulation

-

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation or anti-microbial Chemically cross linked polyethlyne foam of class"O"(XLPE) with Aluminium PE foil complete as per specifications and as required.

-

-

-

... More
a) 19 mm

3300

-

-

... More
b) 25 mm for exposed type

100

-

-

... More
Supplying & fixing of Underdeck insulation on RCC slab ceiling with approved sample of Class "O" closed cell Nitrile Rubber Insulation with 25 mm Thickness & density 40-55 Kg/Cum .Thermal Conductivity not exceeding 0.035 W/mK at an average Temperature of 0°C. Material shall have fire performance acc. to BS 476 Part 7 & Part 6, water vapour diffusion resistance ( μ factor ) shall be greater than 7000 & tested from third party for the parameteres.Insulation material shall be factory laminated with Aluminium Foil.

2500

-

-

... More
Supply, installation, testing and commissioning of Terminal HEPA Filter Module box to accomadate HEPA filter made out of 20 Gauge Aluminium Powder coated construction complete with bottom operated Damper arrangement with Al extruded damper, The housing should have 20 mm dia DOP / PAO charging port to the upstream air flow with dead plug, down stream port and air differential ports should be additionally provided along with housing. (a) 600 x 600 x 500 mm

16

-

-

... More
Supply, installation, testing and commissioning of HEPA Filter ( High efficiency particulate air) to remove particles down to 0.3 Microns ( EU-13 ) from air streams with an efficiency of 99.97 %. The filter matrix comprises glass fiber media duly sealed with epoxy and boxed in Al extruded section. (a) 557X557x150 mm - Box Type suitable

16

-

-

... More
Supply, installation Testing & commissioning of wall mount differential pressusre sensor having high accuracy of +/- 2% of measuring value(m.v.) & shall generate an output of 0-10 VDC/ 4-20 mA as output. Power supply for sensor is 24 VAC

6

-

-

... More
Supplying & fixing of 18 G thick Aluminium extruded powder coated Fresh / Exhaust air weather protected louvers with bird screen type i.e. louvers blade shall be at 45° inclination with blade pitch 40mm (with Aluminium frames if required) for ventilation. as per specification and sizes will be as per tender drawing mentioned.

20

-

-

... More
Supply, installation, testing & commissioning of Powder coated Aluminium extruded slot diffusers 2/3 way deflection for supply with Hit & mess type damper & low pressure plenum.

10

-

-

... More
Supply, installation, testing & commissioning of Powder coated Aluminium extruded slot diffusers 2/3 way deflection for supply with Hit & mess type damper & low pressure plenum.

13

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
VRF Isolator Switch Board

-

-

-

... More
Supply, installation, testing and commissioning of sheet metal weather proof enclosure with 40 A 4P RCBO(300mA). This shall include cable entry boxes both for incoming and outgoing cable) For VRV ODU units. The enclosure shall be IP 65/66

18

-

-

... More
Supply, installation, testing and commissioning of sheet metal weather proof enclosure with 32 A 4P RCBO(300mA). This shall include cable entry boxes both for incoming and outgoing cable) For VRV ODU units. The enclosure shall be IP 65/66

12

-

-

... More
Supply, installation, testing and commissioning of sheet metal weather proof enclosure with 25 A 4P RCBO(300mA). This shall include cable entry boxes both for incoming and outgoing cable) For VRV ODU units. The enclosure shall be IP 65/66

8

-

-

... More
Starter Panel for Localised AHU & Tube Axial Fans

-

-

-

... More
Design, Fabrication, Assemble, Wiring , Supply, Errection, Testing, Commissioning of Cubical wall mounted type panel made out out of 2 mm thick CRCA GI sheet, powder coated and approved as detailed below & conforming to the specifications. Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for AHU's fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. DOL starter with 25 A, 10 kA TPN MPCB, with over load relay with in built single phasing protection start /stop push buttons, analog voltmeter (96mm x 96mm), analog Ammeter (96mm x 96mm) (0-30A) with single CTs, on/off / trip indication lights with protection fuse, single phase preventer with auto / manual mode selector switch & spare auxiliary Contact.

40

-

-

... More
POWER & CONTROL CABLING

-

-

-

... More
Supplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV -PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured Copper conductor cables conforming to relevant latest amended Indian Standards with both side double compressed brass gland termination & aluminium lugs as per specification standard.

-

-

-

... More
4C x 16 Sq. mm

350

-

-

... More
4C x 10 Sq. mm

270

-

-

... More
4C x 6 Sq. mm

180

-

-

... More
3C x 4 Sq. mm

210

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4C x 16 sq.mm1.1 KV grade XLPE Insulated FRLS sheathed armoured Copper conductor cable

30

-

-

... More
4C x 10 sq.mm1.1 KV grade XLPE Insulated FRLS sheathed armoured Copper conductor cable

60

-

-

... More
4C x 6 sq.mm1.1 KV grade XLPE Insulated FRLS sheathed armoured Copper conductor cable

40

-

-

... More
3C x 4 sq.mm1.1 KV grade XLPE Insulated FRLS sheathed armoured Copper conductor cable

80

-

-

... More
CONTROL & TRANSMISSION WIRING

-

-

-

... More
Supply & Laying ,testing and commissioning of control cum transmission wiring of Copper conductor shielded cable with heavy duty PVC conduiting for looping between indoor & outdoor VRF system & to main Central remote controller system. (a) 2 C X 1.5 Sq. mm.

900

-

-

... More
Supply,laying,testing and commissioning of following copper PVC insulated, sheathed flexible cable for indoor unit/inline fans.Cabling between 6/16 amp Switch socket outlet and each of the VRF indoor units (splits/ ductables / fans etc..). (a) 3C x 2.5 Sq. mm.

120

-

-

... More
EARTHING STRIP

-

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

2200

-

-

... More
CABLE TRAYS

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width x 50 mm depth x 1.6 mm thickness.

360

-

-

... More
150 mm width x 50 mm depth x 1.6 mm thickness.

270

-

-

... More
300 mm wide x 40 mm x 2.0 mm thick

180

-

-

... More
SUBHEAD - XVI : LIFTS

-

-

-

... More
Supplying , erecting, testing and commissioning of 16 passenger (1088 kgs) machine roomless lift of speed 1.5 m/s, 7 stops, travel height upto 25.5m , with stainless steel hair line finish, Central opening doors ,microprocessor based simplex selective collective control with necessary panel board etc within Lift Well, electrically operated AC 3-phase 415Volts with VF Regenarative drive (closed Loop) all as per details attached in Technical specification

4

-

-

... More
Supplying and erecting of Goods lift of capacity 2000 kgs ,speed 0.5 m/s with stainless steel hair line finish, Central opening doors, microprocessor based simplex selective collective control with/without attendant etc complete with necessary panel board etc within lift well - Machine roomless including civil works for erections only for G+6 floors all as per details attached in Technical specification

1

-

-

... More
SUBHEAD - XVII : SECURITY & SURVEILLANCE SYSTEM

-

-

-

... More
IP CCTV SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of indoor UL Listed IP N/W colour dome camera, 1/3'' CCD / CMOS sensor, 2 MP resolution, varifocal 3-10 mm lens, Auto Iris, Day Night cameras, Vandal Proof & Motion detection, POE, ONVIF Profile S compliant complete with IP 55 Dome Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment & all accessories.

45

-

-

... More
Supply, installation, testing and commissioning of Outdoor (IP 66) UL Listed IP PTZ type colour camera,1/3'' CCD/CMOS sensor, 2 MP resolution,30x , Auto Iris, Day Night cameras, Vandal Proof & Motion detection,ONVIF compliant POE, complete with IP 55 Dome Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment & all accessories.

4

-

-

... More
Supply, installation, testing and commissioning of Layer 2 managed switch with 12 ports (RJ-45), POE as to support all cameras 15% spare ports complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, POE compliant ports, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/ LIUs/Convertors/Splicing equipment , Patch panel, Patch Cord Etc) complete as per specifications and as required.

8

-

-

... More
Supply, installation, testing and commissioning of Layer 2 managed switch with 12 ports (RJ-45). The switch shall have 8 SFP ports including SFP modules, POE compliant ports, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/ LIUs/Convertors/Splicing equipment , Patch panel, Patch Cord Etc) complete as per specifications and as required.

6

-

-

... More
Supply, Installation, Testing and Commissioning of UL listed Network Video Recorder including data base server for recording real time audio - video and data applications for 120 Cameras, of suitable Raw Capacity, capability to eliminate Single Points of Failure, redundant Power Supplies, redundant fans, .The NVR storage should store all cameras at 2 MP resolution for minimum 30 days backup @25 FPS,complete as per specifications and as required. The NVR shall be compatible with ONVIF compliant cameras. the required hardware and the software with operating system, video management client viewing license for 3 User for monitoring of all camera simultaneously complete as per specifications and as required.

1

-

-

... More
Supply, Installation, Testing and Commissioning of UL listed Network Video Recorder including data base server for recording real time audio - video and data applications for 8 Cameras, of suitable Raw Capacity, capability to eliminate Single Points of Failure, redundant Power Supplies, redundant fans, .The NVR storage should store all cameras at 1.3 MP resolution for minimum 30 days backup @25 FPS,complete as per specifications and as required. The NVR shall be compatible with ONVIF compliant cameras. the required hardware and the software with operating system, video management client viewing license for 3 User for monitoring of all camera simultaneously complete as per specifications and as required.

2

-

-

... More
Supply, installation, testing and commissioning 21" LCD Screen including all required accessories complete as per specifications and as required.

12

-

-

... More
Supply, installation, testing and commissioning of video management client workstations as required including 21" LCD, keyboard, mouse, and all required accessories complete as per specifications and as required. The licence support shall be for life time.

4

-

-

... More
Supply, laying, connecting , testing and commissioning of un-armoured 6C Single Mode Optic Fibre Communication Cable including required terminations, Junction Box, Connectors, LIU, SFP, Pigtails, Cable tie`s & Tags including MS conduit as per specification and as required.

150

-

-

... More
Supply and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required.

-

-

-

... More
20mm dia

300

-

-

... More
25mm dia

350

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed PVC conduit as required. (a) 1 run of cable.

650

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2 x 1.5 sq. mm.

650

-

-

... More
Access Control System

-

-

-

... More
Supply , installation, testing & commissioning of proximity card readers as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories(Standalone Unit).

16

-

-

... More
Supply, installation, testing and commissioning of Finger print(Biometrics) readers with keypad suitable for mounting on metal surface / metal frames or wooden frames or wall or as required based on site conditions including all accessories.(Standalone Unit).

5

-

-

... More
Supply, installation, testing and commissioning of proximity cards as per specification.

100

-

-

... More
Supply , installation, testing and commissioning of Push Button for Exit including wiring & other nessary items etc.

30

-

-

... More
Supply , installation, testing and commissioning of Two Door Controller for Controlling the above card readers with LAN onboard, TCP/IP interface as per specification mentioned including all accessories. (Tenderer to mention quantity of controllers based on their system.)

12

-

-

... More
Central access control controller complete with tamper switch, power electronics tamper switch etc. which with connect to the door controllers as stated above.

1

-

-

... More
Supply, installation, testing and commissioning of electromagnet door holder (fail safe type) of 15 lb holding force for the following doors :

-

-

-

... More
Single Leaf Door

18

-

-

... More
Double Leaf Door (Drop Bolt)

10

-

-

... More
Supply , installation, testing and commissioning of Door Contact.

12

-

-

... More
Supplying, Installation & Commissioning of Boom Barrier, 6 Meter Cover Width ;Operating Time : Normal-speed of open / close: 4 sec.,Straight boom arm with rubber bar, length: 6m, 1 No. push button ;, 2 No. Loop Detector and Ground indicution coil. IP 54 .Barrier arm is Aluminum Alloy Octagonal ArmHousing color: Yellow)/orange/white/red/blue

1

-

-

... More
Supply, installation, testing and commissioning of door open break glass switch for individual access control door. This shall be located in a powder coated lockable enclosure housed in control room. Quoted price shall be inclusive of wires in 25 mm dia MS conduit between door and this switch.

10

-

-

... More
Supply, installation, testing and commissioning of master switch for opening all access control door. Quoted price shall be inclusive of wire in 25 mm dia MS/GI conduit between doors and switch.

2

-

-

... More
Supply , installation, testing and commissioning of software for access control

1

-

-

... More
Supply , laying , testing and commissioning of the following cables including 25mm MS conduits with all accessories. (a) 8 Conductor, 18-24 AWG, with sheild.

2000

-

-

... More
Supplying, Installation & Commissioning of X ray Baggage scanner big computer based multi energy X-Ray baggage inspection system capable of passing through bags/parcels of dimension 940 mm (W) x 640 mm (H) with Belt Height -750 mm -850 mm with 22"/24" LCD Monitor, Input/Output rollers with frames etc as required.

1

-

-

... More
Supplying, Installation & Commissioning of GARRETT PD6500i 33 zone Weatherproof / Waterproof Door Frame Metal Detector (DFMD) with 220V AC mains compatible. (Model: 1168424 - Grey Color). Detailed Technical Specifications.

1

-

-

... More
Supplying, Installation & Commissioning of GARRETT Super Scanner V HHMD with 9 V Alkaline Battery with audio alarm & visual alarm and vibration alarm. Model : 1165190 with Rechargeable Battery Kit - Allows recharging without the need to remove the battery. Includes environmentally friendly Cadmium free Ni-MH battery and charger for 220 V AC supply. Detailed Technical Specifications.

2

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm

2500

-

-

... More
Supply and fixing of following sizes of MS conduit alongwith the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required.

-

-

-

... More
25mm dia.

2500

-

-

... More
32mm dia.

1000

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (a) 1 run of cable.

600

-

-

... More
SUBHEAD - XVIII : FIRE FIGHTING SYSTEM / FIRE ALARM SYSTEM

-

-

-

... More
Fire Fighting System

-

-

-

... More
Supplying, installing, testing & commissioning of electric driven Main Fire Pump suitable for automatic operation consisting of the following: complete in all respect as required. (a) Horizontal split casing multistage centrifugal suction type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal to ensure a minimum pressure 3.5 kg/cm2 at highest and farthest outlet at specified flow of 2850 lpm against a total head of 85 metres conforming to IS: 1520. (b) Squirrel cage induction motor suitable for 415 V, ± 10%, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 1500 RPM T.E.F.C. type such as confirming to IP:55 protection for inclosure, horizontal foot mounted type wth Class-'F' insullation, conforming to IS: 325. (c) Mild steel fabricated Common base plate of channel, coupling, coupling guard, foundation bolts ect. as required. (d) Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers with anti vibration pads as required.

1

-

-

... More
Supplying, installing, testing & commissioning of Diesel Engine driven main fire Pump suitable for automatic operation consisting of the following (as per specification). (a) Horizontal split casing multistage centrifugal suction type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal to ensure a minimum pressure 3.5 kg/cm2 at highest and farthest outlet at specified flow of 2850 lpm against a total head of 85 metres conforming to IS: 1520. (b) Suitable HP, 1500 RPM water cooled with radiator, Diesel Engine conforming to relevent BS & IS standard complete with auto starting mechanisum, 12 volts/24 Volts electric starting equipment i/e suitable maintenance free batteries of 12 V, 180 AH. Diesel tank 990 lts. with first charge and manual oil pump set., Exhaust pipe extended upto open top of building as per requirement duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer , instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour ect. as required, common bed plate for mounting of engine. (c) Mild steel fabricated Common base plate of channel, coupling, coupling guard, foundation bolts ect. as required. (d) Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers with anti vibration pads as required.

1

-

-

... More
Providing & fixing, testing and commissioning of electrical driven pressurisation pump (jockey pump) suitable for automatic operation and comprising of following: complete in all respect as required. (a) Horizontally mounted centrifugal end suction type Jockey pump complete of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal delivery of 180 lpm against a total head of 85 metres complete with arrangement for testing of the working of the pumping set as requiredconforming to IS: 1520. Rate shall also include Mechanical Seal. (b) Squirrel cage induction motor T.E.F.C type suitable operation on 415 V ± 10%, 3 phase 50 Hz AC supply wit IP 55 class of protection for encloser, horizontal foot mounted type class - 'F' insulation, confirming to IS : 325 of suitable rating for the above pump with synchronous speed of 2900 RPM. (c) Mild steel fabricated Common base plate of channel, coupling, coupling guard, foundation bolts ect. as required. (d) Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers with anti vibration pads as required.

1

-

-

... More
Supplying, installing, testing & commissioning of electric driven Fire Pump (Water curtain) suitable for automatic operation consisting of the following: complete in all respect as required. (a) Horizontal split casing multistage centrifugal suction type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal to ensure a minimum pressure 1.4 kg/cm2 at farthest outlet at specified flow of 900 lpm against a total head of 45 metres conforming to IS: 1520. (b) Squirrel cage induction motor suitable for 415 V, ± 10%, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 1500 RPM T.E.F.C. type such as confirming to IP:55 protection for inclosure, horizontal foot mounted type wth Class-'F' insullation, conforming to IS: 325. (c) Mild steel fabricated Common base plate of channel, coupling, coupling guard, foundation bolts ect. as required. (d) Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers with anti vibration pads as required.

1

-

-

... More
ELECTRICAL PANEL

-

-

-

... More
Supply, Installation, Testing & Commissioning of electrical control panel of cubical construction, floor mounted, fabricated out of 2mm thick CRCA sheet, totally enclosed with channel base frame, compartmentalised extensible segregated hinged lockeble door, dust and vermin proof, powder coated of approved shade after 7 tank tratment process, cable alley, inter-connection, having switchgears and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with extensible busbars on both sides, making interlocking arrangement between incomers & buscoupler breakers, including control wiring with 2.5 sq mm size wires/cable, metering instruments and accessories as per specifications with enclosure protection class IP 42 as required. INCOMER (a) 2 No. 630 Amp four pole Moulded Case Circuit Breaker (Ics value 50 KA) with built in microprocessor based release unit with adjustable setting. INSTRUMENTS (a) 2 No. digital multifunction meter (Ammeter + Voltmeter) for 3 phase, 4 wire operation as per specification. (b) 2 Sets of RYB phase indicating lamp scontrolled by 2 amp MCB & with toggle switch. (c) 1 Sets of Buscoupler breaker 'ON', 'OFF' lamps controlled by 2 amp MCB. BUSBARS (a) 800Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. BUSCOUPLER (a) 1 No. 630 Amp four pole moulded case circuit breaker (Ics value 50KA). Including all features of electrical & mechnical interlocking

-

-

-

... More
OUTGOING (a) Main Fire Pump (Hydrant and Sprinkler Pump) (2 set) each feed shall contain the following :- 1 Nos. 250 amps TP MPCB (Ics value 50 KA) with inbuilt thermal magnetic release with all acessories incluidind 1 No. Auto DOL stater suitable for 90 HP with, simplw phase preventor oil relay ammeter with CTs `ON'/OFF`TRIP' indicating lamp and push bottons, potential free contacts for remote operation in each feeder and auto / mannual selector switch complete as required. (b) Jockey Pump (Hydrant and Sprinkler Pump) (2 set) each feed shall contain the following :- 1 Nos. 63 amps TP MCCB (Ics value 35 KA) with inbuilt thermal magnetic release with all acessories incluidind 1 No. Auto DOL stater at 10 HP with, ammeter with CTs `ON'/OFF`TRIP' indicating lamp and push bottons, potential free contacts for remote operation in each feeder and auto / mannual selector switch complete out going feeders to pump motor. (c) Water Curtain Pump (1 set) 1 Nos. 160 amps TP MPCB (Ics value 50 KA) with inbuilt thermal magnetic release with all acessories incluidind 1 No. Auto DOL stater suitable for 40 HP with, simplw phase preventor oil relay ammeter with CTs `ON'/OFF`TRIP' indicating lamp and push bottons, potential free contacts for remote operation in each feeder and auto / mannual selector switch complete as required. (d) Diesel Engine Control: Control for Diesel Engine comprising:- (I) Auto/ Manual selecator switch & 3 attempt strating device, timers and relays as required, push buttons, strat/stop in manual mode.

-

-

-

... More
(ii) Indication lamp for High/ Low Lub. Oil pressure, High Water Temp. and Engine ON Indication. (iii) Battery chrager suitable for 12 V/ 24 V DC with boost and tickle selector switch, 0-30 V DC volt meter, 0-20A DC Ammeter. (iv) All standard senescing and protection relays and accessories for automatic operation of diesel engine. System Controller Designing, Supply, Installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurisation pump in sequence as per specification consisting of relays, timers, sensors, annunciation window for fault indication, complete as per specification. Note: All breakers shall be mechanical interlocked with suitable accessories. Separate neutral link shall be provided in all 3 Pole feeders. Spare Feeder & 4 No. MPCB. All breakers breaking capacities shall be ICU=ICS

1

-

-

... More
Indication Panel in Fire Control Room Supply, installation, testing & commissioning of wall mounted remote indication panel for fire fighting system fabricated from not less than 1.6 mm. thick CRCA sheet, powder coated of approved shade, complete internal wiring, indicating lamps, relays, accessories, numbering, lettering complete in all respect and consisting of the following as required. (a) ON/OFF indication of main electrical fire pump and Sprinkler pump, pressurisation pump. (b) Audio/Visual indication of operation of main electric/diesel fire pump with reset push button. (c) Pressure indication in fire fighting system (pressure transducer to be installed under separate item.) (d) Failure of Hydrant / Sprinkler pump to start. (e) High level in fire water storage tank compartment. (f) Low level in fire water storage tank compartment. (g) Low level in HSD day tank of the fire pump.

1

-

-

... More
Supplying and laying of 1.1 kv grade XLPE insulated PVC sheathed armoured aluminium conductor cable of following size on existing cable tray suitably clamped and as required conforming to IS : 7098

-

-

-

... More
3 core 150 sq. mm.

50

-

-

... More
3 core 25 sq. mm.

50

-

-

... More
3 core 16 sq. mm.

50

-

-

... More
Supply and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable of 1.1 KV grade between various sensors and controller etc. in pump house on existing cable tray complete with connections at both end with glands etc. as required. (a) 4 x 2.5 sq. mm.

300

-

-

... More
Supply and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE Aluminium conductor cables of 1.1 KV grade as required.

-

-

-

... More
3 core 150 sq. mm.

6

-

-

... More
3 core 25 sq. mm.

4

-

-

... More
3 core 16 sq. mm.

4

-

-

... More
Supplying and installing following size of perforated painted with powder coating MS Cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc as required. (a) 150 mm width X 50 mm depth X 1.6 mm thickness.

80

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip from earth electrode to equipment as required.

150

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

60

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

120

-

-

... More
Providing, fixing, testing and commissioning of precharged air vessel (size 250 mm dia & 1500 mm height of 8.0 mm thick MS sheet) for pressurization of hydrant / sprinkler system complete with pressure gauges, one no 25 mm dia drain valve, air release valve on top and flanged connection to riser with stop cock on the top, 50 mm dia inlet with isolating valve duly painted with syntheic enamel paint of approved shade from inside and outside complete as required.

1

-

-

... More
Supplying, testing, installation & commissioning of pressure switches for Pumps, including necessary wiring upto control panel & all required materials to complete.

6

-

-

... More
Providing & fixing dial type (150 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows, stainless steel 'U' tube & ball valve etc as required.

6

-

-

... More
Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows, stainless steel 'U' tube & ball valve etc as required.

60

-

-

... More
Providing & fixing electronic type water level indicator with LED panel mounted as required by the Engineer-Incharge complete with probes & all control wiring etc.

1

-

-

... More
Providing, laying, jointing, testing and commissioning of 'C' Class Heavy duty G.I. Pipe following sizes conforming to IS: 1239 / 3589 with all accessories like all fittings (treaded / grooved fitting joint shall be used on the pipes) including tees, elbows, headers, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor / wall /ceiling with galvanised clamps,hangers (using anchor fastners) as per specification. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Engineer-Incharge requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwire and then supply of the same shall also be included for rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted. Providing two coats of synthetic enamel paint of approved shade over a coat of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per direction of Engineer-Incharge. Note :- Upto 40 mm dia. pipe threaded fittings and threaded joints shall be provided (jointed by Teflon tape) and for 50 mm dia & above pipes Grooved joints shall be used. The Ductile iron fittings or Malleable Iron (IS : 1879) fittings shalll be heavy duty suitable to withstand at least a pressure of 150% of maximum working pressure with minimum of 15 kg/cm2.

-

-

-

... More
25 mm dia.

1800

-

-

... More
32 mm dia

500

-

-

... More
40 mm dia

1000

-

-

... More
50 mm dia

900

-

-

... More
65 mm dia

600

-

-

... More
80 mm dia

600

-

-

... More
100 mm dia

500

-

-

... More
150 mm dia

500

-

-

... More
200 mm dia (IS : 3589) (wall thickness 6 mm)

150

-

-

... More
250 mm dia (IS : 3589) (wall thickness 6 mm)

12

-

-

... More
300 mm dia (IS : 3589) (wall thickness 6 mm)

10

-

-

... More
Excavating trenches by mechanical / manual means of required width for Pipes, cables etc. including excavation for sockets and dressing of sides ramming of bottoms for all depths including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil (a) Pipes cables etc exceeding 80mm dia but not exceeding 300mm dia.

150

-

-

... More
Providing, laying, jointing and testing in trenches the following sizes of 'C' Class Heavy duty G.I. Pipe conforming to IS: 1239 with accessories like fittings (grooved) including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. Pipes shall be embedded all around 150mm thick compacted silver sand and providing protection to embedded G.I pipes and fittings and providing anticorrosive treatment with coaltar / asphalt tape as per IS: 10221 & Specification. The rates will include providing and laying 4 mm thick "Pypkote" tar based polymeric corrosion protection tape over coat of zinc chromate primer as per manufacturers specs, as directed and as per IS:10221.

-

-

-

... More
80 mm dia

20

-

-

... More
100 mm dia

40

-

-

... More
150 mm dia

100

-

-

... More
Providing laying, testing & commissioning of 'B' class medium duty GI pipe conforming to IS 1239 incluiding fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etcfixing the pipe on wall/ celling with suitable clamps and painting with two or more coat of synthetic enamel paint of required shade as required for Sprinkler Drain. (a) 80 mm dia.

150

-

-

... More
Supplying, fixing, testing & commissioning gun metal single headed fire hydrant landing valve with flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. CI wheel, GM coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. (type A) Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required.

100

-

-

... More
Supply & fixing in position ISI marked Ductile iron grooved end type butterfly valves (FM approved), as per IS:13095, (PN 16), with ductile iron disc, shaft, including testing and complete with all required acessories with weatherproof actuator and pre-wired supervisory switches.

-

-

-

... More
50mm dia

1

-

-

... More
65mm dia

1

-

-

... More
80mm dia

50

-

-

... More
100mm dia

10

-

-

... More
150 mm dia

15

-

-

... More
200 mm dia (Gear Operated)

1

-

-

... More
250 mm dia (Gear Operated)

1

-

-

... More
Supply, erection, testing and commissioning of Ductile Iron Sluice Valve (FM approved) dimensions as per IS:14846-2000, Class PN-16, EPDM coated cast iron disc with handwheel, brass sluice valves complete with flanges, bolts, nuts and rubber insertions complete with all fittings and acessories as required of following sizes.

-

-

-

... More
50mm dia

6

-

-

... More
100mm dia

1

-

-

... More
150mm dia

5

-

-

... More
200mm dia

2

-

-

... More
250 mm dia

2

-

-

... More
Supply & fixing in position Ductile iron body grooved end type check valve (NRV) (FM approved) (PN 16), with SS plates, hinges, pins, springs, brass / SS shaft, nitrile rubber lining, complete with all acessories as required with testing as per direction of the Engineer - in - charge.to IS: 5312.

-

-

-

... More
50mm dia

1

-

-

... More
100mm dia

2

-

-

... More
150mm dia

6

-

-

... More
250 mm dia

1

-

-

... More
Providing, fixing, testing & commissioning of Ductile Iron grooved end type `Y' strainer with SS 304 perforated metal removable basket including all fittings complete as required and suitable for system pressure. (a) 250 mm dia

2

-

-

... More
Supply, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 oC temperature, working pressure 15 Kg/cm2 and test pressure 20 Kg/cm2 for :-

-

-

-

... More
50 NB

2

-

-

... More
100 NB

1

-

-

... More
150 NB

4

-

-

... More
200 NB

3

-

-

... More
Providing & fixing non-percolating rubber reinforced lined (RRL) fire hose pipe (as per IS : 636) Type-A of 63 mm dia and 15 meter length. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked brass male & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire .

60

-

-

... More
Providing gun metal ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes with 15 mm dia. Nozzle as per IS : 903, suitable for hydrostatic test pressure 21 kg/sqcm and suitable for interconnections to hose pipe coupling as required.

100

-

-

... More
Supplying and fixing First- Aid Hose Reel full swinging type with MS construction spray painted conform to IS 884. with following as required. (a) 30 m length x 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced ) type-2 ase per IS: 12585. (b) 20 mm (nominal internal) dia gun metal globe valve & nozzel. (c) Drum and brackets for fixing the equipments on wall. (d) Connection from riser to hose reel 40 mm ball valve & M.S. pipe including sockets, nipples, elbows etc.

18

-

-

... More
Supplying and fixing weather proof lockable cabinet of size not less than 0.9 x 0.6 x 0.6 mtr made out of 2mm 16 SWG MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 nos. 15mtr long hose pipe, 1 No. branch pipe, mounted on wall or raised brick platform & dully painted with Post office red extarnally and white internally with synthetic enamel paint suitably marked on the outside with the letters "FIRE HOSE", complete in all respect, for external hydrant and terrace as required.

12

-

-

... More
Providing and fixing standard fire hose cabinet single door with frame (1200 mm x 2100 mm ) or (suitable to fit in the duct made of not less than 16 SWG 2mm thick MS sheet having glass hinged door (6 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words "FIRE HOSE" to be painted on the box.

12

-

-

... More
Supply & installation of cast iron body 4 way 63 mm dia male instantaneous inlet coupling complete with inbuilt NRV, cap and chain for fire brigade connection conforming to IS : 904 and making connection with fire fighting pipe or under ground water tank, completing the work in all respect as per the directions of the Engineer-in-charge.

2

-

-

... More
Providing & fixing MS cabinet (to enclose above FB connection) fabricated from 2 mm MS 304 sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx 0.6m x 0.6m x 0.45m)

2

-

-

... More
Providing & fixing gun-metal fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS: 902-1974 complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (4 Nos) (GI pipe to be paid separately through appropriate item while cost of foot valve to be included).

2

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone -III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : (a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg( weight of cover 23 kg and weight of frame 15 kg). With Sewer bricks conforming to IS : 4885

2

-

-

... More
Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885

2

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS 1786 having minimum cross section as 23 mm x 25 mm and overall minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) complete as per design.

10

-

-

... More
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS: 4736-1968.

6

-

-

... More
Providing & fixing 25mm dia air release valve with forged brass body full way ball valve type isolating valve, flanges / union, suitable for sprinkler / wet riser / down comer system with all necessary connections complete in all respects.

6

-

-

... More
Supply, fixing, testing & commissioning of FM approved Installation Control Valve with Grooved Ends with Black enamel coated ductile iron body conforming to ASTM A-536, grade 65-45-12, aluminum bronze clapper, stainless steel spring and shaft, EPDM seal, and Nitrile seat O-rings. Valve internal parts shall be replaceable without removing the valve from the installed position. Water working pressure is 300 psi. Suitable for constant and variable pressure systems with optional retard chamber & as per manufacturer's specifications complete as required. (a) 150 mm diameter.

2

-

-

... More
Supply, fixing, testing & commisioning of C.P. bronze / gun metal quick response type Sprinklers, comprises of 15mm dia, glass bulb type, UL / FM listed / approved. The jointing shall be done by teflon tape and the installation shall be complete as per the drawings with positioning of sprinklers as per final coordinated plan and requirement of IS : 15105, local fire service & Engineer-in-charge.

-

-

-

... More
Pendent Sprinkler 68 degree C.

600

-

-

... More
Side wall Sprinkler 68 degree C.

80

-

-

... More
Upright Sprinkler 68 degree C.

900

-

-

... More
Pendent Sprinkler 79 degree C.

10

-

-

... More
Note :- (i) All sprinkler shall be chrome finish / powder coated except for the concealed ones. The concealed sprinkler shall be of brass finish. The cover plates of the concealed sprinkler shall be factory painted at manufacturer’s work and the shade shall be confirmed prior to application on the cover plate. (ii) The sprinkler shall be either pendent OR upright type and shall not be universal style / nature. (iii) Contractor shall ensure provision of sprinkler guard at no additional cost, as required by the Project Manager.

-

-

-

... More
Supply, fixing, testing & commissioning of Braided FM & VDS approved Annular Corrugation Stainless Steel flexible sprinkler pipe drop pressure rated upto 200 psi. The drop shall consist of a BRAIDED type 304 stainless steel flexible tube, zinc plated steel Male threaded nipple for connection to branch-line piping, and a zinc plated steel reducer with a female thread for connection to the sprinkler head and with a numbering on the reducer to ease the process for vertical positioning of the sprinklers with Bracket arrangement as per the Ceiling Profile. The bracket assembly shall be one piece open gate bracket complete in all respect.

-

-

-

... More
1000mm

500

-

-

... More
1200mm

250

-

-

... More
1500mm

10

-

-

... More
Providing, fixing, testing & commissioning of Ductile iron grooved end type Zone Control Riser Module with FM Approval complete with necessary fittings – Shut Off & Test & Drain Valve, Waterflow Detector complete with all acessories as required.

-

-

-

... More
100mm dia

5

-

-

... More
150mm dia

10

-

-

... More
Supply, fixing, testing & commisioning of UL / FM listed / approved 15 mm NB water curtain nozzle chrome plated complete including fixing in position on pipe complete in all respects with Teflon tape.

80

-

-

... More
Providing and Fixing of UL/FM Approved Deluge Valve with Grooved Ends low differential, latched clapper design, black enamel coated ductile iron body conforming to ASTM A-536, grade 65-45-12, aluminum bronze clapper, stainless steel spring and shaft, peroxide cured EPDM diaphragm, EPDM seal, brass seat, and Nitrile seat O-rings. & S.S Shaft complete with Electrical release trim, Hydraulic Release trim, Pressure Switch, Solenoid valve actuator and Control Panel, control wiring including necessary accessories, complete with tap off socket arrangement as required, with potential free contact with 2 Nos. NO/NC & ON/OFF arrangement and all other associated works of complete as required. Note: Cable for Integration of deluge valve / Drencher system with Fire Alarm System shall be included. (a) 100 mm diameter

2

-

-

... More
Supply & fixing pressure reducing station consisting of forged brass pressure reducing valve, butterfly valve at both end and bypass arrangement, with pressure guage at inlet and outlet (PN 16) with SS seal, metallic brass diaphram system suitable for controlling outlet pressure of water having inlet range of maximum 12 kg/cm2 and outlet range of 2-6 kg/cm2, complete with screwed ends as required.

-

-

-

... More
150 NB Pressure reducing valve

1

-

-

... More
150NB Butterfly Valves

2

-

-

... More
Supply, installation, testing and commissioning ISI marked (IS:940) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.

30

-

-

... More
Supply, installation, testing and commissioning ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and walll suspension braket.

30

-

-

... More
Supply, installation, testing and commissioning of clean agent type Fire Extinguisher ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve complete in all respects including wall suspension bracket and conforming to IS:15683. (a) 2 Kg

30

-

-

... More
Supply, installation, testing and commissioning Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and conforming to IS:910. (a) 50 Litres (trolley mounted)

2

-

-

... More
Gas Flooding system for LT panel (a) Extinguishing Agent : 2 Kg Clean Agent NOVEC1230(UL/FM with Zero Ozone Depletion Potential , EPA & SNAP Approved Can : Stored Pressure Type, Deep drawn and Argon welded , M.S, Sheet metal thickness 1.5 mm, 100% Hydraulic Pressure tested, conform to EN/PED standarda. Can shall be manufactured as per IS:15683 and complete tests of the body as per IS 15683, shall be demonstrated.(Vibration, tapping,drop test, cylic pressure test, temperature range test) Burst pressure shall be greater than 55bars. CE Marked (9 no.) (b) Tube for automatic fire detection and suppression system made by special modified Polyamide (PA), Color Red RAL300, High grade quality, Inner diameter 4mm, OuterDiameter 6 MM, Pressurised with dry Nitrogen at 13.5/10.5 bar pressure UL approved as per UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMS (345 RM). (c ) 18 no. T Connection, Brass, Nickle plated, for 4x6 mm Sensor Tube, quick and easydisassembly using special tool, External Diameter tube 6mm. (d) 18 no. End of Line Plug for Automatic fire suppression tube used for fitting at the tube end to terminate the point. Fitting made by brass nickel plated material . (e) 9 no. End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check Valve, Pressure Gauge and fitting to connect to sensor tubing. Tube connection 6mm. (f) 9 no. Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars. (g) 1 no MASTER CONTROL UNIT

1

-

-

... More
(B) Fire Alarm System

-

-

-

... More
Supply, installation, testing and commissioning of the Microprocessor based intelligent analogue addressable, modular, expandable networkable, 20 loop (each loop shall consist of minimum 100 detector & 100devices and 10% spare loop capacity) fire alarm control panel with minimum 128 character LCD display, multiple access levels, event history file in non-volatile memory (EEPROM). The panel shall have a built-in integrated voice command center with suitable rating amplifiers for minimum 25 speaker zones. The panel shall support programmable relay for controlling fans/AC equipment and monitoring of fire sprinkler etc controlled by powerful Boolean logic equation. The panel shall have minimum five independent hazard release circuit built-in the panel. The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 4 hours during emergency condition. The panel shall be UL/EN listed. Note: Provision for additional loops for Future floors shall be included

1

-

-

... More
Supply, installation, testing and commissioning of the Repeater panel with 64 character back lit LCD display with complete system function keys for programming and control like system reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc. as per specification. Quoted price shall be inclusive of wire in conduit between main panel and repeater panels. (at Guard Room).

1

-

-

... More
Supply, installation, testing and commissioning of the Analog addresable Photoelectric smoke detector with mounting based LED, address switch to programme the detectors complete as required.

600

-

-

... More
Supply, installation, testing and commissioning of the Analog addressable rate of rise cum fixed temperature detector with mounting based LED, address switch to programme the detectors complete as required.

250

-

-

... More
Supply, installation, testing and commissioning of the Fault Isolators for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement complete as required.

60

-

-

... More
Supply, installation, testing and commissioning of the Addressable control relay modules complete as required as per specifications.

60

-

-

... More
Supply, installation, testing and commissioning of the Addressable Monitor modules complete as required as per specifications.

50

-

-

... More
Supply, installation, testing and commissioning of the Addressable Manual Call Points complete as required as per specifications.

36

-

-

... More
Supply, installation, testing and commissioning of the Fire Alarm Hooter and Strobe suitable for recessed/surface mounted including addressing module complete in all respect as required

24

-

-

... More
Supply, installation, testing and commissioning of the Fire fighter's Telephone Jack suitable for recessed/surface mounted including addressing module complete in all respect as required.

24

-

-

... More
Supply, installation, testing and commissioning of the Fire Alarm multi tap Speaker suitable for Ceiling / wall mounted including addressing module having an audible range of 25 meters complete in all respect as required.

200

-

-

... More
Supply and fixing of following sizes of steel conduit along with the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required.

-

-

-

... More
20mm dia.

1000

-

-

... More
25mm dia.

2000

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2 x 1.5 sq. mm

3000

-

-

... More
SUBHEAD - XIX : WATER COOLER

-

-

-

... More
Supplying, erection, testing and commissioning of Water cooler of capacity 80 LPH (50-80) of approved make including all accessories for fixing as per direction of engineer in charge.Cooling capacity :50 lph, Tank Storage : 80 ltrs , No. of Faucet: 2 no( Cold & Normal) .

16

-

-

... More
SUBHEAD - XX : POWER BACKUP / UPS SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of 4 x 200 kVA UPS in parallel redundant N+1 configuration, 3 phase (415 V + 15%) Volts input & 3 phase output (415 V + 1%), 50 Hz, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 15 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quoted price shall be inclusive of approved rating single core copper conductor cable connecting UPS and batteries. (for workstations, Servers, LV System & emergency lighting)

1

-

-

... More
SUBHEAD - XXI : AUDIO VIDEO SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of Projection System with LCD Technology with native resolution of 1280 x 800 , 4000 ANSI lumens , 16:10 aspect ratio. Contrast 2000:1 and above. Projector Should be supplied with Ceiling Mount Kit- Acceptable .

1

-

-

... More
Supply, installation, testing and commissioning of Projection System with 1 CHIP DLP Technology, laser diaode with native resolution of 1920 x 1200 , 5000 ANSI lumens , 16:10 aspect ratio HD, 1.8x manual zoom (throw ratio 1.22-2.26:1), manual focus F 1.6-2.2, f 17.1-31.7 mm, H/V Lens Shift and 2x Zoom Lens, 360 degree flexible angle setting, lamp life 20000 hrs. HD base-T, Multiscreen Suppot. Projector Should be supplied with Ceiling Mount Kit.

1

-

-

... More
Supply, installation, testing and commissioning of 120" Diagonal Motorized Projector Screen with Tensioned

1

-

-

... More
Supply, installation, testing and commissioning of 150" Diagonal Motorized Projector Screen with Tensioned

3

-

-

... More
Supply, installation, testing and commissioning of 55 " Flat Panel Professional Display with speaker and Brightness 350 nits (cd/m2) typical , Contrast ​1200:1 full field, Resolution ​1920 x 1080 (16:9) . With Wall mounting kit. as per technical specification.

50

-

-

... More
Supply, Installation,Testing & Commissioning of Cable Cubby (1 HDMI,1 VGA , 1 Power, 1 lan).

50

-

-

... More
Supply Installation Testing & Commissioning of 5"+1.5" Coaxial Ceiling speaker with ABS cover, 30W, 100V, cutout 185mm, ABS baffle & back cover, metal grille. The Speaker shall have following Feature: Max SPL 102 dB, Frequency Response 90-20kHZ. The Speaker shall have Multiple tapping.

4

-

-

... More
Supply, Installation,Testing & Commissioning of handheld Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-20,000 Hz, Dynamic Range 100dB, THD 0.5%, S/N ratio 105dB, Carrier frequency range 200 - 270 MHz, Power Consumption 85mA.

1

-

-

... More
Supply Installation Testing & Commissioning of Intellectual Digital Podium Broadcasting system with LCD display, U socket and Mic/Line Inputs. Frequency Response 100Hz~16, 000Hz, S/N Ratio 45dB .

2

-

-

... More
Wall Plate/Floor Box for microphone connectivity with 2 x XLR

2

-

-

... More
Supply Installation testing and comisioning of 500W RMS Dual Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving, Separate PFC Design for highest reliability, Separate Power Supply System. Amplifier shall have Following Features: 500W RMS per Channel, Amplifier Output 100V, Supply input AC 220 +/- 10% - 50/60Hz, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD 0.1%, Frequency Response 40Hz - 20kHz, AC & DC Fuse, SNR 80dB

2

-

-

... More
Supply Installation Testing & Commissioning of 8-channel Phantom Power Microphone/Line input, 8-channel circuit Output; Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD 0.003%, Channel Seperation 92dB,Seperate Mute Control each channel,CMRR80dB, 12 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC,High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable.Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing

2

-

-

... More
Supply, installation, testing and commissioning of HD Video Conference System Terminal, support 4 users without MCU, ideal for small video conference system with Software for PC, mobile, laptop, support Windows, IOS/Android, in English.4 micro control unit so that it supports 4 party conference and intelligent split screen; Wide adaptation and interworking; Support HD 1080P video and OPUS 48K Hi- audio; U with the feature of anti network volatility; H.264 high prole; Dual-stream, dual-display, and the video format is 1080P; Reliability: Easy to use: boot conguration is same with the last conference; 2 hot-key: 1 is to attend the meeting, and the other is to speak; no need professionals; HD: Support 1080P/60. COMMUNICATION PROTOCOL: Multimedia framework protocol: ITU-T H.323 and IETF SIP. Support H.264 (High prole); With HD video input/output: DVI and HDMI; Video resolution: 1080P60/50, 1080P30/25, 1080P24,720P, D1, 480P CIF QCIF; Static Graphic: 1080P(1 to 60 fps), 1280x1024, HD 720P, XGA, 640x480; Support dual-stream technique H.239; main/auxiliary stream is up to 1080P/60; Low bandwidth HD image 1080P/30; Min. Bandwidth is 1Mbps;

2

-

-

... More
Supply, installation, testing and commissioning of HD Video Conference System Camera, 18-20 optical zoom as per technical specification. Low Noise High SNR: SNR from the camera directly aects the compression coding eciency of HD video conference image Wide range, high speed, low noise pan/tilt operation: the new stepper motor driver, very quiet and smooth running, enable to move quickly to a designated location , and a wide range of shooting Full HD multi-format video output: support 1080P60, 1080P50, 1080P30, 1080P25, 720P60, 720P50, 720P30 multiple HD video formats, simultaneously output multiple analog and digital HD video signal in the DVI-I, HDMI, HD-SDI interfaces at the same time High-quality image transmission through HD multimedia interface: providing DVI-I digital HD multimedia interface, compatible with both analog and digital HD video outputs, can be connected to HD display devices by cable directly

2

-

-

... More
Supply, installation, testing and commissioning of HD Video Conference System Omnidirection Microphone as per technical specification. Full duplex echo cancelling depth: 65dB; Full duplex echo cancelling time: 500 ms; Dual Noise Compression: 18dB; Line echo cancelling depth: 25dB; Line echo cancelling time: 32 ms.Microphone frequency response: 100Hz-20KHz Microphone pickup range: 5 m Microphone pickup angle: 360 degree,Microphone QTY: 4 pcs , Speaker frequency response: 100Hz-20KHz

2

-

-

... More
Supply, Installation,Testing & Commissioning of Intelligent conference system .it can support 60 units delegate and chairman microphone, it could be extended to support 200 units microphone by adding more Extension power supply unit , suitable for government, restaurants, conference rooms, training and education, the board of directors of the company meeting room with Frequency response 100 Hz - 16000 Hz, Input Voltage 18V, Limit Switch and Free speech Mode.

2

-

-

... More
Supply, Installation,Testing & Commissioning of Intelligent conference system, Flush mount boundry layer Chairman microphone unit , speaking button and LED for the indication, With president priority key; Chairman microphone should having highest priority and should be able to terminate all microphone. Frequency Response 40-16KHz, Sensitivity -42dB±2dB,Reference sound-receiving distance 20-120cm.

4

-

-

... More
Supply, Installation,Testing & Commissioning of Intelligent conference system, Flush mount boundry layer delegate microphone unit, speaking button, LED for the indication and with Frequency Response 40Hz - 16KHz, Sensitivity -42dB±2dB,Reference sound-receiving distance 20-120cm.

90

-

-

... More
Power Supply for Delegates/Chairmen Units

2

-

-

... More
Supply Installation Testing & Commissioning of Touch Control Network Controller System with 32-bit embedded processor of frequency max 533MHz, built-in 8M memory storage and 16M FLASH storage, to be high-speed computing complex logic instructions. Its highly integrated chip to support to the CPU, allowing a variety of complex arithmetic and control to run smoothly. 8 independent programmable RS-232 control interface, 8 independent programmable IR infrared transmitter port, 8 -channel digital I / 0 input and output port, with protection circuit, 8 -channel low current relay control interface, Embedded intelligent IR learning module,

4

-

-

... More
Supply Installation Testing & Commissioning of Infrared Cable for Integration with IR Devices.

4

-

-

... More
Supply Installation Testing & Commissioning of 8.4 inch Touch Screen Display 16:9 high-resolution color and high-denition widescreen display. one-way communication through a wireless wifi and a programmable central control host. Interface can be user-dened, PNG, JPG and other common image formats. Graphical interface supports text, 3D buttons.

-

-

-

... More
Supply Installation Testing & Commissioning of 8 Port Wifi Router.

4

-

-

... More
Supply Installation Testing & Commissioning of of Blu ray DVD Player.

4

-

-

... More
Supply, installation, testing and commissioning of 8 x 8 HDMI Matrix Switcher with HDCP Compliant, HDMI and HDCP as per technical specification. Input and Output: supporting 8 signal input and 8 signal outputs. Card-insert construction: input signal types: VIDEO, VGA, YPbPr, DVI, HDMI, 3G-SDI, Fiber, HDBaseT; output signal types: HDMI, VGA format, DVI, HD BaseT, Fibre. Card design is easy for extension and change. Supporting any output of DVI, HDMI, HD BaseT, Fibre. Seamless switching function. Supporting embedded dual IR and RS-232 control signal switching function (need to match up with HD BaseT, FB board card and relevant transmitter) Supporting HDCP management, encryption and decoding HDCP content can be set up to make sure that the display of signal source is normal. Supporting EDID management, it can stock 8 groups EDID datas. The output equipment EDID can be read and the stocked EDID can be used to any input card, which can send the EDID code to EDID storage area by the serial port and the current output EDID code can be read by the serial by the serial port. power-failure memory function and site memory function, and power-failure site protection function; it can preserve and invoke 10 switching status.Supporting forward direction high speed channel and embedded control signal separation switching mode. Supporting entire HD: HDPC:1920x1200P@60_24bit, HSTV:1920x1080@60_36bit, Supporting entire HD: HDMI 1.4, HDCP 1.4, and DVI 1.0 protocol. Supporting high color depth and high 3.25Gbps speed. 2 RS-232 communication interfaces.1 network interface and can be remote controlled by Ethernet, supporting 8 user connection simultaneously.

2

-

-

... More
Supply, installation, testing and commissioning of 16 X 16 HDMI Matrix Switcher with HDCP Compliant, HDMI and HDCP as per technical specification. Input and Output: supporting 16 signal input and 16 signal outputs. Card-insert construction: input signal types: VIDEO, VGA, YPbPr, DVI, HDMI, 3G-SDI, Fiber, HDBaseT; output signal types: HDMI, VGA format, DVI, HD BaseT, Fibre. Card design is easy for extension and change. Supporting any output of DVI, HDMI, HD BaseT, Fibre. Seamless switching function. Supporting embedded dual IR and RS-232 control signal switching function (need to match up with HD BaseT, FB board card and relevant transmitter) Supporting HDCP management, encryption and decoding HDCP content can be set up to make sure that the display of signal source is normal. Supporting EDID management, it can stock 8 groups EDID datas. The output equipment EDID can be read and the stocked EDID can be used to any input card, which can send the EDID code to EDID storage area by the serial port and the current output EDID code can be read by the serial by the serial port. power-failure memory function and site memory function, and power-failure site protection function; it can preserve and invoke 10 switching status.Supporting forward direction high speed channel and embedded control signal separation switching mode. Supporting entire HD: HDPC:1920x1200P@60_24bit, HSTV:1920x1080@60_36bit, Supporting entire HD: HDMI 1.4, HDCP 1.4, and DVI 1.0 protocol. Supporting high color depth and high 3.25Gbps speed. 2 RS-232 communication interfaces.1 network interface and can be remote controlled by Ethernet, supporting 8 user connection simultaneously.

2

-

-

... More
Supply, installation, testing and commissioning of AV Transmitter and Receiver, Support Video, S-video, YPbPr (YCbCr), VGA (RGBHV), DVI, HDMI input; Support analogue stereo input and output, HDMI comes with digital audio input and output; Support bi-directional IR, RS-232 transmission out; Be able to change output resolution via serial commands or panel dial switch; Be able to select video source via serial commands or panel button; Support video scaling, noise reduction, de-interlacing, brightness, contrast adjustment, resolution times the line to 1920X1080P @ 60Hz;V Support HDMI monitor output; Support for video, audio, IR, RS-232 simultaneous transmission, CAT5e / 6 shielded cable maximum transmission distance of 100 meter

2

-

-

... More
Supply, installation, testing and commissioning of HDMI Digital Video Twisted Pair Transmitter, Support HDMI1 .4a, Compatible HDCP1.4, DVI 1.0, Support for bi- directional IR, RS-232 Transmission, Should support HDMI Monitor Output, Compatible with HDMI 1.4 standard, HDCP1.4 agreement, Pixel bandwidth 225MHz, Full Digital, Interface Bandwidth 3.25Gbps, Infrared Control Interface.

2

-

-

... More
Supply, installation, testing and commissioning of HDMI Digital Video Twisted Pair Receiver, Support HDMI1 .4a, Compatible HDCP1.4, DVI 1.0, Support for bi- directional IR, RS-232 Transmission, Should support HDMI Monitor Output, Compatible with HDMI 1.4 standard, HDCP1.4 agreement, Pixel bandwidth 225MHz, Full Digital, Interface Bandwidth 3.25Gbps, Infrared Control Interface

2

-

-

... More
Supply, installation, testing and commissioning of Wireless presentation device which supports video resolution upto 1080p (Full HD), with 1xHDMI / DVI/ DP output, PoE enabled Ethernet port, 1xUSB port for data sharing , Supports Windows laptops and MAC, as well as iOS, Windows and Android mobile operating systems, display minimum 2 users screen simultaneously on a single display through hardware dongle/ software app. Supports DHCP, Audio out. Support 40 or more concurrent users. Support Full HD video of 1080p @ 30fps or more etc as required at site.

2

-

-

... More
Supply, installation, testing and commissioning of HDMI Audio Deembedder, with 1 HDMI connector Input & 1 HDMI connector, 1 TOSLINK® optical digital audio connector, 1 S/PDIF digital audio on an RCA connector, 1 unbalanced stereo audio on a 3.5mm mini connector Output as per technical specification.

2

-

-

... More
Supply, Laying, testing and commissioning of 2 Core 1.5 Sq MM Speaker Cables. Flexible Copper Conductor of cross section 1.5 Sq. mm / 2.5 Sq. mm insulated, PVCFRLS sheathed control Cable as per IS 694

400

-

-

... More
Supply, Laying, testing and commissioning of 18 AWG -24/0.20mm x 2 core Microphone Cable.

350

-

-

... More
Supply and Fixing of HDMI Cable - 5 Meter.

8

-

-

... More
Supply and Fixing of HDMI Cable - 15Meter.

48

-

-

... More
Supply & Fixing of cables and Connector for HDMI Cable,VGA Cable, Speaker Cable for above system OEM Approved.

2

-

-

... More
Supply, installation, testing and commissioning of 19" Rack for the mounting of Equipment as per approved OEM - 18U by OEM Approved.

2

-

-

... More
FOR SEMINAR HALL ROOM

-

-

-

... More
Video Projection System

-

-

-

... More
Projection System with 1 CHIP DLP Technology, laser diaode with native resolution of 1920 x 1200 , 5000 ANSI lumens , 16:10 aspect ratio HD, 1.8x manual zoom (throw ratio 1.22-2.26:1), manual focus F 1.6-2.2, f 17.1-31.7 mm, H/V Lens Shift and 2x Zoom Lens, 360 degree flexible angle setting, lamp life 20000 hrs. HD base-T, Multiscreen Suppot. Projector Should be supplied with Ceiling Mount Kit.

1

-

-

... More
250" Diagonal Motorized Projector Screen with Tensioned.

1

-

-

... More
8 x 8 HDMI Matrix Switcher with HDCP Compliant, HDMI and HDCP as per technical specification. Input and Output: supporting 8 signal input and 8 signal outputs. Card-insert construction: input signal types: VIDEO, VGA, YPbPr, DVI, HDMI, 3G-SDI, Fiber, HDBaseT; output signal types: HDMI, VGA format, DVI, HD BaseT, Fibre. Card design is easy for extension and change. Supporting any output of DVI, HDMI, HD BaseT, Fibre. Seamless switching function. Supporting embedded dual IR and RS-232 control signal switching function (need to match up with HD BaseT, FB board card and relevant transmitter) Supporting HDCP management, encryption and decoding HDCP content can be set up to make sure that the display of signal source is normal. Supporting EDID management, it can stock 8 groups EDID datas. Supporting entire HD: HDPC:1920x1200P@60_24bit, HSTV:1920x1080@60_36bit, Supporting entire HD: HDMI 1.4, HDCP 1.4, and DVI 1.0 protocol. Supporting high color depth and high 3.25Gbps speed. 2 RS-232 communication interfaces.1 network interface and can be remote controlled by Ethernet, supporting 8 user connection simultaneously. Video Wall Controller Should be Included with the Switcher Make - AMX/Extron/Heinrich

1

-

-

... More
HDMI Transmitter and Receiver Support HDMI1 .4a, Compatible HDCP1.4, DVI 1.0, Support for bi- directional IR, RS-232 Transmission, Should support HDMI Monitor Output, Compatible with HDMI 1.4 standard, HDCP1.4 agreement, Pixel bandwidth 225MHz, Full Digital, Interface Bandwidth 3.25Gbps, Infrared Control Interface Make - AMX/Extron/Heinrich

1

-

-

... More
HDMI Audio Deembedder, with 1 HDMI connector Input & 1 HDMI connector, 1 TOSLINK® optical digital audio connector, 1 S/PDIF digital audio on an RCA connector, 1 unbalanced stereo audio on a 3.5mm mini connector Output as per technical specification. Approved Make - Kramer/Extron/Heinrich.

1

-

-

... More
Intellectual Digital Podium Broadcasting system with LCD display, U socket and Mic/Line Inputs. Frequency Response 100Hz~16, 000Hz, S/N Ratio 45dB .

1

-

-

... More
Presentation Point Having HDMI Input Approved Make - Kramer/Extron/Heinrich.

1

-

-

... More
HDMI Cable. Make - Belden/Heinrich

100

-

-

... More
Supply Installation Testing & Commissioning of Connector accessories.

1

-

-

... More
Sound Reinforcement System

-

-

-

... More
Supply Installation Testing & Commissioning of 15" Two-Way System in a Trapezoidal Enclosure; 600W @ 8 ohm Continues Power Frequency 45Hz to 20KHz sensitivity 100dB

6

-

-

... More
Supply Installation Testing & Commissioning of Array Frame for Suspending up to 6 Enclosures with 10:1 Design Factor. Includes 4 x Quick Release Pins, 2 x Shackles, 2 x Drop Levers. (For Speaker Installation)

2

-

-

... More
Supply Installation Testing & Commissioning of Side Wall Speaker Mounting Braket.

6

-

-

... More
Supply Installation Testing & Commissioning of 2 x 18" Bass reflex Subwoofer system with 1000 watt or better Frequency response 25-200HZ long term power handling, 220 Megnatism with dual 18" LF driver.

2

-

-

... More
Supply Installation Testing & Commissioning of Two-Way Monitor System 70 Hz - 18 kHz (-10dB) frequency response, 95 dB SPL sensitivity @ 1W / 1m, long term power handling 200W, max sensitivity 115dB.

2

-

-

... More
Supply Installation Testing & Commissioning of 6"+1.5" Coaxial Ceiling speaker with ABS cover, 40W, 100V, cutout 185mm, ABS baffle & back cover, metal grille. The Speaker shall have following Feature: Max SPL 102 dB, Frequency Response 90-20kHZ. The Speaker shall have Multiple tapping

2

-

-

... More
Supply Installation Testing & Commissioning of Power amplifier, Dual channel 1600 + 1600 Watts RMS @ 8 ohms,Sterio power THD0.1%, S/N Ratio 112dB Front-to-rear air ow, temperature controlled speed, Short circuit,open circuit,direct voltage,high temperature, radiofrequency, ultralow frequency, current peak limitery input connector 3-pin XLR, electronically balanced (Loc: Projector Room)

4

-

-

... More
Supply Installation Testing & Commissioning of 120W RMS dual Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving. Amplifier shall have Following Features: 120W RMS per Channel, Amplifier Output 100V, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD 0.1%, Frequency Response 20Hz - 20kHz, AC & DC Fuse, SNR 80dB. (For Ceiling speakers) Loc: Projector room

1

-

-

... More
Supply Installation Testing & Commissioning of 32 channels Mixing console with Mono Input 24 Channel, Stereo Input 4 group, Mono Insertion Channel 24 Channel, Phantom power 48V, Frequency Response 20Hz - 20kHz, Channel Crosstalk less than 90dB, S/N Ratio 83 dB, Gain difference between Channel less than 2 dB, Distortion degree less than 0.02%, 21 Kind of DSP Effects. (Loc: Projector room)

1

-

-

... More
Supply Installation Testing & Commissioning of 8-channel Phantom Power Microphone/Line input, 8- channel circuit Output; Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD 0.003%, Channel Seperation 92dB,Seperate Mute Control each channel,CMRR80dB, 8 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC,High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable.Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing.

1

-

-

... More
Supply Installation Testing & Commissioning of 50cm gooseneck cardioid Microphone, table top type polar pattern super heart-shape sensitivity -35dB frequency 60-14Khz output impedance 200Ohm operating Voltage DC9V(At podium)

1

-

-

... More
Supply Installation Testing & Commissioning of Dynamic Vocal Microphone with cardioid polar pattern, frequency response 70Hz - 20kHz (@ 1 cm: 20Hz - 18kHz), THD 147/156 dB,Impedence =600 ohms (Stage performance)

1

-

-

... More
Supply Installation Testing & Commissioning of Floor Box for Connecting Mic ( 2 XLR Connector ).

2

-

-

... More
Supply, Installation,Testing & Commissioning of handheld Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-15,000 Hz, Surge mode PLL Phase lock, Dynamic Range 90dB, THD 0.5%, S/N ratio 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption 85mA.

2

-

-

... More
Supply, Installation,Testing & Commissioning of Lapel Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-15,000 Hz, Surge mode PLL Phase lock, Dynamic Range 90dB, THD 0.5%, S/N ratio 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption 85mA. -

2

-

-

... More
Supply Installation Testing & Commissioning of Microphone Tripod stand with Short Arms of Aluminium.

2

-

-

... More
Supply Installation Testing & Commissioning of Microphone Tripod stand with Long Arms of Aluminium.

2

-

-

... More
Supply Installation Testing & Commissioning of Proffessional DVD player make Philips or equivalent.

1

-

-

... More
Supply Installation Testing & Commissioning of Wiring for Speaker 2x1.5sqmm sheilded cable system including miscellaneous connectors in PVC conduits.

500

-

-

... More
Supply Installation Testing & Commissioning of 19" Rack Mount Enclosure for Installing all sound reinforcement System and Video Project System. 24 U.

1

-

-

... More
Supply and fixing of 2C x 1.5 Sq.mm sheilded Microphone cable.

500

-

-

... More
Supply Installation Testing & Commissioning of Connector accessories.

1

-

-

... More
SUBHEAD - XXII : EPABX SYSTEM

-

-

-

... More
Supply Installation Testing and Commissioning of IP EPABX Fully Computerized IP System, SIP Compliant. ,Expandable upto 2000 Ports Extension .and configured as for below Ports P & T(CO Trunk) Line 08 Nos. PRI(30 Channel) 2 Nos. IPExtension 50 Nos. Digital extension 50 Nos Analog Ext 200 Nos with Voice mailand Confrence facility

1

-

-

... More
Supply Installation Testing and Commissioning of IP Phone (40 Key+ 40-line DSS Console) Backlit keypad Hands-free, full duplex ,Headset support Easy to use soft keys/LCD prompts,Directory dialling,Navigation wheel,Call history,Backlit LCD screen,Bluetooth support.

1

-

-

... More
Supply Installation Testing and Commissioning of IP Phone 40 Key Backlit keypad Hands-free, 3 Line display ,full duplex ,Headset support Easy to use soft keys/LCD prompts,Directory dialling,Navigation wheel,Call history,Backlit LCD screen.

50

-

-

... More
Supply Installation Testing and Commissioning of IP Phone (6Key)Backlit keypad Hands-free, full duplex Headset support Easy to use soft keys/LCD prompts Directory dialling Navigation , Backlit LCD screen.

50

-

-

... More
Supply Installation Testing and Commissioning of Push Butten telephone with CLI , Make Beetel M71 CLI Corded Phone (Black) or equivalent.

200

-

-

... More
Supplying, Installation, Testing & Commissioning of of 300 Pair MDF/IDF.

2

-

-

... More
Supply Installation Testing and Commissioning of Server Rack 12 U.

1

-

-

... More
Supply Installation Testing and Commissioning of Switch POE 48 Port.

2

-

-

... More
Supply Installation Testing and Commissioning of Patch Cord.

180

-

-

... More
SUBHEAD - XXIII : IBMS SYSTEM

-

-

-

... More
BMS SERVER/ OPERATOR WORKSTATION

-

-

-

... More
BMS Computer System: Supply, installation, testing and commissioning of BMS operator workstation having Intel i7 or latest Generation processor with latest technology or Equivalent Server PC, 3.5 GHz, with 16 GB RAM, & 1 TB HDD, 10/100 Mbps Ethernet card, 52X DVD Writer, USB connection & internal modem, Microsoft(R) Windows(R) 10 OS Professional Enterprise with original license, protection & restore key, Web server software, with 32" colour graphics monitor as per Tender Specifications, reputed Anti-virus with subscription till DLP period etc. etc. System should store data for 36 Months. Accessories included Mouse, Key Pad, Laserjet, Scanner colour A4 printer with the above BMS System configuration. This is minimum specification, vendor has to provide equivalent of higher specs for server for operating the system, it shall be vendors responsibility to provided efficient server as per requirement to run the system without any lag/or delay .

1

-

-

... More
Providing, Installing, Testing & Commissioning of IGBT based micro processor controlled True On line double conversion 1 Phase input and 1 Phase output online UPS with 15 min (0.8 PF) . UPS offered shall be modular & battery back up time for powering to DDC's, Motorised Valves and dampers. Power distribution DB in BMS room to be considered. Including all accessories & power switch socket , Modbus communication card , Battery rack etc. UPS to be BMS compatible. ** Note: It is responsibility of vendor to order correct size of UPS as per load requirement and above mentioned rating is indicative. Cost of metal DB box for UPS along with MCB/MCCB/ELCB for incoming and outgoing along with any other accessories or misc. cables of different sq. mm shall be scope of vendor. Vendor to consider 20% or 3 kVA additional which ever is higher.

1

-

-

... More
BUILDING MANAGEMENT SYSTEM WEB-BASED SERVER SOFTWARE

-

-

-

... More
SITC of the BMS Software with user license web based Server Software for Building Management System with dynamic graphics with unlimited user license capacity for remote monitoring. The Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Edge,Google Chrome, Mozilla Firefox etc. Software should have license point as per I/O Summary with minimum 15% spare points.Building Management Software with features like 3D graphics with Autocad image import of plan with Zoom In & Zoom Out facility, Plant Viewer, Trend Viewer, Object Viewer, Report Viewer, Alarm router including configuration and facility to create / provide the graphic mapping for all I/O Summary points , animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, configurable password protection for Building Mgmt. BMS System shall be in compliance with IEC-61131-3 standards as per Specifications. The software shall be capable of integration third-party systems and should supports latest IP technology (IP v6). Software shall support all open protocols such as BACnet, Modbus, Lonworks, DALI, KNX, MBus, MPBus, Profibus, OPC UA etc.The Management Stations shall include Client License for remote viewing. The software shall have Online Engineering capability i.e. software graphics modification and multi monitor / simultaneous views of critical systems. (Properitary Protocol shall not be accepted). Same software package can be utilized as programming / commissioning software of DDC, NAC etc. 3D Graphics to be latest & advance with suitable animation. Cost for one year support to edit / modify graphics post handover to be included.] Integration with end User BMS System, Sharing all Hardware & Software points on BACnet over IP with capability to accept override / control signal Please Note: All required Software with original license competent with BMS software.

1

-

-

... More
PROGRAMMABLE & APPLICATION SPECIFIC CONTROLLER ( BACnet IP DDC) - ULLISTED.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Standalone, modular. Intelligent, UL listed, BTL/ANSI/ASHRAE approved BACnet I/P, interoperable DDC as per the specification. All the controllers are UL/BTL tested & CE certified. The controller possesses Dual 32 Bit, 1GHz, Microprocessor both for IO Management as well as communication & DHCP enabled with capability of DDC to store the data of 1 month in case of power failure. It should store trend logs and event buffer. DDC Controller shall have a resident real time clock with a battery back up. Controller shall support open progrmming standards i.e. IEC-61131-3. DDC must support trending & scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. For AHU's Maximum of One Controller / per AHU Shall be used. UL Listed BACnet( BTL) B-BC controller and communication with expansion units to field Controller over open protocol such as BACnet I/P or Profinet or any other open ethernet protocol. Proprietry Protocol shall not be accepted. The DDC's shall be capable of peer to peer communication over IP in daisy or RSTP loop topology without help of system interface controller or PC. with lockable MS mounting cabinets provieded with Type-III surge protector device, duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip current transformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point) on BACnet/IP. DDC shall be modular type to fulfill required IO as per site condition. 15% spare capacity for each point type (i.e. AI, AO, DI, DO) required inside each DDC controller/panel Quoted prices shall be inclusive of UPS powered switch socket for each DDC Panel. Panel should include suitably sized Xfmr and / or SMPS to power sensors, actuators for valve / damper etc. Panel to be manufactured as per relevant IS and industry best practices.

-

-

-

... More
All DDC should work standalone in case of communication / main controller failure. (Required cut-outs / Holes for cable entry in Electrical Panel of all 3rd party integration system , additional accessories to ceiling suspend the DDC Panel by means of GI bracket/angle shall be in scope of vendor.) All Cabinet(Panels) for BMS should be supplied with Power Supplies, & surge protection device to protect controller & other equipment from system generated EMPs, Cabinet shall be MS-Powder coated with Lock and key & must have Power indicator on Panel Door. Panel RAL shade shall be conveyed at detailed design stage.

-

-

-

... More
DDC for Exhaust Air, Make up Ventilation fans, Press Fans (upto 3 Fans per DDC).

4

-

-

... More
DDC for Fire fighting system.

1

-

-

... More
DDC for Plubming system.

1

-

-

... More
DDC for HT/LT Panel (Approx. 40 Nos. of IO Points to be considered in 1 Panel).

1

-

-

... More
DDC Panel for DG System Open weather proof rated.

1

-

-

... More
DDC Panel for Lifts / Escalators Open weather proof rated.

1

-

-

... More
SYSTEM INTEGRATION UNITS FOR 3RD PARTY SYSTEM SOFTWARE INTEGRATION - UL listed Controllers

-

-

-

... More
Supply, Installation, Testing & Commissioning of System Integration unit consisting of microprocessor based controller units BTL & UL Listed for third party integration. The same should support operations/ monitoring via portable operator terminal. Third Party Integrator/ Gateway shall have cybersecurity features such as IP whitelisting, IP port disablement etc.The controller shall be Native BACnet type with communication via BACnet, LonTalk, Modbus over RS-485, TCP/IP. Integration platforms and system controllers for third-party devices and systems via Modbus, J-Bus and other protocols into the automation level via BACnet. The same shall Support operation via local or network-compatible operator units. It should store trend logs and event buffer. Third Party make controller shall not be accepted. Offered Integrator/Gateway/Protocol Converter shall be of same OEM as DDC Controller & Software.

-

-

-

... More
Chiller Panel.

1

-

-

... More
VRF ODU - (29 No).

1

-

-

... More
STP Plant Manager either on BACnet over IP / Modbus.

1

-

-

... More
UPS Integration - 2 Nos. either on BACnet over IP / Modbus/ SNMP.

1

-

-

... More
DG Integration either on BACnet over IP / Modbus.

1

-

-

... More
Energy Meters/ Multifunction meters on BACnet over IP / Modbus - 31 Nos. (50 nos. per integrator) (15 pt. / meter).

1

-

-

... More
Fire Alarm System Panel & PA System on BACnet over IP (approx. 3500 devices) [Floor plan with detector to be added in graphics].

1

-

-

... More
Lift Integration. 2 Nos. Interface either on BACnet over IP / Modbus.

1

-

-

... More
Transformers & OLTC on either on BACnet over IP / Modbus (15 pts.).

1

-

-

... More
UPS Integration - 6 Nos. either on BACnet over IP / Modbus/ SNMP.

1

-

-

... More
BTU Meters - 9 nos.

1

-

-

... More
Water Meters either on BACnet over IP / Modbus -2 Nos.

1

-

-

... More
FCU Thermostat ( 16 nos.) over Modbus.

1

-

-

... More
OWC PLC Integration on Modbus or BACnet.

1

-

-

... More
STP Plant Manager either on BACnet over IP / Modbus.

1

-

-

... More
Solar System Integration on Modbus or BACnet (20 pts./panel).

1

-

-

... More
Common Area lighting control either on BACnet over IP / Modbus / TCP-IP.

1

-

-

... More
Air Quality Sensor - either on BACnet over IP / Modbus.

1

-

-

... More
SENSORS AND FIELD DEVICES

-

-

-

... More
Supplying, installing, testing and commissioning of the following sensors / transducers / transmitters

-

-

-

... More
DP Switch -Air - Providing, Installing, Testing & Commissioning of Air Differential pressure switches across the Air Filters for indicating status. Pressure differential – 4mm- 40 mm. The switch shall be with connecting tube and metal bends for connections to the duct. The housing shall be IP-54 rated, including Probe, tubes, accessories etc.

19

-

-

... More
Duct Pressure Sensor - Providing, Installing, Testing & Commissioning of Duct Pressure Sensors, accuracy shall be ± 1% including Integrated Pressure Probe, tubes, accessories etc.

2

-

-

... More
Current Relay.

1

-

-

... More
Bi-level Switch - Providing, Installing, Testing & Commissioning of IP65, Bi-Level Water Switches up to 5Mtr Ht. for indicating level status in sumps & Water Tanks, including accessories etc with 2 NO/NC for indicating high & Low water level in tanks

2

-

-

... More
Water Pressure Sensor - Providing, Installing, Testing & Commissioning of IP65, PN16, Water Pressure Sensor (Pencil type)( 0 to 10 Kg/cm2) and matching sockets and welding job, giving 0-10 VDC/4-20 mA output

2

-

-

... More
IP65 submersible/hydrostatic Level Transmitter, givinf 0-10 VDC/4-20 mA output

2

-

-

... More
Water DP Switch for pump - Providing, Installing, Testing & Commissioning of IP65, PN16 Water Differential Pressure Switch across the Pumps for indicating the Pump status of Pumps complete with all accessories.

12

-

-

... More
DC Voltage Transducers.

2

-

-

... More
Flameproof Level Transmitters - Providing, Installing, Testing & Commissioning of Flame Proof Level Transmitter upto 1.5 Mtr for Diesel Bulk & Day Oil, including accessories etc. Vendor to check the tank height before procurement at the time of execution.

3

-

-

... More
Methane Gas Detector - Providing, installing, testing & commissioning of LEL Methane Gas detector for STP Plant room

1

-

-

... More
WIRING & CONDUITING

-

-

-

... More
Supplying, laying, termination, testing and commissioning of signal, serial communication cables. (2 core 1 mm2), 1,1 Kv, PVC multi-stranded, insulated, shielded, tinned copper conductor, ISI marked, FRLS cable armoured cable.

1380

-

-

... More
Supplying, laying, termination, testing and commissioning of communication cables, LSZH, twisted pair, pvc insulated, ISI Marked CAT 6 STP cable- unarmoured cable.

210

-

-

... More
Supplying and laying of 25mm of Heavy Duty PVC conduit on surface/recess including cutting/filling chases along with conduit accessories etc. complete as required.

210

-

-

... More
Flexible conduit for termination in the DDC Panels : Providing and laying of Heavy duty steel reinforced FRLS 25mm PVC Flexible conduit with coupler at both ends. & shall be as per relevant IS standards & ISI mark.

552

-

-

... More
Supplying, laying, termination, testing and commissioning of communication cables. (2 core 1.5 mm2), PVC insulated, shielded tinned copper conductor cable, Lead free, FRLS, twisted pair, ISI Marked armoured cable.

1420

-

-

... More
Supplying, laying, termination, testing and commissioning of communication cables. (2 core 1.5 mm2), PVC insulated, shielded tinned copper conductor cable, Lead free, FRLS, twisted pair, ISI Marked unarmoured cable.

1420

-

-

... More
Supplying, laying, termination, testing and commissioning of communication cables. (3 core 1.5 mm2), PVC insulated, shielded tinned copper conductor cable, Lead free, FRLS, twisted pair, ISI Marked armoured cable.

90

-

-

... More
Supplying, installing, testing and commissioning of 2 mm thick GI Hot dip Galvanized perforated cable trays of the following sizes complete with angle iron supports/hanging arrangement etc & shall be as per relevant IS standards & ISI mark.

-

-

-

... More
50 x 300 x 50

45

-

-

... More
50 x 200 x 50

20

-

-

... More
50 x 150 x 50

20

-

-

... More
50 x 100x 50

20

-

-

... More
50 x 50 x 50

20

-

-

... More
NETWORKING ACCESSORIES

-

-

-

... More
Supply, installation, testing and commissioning of Layer 2 managed DIN mount industrial switch if required with fiber connectivity, will all necessary accessories such as Network rack, LIUs, Patch panel, patch cords, pigtail, etc complete in all respect, and as required for BMS DDC Panel Networking.

-

-

-

... More
Supply, installation, testing and commissioning of DIN mount, Industrial grade Layer 2 Managed 10/100 Base-T, industrial grade switches Edge network switch 16 Port Non-POE Managed Switch,

2

-

-

... More
Supply, installation, testing and commissioning of DIN mount, Industrial grade Layer 2/3 managed Core network switch 10G, 16 port with SFP port min.2 nos.for fibre connectivity with all necessary accessories.

1

-

-

... More
SUBHEAD - XXIV : SIGNAGES

-

-

-

... More
Supply and fixing of 18 gauge Stainless Steel plates of grade 304 engraved with utility signage all complete as per sample approved and all as per direction of Enginner-in-Charge. ( 6" x 6")

10

-

-

... More
Supply and fixing of 18 gauge Stainless Steel plates of grade 304 engraved with push / pull signage all complete as per sample approved and all as per direction of Enginner-in-Charge. ( 6" x 6").

10

-

-

... More
Powder coated Aluminium Panel for directory of size 24" x 48" supported on aluminium channel 2 nos backside with ACP sheet. Matter will be digital print, matter covered with transprent polycarbonate sheet 0.5 mm.

10

-

-

... More
Providing and fixing 800 mm dia Convex Mirror made of PC front and ABS/metal back supported on Nut & Bolts supported on 75 mm dia 1 No post 9 feet long sign boad fixed with cement aggregate concrete 1:2:4 (1 Cement: 2 Coarse Aggregate: 4 Graded stone 20mm nominal size) as per direction of Engineer-in-charge.

6

-

-

... More
SUBHEAD - XXV : ROAD & HARDSTANDING

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (a) All kinds of soil.

670

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift.

200

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

3020

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (a) With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30.

425

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.

95

-

-

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. If the actual quantity of cement required to be used as a result of the laboratory test is different from that assumed above, necessary adjustment in the cost due to short cement used shall be made on the basis of issue rate of cement including storage charges plus 2.5% for handling charges. However, under no circumstances the quantity of cement to be used shall either exceed 350 kg./cum or fall below 330 kg. per cum of finished concrete (a) Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer

48

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more

5200

-

-

... More
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.

100

-

-

... More
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge.

360

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

75

-

-

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

630

-

-

... More
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. (a) 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

50

-

-

... More
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. (a) 25 mm compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

500

-

-

... More
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :

-

-

-

... More
On W.B.M. @ 0.75 Kg / sqm.

500

-

-

... More
On bituminous surface @ 0.50 Kg / sqm.

500

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (a) (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

860

-

-

... More
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.

226

-

-

... More
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge.(Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS : 1838 for fibre board and IS : 1834 for hot sealing bitumen compound grade A)

1225

-

-

... More
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of Engineer-in-Charge. (a) Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.

1225

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
150 mm dia. R.C.C. pipe

50

-

-

... More
250 mm dia. R.C.C. pipe

50

-

-

... More
300 mm dia. R.C.C. pipe

50

-

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete

-

-

-

... More
450 mm dia RCC pipes.

50

-

-

... More
600 mm dia RCC pipes.

50

-

-

... More
900 mm dia RCC pipes.

50

-

-

... More
SUBHEAD - XXVI : EXTERNAL WATER SUPPLY

-

-

-

... More
GRAVITY MAINS

-

-

-

... More
Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : (a) Up to 300 mm dia.

5

-

-

... More
Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (a) 250 mm diameter pipe.

3

-

-

... More
Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket :

-

-

-

... More
100 mm dia pipes

35

-

-

... More
150 mm dia pipes

3

-

-

... More
250 mm dia pipes

3

-

-

... More
DUCTILE IRON PIPIE, CLASS -K7 & K-9

-

-

-

... More
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :

-

-

-

... More
100mm dia Ductile Iron Class K-7 Pipes

200

-

-

... More
150mm dia Ductile Iron Class K-7 Pipes

80

-

-

... More
200mm dia Ductile Iron Class K-9 Pipes

5

-

-

... More
250mm dia Ductile Iron Class K-9 Pipes

15

-

-

... More
DUCTILE IRON PIPIE, CLASS -K-9

-

-

-

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :

-

-

-

... More
200 mm dia Ductile Iron Double Flanged.

30

-

-

... More
250 mm dia Ductile Iron Double Flanged.

15

-

-

... More
G.I. PIPES

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.

-

-

-

... More
80mm dia nominal bore.

95

-

-

... More
65mm dia nominal bore.

115

-

-

... More
50mm dia nominal bore.

160

-

-

... More
40mm dia nominal bore.

10

-

-

... More
32mm dia nominal bore.

120

-

-

... More
25mm dia nominal bore.

80

-

-

... More
SLUICE VALVES

-

-

-

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :

-

-

-

... More
100 mm dia - Class I

6

-

-

... More
150 mm dia - Class I

3

-

-

... More
250 mm Dia - Class I

2

-

-

... More
DOUBLE ACTING AIR RELIEF VALVE

-

-

-

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :

-

-

-

... More
50mm dia.

2

-

-

... More
80mm dia.

2

-

-

... More
GATE VALVES

-

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
80mm nominal bore.

2

-

-

... More
65mm nominal bore.

2

-

-

... More
50mm nominal bore.

3

-

-

... More
40mm nominal bore.

1

-

-

... More
32mm nominal bore.

3

-

-

... More
25mm nominal bore.

3

-

-

... More
NON-RETURN VALVES

-

-

-

... More
Providing and fixing CI non- return valve of approved quality (Flanged end) :

-

-

-

... More
100mm dia

1

-

-

... More
150mm dia

1

-

-

... More
250mm dia

1

-

-

... More
Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class): (a) Upto 300 mm dia.

3

-

-

... More
Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : (a)Upto 300 mm dia

3

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1 : 1.5 : 3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

6

-

-

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1 : 1.5 : 3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

6

-

-

... More
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1 : 1.5 : 3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

6

-

-

... More
Providing and fixing soil, waste and vent pipes of size 100mm dia. (a) Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989.

3

-

-

... More
Supply, fabrication, fixing and testing of MS puddle flanges of required sizes for out pipes for fire sump. The puddle flanges shall be flanged ends, of the following size.

-

-

-

... More
250 mm

2

-

-

... More
150 mm

2

-

-

... More
50 mm

2

-

-

... More
WATER TREATMENT SYSTEM

-

-

-

... More
Providing, fixing, testing and commissioning skid mounted vertical MSRL Dual Media Pressure Filter fabricated from IS 226/2062 plate 5mm thick for shell and 6mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete. (For domestic water supply system). (a) Capacity 9000 lph. Flow velocity 15m3/hr/m2. Working pressure 2.5 kg./cm2. Design pressure 4 kg./cm2

1

-

-

... More
Providing, fixing, testing and commissioning skid mounted vertical MSRL Activated carbon filter fabricated from IS 226/2062 plate 5mm thick for shell and 6mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete. (For domestic water supply). (a) Capacity 9000 lph. Flow velocity 15m3/hr/m2. Working pressure 2.5 kg./cm2. Design pressure 4 kg./cm2

1

-

-

... More
Providing, fixing, testing and commissioning Bulk Water Meter with direct reading dial in KL, all internal parts and strainer in gun metal/brass. (a) 50mm dia.

1

-

-

... More
Providing, fixing, testing and commissioning direct reading rate of flow Rota Meter. (a) For 50 mm dia for 9000 lph rate of flow for filter.

1

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.

2

-

-

... More
Providing, fixing, testing and commissioning of chlorinator with metering pump mounted on HDPE white tank suitable for operation on 220 ± 5% single phase, 50 Hz AC supply, including cables from metering pump to control panel compete in all respects. (a) Suitable for flow rate 9000 lph.

1

-

-

... More
SUCTION AND DELIVERY PIPES AND VALVES FOR WATER SUPPLY PUMPS

-

-

-

... More
Providing, fixing, testing and commissioning G.I. suction & delivery headers / pipes for water supply pumps (IS:1239 'C' class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange & blank flanges etc) and clamps all complete. Note: All pipes & fittings in pump room will be weldeded flanged types.

-

-

-

... More
150 mm nominal bore

20

-

-

... More
100 mm nominal bore

50

-

-

... More
80 mm nominal bore

30

-

-

... More
65 mm nominal bore

20

-

-

... More
Providing, fixing, testing and commissioning lever operated gun metal Ball Valve with SS ball. (a) 65mm dia.

6

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified.

-

-

-

... More
150mm dia

1

-

-

... More
100mm dia

2

-

-

... More
80mm dia

5

-

-

... More
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.

-

-

-

... More
100mm dia

2

-

-

... More
80mm dia

8

-

-

... More
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.

-

-

-

... More
100mm dia

2

-

-

... More
80mm dia

2

-

-

... More
Providing and fixing Non- return valve with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN16 pressure rating. (a) 65 mm nominal bore Horizontal.

2

-

-

... More
Providing, fixing, testing and commissioning reinforced Neoprene Flexible Pipe connectors with all accessories on all pumps delivery & suction . Suitable for 20 Kg/cm2

-

-

-

... More
65mm

2

-

-

... More
100mm

2

-

-

... More
TUBEWELL & TUBEWELL PUMPS (2 NOS.)

-

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil (a) 300 mm dia

600

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. (a) 150 mm nominal size dia.

180

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. (a) 150 mm clamp.

3

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

144

-

-

... More
Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS : 2800 (Part I). (a) 150 mm dia

3

-

-

... More
Providing, fixing, testing and commissioning casing Shoe, well cap clamp and welding complete.

3

-

-

... More
Providing, fixing, testing and commissioning single / multistage submersible tubewell pump suitable for 150mm bore with stainless steel casing, NORYL impeller, stainless steel shaft and built in non return valve coupled with submersible squirrel cage motors suitable for 145V ± 10% volts. 3 phase, 50 cycles AC supply. Capacity 200 lpm. Head 75m (Head of pump varies depending upon aquifer.The contractor shall quote acoordingly)

3

-

-

... More
Providing, fixing, testing and commissioning 65mm dia GI column pipe of heavy class duly flanged.

410

-

-

... More
Providing, fixing, testing and commissioning gunmetal pressure gauge (100mm dia) of rating (0-10 kg/cm2) with gunmetal isolating cock and connecting pipe.

2

-

-

... More
Providing, fixing, testing and commissioning 65mm cable clips with nuts & bolts.

25

-

-

... More
Providing, fixing, testing and commissioning 65mm dia supporting clamps with nuts and bolts.

2

-

-

... More
Providing, laying, jointing, testing, & commissioning 3C - 6 sq.m submersible cable.(Quantity of cable may vary depding upon the the depth of water aquafire at site.)

410

-

-

... More
Providing, fixing, testing and commissioning Butterfly valve of cast body with stainless steel disc and stainless steel stem, teflon bushing and niterite o'rings. (a) 65mm dia.

2

-

-

... More
Providing, fixing, testing and commissioning steel wire rope 6mm dia complete with wire rope clamps for safety of pump set.

410

-

-

... More
Providing, laying, jointing, testing, & commissioning 1.1KV grade aluminium conductor PVC insulated and PVC sheathed armoured cables including 8 SWG GI earth wire on surface/cable trays as required. (a) 3 Core - 6sq.mm.

60

-

-

... More
Providing, fixing, testing and commissioning of dust, damp and vermin proof, wall mounted factory built sheet steel enclosed nondrawout modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections & indications and mounted with the following including all inter connection etc. (Including earthing). (for Tubewell pump) 32 amps incoming MCB (1 No.) Panel type volt meter 96mm square with Rotary selection switch for reading voltage between phase and neutral or incoming feeder. (1 set) Phase indicating lights with toggle switches and shall be protected by 2 amps MCB's. (1 set) Ampere meter 96mm square panel type of appropriate range. (1 set) 32 amps outgoing MCB (1 No.) Fully automatic DOL starters with push buttons indicating lights and overload relay each for tubewell pump. (1 No.) Single phasing preventors. (1 No.) Rotary manual/auto/off switch. (1 No.) Space of one liquid level controller

2

-

-

... More
SUBHEAD - XXVII : SEWAGE DISPOSAL

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (a) All kinds of soil.

100

-

-

... More
Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil. (a) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.

700

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift.

80

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : (a) With Sewer bricks conforming to IS : 4885

20

-

-

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : (a) With Sewer bricks conforming to IS : 4885.

20

-

-

... More
Extra for depth for manholes : Size 90x80 cm (a) With Sewer bricks conforming to IS : 4885.

10

-

-

... More
Size 120x90 cm (a) With Sewer bricks conforming to IS : 4885.

10

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
150 mm dia. R.C.C. pipe

400

-

-

... More
250 mm dia. R.C.C. pipe

300

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :

-

-

-

... More
150 mm diameter S.W. pipe

400

-

-

... More
250 mm dia. S.W. pipe

300

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

1

-

-

... More
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

1

-

-

... More
Providing and fixing of PVC rungs suitable for fixing to UG sump / OH tank and similar locations of size 265mm length x 175mm wide x 25mm thick, reinforced inside with 10mm steel rod. The rungs shall be fixed with cement mortar and they shall be capable of withstanding 200 kg load under properly fixed condition, etc., all complete for finished item of work.

160

-

-

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : (a) For pipes 100 to 250 mm diameter.

10

-

-

... More
Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) with all centering and shuttering required, cutting holes in walls and making good with brick work in cement mortar 1:4 (1 cement : 4 coarse sand) plastered with cement mortar 1:3 (1 cement : 3 coarse sand) on inside of the manhole wall, lead caulked joints between sand cast iron pipes and fittings, stiff cement mortar 1:1 (1 cement : 1 fine sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications :

-

-

-

... More
100 mm dia sand cast iron drop connection.

5

-

-

... More
150 mm dia sand cast iron drop connection.

5

-

-

... More
Extra for depths beyond 60 cm of sand cast iron drop connection complete:

-

-

-

... More
For 100 mm dia sand cast iron drop connection

5

-

-

... More
For 150 mm dia sand cast iron drop connection

5

-

-

... More
Design, Supply, erection and Commissioning of packaged sewage treatment plant including civil works of capacity 120 m3 per day of Ion Exchange / Thermax or approved equivalent brand which consists of bar screen chamber, oil and grease trap chamber equalisation tank, FAB Feed pumps including Motors, Air blowers including motors, FAB reactors, Tube settlers, Sludge holding tank, Chlorine dosing system, V Notch plate, Filter feed pumps, Activated Carbon filter, centrifuge system, gear box, motor, MCC panel, any other equipment as required for tertiary system of treatment including supply, erection and testing of inter connecting pipe works, cabling, earthing with cable tray etc., all complete including of all civil and mechanical work for finished item of work to the satisfaction of Engineer-in-Charge. NOTE: 1. The free trial runoff period for the STP shall be one month or till stabilization of STP units to provide desired treatment efficiencies which ever is later. 2. The treatment shall be to the standards of tertiary treatment satisfying the following outlet parameters. BOD 5 mg /l , COD 30 mg/l, total suspended solids 5 mg/l, PH value 6.5 - 8.0, oil and grease 10 mg/l, temperature 25 - 30 degree centigrade. 3. The operation maintenance period of STP shall be 3 Years after Commissioning of STP to stabilise in functioning. Only the following civil works shall be paid separately - 1) Bar screen pit 2) Oil & grease trap chamber 3) Equilisation tank 4) Chlorine contact tank 5) Filter feed tank 6) Treated water tank 7) Sludge holding tank 8) FAB Reactors 9) Tube settler 10) Platforms for dosing tank and foundations for equipment.

-

-

-

... More
The items listed below shall be under the scope of supply. i) Bar Screen (1 No) - Suitable for 120 KLD FAB. ii) Air grid for equalisation tank (1 Lot) - Suitable for 120 KLD FAB. iii) FAB feed pumps (2 Nos- 1 W+ 1 S) - Suitable for 120 KLD FAB. iv) Motors for FAB feed pumps (2 Nos- 1 W+ 1 S)- Suitable for 120 KLD FAB. v) Air Blowers (2 Nos- 1 W+ 1 S) - Suitable for 120 KLD FAB. vi) Motors for Air Blowers (2 Nos- 1 W+ 1 S) - Suitable for 120 KLD FAB. vii) FAB Reactors Media (1 Lot) - Suitable for 120 KLD FAB. viii) Air grid for FAB Reactors (1 Lot) - Suitable for 120 KLD FAB. ix) Tube settler media (1 Lot) - Suitable for 120 KLD FAB. x) Trough weir (1 Lot) - Suitable for 120 KLD FAB. xi) Air grid for sludge holding tank (1 Lot) - Suitable for 120 KLD FAB. xii) Chlorine dosing system (1 No) - Suitable for 120 KLD FAB. xiii) V notch plate (1 No) - Suitable for 120 KLD FAB. xiv) Filter feed pumps (2 Nos (1W+1S)) - Suitable for 120 KLD FAB. xv) Dual media filter (1 No) - Suitable for 120 KLD FAB. xvi) Activated carbon filter (1 no) - Suitable for 120 KLD FAB. xvii) Inter connecting piping and valves for air line (1 Lot) - Suitable for 120 KLD FAB. xviii) Inter connecting piping and valves for sewage line (1 Lot) - Suitable for 120 KLD FAB. xix) Instruments (1 Lot) - Suitable for 120 KLD FAB. xx) Distribution board (1 no) - Suitable for 120 KLD FAB. xxi) Electricals (1 Lot) - Suitable for 120 KLD FAB. xxii) Centrifuge system (1 Lot) - Suitable for 120 KLD FAB. xxiii) Pressure gauges (1 Lot). xxiv) Air Rotameter (1 No). xxv) Level switches (1 Lot).

1

-

-

... More
SUBHEAD - XXVIII : AREA DRAINAGE

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (a) All kinds of soil.

1340

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift.

530

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).

78

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

210

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1575

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more

16000

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1000

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. (a) All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum.

245

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand).

25

-

-

... More
Providing and applying 20mm thick plastering in sumps / OHT / Drains and similar locations with cement mortar 1:3 (1 cement: 3 coarse sand) with water proofing compound mixed as per manufacturer instruction, a floating coat of neat cement including benching, haunching, providing over flow pipes and proper slopes, all as directed by Engineer-in-charge. (including cost of water proofing compound)

1000

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

25

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

15

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.

30

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1: 1.5 : 3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

5

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1 : 1.5 :3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

5

-

-

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1: 1.5 : 3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

5

-

-

... More
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1: 1.5 : 3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

5

-

-

... More
SUBHEAD - XXIX : EXTERNAL ELECTRIC SUPPLY

-

-

-

... More
HT PANEL: 11 kV CIRCUIT BREAKER

-

-

-

... More
Supply, unloading, installation in correct aligned position, testing and commissioning of indoor type, floor mounted metal clad, 11 kV, VCB Panel with (1) No. VCB Panel, totally enclosed & electrically interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as per specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and closing breaker suitable for use on 11 kV, 3Phase, 50Hz A.C. supply with short circuit fault level of 26.2 kA, complete with self contained electrically interlocked rack in and rack out mechanism, breaker featured with mechanical ON/ OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4NO + 4NC and equipped with following switchgears and accessories i/c connections suitable for cable and o/g connections suitable for 3C x 240 sq.mm. XLPE 11 kV cable (cable entry from bottom). Incoming cum Outgoing '- 1 No. 630 Amp. electrically operated VCB with earth switch. - 1 No. 11 KV / √3 : 110 / √3 Volt, PT CL: 0.5 and 200VA burden with 1 no.Multi function Meter with RS 485 to measure voltage, current, power factor, frequency, kW , kVA, kWH, kVAh., and protection MCB fuse at primary of PT and MCB at secondary. - 110 V DC tripping coil. - 110 V DC closing coil. - Spring charging motor. - Set of ON/OFF/TRIP indicating lamps and phase indicating lamp. - Clear lamp for Trip Circuit healthy supply. - Aux. relays for Anti Pumping & fault indication. - 2 over current IDMT microprocessor relay with instantaneous high set element range 50 – 200% - Earth fault relay range 20 – 80% with series stabilizing resistor and PS class CT’s. - Restricted Earth Fault relay with CT's. - Tripping relay for each type of Fault. '- Dual core dual ratio 3 CTs 75-150/5A of 15VA burden and accuracy Class -0.5 for metering and class 5P10 for protection.

-

-

-

... More
- Common alarm annunciator with windows and buzzer, ACK, rest, test push button for all transformer faults and electrical faults. '- Suitable space for termination of 1 No. 3 C x 240 sq.mm XLPE cable as outgoing. 'HT PANEL: 11 kV CIRCUIT BREAKER described as above. Note: a. Potential free contact for BMS integration for ON, OFF, TRIP, AUTO, MANUAL & relays status contact. FOR all incomer & outgoing feeders. b. Suitable rating Power pack including charger, Batteries etc complete as required for complete Panel Board.

1

-

-

... More
11 kV HT PANEL ( 1 I/C & 3 O/G Panel)

-

-

-

... More
Design, manufacture, supply, unloading and shifting to store, installation in correct aligned position, testing and commissioning of indoor type, floor mounted metal clad, 11 kV, VCB Panel with (1) No. I/C VCB & (3) No. O/G VCB Panel, totally enclosed & electrically interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as per specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and closing breaker suitable for use on 11 kV, 3Phase, 50Hz A.C. supply with short circuit fault level of 26.2 kA, complete with self contained electrically interlocked rack in and rack out mechanism, breaker featured with mechanical ON/ OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4NO + 4NC and equipped with following switchgears and accessories i/c / o/g connections shall be as per the SLD (cable entry from bottom). Incomer:- '- 1 No. 630 Amp. electrically operated VCB with earth switch. '- 1 No. 11 KV / √3 : 110 / √3 Volt, PT CL: 0.5 and 200VA burden with 1 no. Multi function Meter with RS 485 to measure voltage, current, power factor, frequency, kW , kVA, kWH, kVAh., and protection MCB fuse at primary of PT and MCB at secondary. - 1 No. Microprocessor based numerical relay with O/L, E/F and S/C protection. '- Breaker control switch. '- 110 V DC tripping coil. '- 110 V DC closing coil. '- Spring charging motor. '- Set of ON/OFF/TRIP indicating lamps and phase indicating lamps. '- Clear lamp for Trip Circuit healthy supply. '- Aux. relays for Anti Pumping & fault indication. '- over current IDMT microprocessor relay with instantaneous high set element range 50 – 200%. '- Earth fault relay range 20 – 80% with series stabilizing resistor and PS class CT’s. '- Restricted Earth Fault relay with CT's. '- Tripping relay for each type of Fault.

-

-

-

... More
- Dual core dual ratio 3 CTs 75-150/5A of 15VA burden and accuracy Class -0.5 for metering and class 5P10 for protection. '- Common alarm annunciator with windows and buzzer, ACK, rest, test push button for all electrical faults. '- Suitable space for termination of 1 No. 3 C x 240 sq.mm XLPE cable as incoming. Outgoing:- '- 1 No. 630 Amp. electrically operated VCB with earth switch. '- 1 No. 11 KV / √3 : 110 / √3 Volt, PT CL: 0.5 and 200VA burden with 1 no.Multi function Meter with RS 485 to measure voltage, current, power factor, frequency, kW , kVA, kWH, kVAh., and protection MCB fuse at primary of PT and MCB at secondary. '- 1 No. Microprocessor based numerical relay with O/L, E/F and S/C protection. '- Breaker control switch. '- 110 V DC tripping coil. '- 110 V DC closing coil. '- Spring charging motor. '- Set of ON/OFF/TRIP indicating lamps and phase indicating lamps. '- Clear lamp for Trip Circuit healthy supply. '- Aux. relays for Anti Pumping & fault indication. '- Trip Circuit supervision relay and lock out relay.(95). '- Master Trip Circuit Relay (86). '- 2 over current IDMT microprocessor relay with instantaneous high set element range 50 – 200% '- Earth fault relay range 20 – 80% with series stabilizing resistor and PS class CT’s. '- Restricted Earth Fault relay with CT's. '- Tripping relay for each type of Electrical & Transformer Fault '- Auxiliary relays for Bucholtz, Oil ,WTI (Winding temperature indication with alarm & trip)

-

-

-

... More
- Dual core dual ratio 3 CTs 25-75/5A of 15VA burden and accuracy Class -0.5 for metering and class 5P10 for protection. '- Common alarm annunciator with windows and buzzer, ACK, rest, test push button for all transformer faults and electrical faults. '- Suitable space for termination of 1 No. 3 C x 240 sq.mm XLPE cable as incoming. '11 kV HT PANEL ( 1 I/C & 3 O/G Panel) described as above. Note: a. Potential free contact for BMS integration for ON, OFF, TRIP, AUTO, MANUAL & relays status contact. FOR all incomer & outgoing feeders. b. Suitable rating Power pack including charger, Batteries etc complete as required for complete Panel Board.

1

-

-

... More
11/0.415 KV DRY TYPE TRANSFORMERS

-

-

-

... More
Design, manufacture and supply, unloading and shifting to store, supervise the installation, testing and commissioning of 800 KVA 3 phase, 11 / 0.415 KV Indoor type Dry type transformer, percentage impedance Z= 6.25%, 0.9 pf, copper wound with Dyn11 connection and neutral brought out for earthing. The transformer shall be provided with (–) 15% and (+) 5% ON load tap changer with RTCC Panel on HT side. HT side cable termination box shall be suitable for 11 KV, 3C x 300mm2 XLPE cable and LT side terminal box shall be suitable for terminating cables / Busduct. The transformer shall be supplied all standard fitting viz dial type winding temperature indicator, all alarm contacts, thermistors for Alarm and Trip, winding temperature relay unit with Alarm and trip, Provision for remote metering for winding temperature, indications for all units, lifting lugs, earthing studs including some spare parts etc. complete in all respect as required as per specification. Transformer's 'No load losses' & 'Full Load Losses" shall be as per ECBC 2017. Note : The rate shall also include the following : (a) Supporting rigid frame work. (b) All fixing accessories such as foundation bolts, nuts and bolts etc as required. (c) Touching up all damaged paint with approved paint shade. (d) Interlocking shall be provided between transformer and VCB HT breaker panel. When transformer open respective HT breaker shall be tripped. (e) Degree of protection for transformer enclosure shall be Indoor duty. (f) Provision shall be made to be hooked up with BAS for status indication. (g) All protection relays shall be microprocessor based.

2

-

-

... More
Supply, installation, testing and commissioning of 100AH capacity 24 volts DC hermetically sealed maintenance free lead acid batteries duly charged including battery charger unit with provisions of Boost Charing, and Float charging. Suitable for 240 V, including DC DB single phase + 10% AC, 50 Hz supply as per specifications .

1

-

-

... More
Supply and fixing in position 1000 mm wide Insulating rubber matts of 11 kV grade as per electricity rules (exact length rubber mats to be worked out as per site requirement). Thickness of rubber mats shall be not less than 12 mm.

20

-

-

... More
Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass.

8

-

-

... More
Supply and installation of fire sand bucket of 9 Ltr. Cap. With bucket stand fabricated out of M.S. Sheet of 24 SWG including all accessories as required.

8

-

-

... More
Supply and fixing in position the best quality Danger Boards of approved shape and size as specified by Local Electricity Authorities written in English & Local Languages.

8

-

-

... More
Supply and fixing position the approved single line diagram framed on A3 size paper with glass frame and installed in main LT Panel Room.

4

-

-

... More
Supply of first aid box with all accessories required for 11 kV equipment with 1 pair 11 kV rubber hand gloves of approved make.

2

-

-

... More
DG Set & Accessries

-

-

-

... More
Supply, installation ,Testing and Commissioning of 1000kVA, 415 Volt, 0.8 pf & 50 Hz frequency, prime rating radiator cooled diesel generating set in acoustic enclosure along with base frame, Alternator (capable of delivering true 1000 kW output), Static Excitation System, Lube Oil System, Electronic Governor including AMF cum Synchronization module (PCC-3.3 or equivalent), alarms, Engine Control Panel comprising of suitable rating TPN ACB, protection relays, AVM pads, AVR Panel, 2 No. 12 volt DC lead acid batteries minimum 300Ah with battery charger suitable for 3 consecutive starts and black start, Residential grade silencer with bellows, terminal arrangements including space for mounting CTs for differential relays and termination box suitable for AL Busduct with all other associated equipment / work as per specifications. Manufacturer shall also conduct load test as per the specifications at manufacturers site. Euipment shall be rated for 50 degree without derating.

2

-

-

... More
Providing, fixing, installing, testing and commissioning of exhaust pipe of following dia fabricated out of 8 mm thick MS plate and all fixing accessories and hardwares. The exhaust pipes shall be insulated with 75mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium sheet as required. Exhaust pipe shall also be inclusive of required supporting structure including heat resistant paint etc complete in all respect as required for successful operation of DG set in compliance with CPCB norms. Expansion bellows shall be provided at necessary location.

-

-

-

... More
250 mm dia

20

-

-

... More
350 mm dia

30

-

-

... More
Cooling Tower

-

-

-

... More
Supply, installation, testing and commissioning of induced draft cooling tower complete in all respects. The cooling tower shall complete with fan, motor, MCC, isolator, surface and spray sections, eliminators, side casing, water basin, distribution system, filling and mechanical equipment/ components, float valve, quick fill and makeup connections, foundations/structures/ fasteners Aluminum ladder etc. as required. Motor shall be TEFC (EFF-CLASS 1) proof and suitable for 415 ±10% volts, 50 cycles, 3 phase power supply. Quoted price to include cost of thermometer (dial type) at inlet and outlet of cooling tower. (a) Cooling tower suitable for 1 No. 1000. KVA DG Set having flow rate of 1300 LPM @ 20 F delta T and 83 deg.F WB Temperature.

2

-

-

... More
Cooling Tower Water Pump

-

-

-

... More
Supply, installation, testing and commissioning of monobloc centrifugal pumps, mounted on a common base with electric motor (EFF-CLASS 1) for circulation of Engine cooling water between engine and cooling tower. The pump motor shall be suitable for 415±6% volts, 50 cycles, 3 phase power supply. The quoted price shall include cost of vibration isolation pads at each cooling tower. Each pump performance characteristics shall be as follows. Head : 120 Feet. Water Head Flow Rate : 1300 LPM for 1000 KVA DG Set. Max. Motor HP : As per Manufacturer. Cooling Tower Pumps as described above including 1 No. standby (for 1000 KVA DG set).

1

-

-

... More
Condensing Water Piping

-

-

-

... More
Providing and fixing in position the following MS class ‘C’ pipes cut to required lengths and installed with all welded joints. Providing and fixing in position the necessary fittings like elbows, tees and reducers, sockets, hot dip galvanized supports and accessories including digging and refilling earth where required for buried pipes/suspended from ceiling including Hanger, Hardware with primer & paint complete as per site requirement.

-

-

-

... More
200 mm dia MS pipes.

100

-

-

... More
125 mm dia MS pipes.

50

-

-

... More
40 mm dia MS pipes.

80

-

-

... More
25 mm dia MS pipes.

80

-

-

... More
Providing and fixing in position the following butterfly valve:

-

-

-

... More
200 mm dia MS Valves.

5

-

-

... More
125 mm dia MS Valves.

5

-

-

... More
Providing and fixing in position following Non Return valves: (a) 125 mm dia strainers.

2

-

-

... More
Providing and fixing in position the following balancing valves. (a) 125 mm dia valves

1

-

-

... More
Providing and fixing in position the following gate valves:

-

-

-

... More
40 mm dia valves.

3

-

-

... More
25 mm dia valves.

3

-

-

... More
Providing and fixing in position following ‘Y’ strainer: (a) 125 mm dia strainers.

2

-

-

... More
Providing and fixing in position the following check valves. (a) 125 mm dia valves

2

-

-

... More
Providing and fixing in position following Pot strainer: (a) 200 mm dia strainers

1

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal valves.

3

-

-

... More
Providing and fixing in position the mercury-in- glass industrial type thermometers.

4

-

-

... More
Obtaining clearance from Central Pollution Control Board (CPCB II) & State Pollution Central Authority in respect of noise level and emission level being within permissible level and obtaining clearance from Electrical Inspectorate.

1

-

-

... More
LT Panels, Distribution Boards & Rising Main

-

-

-

... More
The rates for the distribution boards apart from the Breakers and instruments shall also include the following : 1. Supporting rigid steel framework. 2. Cubicle type, 16 gauge CRCA sheet steel enclosed & Type 3b modular construction. 3. Complete with interconnections and distribution bus bars along with connector strip. 4. Proper bonding to earth as per standard. 5. Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. 6. Providing cable clamps / supports within distribution boards cable alley. 7. All MCB’s shall be of minimum 10 KA breaking capacity. 8. Distribution panels / bus ducts / rising mains shall be Powder Coated with RAL-7032 shade or as approved. 9. IP 42 Degree of protection for all indoor type and IP 55 for outdoor type of distribution panel enclosure shall be as per IS:13947-1993. 10. Current density of aluminium shall be 1 sq mm for 1.0 Amps for rated current of bus bars. 11. GI earth bus shall be provided through out the length of each board as per schematic diagram. 12. All measuring instruments (Meters) shall be of digital electronic (LED Type) of approved make. 13. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. 14. All panels shall have provision of the Pad locking of MCCB’s handles in “OFF” Position. 15. Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in main LT panel sections, etc. Only transducers shall be supplied by BAS tenderer. 16. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic.

-

-

-

... More
17. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. 18. CT’s shall be properly mounted and clamped. Connection of CT’s for measuring instrument / relays shall be done through connector / terminals. 19. Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirement. 20. All electronic meters with RS - 485 port and ACB's communication port shall be wired with shielded wire upto separate marshalling box for termination of all control wires and communication system. 21. Compliance to the technical specifications.

-

-

-

... More
LT Panels, Distribution Boards & Rising Main

-

-

-

... More
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. MAIN LT PANEL (GROUND FLOOR) Incomer - I (from Transformer - 1) (Typical for Incomer III (from Transformer - 2) & Incomer V (from Transformer - 3)) each comprising of : (a) 2000 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. The release shall have following protection: • Over current • Short Circuit (S), • Ground Fault (G), • Current Un balance • Voltage Un Balance • Under and over Voltage • Under and over frequency • Trip Circuit supervision • Harmonic Analyser Maximum demand, Fault History records, Event records facilities, LED display, % loading with adjustable setting as per specification - 1 Set

-

-

-

... More
(b) Multifunction meter for THD, V,A, KWHr, Hz, P, kVAR with CT's and RS 485 communication port - 1 Set. (c) Breaker ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Under voltage Relay with timer -1 Set. (e) Phase sequence relay - 1 Set. (f) RYB Phase indicating light protected by 2 amps MCB’s. - 1 Set. (g) Auto-manual / test selector / switch - 1 Set . (h) 24 V DC Shunt trip coil. - 1 Set. (i) Under Voltage and over voltage relay (27 & 59) with timer - 1 Set. (j) Class – B surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases - 1 Set. Incomer - II (from DG Sync Panel) (Typical for Incomer IV (from DG Sync Panel) & Incomer VI (from DG Sync Panel) each comprising of : (a) 2000 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. The release shall have following protection: • Over current • Short Circuit (S), • Ground Fault (G), • Current Un balance • Voltage Un Balance • Under and over Voltage • Under and over frequency • Trip Circuit supervision • Harmonic Analyser Maximum demand, Fault History records, Event records facilities, LED display, % loading with adjustable setting as per specification - 1 Set

-

-

-

... More
(b) Multifunction meter for THD, V,A, KWHr, Hz, P, kVAR with CT's and RS 485 communication port - 3 Set. (c) Breaker ON / OFF / TRIP indicating lights with control MCB - 3 Set. (d) Under voltage Relay with timer - 3 Set. (e) RYB Phase indicating light protected by 2 amps MCB’s. - 3 Set. (f) Auto-manual / test selector / switch - 3 Set . (g) 24 V DC Shunt trip coil. - 3 Set. (h) Under Voltage and over voltage relay (27 & 59) with timer - 3 Set. Bus Bar comprising of : (i) 2500 Amps TPN Aluminium Bus Bar throughout the panel with colour coded heat shrinkable steeve. Bus Coupler comprising of: 2000 amps 4 pole electrically operated fully drawout type air circuit breaker with ON / OFF / TRIP indicating lamps with control MCB’s, shunt trip, breaker control switch etc. - 3 Set. Outgoing comprising of : (i) 1000 amps TPN Electrically operated fully drawout type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 8 Set. (ii) 800 amps TPN Electrically operated fully drawout type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 9 Set. (iii) 630 Amps TPN MCCB with Microprocessor based releases for SC, OL and E/F protections - 7 Set. (iv) 400 Amps TPN MCCB with Microprocessor based releases for SC, OL and E/F protections - 7 Set. (v) 250 Amps TPN MCCB with Microprocessor based releases for SC, OL and E/F protections - 9 Set

-

-

-

... More
(vi) 160 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 1 Set. (vii) 125 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 5 Set. (viii) 63 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 3 Set. Notes:- (a) All Outgoing feeders shall be provided with Digital Dual Energy Meter with RS - 485 port and all meters wired at one point for BMS compatibility. (b) All Outgoing feeders shall be provided with Three phase indicating lamps protected by 2 amps SP MCBs. (c) All Outgoing feeders shall be provided with ON/OFF/TRIP Indications and shall be protected by 2 amps SP MCBs. (d) All incoming, outgoing and buscoupler breakers shall be electrically/ mechanically interlocked through PLC comprising suitable nos. digital inputs (24 VDC) and output (Relay). (e) All incoming, outgoing and buscoupler breakers shall be minimum 50 kA rating with Icu = Ics. (f) Each section of the panel shall be provided with CFL light & switch, space heater and thermostat etc. (g) 600/5, 15 VA dual ratio CT’s shall be provided for APFCR on transformer incomer. (h) Suitable danger board shall be provided. MAIN LT PANEL (GROUND FLOOR) described as above

1

-

-

... More
DG SYNCHRONIZATION PANEL (GROUND FLOOR)

-

-

-

... More
Incomer (from DG Set - 1) (Typical for Incomer II (from DG Set - 2) & Incomer III (from DG set - 3) each comprising of : (a) 2000 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. The release shall have following protection: • Over current • Short Circuit (S), • Ground Fault (G), • Under and over Voltage • Trip Circuit supervision Maximum demand, Fault History records, Event records facilities, LED display, % loading with adjustable setting as per specification - 1 Set. (b) 600 amps TP contactor for neutral isolation for each DG set. (c) Engine Generator control package relay of woodward / PCC - 3.3 of cummins at alternator / equivalent make with all accessories including remote operation from DG Sync Panel with necessary cabling etc complete as required. (d) Multifunction meter for V,A, kWH and Hz with CT's and RS 485 communication port - 1 Set. (e) Breaker ON / OFF / TRIP indicating lights with control MCB - 1 Set. (f) 24 V DC Shunt trip coil. - 1 Set. (g) Under voltage Relay with timer - 1 Set. (h) Over voltage Relay with timer - 1 Set. (i) Breaker control switch - 1 Set (j) RYB Phase indicating light protected by 2 amps MCB’s. - 1 set (k) Reverse Power Relay - 1 Set (l) Suitable rating Battery charger with voltmeter of range 0-50 volts and ammeter of range 0-50 amps for trickle and boost charging. (m) Excitor field DC voltmeter and ammeter. (n) Differential protection relay (87) with PS class CT’s on both side. ( 3 Nos. L & T SC14S )

-

-

-

... More
(o) Emergency stop push button. (p) Selector switch for Auto / Manual / Test. (q) Selector switch for engine control OFF/ON. (r) Five push buttons – start, stop, reset, test and accept. (s) Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start’. (t) 16 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as required as per specification. (u) Temperature scanner (Messi Bus/Procon). Bus Bar comprising of : 5000 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Bus Coupler comprising of 2000 amps 4 pole electrically operated fully drawout type air circuit breaker with ON / OFF / TRIP indicating lamps with control MCB’s, shunt trip, breaker control switch etc. - 2 Set. Outgoing comprising of : (i) 2000 amps TPN Electrically operated fully drawout type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 3 Set. (ii) 160 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 1 Set. Notes:- (a) All Outgoing feeders shall be provided with Digital Dual Energy Meter with RS - 485 port and all meters wired at one point for BMS compatibility (b) All Outgoing feeders shall be provided with Three phase indicating lamps protected by 2 amps SP MCBs.

-

-

-

... More
(c) All Outgoing feeders shall be provided with ON/OFF/TRIP Indications and shall be protected by 2 amps SP MCBs. (d) All incoming, outgoing and buscoupler breakers shall be electrically/ mechanically interlocked through PLC comprising suitable nos. digital inputs (24 VDC) and output (Relay). (e) All incoming, outgoing and buscoupler breakers shall be minimum 50 kA rating with Icu = Ics. (f) Each section of the panel shall be provided with CFL light & switch, space heater and thermostat etc. (g) Suitable danger board shall be provided. DG SYNCHRONIZATION PANEL (GROUND FLOOR) described as above

1

-

-

... More
MDB - 1 (LIGHTING & POWER PANEL) (GROUND FLOOR) Incomer comprising of : (a) 250 amps TPN MCCB with Microprocessor release unit for O/L, S/C & E/F protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 400 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Outgoing comprising of : (i) 63 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 60/5 amps 15 VA CTs with inbuilt selector switch - 6 Set (ii) 63 amps 4 Pole MCB - 9 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - 1 (LIGHTING & POWER PANEL) (GROUND FLOOR) described as above

1

-

-

... More
MDB - 2 (MAIN LIFT PANEL) (GROUND FLOOR ) Incomer comprising of : (a) 400 amps TPN MCCB with Microprocessor release unit along with 1 Nos. 400 amps 4P Contactor, AC3 duty, push button etc - 2 Set. (b) Multifunction meter for V, Hz & A with CT's - 2 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 2 Set. (d) Phase indicating light protected by 2 amps MCB’s - 2 Set. Bus Bar comprising of : 600 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Outgoing comprising of : (i) 125 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set (iii) 63 Amps TPN MCCB with Thermal magnetic based releases for SC, OL and external E/F protections - 6 Set. (iv) 32 amps 2 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 1 No. 30/5 amps 15 VA CTs with inbuilt selector switch - 1 Set. Notes:- (a) Both incomer shall be Electrically & Mechanically interlocked. MDB - 2 (MAIN LIFT PANEL) (GROUND FLOOR ) described as above.

1

-

-

... More
SDB - 2.1 LIFT PANEL (UPPER RIGHT SIDE) (GROUND FLOOR) Incomer comprising of : (a) 100 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set (b) Multifunction meter for V, Hz & A with CT's - 1 Set (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Outgoing comprising of : (i) 63 Amps TPN MCCB with Thermal magnetic based releases for SC, OL & external E/F protections - 7 Set. (ii) 32 amps 2 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 1 No. 30/5 amps 15 VA CTs with inbuilt selector switch - 1 Set. Notes:- All breakers shall be minimum 25 KA rating with Icu = Ics. SDB - 2.1 LIFT PANEL ( RIGHT SIDE) (GROUND FLOOR) described as above

1

-

-

... More
MDB - 2 (MAIN LIFT PANEL) (GROUND FLOOR ) Incomer comprising of : 400 amps TPN MCCB with Microprocessor release unit along with 1 Nos. 400 amps 4P Contactor, AC3 duty, push button etc - 2 Set Multifunction meter for V, Hz & A with CT's - 2 Set ON / OFF / TRIP indicating lights with control MCB - 2 Set Phase indicating light protected by 2 amps MCB’s - 2 Set. Bus Bar comprising of : (i) 600 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 125 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set (iii) 63 Amps TPN MCCB with Thermal magnetic based releases for SC, OL and external E/F protections - 6 Set. (iv) 32 amps 2 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 1 No. 30/5 amps 15 VA CTs with inbuilt selector switch - 1 Set. Notes:- Both incomer shall be Electrically & Mechanically interlocked. MDB - 2 (MAIN LIFT PANEL) (GROUND FLOOR ) described as above.

1

-

-

... More
SDB - 2.1 LIFT PANEL (UPPER RIGHT SIDE) (GROUND FLOOR) Incomer comprising of : (a) 100 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 63 Amps TPN MCCB with Thermal magnetic based releases for SC, OL & external E/F protections - 7 Set. (ii) 32 amps 2 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 1 No. 30/5 amps 15 VA CTs with inbuilt selector switch - 1 Set. Notes:- All breakers shall be minimum 25 KA rating with Icu = Ics. SDB - 2.1 LIFT PANEL ( RIGHT SIDE) (GROUND FLOOR) described as above.

1

-

-

... More
SDB - 2.2 LIFT PANEL ( LEFT SIDE) (GROUND FLOOR) Incomer comprising of : (a) 100 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 63 Amps TPN MCCB with Thermal magnetic based releases for SC, OL & external E/F protections - 7 Set. (ii) 32 amps 2 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 1 No. 30/5 amps 15 VA CTs with inbuilt selector switch - 1 Set. Notes:- (a) All breakers shall be minimum 25 KA rating with Icu = Ics. SDB - 2.2 LIFT PANEL (LEFT SIDE) (GROUND FLOOR) described as above

1

-

-

... More
MDB - 5 (FIRE FIGHTING PANEL) (FIRE PLANT ROOM) Incomer comprising of : (a) 630 amps TPN MCCB with Microprocessor release unit for O/L, S/C & E/F protection- 2 Set. (b) Multifunction meter for V, Hz & A with CT's - 2 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 2 Set. (d) Phase indicating light protected by 2 amps MCB’s - 2 Set. Bus Bar comprising of : (a) 800 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 3 Nos. 250 A TPN MCCB with Microprocessor release for 3 Nos. 125 HP motor starter along with the following for each outgoing motor starter feeder. (a) DOL Starter with 225 A contactor with 2 NO and 2 NC auxillary contacts. (b) Over load relay of rating 225 A with in built Single Phasing Preventer. (c) Ammeter of range 0-250A. (d) One set of AMBER indication with 2A SP MCB as back up, Start, Stop Push button illuminated type with remote control start, stop arrangement, Auto/ manual/ off selector switch.

-

-

-

... More
(ii) 2 Nos. 40 A TPN MCCB with Thermal magnetic release for 2 Nos. 10 HP motor starter along with the following for each outgoing motor starter feeder. (a) DOL Starter with 12 A contactor with 2 NO and 2 NC auxillary contacts. (b) Over load relay of rating 15 A with in built Single Phasing Preventer. (c) Ammeter of range 0-40A. (d) One set of AMBER indication with 2A SP MCB as back up, Start, Stop Push button illuminated type with remote control start, stop arrangement, Auto/ manual/ off selector switch. (iii) 250 Amps TPN MCCB with Microprocessor based releases for SC, OL and E/F protections - 1 Set. (iv) 40 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 1 Set. Notes:- (a) Both incomer shall be Electrically & Mechanically interlocked. MDB - 5 (FIRE FIGHTING PANEL) (FIRE PLANT ROOM) described as above

1

-

-

... More
MCC - 1 DG AUXILARY PANEL (GROUND FLOOR) Incomer comprising of : (a) 160 amps TPN MCCB with Microprocessor release unit along with 1 Nos. 150 amps 4P Contactor, AC3 duty, push button etc - 2 Set. (b) Multifunction meter for V, Hz & A with CT's - 2 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 2 Set. (d) Phase indicating light protected by 2 amps MCB’s - 2 Set. Bus Bar comprising of : 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 63 Amps TPN MCCB with Thermal magnetic based releases for SC, OL and external E/F protections - 6 Set (ii) 5 Nos. 6.3 - 10 A MPCB for (4+1 spare) Nos. 5 HP motor starter along with the following for each outgoing motor starter feeder. (a) Star Delta Starter with 3 No. 25 A contactor with 2 NO and 2 NC auxillary contacts. (b) Ammeter of range 0-10 A (c) One set of AMBER indication with 2A SP MCB as back up, Start, Stop Push button illuminated type with remote control start, stop arrangement, Auto/ manual/ off selector switch.

-

-

-

... More
(iii) 4 Nos. 9 - 13 A MPCB for (3+1 spare) Nos. 7.5 HP motor starter along with the following for each outgoing motor starter feeder. (a) Star Delta Starter with 3 No. 25 A contactor with 2 NO and 2 NC auxillary contacts. (b) Ammeter of range 0-13 A. (c) One set of AMBER indication with 2A SP MCB as back up, Start, Stop Push button illuminated type with remote control start, stop arrangement, Auto/ manual/ off selector switch. (iv) 16 amps 2 Pole MCB - 4 Set. Notes:- Both incomer shall be Electrically & Mechanically interlocked. MCC - 1 DG AUXILARY PANEL (GROUND FLOOR) described as above.

1

-

-

... More
UPS INPUT PANEL (UPS ROOM) ((GROUND FLOOR) Incomer comprising of : (a) 1000 amps 4P Electrically operated fully drawout type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 2 Set. (b) Multifunction meter for V, Hz & A with CT's - 2 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 2 Set. (d) Phase indicating light protected by 2 amps MCB’s - 2 Set. Bus Bar comprising of : 1200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : 1000 amps 4 Pole Electrically operated fully draw out type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 1 Set. 400 Amps 4 Pole MCCB with Microprocessor based releases for SC, OL and E/F protections - 6 Set. Notes:- (a) Both incomer shall be Electrically & Mechanically interlocked. UPS INPUT PANEL (UPS ROOM) ((GROUND FLOOR)) described as above.

1

-

-

... More
MDB - U1 (UPS ROOM) ((GROUND FLOOR)) Incomer comprising of : (a) 400 Amps 4 Pole MCCB with Microprocessor based releases for SC, OL and E/F protections - 3 Set. (b) 1000 amps 4 Pole Electrically operated fully draw out type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 1 Set. (c) Multifunction meter for V, Hz & A with CT's - 3 Set. (d) ON / OFF / TRIP indicating lights with control MCB - 3 Set. (e) Phase indicating light protected by 2 amps MCB’s - 3 Set.. Bus Bar comprising of : 1200 Amps TPN Copper Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 400 Amps TPN MCCB with microprocessor based releases for SC, OL and E/F protections - 4 Set. (ii) 200 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections. - 4 Set. (iii) 32 amps 2 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 1 No. 30/5 amps 15 VA CTs with inbuilt selector switch - 1 Set. (iv) 32 amps 2 Pole MCB - 1 Set. (v) 63 amps 4 Pole MCB - 1 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - U1 (UPS ROOM) ((GROUND FLOOR)) described as above

1

-

-

... More
SDB - U2 SERVER (UPS ROOM) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Copper Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 5 Set. Notes:- All breakers shall be minimum 25 kA rating with Icu = Ics. SDB - U2 SERVER (UPS ROOM) described as above

1

-

-

... More
MDB - RM1-1 (GROUND FLOOR) (LHS) Incomer comprising of : (a) 125 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 63 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 3 Set. (iii) 63 amps 4 Pole MCB - 2 Set. (iv) 40 amps 4 Pole MCB - 4 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM1-1 (GROUND FLOOR) (LHS) described as above.

1

-

-

... More
MDB - RM1-2 (FIRST FLOOR) (LHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 125 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 7 Set. (iii) 63 amps 4 Pole MCB - 3 Set. (iv) 40 amps 4 Pole MCB - 7 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM1-2 (FIRST FLOOR) (LHS) described as above.

1

-

-

... More
MDB - RM1-3 (SECOND FLOOR) (LHS) TYPICAL FOR MDB - RM1-4 (THIRD FLOOR) (LHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (a) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (b) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 4 Set. (c) 63 amps 4 Pole MCB - 2 Set (d) 40 amps 4 Pole MCB - 5 Set Notes:- (a) All breakers shall be minimum 10 kA rating with Icu = Ics. (b) MDB - RM1-3 (SECOND FLOOR) (LHS) TYPICAL FOR MDB - RM1-4 (THIRD FLOOR) (LHS) described as above

2

-

-

... More
MDB - RM1-5 (FOURTH FLOOR) (LHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 3 Set. (iii) 63 amps 4 Pole MCB - 2 Set. (iv) 40 amps 4 Pole MCB - 4 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM1-5 (FOURTH FLOOR) (LHS) described as above

1

-

-

... More
MDB - RM1-6 (FIFTH FLOOR) (LHS) Incomer comprising of : (a) 400 amps TPN MCCB with Microprocessor release unit for O/L, S/C and E/F protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set.. Bus Bar comprising of : (i) 600 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 3 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 6 Set. (iii) 63 amps 4 Pole MCB - 3 Set. (iv) 40 amps 4 Pole MCB - 4 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM1-6 (FIFTH FLOOR) (LHS) described as above

1

-

-

... More
MDB - RM1-6 (SIXTH FLOOR) (LHS) Incomer comprising of : (a) 400 amps TPN MCCB with Microprocessor release unit for O/L, S/C and E/F protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 600 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (a) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 3 Set (b) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 6 Set. (c) 63 amps 4 Pole MCB - 3 Set. (d) 40 amps 4 Pole MCB - 4 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM1-6 (FIFTH FLOOR) (LHS) described as above

1

-

-

... More
MDB - RM2-1 (GROUND FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 4 Set. (iii) 63 amps 4 Pole MCB - 3 Set (iv) 40 amps 4 Pole MCB - 4 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-1 (GROUND FLOOR) (BOTTOM RHS) described as above

1

-

-

... More
MDB - RM2-2 (FIRST FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 125 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 4 Set. (iii) 63 amps 4 Pole MCB - 3 Set. (iv) 40 amps 4 Pole MCB - 4 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-2 (FIRST FLOOR) (BOTTOM RHS) described as above.

1

-

-

... More
MDB - RM2-3 (SECOND FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 5 Set. (iii) 63 amps 4 Pole MCB - 2 Set.. (iv) 40 amps 4 Pole MCB - 6 Set. Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-3 (SECOND FLOOR) (BOTTOM RHS) described as above

1

-

-

... More
MDB - RM2-4 (THIRD FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 5 Set. (iii) 63 amps 4 Pole MCB - 3 Set. (iv) 40 amps 4 Pole MCB - 5 Set. Notes:- (a) All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-4 (THIRD FLOOR) (BOTTOM RHS) described as above

1

-

-

... More
MDB - RM2-5 (FOURTH FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 200 amps TPN MCCB with Thermal magnetic release unit for O/L and S/C protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 300 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 2 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 6 Set. (iii) 63 amps 4 Pole MCB - 2 Set. (iv) 40 amps 4 Pole MCB - 7 Set. Notes:- (a) All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-5 (FOURTH FLOOR) (BOTTOM RHS) described as above.

1

-

-

... More
MDB - RM2-6 (FIFTH FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 400 amps TPN MCCB with Microprocessor release unit for O/L, S/C and E/F protection- 1 Set. (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 600 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 3 Set. (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 8 Set. (iii) 63 amps 4 Pole MCB - 2 Set. (iv) 40 amps 4 Pole MCB - 7 Set. Notes:- (a) All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-6 (FIFTH FLOOR) (BOTTOM RHS) described as above.

2

-

-

... More
MDB - RM2-6 (SIXTH FLOOR) (BOTTOM RHS) Incomer comprising of : (a) 400 amps TPN MCCB with Microprocessor release unit for O/L, S/C and E/F protection- 1 Set (b) Multifunction meter for V, Hz & A with CT's - 1 Set. (c) ON / OFF / TRIP indicating lights with control MCB - 1 Set. (d) Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : (i) 600 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set. Outgoing comprising of : (i) 100 Amps TPN MCCB with Thermal magnetic based releases for SC and OL protections - 3 Set (ii) 40 amps 4 Pole MCB along with 1 No. Digital Dual Energy Meter including RS 485 port with 3 No. 40/5 amps 15 VA CTs with inbuilt selector switch - 8 Set. (iii) 63 amps 4 Pole MCB - 2 Set. (iv) 40 amps 4 Pole MCB - 7 Set Notes:- All breakers shall be minimum 10 kA rating with Icu = Ics. MDB - RM2-6 (SIXTH FLOOR) (BOTTOM RHS) described as above

1

-

-

... More
325 kVAR Capacitor Panel Incomer comprising of : (a) 800 amps TPN Electrically operated fully drawout type air circuit breaker with over current, short circuit & earth fault protection releases etc. - 1 Set. (b) Microprocessor APFC controller shall continuously monitor all three phases and displays various Electrical Parameters like voltage, input current, capacitive current, KVA demand, KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232C port. Controller should mounted on the front side of the panel. It shall have data logging for minimum 2 months, it shall provide output for maximum 8 stages. (c) Multifunction meter for V, Hz & A with CT's - 1 Set. (d) Breaker ON / OFF / TRIP indicating lights with control MCB - 1 Set. (e) Phase indicating light protected by 2 amps MCB’s. - 1 Set Bus Bar comprising of : (i) 1000 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Outgoing comprising of : (a) 100 kVAR Capacitor Bank - 1 Set each comprising of following: 125 Amps TPN MCCB - 1 Set 125 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set “ON” /”OFF” push buttons and indicating lamps. - 1 Set 50 kVAR, 525 volts capacitor unit as specified - 1 Set

-

-

-

... More
(b) 50 kVAR Capacitor Bank - 3 Set each comprising of following: 125 Amps TPN MCCB - 1 Set 125 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set “ON” /”OFF” push buttons and indicating lamps. - 1 Set 50 kVAR, 525 volts capacitor unit as specified - 1 Set (c) 25 kVAR Capacitor Bank - 2 Set each comprising of following: 80 Amps TPN MCCB - 1 Set 80 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set “ON” /”OFF” push buttons and indicating lamps. - 1 Set 25 kVAR, 525 volts capacitor unit as specified - 1 Set (d) 12.5 kVAR Capacitor Bank - 2 Set each comprising of following: 40 Amps TPN MCCB - 1 Set 40 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set “ON” /”OFF” push buttons and indicating lamps. - 1 Set 12.5 kVAR, 525 volts capacitor unit as specified - 1 Set Notes: (a) All incoming and outgoing breakers shall be minimum 35 kA rating with Icu = Ics. (b) All MCBs shall be minimum 10 kA breaking capacity. (c) Heavy duty exhaust fans to be provided for cooling Capacitors. (d) LED indication for number of capacitor banks ‘ON’. (e) LED indication of Power Factor lagging or leading. (f) APFC system shall comprise of following: i. Over Voltage ii. Voltage Imbalance iii. Eartxh Leakage 325 kVAR Capacitor Panel described as above

1

-

-

... More
BUS DUCT (IN SANDWICH CONSTRUCTION) Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. (a) 2000 A, Isc = 50 kA for 1 second

20

-

-

... More
RISING MAIN (IN SANDWICH CONSTRUCTION)

-

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.

-

-

-

... More
400 A, Isc = 25 kA for 1 second

20

-

-

... More
630 A, Isc = 50 kA for 1 second

20

-

-

... More
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required.

-

-

-

... More
125 A, Isc = 15 kA for 1 second

4

-

-

... More
200 A, Isc = 25 kA for 1 second

4

-

-

... More
400 A, Isc = 35 kA for 1 second

2

-

-

... More
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required .

-

-

-

... More
400 A, Isc = 30 kA for 1 second

2

-

-

... More
630 A, Isc = 50 kA for 1 second

2

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required

-

-

-

... More
125 A, 16 kA,TPMCCB

5

-

-

... More
200 A, 25 kA,TPMCCB

5

-

-

... More
250 A, 25 kA,TPMCCB

5

-

-

... More
DISTRIBUTION BOARD

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 16 way, Double door.

30

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). (a) 6 way (4 + 18), Double door.

30

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
8 way (4 + 24), Double door

20

-

-

... More
12 way (4 + 36), Double door

15

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40A

100

-

-

... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40A

50

-

-

... More
63A

20

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
25A

120

-

-

... More
40A

80

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole.

600

-

-

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.

40

-

-

... More
Supplying and fixing Cable End Boxes (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required.

40

-

-

... More
Supply, installation, testing and commissioning of 63 Amps TPN MCCB in ss enclosure of approved make.

10

-

-

... More
Submain, HT / LT Cables & Cable Tray

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire.

600

-

-

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire.

500

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire.

800

-

-

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire.

800

-

-

... More
Supplying of following 11 kV grade XLPE insulated Aluminium conductor armoured cables as per specification complete in all respect as required. (a) 3 core 240 sq. mm Al Conductor armoured cable.

300

-

-

... More
Supplying of following 1100 volt grade XLPE insulated PVC sheathed Aluminium / Copper conductor armoured/Unarmored cables as per specification complete in all respect as required.

-

-

-

... More
3.5 core 300 sq. mm Al arm.

800

-

-

... More
3.5 core 240 sq. mm Al arm.

100

-

-

... More
3.5 core 185 sq. mm Al arm.

200

-

-

... More
3.5 core 150 sq. mm Al arm.

1000

-

-

... More
3.5 core 95 sq. mm Al arm.

400

-

-

... More
3.5 core 70 sq. mm Al arm.

150

-

-

... More
3.5 core 50 sq. mm Al arm.

950

-

-

... More
4 core 35 sq. mm Al arm.

800

-

-

... More
4 core 25 sq. mm Al arm.

430

-

-

... More
4 core 16 sq.mm Cu arm.

600

-

-

... More
3 core 10 sq.mm Cu arm.

450

-

-

... More
3 core 6 sq.mm Cu arm.

250

-

-

... More
1 core 185 sq.mm Cu Unarm. FRLS

600

-

-

... More
2 core 2.5 sq.mm Cu arm. Cable including terminations

200

-

-

... More
4 core 2.5 sq.mm Cu arm.

200

-

-

... More
7 core 2.5 sq.mm Cu arm.

150

-

-

... More
12 core 2.5 sq.mm Cu arm.

250

-

-

... More
Laying of one number additional XLPE power cable of 33 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Above 120 sq. mm and upto 400 sq. mm.

300

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

3330

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1500

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

1600

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

900

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 kv grade as required. (a) 240 sq. mm.

5

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
3½ X 300 sq. mm (70 mm)

40

-

-

... More
3½ X 240 sq. mm (62mm)

10

-

-

... More
3½ X 185 sq. mm (57mm)

10

-

-

... More
3½ X 150 sq. mm (50 mm)

10

-

-

... More
3½ X 95 sq. mm (45 mm)

30

-

-

... More
3½ X 70 sq. mm (38mm)

5

-

-

... More
3½ X 50 sq. mm (35 mm)

20

-

-

... More
4 X 35 sq. mm (32mm)

100

-

-

... More
4 X 25 sq. mm (28mm)

10

-

-

... More
Supplying and making Cable end termination of the following XLPE insulated PVC sheathed Aluminium / copper conductor armoured cables of 1100 volt grade including supplying and fixing of bimettalic crimping lugs, double compression glands with earthing testing and commissioning complete in all respect as required as per site conditions.

-

-

-

... More
1 core 185 sq.mm Cu Unarm. FRLS

60

-

-

... More
4 core 16 sq.mm Cu arm.

50

-

-

... More
3 core 10 sq.mm Cu arm.

450

-

-

... More
3 core 6 sq.mm Cu arm.

300

-

-

... More
4 core 2.5 sq.mm Cu arm.

30

-

-

... More
7 core 2.5 sq.mm Cu arm.

20

-

-

... More
12 core 2.5 sq.mm Cu arm.

10

-

-

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

600

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

400

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

100

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

150

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

250

-

-

... More
900 mm width X 75 mm depth X 2.0 mm thickness

400

-

-

... More
PV Solar System

-

-

-

... More
Supply, installation,testing and commissioning of 250 KWp power with Solar Photovoltaic system including PV Modules,High efficiency Polycrystalline Solar Module, Certified by IEC 61215/61730, safety factor class II, each module of 305/250 Wp,made with 60/72 cells of busbar type, Module efficiency more than 16 %, Fill factor greate than 0.7. aluminium super structure supported on GI support, steel structure, RCC supports as per Wind pressure, foundations, string PCUs, associated power and control cabling from PV panel to PCU, PCU to Distribution Box as per drawing complete in all respect as per site requirement including cabling from inclined solar PV array to LT Panel / Distribution Board. (Including of earthing for DC as well as AC equipment or system) The system shall also include all cabling and inverter SUITABLE FOR 100 KWp SOLAR SYSTEM GRID CONNECTED INVERTER, minimum 5 location shall be considered for Inverters, House MPPT, DG set interactive,output should compatible with grid frequency. IGBT/MOSFET, Microprocessor, DSP, 415 V, 3-Phase, 50Hz +/-3%, Ambient tem -20 dec to +50Deg, Humidity 95%, Protection IP-20 for indoor and IP-65 outdoor, grid voltage tolerance -20% to +15%, No load losses lees then 1% of rated power, efficiency 93% or above, THD less then 3%, P.F more then 0.9, fully automatic, having internal protections against any fault in feeder, Built-in Export & Import meter and data logger to monitor plant, inverter desing as per IEC/BIS standard for efficiency and enviornmental tests as per IEC 61683/IS 61683 and IEC 60068-2 (1,2,14,30). MPPT as per IEC 60068-2(1,2,14,30)/BIS. Junction box should be IP-65 for outdoor and IP 55 for indoor as per IEC 529.Inverter should be grid as well as DG integrated.

1

-

-

... More
SUBHEAD - XXX : EXTERNAL LIGHTING

-

-

-

... More
Supplying,installation,testing and commissioning of 4 meter Heigh hot dip galvanised continously tapered (bolt fixing type) octagonal Single Arm Pole with top 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steel conforming to grade S 355 complete with G I base plate of size 200 mm (L) X 200 mm (B) X 12 mm thickness welded at the bottom of pole complete with 4 Nos 16 mm dia 450 mm long foundation bolts confroming to EN 8 grade, inbuilt / Vandal resistance, weathproof electrical junction box having terminal block, MCB etc mounted on bakelite sheet for looping in /looping out of cables, with flush door having locking arrangement, earthing arrangement (at atleast 0.5 m height) and mounted on RCC foundation of size 500 mm x 500 mm x 1600 mm in ground and 200 mm above ground level with foundation bolt duly embeded before casting and supply and embedding of suitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as required.

30

-

-

... More
Supplying,installation,testing and commissioning of 4 meter Heigh hot dip galvanised continously tapered (bolt fixing type) octagonal Double Arm Pole with top 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steel conforming to grade S 355 complete with G I base plate of size 200 mm (L) X 200 mm (B) X 12 mm thickness welded at the bottom of pole complete with 4 Nos 16 mm dia 450 mm long foundation bolts confroming to EN 8 grade, inbuilt / Vandal resistance, weathproof electrical junction box having terminal block, MCB etc mounted on bakelite sheet for looping in /looping out of cables, with flush door having locking arrangement, earthing arrangement (at atleast 0.5 m height) and mounted on RCC foundation of size 500 mm x 500 mm x 1600 mm in ground and 200 mm above ground level with foundation bolt duly embeded before casting and supply and embedding of suitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as required.

3

-

-

... More
Supplying,installation,testing and commissioning of 3 meter Heigh hot dip galvanised continously tapered (bolt fixing type) octagonal Pole with top 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steel conforming to grade S 355 complete with G I base plate of size 200 mm (L) X 200 mm (B) X 12 mm thickness welded at the bottom of pole complete with 4 Nos 16 mm dia 450 mm long foundation bolts confroming to EN 8 grade, inbuilt / Vandal resistance, weathproof electrical junction box having terminal block, MCB etc mounted on bakelite sheet for looping in /looping out of cables, with flush door having locking arrangement, earthing arrangement (at atleast 0.5 m height) and mounted on RCC foundation of size 500 mm x 500 mm x 1600 mm in ground and 200 mm above ground level with foundation bolt duly embeded before casting and supply and embedding of suitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as reqd.

9

-

-

... More
Supply Installation , Testing & Commissioning of IP65 LED 7W LED spike Light with Integrated COB lamp with aluminium housing and toughened glass diffuser , colour Temp 3000K. Philips Cat no. Garden Spike 7W -31385

50

-

-

... More
Supply Installation , Testing & Commissioning of 8W LED Bollard with IP65 Protection with extruded aluminium housing with Poly carbonate cover with 3000K Color temperature 600mm height BCP150 LED150/WW PSU 220-240V

4

-

-

... More
Supply Installation , Testing & Commissioning of 36W LED Street Light with 3600lm Die cast aluminium housing with secondary lens optics with THD10% and PF0.95 with IP66 protection Philips BRP409 LED CW 036 MR FG S1 PSU GR.

3

-

-

... More
Supply Installation , Testing & Commissioning of 27W LED Post top fixture with system lumen output 3350 lumens with Die Cast housing with IP65 Protection in 3000K CCT. Philips BGP161 LED2500/WW PSU 220-240V 7043 IN

9

-

-

... More
Supply Installation , Testing & Commissioning of 35W LED Post Luminaire with system lumens 5200lm with Die cast housing and street Light optics with IP66 and IK08 protection.Philips BGP400 LED35 L CW MR FG S1

20

-

-

... More
Supply Installation , Testing & Commissioning of 7W LED Step light wall recessed with system lumen output 80lm with dies cast aluminium housing in 5700K CCT and Heat resistant frosted glass with frame grillcover. Philips G150 LED50/WW PSU 220-240V IP67 7043

150

-

-

... More
Supply Installation , Testing & Commissioning of 60W LED Flood light with system lumen output100lm with dies cast aluminium housing in 5700K CCT and Heat resistant frosted glass with frame grillcover. Wipro Cat no. LF19-711-060-57-XX

20

-

-

... More
Feeder Pillar (For External Landscape lighting) IP 55 for outdoor Protection Incomer:- (a) 63 Amps 4 pole MCB with 1 Nos. of 63 Amp four pole Contactor, AC-1duty with Timer, ON/OFF indication lamps, A/M switch. as incomer . Bus Bars (a) 100 Amps TPN Aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set. Outgoing;- (i) 16 Nos of 10 - 32 Amp FP MCB of minimum 10 KA breaking capacity. (ii) 3 Nos of 16 Amp DP MCB of minimum 10 KA breaking capacity without timer control. (iii) Feeder Pillar for external / landscape lighting as described above.

3

-

-

... More
Supplying of following 1100 volt grade XLPE insulated PVC sheathed Aluminium / Copper conductor armoured/Unarmored cables as per specification complete in all respect as required. (a) 4 core 6 sq.mm Cu arm.

5000

-

-

... More
Supplying and making Cable end termination of the following XLPE insulated PVC sheathed Aluminium / copper conductor armoured cables of 1100 volt grade including supplying and fixing of bimettalic crimping lugs, double compression glands with earthing testing and commissioning complete in all respect as required as per site conditions. (a) 4 core 6 sq.mm Cu arm.

400

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Upto 35 sq. mm

5000

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Upto 35 sq. mm

5000

-

-

... More
Supply and installation of following RCC (NP-2 class) Hume pipe for underground laying of cables under paved/soil/rock areas with all necessary material and at required depth upto 1 mtr including excavation, back filling with excavated material, providing pipe protection layer all around pipe (75 mm thick cement concrete all around pipe 1:3:6 (1 cement, 3 coarse sand and 6 crushed stone aggregate), cable route marker, brick etc, ramming and making the surface finish good in all respect as required. (a) 100 mm ID.

150

-

-

... More
SUBHEAD-XXXI: WATERBODY & FOUNDATION

-

-

-

... More
Providing and fixing self priming pump with built - in strainer , ABS Body, with noriyl impeler complete in all respect to deliver the following duty parameters. Discharge per pump : 1000 LPM App. Head : 12.0 Metre

2

-

-

... More
Chemical Dosing system for ph and Chlorine , Electromagnetic dosing pump in Polypropylene , IP-65 protection , Maximum flow 6.0 lph at 3 bar , 0-100% manual flow adjustment.

2

-

-

... More
Supply , Erection , Testing and Commissioning of 200 x 200 mm in ABS Main Drain Gratings having Velocity - 0.5 m/sec. through grill , material of construction , frame and grill, suction grill size as per drawing , fitting , fixing , required for the work complete as per direction of architect.

4

-

-

... More
Supply, Erection , testing and comissioning of Vaccum Nozzel, Material of construction - ABS Plastic , Outside connection - 2.5" BSP (M) including all accessories , fitting , fixing , required for the work complete as per direction of Architect.

8

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
15 mm nominal dia Pipes.

30

-

-

... More
20 mm nominal dia Pipes.

40

-

-

... More
25 mm nominal dia Pipes.

30

-

-

... More
32 mm nominal dia Pipes.

30

-

-

... More
40 mm nominal dia Pipes.

30

-

-

... More
50 mm nominal dia Pipes.

30

-

-

... More
65 mm nominal dia Pipes.

20

-

-

... More
80 mm nominal dia Pipes.

30

-

-

... More
100 mm nominal dia Pipes.

50

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
25 mm nominal bore

2

-

-

... More
20 mm nominal bore

2

-

-

... More
32 mm nominal bore.

2

-

-

... More
40 mm nominal bore

2

-

-

... More
50 mm nominal bore

2

-

-

... More
65 mm nominal bore

2

-

-

... More
80 mm nominal bore

2

-

-

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (a) 100 mm diameter. Class I

2

-

-

... More
Supply , Erection , Testing and Commissioning of Brass Column Fire Works fountain nozzle equired for the work complete as per direction of architect.

20

-

-

... More
Supply, installation, testing and commissioning of dust, damp and vermin proof, free floor standing factory built sheet steel enclosed non draw out modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections & indications and mounted with the following including all inter connection etc. (Including earthing). One No. 63 amps TP incoming MCCB complete with the following: 1 No. 0-500 volts 96x96 sq. mm ammeter with selector switch and fuses. (1 set). 1 No. 0-100 amps 96x96sq.mm ammeter with 60/5 amps ratio CT's and selector switch. Over voltage and under voltage tripping machanism for persistent voltage fluctations of more than ±10% of the rated voltage for more than 5 minutes. (1set). Phase indicating lamps with toggle switches. Indication lamps for ON/OFF/TRIP status of motors. Aluminium bus bar of 100 amps for three phase and neutral. Outgoing Feeders/Starters. 63 amps TPN MCB with built-in SPP each suitable for 10 HP tubewell pumps panel (1 Set). Rotary manual/auto/off switch. (4 Nos.) Spares 16 amps TPN MCB - 2 Nos. 32 amps TPN MCB - 2 Nos. Note : All switch gear/panels shall be suitable for 10 KA rating. All outgoing will have 96 sq. mm size ammeter and CT. All starter will have spare 10 amps 230 V coil auxiliary contractor for building Automation system.

-

-

-

... More
All starter units for pumps to be provided with 3 level liquid level contractor. Lamps. All pumps to be provided with duty selector switch. All pumps to be provided with sequence timer 220/440 V AC/DC and alternate working of pumps between 6 to 8 hours or alternate use of pumps after one service in sequence. All pumps to be provided with over load relay. All starter to be provided with single phase preventor. Necessary cable alleys for space switches, level controller internal wiring and copper earthing of all equipment shall also be included. All switch gears/control gears shall be motor duty rating.

2

-

-

... More
SUBHEAD - XXXII : ARBORICULTURE

-

-

-

... More
TREE PLANTATION

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : (a) Holes 90 cm dia, and 90 cm deep

180

-

-

... More
Providing and Stacking of Mimusops Elengi (Maulsri) of height 180-195 cm, well developed with stem in big size HDPE bag as per the direction of Officer-in-Charge.

30

-

-

... More
Providing and Stacking of Plumeria alba dwarf of height 90-105 cm with 3-4 branches and thick stem in big size HDPE bags as per the direction of Officer-in-Charge.

30

-

-

... More
Providing and Stacking of Saraca indica (Sita Ashok) of height 105-120 cm, in big poly bags of size 25.cm as per the direction of Officer-in-Charge.

30

-

-

... More
Providing and Stacking of Ficus Panda of height 90-105 cm with 10-12 branches and healthy foliage,well formed in cement pots of size 30cm as per the direction of Officer-in-Charge.

30

-

-

... More
Providing and Stacking of Delonix regia (Gulmohar) of height 150-165 cm, in big poly bags of size 25 cm as per the direction of Officer-in-Charge.

30

-

-

... More
Providing and displaying of Areca Palm Plant, having height 1.20m to 1.50m with 5 to 6 suckers, well developed, fresh and healthy with lush green foliage, in 25 cm size of Earthen pot/Plastic pot & as per the direction of Officer-in-Charge.

30

-

-

... More
Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 itres per hole in two time or more application to get the trees free from termite infection chemicals used Chloropyriphos 20% EC in the ratio of 1% concentration and as per direction of Officer-in-charge.

180

-

-

... More
Plantation of Trees at site i/c watering and removal of unserveiceable material's as per direction of Officer-in-charge (excluding cast of plant & water). (a) Trees Plant

180

-

-

... More
SHRUB / HEDGE / CREEPER

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : (a) Holes 60 cm dia, and 60 cm deep.

600

-

-

... More
Providing and Stacking of Allamanda cathartica of height 30 cm to 45 cm, in 20 cm size of Earthen pots / Plastic pots & as per the direction of Officer-in-Charge.

100

-

-

... More
Providing and stacking of Bignonia venusta (Golden shower) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara, Mohan, Scarlet Queen, Variegated, Glabra Formosa, Peruviana, Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Adenium Obesum grafted well developed with fresh & healthy 30 to 60 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

100

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) (a) Shurbs/Hedges/Creeper Plant

600

-

-

... More
LAWN

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

300

-

-

... More
Rough dressing the trenched ground including breaking clods.

600

-

-

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

600

-

-

... More
Fine dressing of the ground.

600

-

-

... More
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.

600

-

-

... More
Providing & laying Bermuda Dibbling grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge.

600

-

-

... More
Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge

100

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).

50

-

-

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).

50

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S designation 20 mm

50

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thicknes as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

100

-

-

... More
ORNAMENTAL PLANTS (POTTED PLANTS)

-

-

-

... More
Providing and Displaying Bird of paradise / Ficus nuda / Ficus resnold / Furcaria Variegated / plant well developed with fresh & healthy 90 to 120 cm ht in 45 cm Earthen Pot / Plastic Pot as per direction of the Officer-in-charge.

100

-

-

... More
MAINTENANCE

-

-

-

... More
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, edge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide, lawn mover and brush cutter with fuel & other T & P material/ articles shall be provided by the contractor.) i) Permanent office accommodation per Sqm (as per yard stick 1 Mali = 1.25 Acre) ii) Shurbs / Hedges / Creeper : 1949 sqm iii) Trees area : 150 sqm iv) Lawn area : 3000 sqm Total : 5099 sqm

5000

-

-

... More
Providing and laying pebble stone flooring comprising of 100% natural pebbles, tumbled smooth , bonded to a sturdy mesh backing 12" x 12" . The sub surface shall be made smooth before laying and pebbles laid on thinset sanded grout with grey/ white cement, poured seamlessly over concrete , interstices filled with small pebbles etc. all complete as specified and as directed by the Engineer-in-Charge.

50

-

-

... More
PIPES & PUMPING UNIT

-

-

-

... More
Pipes Work:Supply, laying & commissioning in position PVC pipe conforming to IS:4985:2000 and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. trenching, refilling & testing of joints complete as per direction of Engineer in Charge - (Finolex/Supreme make).

-

-

-

... More
PVC pipe 75mm-6 kg/cm²

75

-

-

... More
PVC pipe 63mm-6 kg/cm²

75

-

-

... More
PVC pipe 50mm-6 kg/cm²

75

-

-

... More
PVC pipe 40mm-6 kg/cm²

75

-

-

... More
Supply, Fixing & commissioning of Monobloc or openwell submersible pumpset of having discharge and head of design flow. (TEXMO / KIRLOSKER/Wilo) Duty of Pump : 5.6lps Pressure Head Range =40 Mtr No. of Pumps : 1 Working + 0 Standby

1

-

-

... More
Supply, Fixing & commissioning of control panel suitable for pumpset having panel box made of CRCA sheet of 2 mm thickness and fixed along with following accessories DOL starter (L&T make),start / stop push buttons (L&T make), Ammeter (AE make), Single phase preventor (Minilec make), Voltmeter (AE make) , Indicating lamps (L & T make), MCB (L & T make),

1

-

-

... More
Supply, Fixing & commissioning of Suction ,Delivery & Header Pipe of size suitable for the pump flow sch 40/80 or PVC 10Ksc (Finolex/Supreme)

1

-

-

... More
Supply, Fixing & commissioning of control Valve, Butterfly Valve in mainline for bypass and flow diversion of approved quality with pressure rating of PN 10 (VARIOS / AQVASTAR)

1

-

-

... More
Supply, Fixing & commissioning of Non Return Valve to prevent back flow have flap type or spring type with pressure rating of PN 10 (VARIOS / AQVASTAR)

1

-

-

... More
Supply, Fixing & commissioning of Pressure release valve 2" with pressure setting from 0 to 7 Bar. (VARIOS / AQVASTAR)

1

-

-

... More
Supplying and Stacking Urea at site including royalty and carriage upto 8 km complete

250

-

-

... More
Providing and supplying Welspun Grass 35mm thick, Test Method : ASTM E 648 0.45 (Class I) , complete as per drawing, specifications of the architect. The carpet will be installed with standard SR 998 / SR505 / Mapei adhesives. The flooring to be installed as per the manufacturers specification and to be installed by its authorized agency or as Approved, Carpet has minimum 5 years warranty from Manufacturer for any manufacturing defects. Grass to be Made in India.Rates inclusive of installation.

1000

-

-

... More
NOTE :- DSR RATES WILL BE ALLOWED FOR ITEMS THAT ARE NOT COVERED IN BOQ AND SAME IS REQUIRED TO BE INCORPORATED IN THE WORK AS PER SITE CONDITIONS AS DIRECTED BY ENGINEER-IN-CHARGE.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.