Dakshinanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Nov 2024
Closing Soon30 Nov 2024
Tender Amount₹ 5,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Carriage of following from 132 KV Taj Store Center Agra/JE Store/Pit sit to realted 33/11 KV Substations and to site of work i.e. pit point through the Kacha and Pakka road by using manual labour or tractor/Hydra as per site requirment including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) 11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps and other required for LT/11KV/33KV line material, if any.

25

-

-

... More
Removal of existing ACSR Weasel conductor from damaged line/Pole including opening of jumpers etc as per requirement of site and as per direction of Supervising Engineer.

3200

-

-

... More
Removal of existing ACSR Dog/Raccon conductor from damaged line/Pole including opening of jumpers etc as per requirement of site and as per direction of Supervising Engineer.

750

-

-

... More
Removal of existing Arial Bunch Conductor 3x50/95/120 sq mm from damaged line/Pole including opening of jumpers etc as per requirement of site and as per direction of Supervising Engineer.

450

-

-

... More
Replacement of 8.5 Mtrs. Long damaged PCC pole by opening of all existing accessories from damaged pole properly and removal of damaged pole and erect the new pole at same place including fixing of all existing accessories on the new pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. required for proper completion of work.

100

-

-

... More
Replacement of 9 Mtrs. Long damaged PCC pole by opening of all existing accessories from damaged pole properly and removal of damaged pole and erect the new pole at same place including fixing of all existing accessories on the new pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. required for proper completion of work.

5

-

-

... More
Replacement of 11/13 Mtrs. Long damaged ST pole by opening of all existing accessories from damaged pole properly and removal of damaged pole and erect the new pole at same place including fixing of all existing accessories on the new pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. required for proper completion of work.

3

-

-

... More
Replacement of 8.5 Mtrs. Long damaged PCC Double Pole by opening of all existing Accessories, T/F from damaged Double pole properly and removal of damaged poles and Erection of New Double Pole at same place including fixing of all existing accessories on the New Double Pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. required for proper completion of work.

15

-

-

... More
Replacement of 11/13 Mtrs. Long damaged ST Double Pole by opening of all existing Accessories, T/F from damaged Double pole properly and removal of damaged poles and Erection of New Double Pole at same place including fixing of all existing accessories on the New Double Pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. required for proper completion of work.

1

-

-

... More
Mounting of 16/25 KVA Transformer on the Single Pole/Double pole structures and connections thereof.

8

-

-

... More
Mounting of 63 KVA Transformer on the Double pole structures and connections thereof.

7

-

-

... More
Mounting of 100 KVA Transformer on the Double pole structures and connections thereof.

5

-

-

... More
Installation of stay set with grouting and Nuzzling etc. as per RESPO drawing /norms along with all routine material to be used for such works.

25

-

-

... More
Earthing of poles by fixing earth rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work.

25

-

-

... More
Laying, sagging, stringing, jumpering and binding etc. of new & old ACSR Weasel conductor in 11 KV/ LT lines as per RESPO manual as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work

4000

-

-

... More
Laying, sagging, stringing, jumpering and binding etc. of new & old ACSR Dog/Raccon Conductor in 11 KV/33KV lines as per RESPO manual as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work

900

-

-

... More
Laying, sagging, stringing, jumpering and binding etc. of new & old Arial Bunch Conductor 3x50/95/120 sq mm. in LT lines as per RESPO manual as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work

400

-

-

... More
Replacement of damaged 33KV/11 KV X-Arm along with Nut & Bolt and all other related accesoories.

50

-

-

... More
Replacement of damaged 33KV/11 KV Disc Insulator with fitting along with Nut & Bolt and all other related accesoories.

50

-

-

... More
Replacement of damaged 33KV/11 KV/LT Pin Insulator with Pin with fitting along with Nut & Bolt and all other related accesoories.

50

-

-

... More
Replacement of damaged 33KV/11 KV/LT F" Clamp/X-Arm Clamp/D.P.Clamp/L.T. Pin Clamp with fitting along with Nut & Bolt and all other related accesoories.

50

-

-

... More
Guarding/Reguarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. It includes the cost o f labour T&P carriage etc required for proper completion.

10

-

-

... More
Guarding/Reguarding of 33 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. It includes the cost o f labour T&P carriage etc required for proper completion.

8

-

-

... More
Chopping of Tree branches to Clear the line route to give horizontal and vertical clearance to the line including cost of labour T&P etc.

150

-

-

... More
Re- sagging and stringing of ACSR Weasel conductor in 11KV/ /LT line as per direction of supervising engineer including the cost of arrangement of labour,T&P, carrier etc. required for proper completion of work.

2500

-

-

... More
ACSR Dog/Racoon Conductor.

1000

-

-

... More
50/95/120 sqmm ABC

700

-

-

... More
Re- sagging and stringing of existing conductor in 33 KV line as per direction of supervising engineer including the cost of arrangement of labour,T&P, carrier etc. required for proper completion of work A) ACSR Dog/Racoon Conductor.

850

-

-

... More
Re-nuzzling of old stay set by opening old binding for better straightening of pole and re-sag the existing conductor of H.T/L.T line properly as per direction of supervising engineer.

20

-

-

... More
Straightening of 8.5/9 Mtr. Long PCC/ST/Rail Pole tilted pole at various places by straightening of pole including the cost of labour ,T&P charges required for proper completion of work.

60

-

-

... More
Carriage of 11/13 Mtrs. long Damaged ST pole from Pit Site to J.E. Store/Store Center Agra through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.)

20

-

-

... More
Numbering of Replaced poles by Yellow enamel paint as per direction of supervising Engineer. (Concerning material shall be provided by the contractor at his own cost)

140

-

-

... More
Vediography of All Work's site Shall be made by the contractor of concerning site before starting the work and after the completion of work & the copy of vediography shall be submitted by the contractor at the time of Measuremnt/Payment.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.