Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Feb 2023
Closing Date15 Feb 2023
Tender Amount₹ 4,11,42,000
Costs
EMD
₹ 4,12,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_DVVNL_768125_2Bid Award Id
ViewTender No
EDCBNDA-30/2022-23Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
11/0.4 KV 25 KVA T/F
2
-
-
11/0.4 KV 63 KVA T/F
7
-
-
11/0.4 KV 100 KVA T/F
22
-
-
11/0.4 KV 250 KVA T/F
5
-
-
11/0.4 KV 400 KVA T/F
7
-
-
ACSR Weasel Conductor
1430
-
-
ACSR Dog Conductor
5460
-
-
ACSR Rabbit Conductor
2640
-
-
ACSR Raccon Conductor
5
-
-
Cable LT ABC (3x120+1x95+1x16 Sq.mm.)
11518
-
-
Cable LT ABC (3x95+1x70+1x16 Sq.mm.)
10104
-
-
Cable LT ABC (3x50+1x25+1x16 Sq.mm.)
7295
-
-
Stone Pad
427
-
-
11 KV V-Type Steel X-arm (65x65x6 mm)
66
-
-
Cross-arm holding clamp with N & B
66
-
-
F-Bracket for fitting top insulator
73
-
-
11 KV Pin Insulator with pin
405
-
-
11 KV Disc Insulator with fitting
258
-
-
MS Top Channel (125x65x2240 mm)
77
-
-
MS Dropper Channel (100x50x2028 mm)
55
-
-
MS Angle 75x75x6x2028 mm. with clamp & N/B (T/F Base)
45
-
-
M.S. Angle 65x65x6mm 4300mm with 4 clamp bracing
10
-
-
MS T-Off Channel (125x65x1300 mm)
61
-
-
Clamp for Channels
451
-
-
11 KV Fuse Set
38
-
-
Suspension Clamp
726
-
-
Dead End Clamp
285
-
-
Piercing clamp
891
-
-
Eye Hook Insulated with bolt.
349
-
-
LT Distribution Box 3-Phase
459
-
-
LT D.B. Clamp for 3 Phase
292
-
-
LT Distribution Box 1-Phase
261
-
-
LT D.B. Clamp for 1 Phase
287
-
-
Earthing Rod Complete (MS earthing rod of 20x2500 mm, 6 SWG earthing wire etc.)
921
-
-
Stay Complete (Stay rod 16x1800 mm, Stay wire 5 Kg., Stay clamp, Bolt & Nut with Grounting)
358
-
-
Danger Board with clamp & Nut/Bolt
27
-
-
Gaurding Angle with Clamp & nut-bolt
16
-
-
GI Wire 6 SWG
200
-
-
GI barbed Wire
250
-
-
LT Clamp with N & B
722
-
-
PG Clamp
30
-
-
Nut, Bolt & Washer of suitable sizes
150
-
-
SF Cluster for Cable Jointing
56
-
-
LT PVC Cable 4x16 Sq. mm.
175
-
-
LT PVC Cable 3.5x150/70 Sq.mm.
181
-
-
LT PVC Cable Al. 1x240 Sq.mm.
165
-
-
LT PVC Cable Al. 1x400 Sq.mm.
350
-
-
Al. Lugs for 100 KVA T/F
88
-
-
Al. Lugs for 250 KVA T/F
4
-
-
Al. Lugs for 400 KVA T/F
240
-
-
Alluminium Paint
24
-
-
Red Oxide Paint
24
-
-
Erection of single support structure on 11 Mtr. ST Pole, including complete HT/LT fittings with fixing of all accessories, includes also the work of safe cartage of poles with related accessories to work site as per direction of Engineer incharge/RESSPO manual.
45
-
-
Erection of double pole structure on 11 Mtr. ST Pole, including complete HT/LT fittings with fixing of all accessories, includes also the work of safe cartage of poles with related accessories to work site as per direction of Engineer incharge/RESSPO manual.
43
-
-
Erection of single support structure on 8.5 Mtr. PCC Pole, including complete HT/LT fittings with fixing of all accessories, includes also the work of safe cartage of poles with related accessories to work site as per direction of Engineer incharge/RESSPO manual.
742
-
-
Erection of double pole structure on 8.5 Mtr. PCC Pole, including complete HT/LT fittings with fixing of all accessories, includes also the work of safe cartage of poles with related accessories to work site as per direction of Engineer incharge/RESSPO manual.
6
-
-
Concreting/Grouting of erected 11 Mtr. long STP Poles as single pole structure as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. (arrangement of grouting material by firm).
45
-
-
Concreting/Grouting of erected 11 Mtr. long STP Poles as double pole structure as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. (arrangement of grouting material by firm).
43
-
-
Concreting/Grouting of erected 8.5 Mtr. long PCC Poles as single pole structure as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. (arrangement of grouting material by firm).
742
-
-
Concreting/Grouting of erected 8.5 Mtr. long PCC Poles as double pole structure as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. (arrangement of grouting material by firm).
6
-
-
Construction of new 11/0.4 kV, 100/250/400 KVA Transformer plinth of size 4x4x5 ft. above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly. After that a retaining wall of 9” width by first class brick in ratio 1:5 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. After this brick ballast shall be provided up to 6” from the earth level and proper rammering shall be done. One No. Jail of 12 mm MS tore shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement, sand and stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervising Engineer.
3
-
-
Erection/Installation of 25 KVA Distribution Transformer on the newly erected double pole structure with fitting of all accessories, earthing & all connections both ends by suitable size cable, including the work of safe cartage of T/F, related accessories, cable etc.
2
-
-
Erection/Installation of 63 KVA Distribution Transformer on the existing/newly erected double pole structure with fitting of all accessories, earthing & all connections both ends by suitable size cable, including the work of safe cartage of T/F, related accessories, cable etc.
7
-
-
Erection/Installation of 100 KVA Distribution Transformer on the newly erected double pole structure/plinth with fitting of all accessories, earthing & all connections both ends by suitable size cable, including the work of safe cartage of T/F, related accessories, cable etc.
22
-
-
Erection/Installation of 250 KVA Distribution Transformer on the newly erected double pole structure/plinth with fitting of all accessories, earthing & all connections both ends by suitable size cable, including the work of safe cartage of T/F, related accessories, cable etc.
5
-
-
Erection/Installation of 400 KVA Distribution Transformer on the newly erected double pole structure/plinth with fitting of all accessories, earthing & all connections both ends by suitable size cable, including the work of safe cartage of T/F, related accessories, cable etc.
7
-
-
Demounting of 250 KVA T/F, including the work of safe carriage of the same T/F from work site to departmental store with loading & unloading.
4
-
-
Demounting of 100 KVA T/F, including the work of safe carriage of the same T/F from work site to departmental store with loading & unloading.
1
-
-
Demounting of 25 KVA T/F, including the work of safe carriage of the same T/F from work site to departmental store with loading & unloading.
1
-
-
Erection of 11 KV Line with laying, sagging, stringing, binding and jumpering of new ACSR Weasel/Dog/Rabbit/Raccon Conductor on 11.0 Mtr. Long STP poles with fitting of all accessories as per direction of supervising engineer/RESSPO manual. Includes the work of safe cartage of conductor & related fitting accessories. Above conductor also used in jumpering.
3.35
-
-
Erection of 11 KV Line with laying, sagging, stringing, binding and jumpering of new ACSR Weasel/Dog/Rabbit/Raccon Conductor on 8.5 Mtr. Long PCC poles with fitting of all accessories as per direction of supervising engineer/RESSPO manual. Includes the work of safe cartage of conductor & related fitting accessories. Above conductor also used in jumpering.
6.19
-
-
Erection of LT Line with laying, stringing, binding and sagging etc. of cable LT ABC (3x120+1x95+1x16 Sq.mm.) on the newly erected poles as per direction of supervising engineer/RESSPO manual. Includes the work of safe cartage of conductor & related fitting accessories.
11.52
-
-
Erection of LT Line with laying, stringing, binding and sagging etc. of cable LT ABC (3x95+1x70+1x16 Sq.mm.) on the newly erected poles as per direction of supervising engineer/RESSPO manual. Includes the work of safe cartage of conductor & related fitting accessories.
10.1
-
-
Erection of LT Line with laying, stringing, binding and sagging etc. of cable LT ABC (3x50+1x25+1x16 Sq.mm.) on the newly erected poles as per direction of supervising engineer/RESSPO manual. Includes the work of safe cartage of conductor & related fitting accessories.
7.3
-
-
Reconductoring of 33 KV Line on ACSR Dog Conductor, including the work of binding.
10
-
-
Reconductoring of 11 KV Line on ACSR Weasel Conductor, including the work of binding.
15
-
-
Reconductoring of 11 KV Line on ACSR Dog Conductor, including the work of binding.
6
-
-
Reconductoring of LT Line on ABC Conductor, including the work of binding.
13
-
-