Dakshinanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender

Works
Eprocure
Opening Date7 Apr 2024
Closing Date12 Apr 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Edch-170/2023-24

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps and other required line material, if any.

20

-

-

... More
Safe Carriage of following from Electricty Store center Hathras to Pit Site of Work through the Kacha and Pakka road loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-70 Kms.)

-

-

-

... More
16 KVA T/F

2

-

-

... More
25 KVA T/F, 63 KVA T/F, 100 KVA T/F

2

-

-

... More
Replacement of damaged 8.5 Mtr. long PCC pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/LT accessories from the existing / damaged pole and errection of single new pole including Fixing of all accessories.

14

-

-

... More
Replacement of damaged 9/11 Mtr. Long ST pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/33 KV accessories from the existing / damaged pole and errection of single new STP pole including Fixing of all accessories.

5

-

-

... More
Replacement of damaged 8.5 meter long of Double PCC Pole (first opening of all accessories & then removing damaged poles),under Errection D/P including fixing of Disc Insulators with fitting and other LT/11 KV accessories as per RESPO manual and as per direction of supervising engineer, The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast) including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site

4

-

-

... More
Replacement of damaged Double pole on 9/11 meter long of Double ST Pole (first opening of all accessories & then removing damaged poles), re-erecting D/P including fixing of Disc Insulators with fitting and other 11 KV/ 33KV accessories as per RESPO manual and as per direction of supervising engineer. The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast) including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site

1

-

-

... More
Straightening of tilted single PCC Poles in the existing lines as per direction of supervising engineer.

22

-

-

... More
Straightening of tilted single ST Poles in the existing lines as per direction of supervising engineer.

10

-

-

... More
Straightening of tilted Double Poles in the existing lines as per direction of supervising engineer.

5

-

-

... More
Replacement of following damaged accessories in 11 KV /LT line -

-

-

-

... More
11 KV X-Arms, 11 KV Pin Insulators with Pin & Nut & Bolt , 'F' Clamp

25

-

-

... More
11 KV Disc Insulator With Fiting

25

-

-

... More
Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer with Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.

15

-

-

... More
Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.

15

-

-

... More
Laying, sagging and stringing and Nozzling / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.

-

-

-

... More
ACSR Weasel conductor

2750

-

-

... More
ACSR Dog / Racoon Conductor

400

-

-

... More
50/95/120 sqmm. Areal Bunch Conductor

400

-

-

... More
Re- sagging and stringing of existing following conductor in HT /LT line as per direction of supervising engineer.

-

-

-

... More
ACSR Weasel conductor

2000

-

-

... More
50/95/120 sqmm. Areal Bunch Conductor

520

-

-

... More
ACSR Dog Conductor

950

-

-

... More
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer

50

-

-

... More
Safe Installation of following New/Repaired cousted T/F on newly constructed double pole in proper alignment direction & making all HT/LT connection.

-

-

-

... More
16 KVA T/F

2

-

-

... More
25 KVA T/F, 63 KVA T/F, 100 KVA T/F

2

-

-

... More
Re Guarding / Guarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr.

75

-

-

... More
Digging of proper size of pit for following work of damaged steel support with the provision of temporary support :- Then reinforcement of steel support by welding of 04 Nos. 2 feet long M.S. angle iron of 50x50x6 mm. at equal distance around each pole & also welding of these angle iron with each other by providing M.S. flat of size 35x6 mm. in round. After this construction of round plinth of pole will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm. dia & 600 mm height (300 mm. under the ground + 300 mm. the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth. The rate will include all cost of material, labour and T&P etc. for completion of the above work which will be provided by the contractor at his own cost.

25

-

-

... More
Construction of round plinth around the S.T. Poles / RS Joists / Rails will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm. dia & 600 mm height (300 mm. under the ground + 300 mm. the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth. The rate will include all cost of material, labour and T&P etc. for completion of the above work which will be provided by the contractor at his own cost.

25

-

-

... More
Video graphy before & after works and GIS Cordinate

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.