If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date25 Jan 2024
Closing DateCancelled
Tender Amount₹ 1,61,60,000
Costs
EMD
₹ 1,75,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_880038_1Tender No
EUDCA-63/2023-24Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Stay complete
154
-
-
33 KV XLPE Cable 3x300 sq.mm. (for underground)
4580
-
-
ACSR Dog Conductor
24500
-
-
33 KV Pin Insulator with pin
714
-
-
33KV Disc Fitting
120
-
-
33KV Disc Insulator 70KN
480
-
-
33 KV PG Clamp
228
-
-
GI Wire 6 swg
2450
-
-
GI Wire 10 swg
1634
-
-
33 KV Line Isolator
4
-
-
Supply of following of material :
-
-
-
HDPE , PN-6 Pipe (200mm. Dia) with Clamps etc.
3856
-
-
33 KV cable Jointing Kit 3x300sq.mm. (outdoor)
33
-
-
Stone Pad
260
-
-
33 kV F- Bracket
200
-
-
33 kV V Type Cross Arm
170
-
-
Top Channel size 125x65x2240 mm.
38
-
-
Dropper Channel size 100x50x2028 mm.
38
-
-
Tee off Chennal size 125x65x1300 mm.
60
-
-
Cross Bracing Angle MS Angle Iron (65x65x6, 4300mm.)
44
-
-
Cross Arm Holding Clamp
230
-
-
Gaurding Angle
260
-
-
Pole Clamp with bolt & nut
284
-
-
Barbed wire
487
-
-
Danger Board with Clamp
230
-
-
Nut Bolt & Washer
520
-
-
Number Plate with clamp
238
-
-
Alluminum Paint
260
-
-
Red Oxide Paint
260
-
-
Alluminum Binding Wire
122
-
-
I Bolt
400
-
-
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm/ F-Braket, 3 No. Pin insulator as per norms.
200
-
-
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., Disc insulator 6 No. and 3 No. Pin insulator as per norms.
13
-
-
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Exposure Double pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm, Bracing angle 1 set., and 9 No. Pin insulator as per norms.
9
-
-
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Four pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 4 No Top channel of 125x65x6 mm size 3200 mm, 4 set Bracing angle, 8 No. Pin insulator, 24 No. Disc Insulator, 06 No. Disc Fitting and 08 No. E-Braket as per norms.
4
-
-
Grouting of 13 Mtr. ST Pole by digging of pit 1.83 Mtr deep, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
260
-
-
Cradle Guarding of 33 KV line at road crossing, 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting.
7200
-
-
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material will be arranged by the contractor )
154
-
-
Earthing of Pole ST Pole by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect.
260
-
-
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point.
24500
-
-
Digging of trench and laying of 3x300 sq. mm XLPE Cable underground Double Circuit in HDPE Pipe :
Laying of Double circuit 3x300 sq .mm XLPE Cable (2x1530 Mtr.) in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.40 M. After laying the cable in HDPE pipe refilling and ramming of the left out soil,closing the trench and leveling.
1010
-
-
Installation of 33 KV 3x300 sq. mm Outdoor End Terminations for 33 kV XLPE Cable
33
-
-
Fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height.
260
-
-
Fixing of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55
230
-
-
Fixing of Number plate of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55
238
-
-
Line Isolator Structure
Fabrication of isolator structures 3.5mtr in height as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.9 x0.3 Mtr providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 mtX 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with runner of isolator in proper allingment level and plumb. Plinths of the Isolator structure shall be properly finished with champering of edges.(All the material will be supplied by the Contractor like M.S Flat etc.)
4
-
-
Installation of Line Isolators Assembling and installation of Line isolator on the Isolator structure , adjusting of opening mechanism in proper alignment so as to ensured smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
4
-
-
Laying of cable & HDPE Pipe
Laying of Single circuit 33 KV 3x300 Sq mm XLPE cable and HDPE Pipe by drilling method below NHAI Road / Railway crossing. Twin cables be laid parallelly (2x760 Mtr) at the depth of 3 mtr from the under surface in HDPE pipe (200 mm. dia.) casing.
1520
-
-
NOC will be granted from Central/ state Electrical safety department.( Final settlement of the payment will be on the basis of Quotation of expenditure of proovided by the contractor in BOQ or cost of expenditure provided by electrical saftey which is low).
1
-
-
Permission of NHAI/PWD/RAILWAY etc. for road crossing. .( Final settlement of the payment will be on the basis of Quotation of expenditure provided by the contractor in BOQ or cost of expenditure provided by NHAI Depaartment whichever is low.)
2
-
-
permission of cutting and chopping of tree from forest deppt. ( (.Final settlement of the payment will be on the basis of Quotation of expenditure provided by the contractor in BOQ or Quotation of expenditure provided by FOREST department which is low))
1
-
-
Restoring the road as it is before after completion of work
1010
-
-
Painting of poles Painting of poles with one coat of red oxide, two coats of enamel paint ISI mark.