Dakshinanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date25 Jan 2024
Closing DateCancelled
Tender Amount₹ 1,61,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Stay complete

154

-

-

... More
33 KV XLPE Cable 3x300 sq.mm. (for underground)

4580

-

-

... More
ACSR Dog Conductor

24500

-

-

... More
33 KV Pin Insulator with pin

714

-

-

... More
33KV Disc Fitting

120

-

-

... More
33KV Disc Insulator 70KN

480

-

-

... More
33 KV PG Clamp

228

-

-

... More
GI Wire 6 swg

2450

-

-

... More
GI Wire 10 swg

1634

-

-

... More
33 KV Line Isolator

4

-

-

... More
Supply of following of material :

-

-

-

... More
HDPE , PN-6 Pipe (200mm. Dia) with Clamps etc.

3856

-

-

... More
33 KV cable Jointing Kit 3x300sq.mm. (outdoor)

33

-

-

... More
Stone Pad

260

-

-

... More
33 kV F- Bracket

200

-

-

... More
33 kV V Type Cross Arm

170

-

-

... More
Top Channel size 125x65x2240 mm.

38

-

-

... More
Dropper Channel size 100x50x2028 mm.

38

-

-

... More
Tee off Chennal size 125x65x1300 mm.

60

-

-

... More
Cross Bracing Angle MS Angle Iron (65x65x6, 4300mm.)

44

-

-

... More
Cross Arm Holding Clamp

230

-

-

... More
Gaurding Angle

260

-

-

... More
Pole Clamp with bolt & nut

284

-

-

... More
Barbed wire

487

-

-

... More
Danger Board with Clamp

230

-

-

... More
Nut Bolt & Washer

520

-

-

... More
Number Plate with clamp

238

-

-

... More
Alluminum Paint

260

-

-

... More
Red Oxide Paint

260

-

-

... More
Alluminum Binding Wire

122

-

-

... More
I Bolt

400

-

-

... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm/ F-Braket, 3 No. Pin insulator as per norms.

200

-

-

... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., Disc insulator 6 No. and 3 No. Pin insulator as per norms.

13

-

-

... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Exposure Double pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm, Bracing angle 1 set., and 9 No. Pin insulator as per norms.

9

-

-

... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Four pole for 33 KV Line on 13.0 Mtr S.T. Pole with fitting of necessary clamp & other acessories like 4 No Top channel of 125x65x6 mm size 3200 mm, 4 set Bracing angle, 8 No. Pin insulator, 24 No. Disc Insulator, 06 No. Disc Fitting and 08 No. E-Braket as per norms.

4

-

-

... More
Grouting of 13 Mtr. ST Pole by digging of pit 1.83 Mtr deep, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.

260

-

-

... More
Cradle Guarding of 33 KV line at road crossing, 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting.

7200

-

-

... More
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material will be arranged by the contractor )

154

-

-

... More
Earthing of Pole ST Pole by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect.

260

-

-

... More
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point.

24500

-

-

... More
Digging of trench and laying of 3x300 sq. mm XLPE Cable underground Double Circuit in HDPE Pipe : Laying of Double circuit 3x300 sq .mm XLPE Cable (2x1530 Mtr.) in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.40 M. After laying the cable in HDPE pipe refilling and ramming of the left out soil,closing the trench and leveling.

1010

-

-

... More
Installation of 33 KV 3x300 sq. mm Outdoor End Terminations for 33 kV XLPE Cable

33

-

-

... More
Fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height.

260

-

-

... More
Fixing of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55

230

-

-

... More
Fixing of Number plate of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55

238

-

-

... More
Line Isolator Structure Fabrication of isolator structures 3.5mtr in height as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.9 x0.3 Mtr providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 mtX 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with runner of isolator in proper allingment level and plumb. Plinths of the Isolator structure shall be properly finished with champering of edges.(All the material will be supplied by the Contractor like M.S Flat etc.)

4

-

-

... More
Installation of Line Isolators Assembling and installation of Line isolator on the Isolator structure , adjusting of opening mechanism in proper alignment so as to ensured smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.

4

-

-

... More
Laying of cable & HDPE Pipe Laying of Single circuit 33 KV 3x300 Sq mm XLPE cable and HDPE Pipe by drilling method below NHAI Road / Railway crossing. Twin cables be laid parallelly (2x760 Mtr) at the depth of 3 mtr from the under surface in HDPE pipe (200 mm. dia.) casing.

1520

-

-

... More
NOC will be granted from Central/ state Electrical safety department.( Final settlement of the payment will be on the basis of Quotation of expenditure of proovided by the contractor in BOQ or cost of expenditure provided by electrical saftey which is low).

1

-

-

... More
Permission of NHAI/PWD/RAILWAY etc. for road crossing. .( Final settlement of the payment will be on the basis of Quotation of expenditure provided by the contractor in BOQ or cost of expenditure provided by NHAI Depaartment whichever is low.)

2

-

-

... More
permission of cutting and chopping of tree from forest deppt. ( (.Final settlement of the payment will be on the basis of Quotation of expenditure provided by the contractor in BOQ or Quotation of expenditure provided by FOREST department which is low))

1

-

-

... More
Restoring the road as it is before after completion of work

1010

-

-

... More
Painting of poles Painting of poles with one coat of red oxide, two coats of enamel paint ISI mark.

260

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.