Dakshinanchal Vidyut Vitran Nigam Limited Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Electrical and Electronics
Eprocure
Opening Date23 Apr 2024
Closing Date1 Jun 2024
Tender Amount₹ 1,70,00,000
Costs
EMD
₹ 1,70,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_922904_1Bid Award Id
ViewTender No
91/EDCA/2023-24Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
P.G. Clamps
204
-
-
... More
Al. Binding Wire
40
-
-
... More
33 KV Earth Wire Clamp
2
-
-
... More
Battery Charger
1
-
-
... More
33 KV M.S Angle off size
3
-
-
... More
33 KV Top Channel off size
3
-
-
... More
Battery Set 24 V DC (Exide Make)
1
-
-
... More
Aluminium Paint
2
-
-
... More
Red oxide paint
2
-
-
... More
Danger Board With Clamp
82
-
-
... More
11 KV CT for BHEL VCB O/G 200/100/5 Amp.
12
-
-
... More
11 KV CT for BHEL VCB O/G 600/300/5 Amp.
9
-
-
... More
11 KV Vaccum Interputter for BHEL make VCB
18
-
-
... More
11 KV Spout for BHEL make VCB
5
-
-
... More
Male & Female connector for BHEL make VCB
36
-
-
... More
Suspension Clamp with eye-hook
507
-
-
... More
Dead End Clamp
132
-
-
... More
MCCB UNIT for 250/400 KVA T/Fs.
14
-
-
... More
MCCB UNIT Clamp for 250/400 KVA T/Fs.
10
-
-
... More
Distribution Box Clamp
407
-
-
... More
Cable holding Clamp
15
-
-
... More
Stay Set Complete
100
-
-
... More
Number Plate
62
-
-
... More
F-bracket for PCC/STP Poles
92
-
-
... More
33 KV M.S. T-off Channel
6
-
-
... More
Clamp for T-Channel
14
-
-
... More
Nut & Bolt off size
197
-
-
... More
11 KV 3x120 sqmm Jointing Kit (indoor)
4
-
-
... More
11 KV 3x120 sqmm Jointing Kit (outdoor)
6
-
-
... More
33 KV V Type Cross Arm
101
-
-
... More
11 KV V Type Cross Arm
17
-
-
... More
33 KV Cross Arm clamp
95
-
-
... More
11 KV Cross Arm clamp
23
-
-
... More
9/8.5 Mtr. PCC Pole clamp
34
-
-
... More
H.T. T Channel
9
-
-
... More
Part-B (Erection work)
Cartiage of (33 KV 3x240 sqmm XLPE Cable, Control Cable 2x2.5 & 4x2.5 sqmm, LT PVC cable 1x400sqmm and 11 KV 3x120 sqmm XLPE cable from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
1780
-
-
... More
Cartiage of 33 KV CT (200/100/1-1A, 400/200/1-1A & 33 KV PT, 11 KV VCB I/C CTR 600/300/5 Amp, 11 KV VCB OUTGOING CTR 200/100/5 Amp. from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
19
-
-
... More
Cartiage of 33 KV VCB from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
3
-
-
... More
Cartiage of ST Pole 13/11 Mtr from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
37
-
-
... More
Cartiage of PCC Pole 9/8.5 Mtr from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
238
-
-
... More
Cartiage of Line Material from Store Center Agra to work of site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-70Kms.) Line material viz. Aerial bunch conductor/Weasal conductor/Dog/ Rabbit, G.I. earth wire, cross arm, angle, channel, insulators, clamps, Dist. Box, and other line material, if required in Estimate/Package.
100
-
-
... More
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) on Single Pole 13 Mtr. long ST poles including fixing of all accessories for 33/11 KV line as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
33
-
-
... More
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) on Single Pole 11 Mtr. long ST poles including fixing of all accessories for 11 KV line as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
4
-
-
... More
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) Single Pole on 9 Mtr. long PCC poles including fixing of all accessories, barbed wire for 11 KV/LT Line as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
42
-
-
... More
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) Single Pole on 8.5 Mtr. long PCC poles including fixing of all accessories, barbed wire for 11 KV/LT Line as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
196
-
-
... More
Laying sagging stringing and binding and jumpering of ACSR Weasel Conductor at 11 KV/LT line as per RESPO norms It includes the cost of labour, T & P carrier etc required for proper completion of work.
2300
-
-
... More
Laying sagging stringing and binding and jumpering of ACSR Dog Conductor at 11 KV/LT line as per RESPO norms It includes the cost of labour, T & P carrier etc required for proper completion of work.
500
-
-
... More
Laying sagging stringing and binding and jumpering of 3x50 sqmm ABC at 11 KV/LT line as per RESPO norms It includes the cost of labour, T & P carrier etc required for proper completion of work.
8900
-
-
... More
Laying sagging stringing and binding and jumpering of 3x95 sqmm ABC at 11 KV/LT line as per RESPO norms It includes the cost of labour, T & P carrier etc required for proper completion of work.
12750
-
-
... More
Laying of L.T. Cable size 1x400 sqmm as per RESPO Norms and direction by superivising by Engineer.
30
-
-
... More
Hoisting and Stringing of 11 KV 3x120 sqmm XLPE overhead Cable includes unroling cutting /megaring & sealing both ends as per Norms.
700
-
-
... More
Hoisting and Stringing of 33 KV 3x240 sqmm XLPE overhead Cable includes unroling cutting /megaring & sealing both ends as per Norms.
150
-
-
... More
for the work of Chemical Earthing for 250 KVA/400 KVA T/Fs as per RESPO Manual.(All material provided by the contractor at his own cost)
278
-
-
... More
for the work of Chemical Earthing for 33 KV VCB as per RESPO Manual.(All material provided by the contractor at his own cost)
2
-
-
... More
Construction of plinth of size 5' * 5 * 4' above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand. .(All material provided by the contractor at his own cost)
124
-
-
... More
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut ..(All material provided by the contractor at his own cost)
159
-
-
... More
Earthing of 5/8/10 MVA Power transformer by maintenance free Earthing Electrods (Chemical) by digging pits 6" dia upto 3mtr. deep including inserting pipe in pipe technology concept involve two mild steel pipes one inserted inside. One inserted inside the other of size- 1- Inner pipe dia 50mm. 2- Outer pipe dia 100mm and length of the both pipe shall be 3000 mm. The M.S.pipe shall be ISI mark of class B as per IS 1239. Thickness of the pipe shall be 12 SWG. The empty space in the pipe shall be filled with the specially developed crystalline material conductive mixture such as copper and aluminimum powder, conductive carbon and bonding material etc. mixed in diffrent proportions. Conductive mixture contents shall be 70 % carbon powder & 30% metal powder preferably pure copper or aluminum material along with the required quantity of bonding materials. Granule size of the carbon & metal powder shall be 100 mesh. The mixture if forced (pressurized) inside the earth electrode in empty space of inner pipe & in empty space between the inner & outer pipe of the earth electrode, in paste form and after solidification of the same the bottom end cap as well as top end cap is provided. The mixture shall be pressed by machine in the pipe. Precaution shall be taken so as no air gap inside the pipe while pressing. The back fill compound (earth enhancment material ) shall be superior conductive material that improves earthing effectiveness especially in areas of poor conductivity such as rocky ground, sandy soil & areas of moisture varation. It may contain conductive cement (20%) graphite carbon powder(50%), hydrous aluminum siliacate (10%), Sodium montmorillonite (20%) etc. it shall be placed around earth electrode in the earth pit to improve the conductive of earth electrode & ground contact area. Mild steel electro galavanized Flat 50x6 mm shall welded to earth electrode pips & connected with Trasnformer netural / body as below with the hlep of steel nut & bolt or through welding as per site requirment to 80mm GI pipe and filling of chemical mixutre around the GI pipe upto 3 mtr. including making of chamber & connecting the top of the inserted pipe and transformer body / neutral through M.S.flat 50x6mm with the help of nut & bolt or through welding and making a main hole of size 2'×2' and covering the same by a stone pad for the purpose of poring water for moisture. Body Earthing of Transformers, Neutral Earthing of Transformers.
9
-
-
... More
Erection and grouting stay of ratio 1:2:4 (cement, sand and bricks balast) as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
100
-
-
... More
Fixing of earthing rod as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
1579
-
-
... More
Fixing of P.G. Clamps as per RESPO norms
204
-
-
... More
Fixing of Danger Boards With clamps (shock Proof, Rust Proofs) on Poles as per RESPO norms.
82
-
-
... More
Fixing of 11 KV Control Panel incoming as per RESPO Manual.
2
-
-
... More
Fixing of Number plates on Poles as per RESPO norms.
62
-
-
... More
Filling of 11KV 3x120 sqmm Indoor Jointing Kit and making connection as per direction of supervising engineer.
4
-
-
... More
Filling of 11KV 3x120 sqmm outdoor Jointing Kit and making connection as per direction of supervising engineer.
6
-
-
... More
Guarding of HT line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr. including the cost of arrangement of abour, T&P etc.required for proper completion of work.
10
-
-
... More
Installlation & Commissioning of 33 KV CT & 400/200/1-1A complete work as per RESPO Manual.
4
-
-
... More
Installlation & Commissioning of 33 KV CT 200/100/1-1A complete work as per RESPO Manual.
6
-
-
... More
Installlation & Commissioning of 33 KV P.T. complete work as per RESPO Manual.
5
-
-
... More
Installlation & Commissioning 11 KV VCB I/C CTR 600/300/5 Amp complete work as per RESPO Manual.
1
-
-
... More
Installlation & Commissioning 11 KV VCB OUTGOING CTR 200/100/5 Amp Outdoor complete work as per RESPO Manual.
3
-
-
... More
Installation of 33 KV VCB proper alignment and direction and jointing of earthing strips with help of gas welding and making cable connection including shifting dragging with all other associated works.
3
-
-
... More
INSTALLATION OF 33 KV BUS ISOLATOR :-
Assembling and installation of line / bus isolator on the isolator structure Adjusting of operating machanism in proper alignment so as to ensure smooth operation of the same in case of line isolator proper operating of earth links shall be ensured. The work includes fabrication for proper fixing if required.
1
-
-
... More
Centrifusing and filteration of 5/8/10 MVA Power T/F at destination S/S including testing of T/F oil to give BDV value not less than 60 KV when tested with 2.5 mm gap electrode. including opening of radiators, conservator tank & other accessories as required and drain out T/F oil in drums & unloading at destination place & fitting of radiator, conservator tank & other accessories and filling of T/F oil safely. & all T&P, crane, Trolla etc as required is to be arranged by the contractor at his own cost.
2
-
-
... More
Fixing of LT dustribution boxes on already errected pole for giving supply to consumer by connecting consumer cables by using appropriated alumunium lugs tape N & B provided by conractor as per requirement.
407
-
-
... More
Installation of 11 KV D.O. Fuse set as per RESPO NORMS
56
-
-
... More
Installation & Energization of Battery set & Charger of Standard make and as per RESPO Norms.
1
-
-
... More
Laying of control cable 2x2.5 sqmm as per site requirment and RESPO Norms.
400
-
-
... More
Laying of control cable 4x2.5 sqmm as per site requirment and RESPO Norms.
500
-
-
... More
Fixing of Tellless Unit on Distribution T/Fs as per Site requirment and RESPO Norms.
77
-
-
... More
Making HT 'T-off connection on existing mains labour, T &P and carrier etc. required for proper completion of work.
6
-
-
... More
Painting of Poles with single coat of red oxide primer and Double coat of Aluminium paint at his own cost. per RESPO norms.
4
-
-
... More
Repairing of 33 KV Control Relay Panel of Power Transformer as per site requirment and RESPO Norms.
4
-
-
... More
Erection work of 33 KV main Line Isolator with Steel structure as per site requirment and RESPO Norms.
1
-
-
... More
Erection work of 33 KV Branch Line isolator as per site requirment and RESPO Norms.
2
-
-
... More
Fixing of MCCB Unit LT on Distribution T/Fs as per Site requirment and RESPO Norms.
14
-
-
... More
Removal and Cartiage of old & Used Material (ACSR Weasel conductor-2400 Kg, I/C VCB-01 Nos, O/G VCB-02 Nos and LT ABC 3x95 sqmm - 200 KG. (Apprx 00-70 KM)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements