Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Eprocure
Opening Date26 Nov 2024
Closing Date2 Dec 2024
Tender Amount₹ 18,00,000
Costs
EMD
₹ 21,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_967275_2Tender No
EDCBNDA-09/2024-25Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Erection & fixing of Battery Charger 24V alongwith fitting of all accessories as per RESSPO manual. Arrangement of all suitable fittings material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
2
-
-
Erection & fixing of 33 KV Lightening Arrestor alongwith fitting of all accessories and making foundation, if required, as per RESSPO manual. Arrangement of all suitable foundation material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
17
-
-
Supply & fixing of Buchholz Relay alongwith fitting of all accessories as per RESSPO manual (Arranged by contractor at his own cost).
3
-
-
Supply & fixing/laying of Control Cable 4x2.5 Sq.mm.. All accessories are also included in the work (Arranged by contractor at his own cost). Control Cable supplied by contractor should be as per standard.
375
-
-
Erection & fixing of CT 33 KV 200/100/1 A alongwith fitting of all accessories and making foundation, if required, as per RESSPO manual. Arrangement of all suitable foundation material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
5
-
-
Erection & fixing of PT 33 KV/110 V O/D alongwith fitting of all accessories and making foundation, if required, as per RESSPO manual. Arrangement of all suitable foundation material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
5
-
-
Erection & fixing of 33 KV Line Isolator 1200/800 A alongwith fitting of all accessories and making foundation, if required, as per RESSPO manual. Arrangement of all suitable foundation material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
6
-
-
Erection & fixing of 33 KV Bus Isolator 800 A alongwith fitting of all accessories and making foundation, if required, as per RESSPO manual. Arrangement of all suitable foundation material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
6
-
-
Safely & carefully installation of Control Pannel Relay for Power T/Fs at Sub-Stations, inlcuding the work of cartage & fixing of Control Pannel Relay in proper position and alignment & checking complete work with earthing as per schedule and RESSPO Drawing.
1
-
-
Supply & fixing of W.T.I. alongwith fitting of all accessories as per RESSPO manual. Arrangement of all suitable W.T.I. material by tenderer at his own cost as per actual site requirement
3
-
-
Supply & fixing of O.T.I. alongwith fitting of all accessories as per RESSPO manual. Arrangement of all suitable O.T.I. material by tenderer at his own cost as per actual site requirement
3
-
-
Safely & carefully installation of 33 KV VCB (Incoming/Outgoing) Control Pannels for Power T/Fs at Sub-Stations, inlcuding the work of cartage & fixing of switchgear (VCB Panel), CT 200/100/1-1A & Steel Structures on foundation with nut & bolts in proper position and alignment & checking complete work with earthing as per schedule and RESSPO Drawing.
4
-
-
Construction of plinth & foundation for 33 KV VCB (Indoor/Outdoor) Control panel as per standard/RESPPO manual, if required.
4
-
-
T/F Body Earthing Complete by deep boring of T/F as per norms. Arrangement of all suitable earthing material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
5
-
-
Neutral Earthing Complete by deep boring of T/F as per norms. Arrangement of all suitable earthing material by tenderer at his own cost as per actual site requirement, including the cost of labour, T&P and carrier etc. required for proper completion of work.
4
-
-
The work of electrical/mechanical repairing/maintenance & overhauling of damaged various make 33 KV Vaccum/Oil Circuit Breakers (VCB/OCBs) installed at various 33 KV Incoming & Outgoing Feeders, including replacement of various type's spare parts as per requirement of site & testing in concern various 33/11 KV Sub-Stations. All the T&P/vehicle etc. required for repairing of above VCB/OCBs shall be arranged by the contractor at his own cost & risk. All type of material/spare parts required for the work of repairing/overhauling of above VCB/OCBs shall be provided by the contractor at his own cost, including loading, unloading, safe dragging at site.
3
-
-
The work of electrical/mechanical repairing/maintenance & overhauling of damaged various make 11 KV Vaccum/Oil Circuit Breakers (VCB/OCBs) installed at various 11 KV Incoming & Outgoing Feeders, including replacement of various type's spare parts as per requirement of site & testing in concern various 33/11 KV Sub-Stations. All the T&P/vehicle etc. required for repairing of above VCB/OCBs shall be arranged by the contractor at his own cost & risk. All type of material/spare parts required for the work of repairing/overhauling of above VCB/OCBs shall be provided by the contractor at his own cost, including loading, unloading, safe dragging at site.
5
-
-
THE WORK OF MAINTENANCE/REPAIRING AND REPLACEMENT OF DAMAGED PARTS FOR AVOIDING OIL LEAKAGE AND OTHER PROBLEMS OF 5/8/10 MVA POWER T/Fs INSTALLED AT VARIOUS 33/11 KV SUB-STATIONS, Details of the work as given below ;-
1& ifjorZZdksa ds lHkh 11 dsoh ,oa 33 dsoh ds tEQjksa@dsfcyksa dks [kksyuk@vyx djuk rFkk VkWi doj ds uV&cksYV [kksydj] VkWi doj dks Øsu vFkok Jfedksa dh lgk;rk ls lqjf{kr gVkukA
2& ifjorZdksa ds datjosVj VSadksa@jsfM,Vj dks [kksydj ifjorZd ls vyx djukA
3& ifjorZdksa dk rsy okafNr Lrj rd fudkyus ,oa lko/kkuhiwoZd Mªeksa esa HkjukA
4& VSad dh dkdZ lhV cnyuk] 11 ds0oh0 ,oa 33 ds0oh0 cqf'kax dh iSfdax vkfn cnyuk] vkW;y VSad dh iSfdax cnyuk ,oa okYoksa dh iSfdax cnyuk ¼leLr lkexzh dh O;oLFkk Bsdsnkj }kjk dh tk;sxh½A
5& ifjorZdksa ds dsfcy ckWDl@cqf'kax@cqf'kax jkMksa@flydk tsy dks cnyuk ¼leLr lkexzh dh O;oLFkk Bsdsnkj }kjk dh tk;sxh½A
6& mijksDr lHkh dkdZ lhV ,oa iSfdax cnydj vkW;y VSad rFkk jsfM,Vj vkfn dks leqfpr LFkku ij dq'kyrkiwoZd iqu% LFkkfir djuk@yxkukA
7& vkW;y VSad dks leqfpr LFkku ij yxkus@LFkkfir djus ds mijkUr lko/kkuh iwoZd vkW;y dks VSadksa esa iqu% Mkyuk rFkk VSadksa dks iqu% Hkyh&Hkkafr leqfpr :Ik ls cUn djuk ¼vko';drkuqlkj VªkUlQkeZj vkW;y foHkkx }kjk miyC/k djk;k tk;sxk] ftldh Hk.Mkj dsUnz ls dk;Z LFky ij ynkbZ] mrjkbZ ,oa +qykb fufonknkrk Lo;a dh tk;sxh½A
8& 11 ds0oh0 ,oa 33 ds0oh0 cqf'kax dh lQkbZ djukA
9& ifjorZdksa ds lHkh 11 dsoh ,oa 33 dsoh ds tEQjksa@dsfcyksa dks iqu% tksM+ukA