Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Apr 2024
Closing Date4 May 2024
Tender Amount₹ 15,00,000
Costs
EMD
₹ 15,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Summary
Work Of Replacement Of Jarjar Conductor, Poles And Associated Work On 33/11kv/lt Lines
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_919133_4Bid Award Id
ViewTender No
118/2023-24/EDC ETAHTender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Pre qualification and Technical Documents.
BOQ Items
Errection of 8.5 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc and other work complete as per RESPO norms.
200
-
-
Errection of 9/11 mtr. Long ST poles as single support including fixing of all HT/LT accessories etc and other work complete as per RESPO norms.
25
-
-
Errection of 8.5 mtr. long PCC poles as D.Pole/section pole including fixing of all HT/LT accessories etc and other work complete as per RESPO norms.
35
-
-
Errection of 9/11 mtr. long PCC poles as D.Pole/section pole including fixing of all HT/LT accessories etc and other work complete as per RESPO norms.
5
-
-
Dismantling and removal of following conductor from the various area, stacking and placement their coils and their in the safer place including cost of lobour T&P etc. required for proper completion of work. (i) ACSR weasel conductor
15
-
-
(ii) Raccoon / Dog conductor
6
-
-
(iii) ABC Cable 3x120+1x70+1x16
3
-
-
(IV) ABC Cable 3x95+1x35+1x16
3
-
-
(V) ABC Cable 3x50+1x35+1x16
3
-
-
Opening of the accessories from damaged/brocken Double pole including all cost of labour and T&P etc.
40
-
-
Laying sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work. (i) ACSR weasel conductor
15
-
-
(ii) Raccoon / Dog conductor
6
-
-
(iii) ABC Cable 3x120+1x70+1x16
3
-
-
(IV) ABC Cable 3x95+1x35+1x16
3
-
-
(V) ABC Cable 3x50+1x35+1x16
3
-
-
Straighting of tilted PCC/R.S.Joist poles/Round Pole of HT/LT line after opening of nozzling, digging of pit applying anti direction force for making of proper alignment of line.
75
-
-
Strainthing of tilted D/P after opening of connection applying anti direction force, digging of dug for proper alignment of line.
30
-
-
Opening of HT/LT connections & lowering of 25/63 KVA T/F from D/P and shifting up to in safer place.
35
-
-
Re-sagging of following loose conductor as per direction of supervising engineer. It includes the cost of labour, T & P carrier etc required for proper completion of work. (a) ACSR Weasel cunductor
25
-
-
( b ) Raccoon / Dog conductor
6
-
-
(c) ABC Cable 3x120+1x70+1x16
4
-
-
(d) ABC Cable 3x95+1x35+1x16
4
-
-
(e) ABC Cable 3x50+1x35+1x16
4
-
-
Earthling of PCC Pole with MS Earth Rod as per RESPO Specification.
70
-
-
Retightening of Stay rod. Etc. complete.
200
-
-
Providing fixing of stay rod with nuzzling etc. complete.
100
-
-
Replacement of following broken/damaged/missing accessories by new accessories including opening of the same and refixing.
(i) 11 KV cross arms ‘V’ type
150
-
-
(ii) 11 KV pin insulator
150
-
-
(iii) 11 KV pin with nut
150
-
-
(iv) 11 KV disc insulator
130
-
-
(v) Cross arms holding clamps
130
-
-
(vi) F clamps
130
-
-
(vii) Stays Clamp
130
-
-
(viii) LT pin clamp
130
-
-
(ix) Shackle insulator
130
-
-
Carriage of old material from pit site to JE store/store center Etah in distance range 0 to 60 km. including loading & unloading and proper stacking.
50
-
-
Mounting of 25/63 KV Transformers on double pole including making of the connection etc complete.
35
-
-
Repairing/ resagging/ new guarding of HT Line with GI wire as per RESPO Norms.
6
-
-
Chopping of tree branches
8
-
-