Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Eprocure
Opening Date15 Dec 2024
Closing Soon28 Dec 2024
Tender AmountRefer Documents
Costs
EMD
₹ 20,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_983720_1Tender No
ESWCA-12/2024-25Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
33 KV Bus Type Isolator Structure Material
2
-
-
... More
33 KV Post Insulator Structure Material
2
-
-
... More
33 KV Main Bus Structure Material
1
-
-
... More
Indoor Equipment Earthing Material
1
-
-
... More
33 KV CT Structure Material
2
-
-
... More
33 KV PT Structure Material
1
-
-
... More
Earthing Material of power transformer Netutal and body (strip 50x6mm M.S strip 6Mt, earth electrod G.I Pipe 40mm Dia 2.9mm thick water level)
3
-
-
... More
Supply & providing of following Material & including Miscellaneous line items requried of line makeing (Electrical Material As Per RESPO Norms,Drawing.) :-
200
-
-
... More
Control Cable 2x2.5 Sq. mm.Cu. Xlpe
200
-
-
... More
Cemical Erathing for LA,CT,VCB,Post Insulator & Fuse Set (earthing Material main earth strip 35x6mm G.S and branch strip 25x6mm 4Mt.for above Structure with earth electrod Job for as per site requried)
10
-
-
... More
Painting matrials(black bituminous,red oxide,Aluminium paint,and RYB TYPE colours etc.)
1
-
-
... More
Safe carriage,loading,unloading,dragging & stacking of following material from store center to contractors dump site to pit site asper requirement :-
-
-
-
... More
5 MVA Power Transformer
1
-
-
... More
33 KV Polymeric Pin insulator
6
-
-
... More
33 KV Post Insulator.
6
-
-
... More
33 KV Bus Type Isolator.
2
-
-
... More
33 KV Lightening Arrestors
6
-
-
... More
33 KV Fuse Set
1
-
-
... More
ACSR Dog conductor
300
-
-
... More
11KV incoming with CT ratio 600/300/5A, 350 MVA
1
-
-
... More
11KV Outgoing with CT ratio 200/100/5A, 350 MVA
2
-
-
... More
90 Lbs. Rail pieces for T/F
6.92
-
-
... More
33 KV Double Transformer Control Panel.
1
-
-
... More
33 KV VCB 800A, 750 MVA
2
-
-
... More
33 KV CT, 200/100/1-1-1A
3
-
-
... More
33 KV CT, 400/200/1-1-1A
3
-
-
... More
33Kv PT (33KV/110V)
3
-
-
... More
11 KV 3 Core XLPE Cable Al. 3x185 Sq. mm
180
-
-
... More
11 KV 3 Core XLPE Cable Al. 3x300 Sq. mm
120
-
-
... More
11 KV Heat Shrink cable Jointing kit 3x300 Sq. mm Indoor
2
-
-
... More
11 KV Heat Shrink cable Jointing kit 3x300 Sq. mm Outdoor
2
-
-
... More
11 KV Heat Shrink cable Jointing kit 3x185 Sq. mm Indoor
2
-
-
... More
11 KV Heat Shrink cable Jointing kit 3x185 Sq. mm Outdoor
2
-
-
... More
24 Volt battery and battery charger with cabinet.
1
-
-
... More
Fabrication,Erection,installation,Fixing,Laying,saging,completion, testing and commissing of 33kv line Works.(As Per RESPO Norms &Drw.) :- exp. pit digging and erection, Grouting of s/s structur & building of plinth and .tensinoning of conductor,fitting of armour rods and binding of conductors.Jointing ,cable termination and connections,etc
-
-
-
... More
5 MVA Power Transformer safe Installation on the foundation ,fixing 90 Lbs. Rail piece and tarmination of connction with fitting
1
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV Fuse Set Structure with Sundry items and including earthing work
1
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV Lightening Arrestors Structure with Sundry items and including earthing work
2
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV Bus Type Isolator Structure with Sundry items and including earthing work
2
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV Post Insulator Structure with Sundry items and including earthing work
2
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV Main Bus bar structure with Sundry items and including earthing work
1
-
-
... More
Laying,saging ACSR Dog conductor with fitting all accessories
300
-
-
... More
11KV incoming VCB safe Installation on the foundation and connction of control wire with fitting (CT ratio 600/300/5A, 350 MVA ) and including earthing work
1
-
-
... More
11KV Outgoing VCB safe Installation on the foundation and connction of control wire with fitting( CT ratio 200/100/5A, 350 MVA) and including earthing work
2
-
-
... More
Building/making Plinth & Foundation of T/F
1
-
-
... More
33KV Double Transformer Control Panel safe Installation and connction of control wire with fitting and including earthing work
1
-
-
... More
33 KV VCB 800A, 750 MVA safe Installation on the foundation and connction of control wire with fitting and including earthing work
2
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV CT(400/200/1,200/100/1AMP) Structure with Sundry items and including earthing work
2
-
-
... More
Fabrication erection, fixing all supporting accesssories and grouting of 33 KV PT Structure (33KV/110V) with Sundry items and including earthing work
1
-
-
... More
Building/making Plinth & foundation of VCB
2
-
-
... More
Laying,termination and connections of 11 KV 3 Core XLPE Cable Al. 3x185 Sq. mm
180
-
-
... More
Laying,termination and connections of 11 KV 3 Core XLPE Cable Al. 3x300 Sq. mm
120
-
-
... More
Making/building and dressing of 11 KV Cable Trench 450mm wide,900mm deep shoud be excavated 5cm layer of sand shall be place at the bottom Including cost of sand & bricks
180
-
-
... More
Fixing ,prepare and Making Indoor type 11 KV cable Jointing kit 3x300 Sq. mm
2
-
-
... More
Fixing ,prepare and Making Outdoor type 11 KV cable Jointing kit 3x300 Sq.mm
2
-
-
... More
Fixing ,prepare and Making 11 KV cable Indoor type Jointing kit 3x185 Sq.mm
2
-
-
... More
Fixing ,prepare and Making 11 KV cable Outdoor type Jointing kit 3x185 Sq.mm
2
-
-
... More
Installation,Fixing 24 Volt battery and battery charger with proper conntion
1
-
-
... More
Laying,termination and connections of Control Cable 4x2.5 Sq. mm.Cu. Xlpe
200
-
-
... More
Laying,termination and connections of Control Cable 2x2.5 Sq. mm.Cu. Xlpe
200
-
-
... More
Neutral & Body earthing work of power transformer (water level)
2
-
-
... More
Painting work of Steel Structures
1
-
-
... More
High Pressure testing with DC test voltage to which 33kv cable shall withstand for duration of 5minutes of 36kv affter completion of laying jointing & termination all the T&P and labour required for successful completion of work shall be supplied by contractor
2
-
-
... More
Note:-
(1) The Branch strf to the main mat at 15-20 meter Interval.
(2) The 2.5 Meters long 40 mm DIA Galvanised pipes shall be driven to their full length so that top is at least 500 mm below the ground level and welded to the strip of ground mat . (3) Wherever the main ground strips cross each other they will be welded on crossing points.
(4) All Non current carrying metallice equipments are to be grounded at two distinct points by connecting them to the main mat.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%