Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Aug 2024
Closing DateCancelled
Tender Amount₹ 6,00,000
Costs
EMD
₹ 6,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_922901_3Bid Award Id
ViewTender No
126/2023-24/EDC ETAHTender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
MS Top Channel
4
-
-
MS Dropper Channel
4
-
-
Guarding Angle
6
-
-
MS T off Channel with Clamp
48
-
-
11 KV F Clamp/F Bracket
84
-
-
LT PVC Cable 3.5x70/35 sq mm
16
-
-
LT Pin Clamp for STP
4
-
-
Double Pole Clamp
12
-
-
11 KV Fuse Set
3
-
-
Nut and Bolts off size
23
-
-
Suspension Clamp
24
-
-
I Hook
30
-
-
Dead and Clamp
16
-
-
Holding Clamp
12
-
-
3 Phase Distribution Box
2
-
-
3 Phase Distribution Box Clamp
4
-
-
GI Wire 10 SWG
21
-
-
Erection Work :-
-
-
-
Safe carriage of line material from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both ends.
50
-
-
Safe Carriage of 8.5 Mtr Long PCC Pole from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 60 Kms. Including loading and unloading at both side
78
-
-
Safe Carriage of 11/13 Mtr Long ST Pole from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 60 Kms. Including loading and unloading at both side
47
-
-
Safe Carriage of 100 KVA TF from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 60 Kms. Including loading and unloading at both side.
1
-
-
Safe Carriate of following 11 KV XLPE Cable from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both ends.
-
-
-
11 KV XLPE Cable 3x120 sq mm
510
-
-
11 KV XLPE Cable 3x70 sq mm
140
-
-
Safe Carriate of 11 KVB VCB from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both ends.
1
-
-
Erection of 8.5 mtr long PCC Pole as single support including fixing of HT/LT accessories etc complete, pole should be gruted properly as per DVVNL/Respo norms.
66
-
-
Erection of 8.5 mtr long PCC Pole as Double Pole/Section Pole including, drilling, cutting etc and fixing of all HT/LT accessories with TPMO etc complete, pole should be grouted properly as per DVVNL/RESPO norms.
2
-
-
Erection of 11/13 mtr ST Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms.
45
-
-
Erection of 11/13 mtr ST Pole as Double Pole/Section Pole including fixing of all HT/LT accessories etc. complete, pole should be grouted properly as per DVVNL/RESPO norms.
1
-
-
Dismantling and removal of existing ACSR Weasel/GI Wire from the various area, stacking and placement their coils and their in the safer place including cost of lobour T&P etc. required for proper completion of work.
0.5
-
-
Laying sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work.
-
-
-
ACSR Weseal Conductor
12.33
-
-
11 KV XLPE Cable 3x120 sq mm
510
-
-
11 KV XLPE Cable 3x70 sq mm
140
-
-
AB Cable 3x95 sq mm
520
-
-
AB Cable 3x50 sq mm
650
-
-
AB Cable 3x120 sq mm (Double CKT)
105
-
-
Stone Pad
41
-
-
Suspension Clamp
24
-
-
Installation of 11 KV Cable Jointing Kit O/D 3x120/3x185
4
-
-
Installation of 11 KV O/G VCB CTR 200/100/5A 350 MVA
1
-
-
Erection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
41
-
-
Earthing Complete
112
-
-
3 Phase Distribution Box with clamp
2
-
-
Dead and Clamp
16
-
-
11 KV Fuse Set
3
-
-
GI Wire 10 SWG
21
-
-
Mounting of 100 KVA TF on D/P including making of the connection etc. complete.
1
-
-
Repairing/Resagging/New guarding of HT lines with GI wire as per RESPO norms/specification.
0.5
-
-
Carriage of following old material (ACSR Weseal Conductor, X Arm Clamp etc.) from pit site to JE store/store center Etah in distance range 0 to 60 km. including loading & unloading and proper stacking.
285
-
-