Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Eprocure
Opening Date16 Dec 2020
Closing Date5 Jan 2021
Tender AmountRefer Documents
Costs
EMD
₹ 1,450Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_DVVNL_538129_1Bid Award Id
ViewTender No
EDC2A-38/2020-21Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Erection of single support including complete H.T/L.T fittings as per RESPO manual and as per direction of Engineer incharge including the cost of labour, T & P and carrier etc. required for proper completion of work.
-
-
-
PCC poles 8.5 Mtr./ 9 Mtr.
14
-
-
Erection of double pole on PCC pole/ST pole including the work of complete line as per RESPO norm manual and as per direction of Engineer Incharge including the cost of labour, T & P and carrier etc. required for proper completion of work.
-
-
-
PCC poles 8.5 Mtr/9 Mtr.
1
-
-
Laying, sagging, stringing, binding and jumpering etc. of new/old line conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work.
-
-
-
ACSR Weasal Conductor
3811
-
-
LT ABC 3x50+1x35+1x16 sq.mm BUNCH CONDUCTOR
5
-
-
Safe carriage of LT cable of size 4X16/3.5X70/35/3.5/150/70 Sq.mm. from store to respective site of work including loading unloading at both ends.
232
-
-
Laying of 4X16/3.5X70/35/3.5/150/70 mm Sq.MM XLPE cable overhead the existing new pole by of lifiting spreading the cable conducting all labour T&P etc.
232
-
-
Grouting of poles as per RESPO norms including cost of grouting material (cement: sand: brick ballast) size as per RESPO norms. This qty also includes the additional work of old & existing LT line which has to be converted into HT line. Presently the supports of old line do not have grouting.
-
-
-
PCC poles 8.5 Mtr.
16
-
-
Chopping of tree branches which are touching to 11 KV/LT lines.
10
-
-
Dismantling and removal of existing conductor/cable/GI Wire from the various area preparing their coils and then stacking in the respective JE’s (Store) as per direction of Supervising Engineer. It includes the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
-
-
-
ACSR Weasal Conductor/ GI Wire
186
-
-
Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer including the cost of labour, T&P etc. Required for proper completion of work.
16
-
-
Erection and grouting of stay set including the work of nozzling etc. as per RESPO manual and also including the cost of arrangement of all grouting material, labour, T&P etc. required for proper completion of work.
16
-
-
Providing and fixing of stay insulator.
16
-
-
Retighting of stay complete with nozelling & binding including cost of labour T&P etc required for proper completion of work.
5
-
-
Demounting & carriage of following capacity transformer due to overloaded including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
-
-
-
25 KVA T/F
26
-
-
63 KVA T/F
4
-
-
100 KVA T/F
1
-
-
Carriage and installation of site to Store of following capacity transformer due to capacity addition including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
-
-
-
16 KVA T/F
1
-
-
63 KVA T/F
28
-
-
100 KVA T/F
3
-
-
Replacement/Re-fixing of following damaged/ disturbed/de-aligned accessories:-
-
-
-
11 KV Disc Insulator
21
-
-
11 KV Pin Insulator
64
-
-
11 KV V-type Cross Arm
19
-
-
F-Bracket
23
-
-
Fixing of T-off Channel as per RESPO Norms.
7
-
-
Fixing of Stone Pad as per RESPO Norms.
17
-
-
Installation of Danger Board with clamp as per RESPO Norms.
7
-
-
Fixing of T/F Base Channel/Angle as per RESPO Norms.
6
-
-
Fixing of Top Channel as per RESPO Norms.
2
-
-
Fixing of Dropper Channel as per RESPO Norms.
2
-
-
Fixing of Holding Clamp as per RESPO Norms.
20
-
-
Providing/Fixing of missing Nut bolts and washer
16
-
-
Providing/Fixing of clamps.
2
-
-
Safe carriage of Old line material viz. Conductor, G.I. Earth wire, ABC conductor, Cross Arm, Angle, Channel, Insulators, Clamps & other line material from any other place or from site of work to store centre/ J.E. Store of its loading & unloading at the respective ends including the cost of labour, T&P and carrier etc. required for proper completion of work.