Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Apr 2024
Closing Date27 Apr 2024
Tender Amount₹ 8,50,75,426
Costs
EMD
₹ 8,50,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_922802_1Bid Award Id
ViewTender No
110/EDC(F)2023-24Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Pipe Earthing Pannel Neutral & TF Neutral & body
213
-
-
Chemical Earthing Pannel body & fencing
142
-
-
3 Phase 11kv DO Fuse Set Heavy Duty
71
-
-
ACSR Insulated Weasel for Jumpering
1420
-
-
LT Protection pannel with 03 No. of ckt by Stud type tell less fuse unit, Compatable for installtion of MCCB 500 Amp
71
-
-
Supply & intallation of 500 Amp MCCB in LT Protection pnnel Where is required
71
-
-
Foundation of LT Protection Pannel 30Cm Hieght
71
-
-
1x400 Sqmm LT PVC cable Single core
1420
-
-
All Lugs 400 Sqmm
284
-
-
All Lugs 150 Sqmm
852
-
-
Heavy duty Connector
284
-
-
Painting of Fencing with Red Oxide & Green Paint
71
-
-
Earthing of Pole by MS Earthing rod
142
-
-
Painting of Pole with Red Oxide, Al. Paint & Post office Paint
142
-
-
Interlocking of base in transformer area
852
-
-
Glanular Sub Base for laying of Interlocking Bricks
35.5
-
-
Toe Wall for Fencing
852
-
-
Clamp angle for Panel mounting support
142
-
-
Danger Board with clamp N/B
142
-
-
Number Plate with clamp N/B
142
-
-
Nut Bolt and washer
142
-
-
Reaparing of Plinth if required
71
-
-
Miscellaneous Lug, Clamp, Washer, Nut, Etc.
71
-
-
Work for LT Protection Work of 400 kva Distribution Transformer
-
-
-
GI Wire Chain Link Net for fencing Mesh D Fence Wire with foldable Gate hieght 1.52Mtr
1200
-
-
Double Through Double Pole TPMO to be Mounted on Double Pole
100
-
-
Pipe Earthing Pannel Neutral & TF Neutral & body
300
-
-
Chemical Earthing Pannel body & fencing
200
-
-
3 Phase 11kv DO Fuse Set Heavy Duty
100
-
-
ACSR Insulated Weasel for Jumpering
2000
-
-
LT Protection pannel with 05 No. of ckt. by stud type tell less fuse unit, Compatable for installtion of MCCB 800 Amp
100
-
-
Supply & intallation of 800 Amp MCCB in LT Protection pnnel Where is required
100
-
-
Foundation of LT Protection Pannel 30Cm Hieght
100
-
-
1x400 Sqmm LT PVC cable Single core
2000
-
-
All Lugs 400 Sqmm
400
-
-
All Lugs 150 Sqmm
2000
-
-
Heavy duty Connector
400
-
-
Painting of Fencing with Red Oxide & Green Paint
100
-
-
Earthing of Pole by MS Earthing rod
200
-
-
Painting of Pole with Red Oxide, Al. Paint & Post office Paint
200
-
-
Interlocking of base in transformer area
1200
-
-
Glanular Sub Base for laying of Interlocking Bricks
50
-
-
Toe Wall for Fencing
1200
-
-
Clamp angle for Panel mounting support
200
-
-
Danger Board with clamp N/B
200
-
-
Number Plate with clamp N/B
200
-
-
Nut Bolt and washer
200
-
-
Reaparing of Plinth if required
100
-
-
Miscellaneous Lug, Clamp, Washer, Nut, Etc.
100
-
-
Work for LT Protection Work of 630 kva Distribution Transformer
-
-
-
GI Wire Chain Link Net for fencing Mesh D Fence Wire with foldable Gate hieght 1.52Mtr
180
-
-
Double Through Double Pole TPMO to be Mounted on Double Pole
15
-
-
Pipe Earthing Pannel Neutral & TF Neutral & body
45
-
-
Chemical Earthing Pannel body & fencing
30
-
-
3 Phase 11kv DO Fuse Set Heavy Duty
15
-
-
ACSR Insulated Weasel for Jumpering
300
-
-
LT Protection pannel with 06 No. of ckt. by stud type tell less fuse unit, Compatable for installtion of MCCB 1000 Amp
15
-
-
Supply & intallation of 800 Amp MCCB in LT Protection pnnel Where is required
15
-
-
Foundation of LT Protection Pannel 30Cm Hieght
15
-
-
1x630 Sqmm LT PVC cable Single core
300
-
-
All Lugs 630 Sqmm
60
-
-
All Lugs 150 Sqmm
360
-
-
Heavy duty Connector
60
-
-
Painting of Fencing with Red Oxide & Green Paint
15
-
-
Earthing of Pole by MS Earthing rod
30
-
-
Painting of Pole with Red Oxide, Al. Paint & Post office Paint
30
-
-
Interlocking of base in transformer area
180
-
-
Glanular Sub Base for laying of Interlocking Bricks
7.5
-
-
Toe Wall for Fencing
180
-
-
Clamp angle for Panel mounting support
30
-
-
Danger Board with clamp N/B
30
-
-
Number Plate with clamp N/B
30
-
-
Nut Bolt and washer
30
-
-
Reaparing of Plinth if required
15
-
-
Miscellaneous Lug, Clamp, Washer, Nut, Etc.
15
-
-