Central Reserve Police Force Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Central Reserve Police Force - CRPF Tender
Electrical and Electronics
Eprocure
Opening Date4 Nov 2024
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 24,011Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Operation And Maintenance Contract For Dg Sets
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CRPF_827100_2Tender No
B.V(GCNDA)24-WksDte-CCellNIT37Tender Authority
Central Reserve Police Force ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Carrying out Services and maintenance of 02 nos DG set 62.5/63 KVA Diesel engine with AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (i) Topping up new lubricating oil 15W/40 or as specified grade of approved make as per IS 13656 : 2014 (ii) Topping up new glycol based coolant or as specified 50/50 with operating range from 118°C to -37°C of approved make as per direction of engineer in charge. (iii) Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set as per direction of engineer in charge.
(iv) Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc. complete suitable for DG Set as per direction of engineer in charge.
(v) Supplying and erecting Air cleaner/Air filter element suitable for DG set as per direction of engineer in charge.
(Note :-Servicing of generators shall be done half-yearly or running/completion of 500 hrs., whichever earlier or as desired by Engineer-in-charge and maintenance shall be done as and when required)
12
-
-
... More
Carrying out Services and maintenance of 01 no DG set 125 KVA Diesel engine with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (i) Topping up new lubricating oil 15W/40 or as specified grade of approved make as per IS 13656 : 2014 (ii) Topping up new glycol based coolant or as specified 50/50 with operating range from 118°C to -37°C of approved make as per direction of engineer in charge. (iii) Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set as per direction of engineer in charge.
(iv) Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc. complete suitable for DG Set as per direction of engineer in charge.
(v) Supplying and erecting Air cleaner/Air filter element suitable for DG set as per direction of engineer in charge. (Note :-Servicing of generators shall be done half-yearly or running/completion of 500 hrs., whichever earlier or as desired by Engineer-in-charge and maintenance will be done as and when required)
12
-
-
... More
Carrying out Services and maintenance of 02 nos DG set 200 KVA Diesel engine with AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (i) Topping up new lubricating oil 15W/40 or as specified grade of approved make as per IS 13656 : 2014 (ii) Topping up new glycol based coolant or as specified 50/50 with operating range from 118°C to -37°C of approved make as per direction of engineer in charge. (iii) Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set as per direction of engineer in charge.
(iv) Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc. complete suitable for DG Set as per direction of engineer in charge.
(v) Supplying and erecting Air cleaner/Air filter element suitable for DG set as per direction of engineer in charge. (Note :-Servicing of generators shall be done half-yearly or running/completion of 500 hrs., whichever earlier or as desired by Engineer-in-charge and maintenance shall be done as and when required)
12
-
-
... More
Replacement of Damaged Fittings
-
-
-
... More
Replacement of Fuel tank of 01 No. 200 KVA DG Set at Adm Block.
1
-
-
... More
Installation/replacement of UPS Battery system at Adm Block Electric control panel.
1
-
-
... More
Body Painting of 125 KVA DG Set at STP-1.
1
-
-
... More
Replacement of Base frame of 125 KVA DG Set at STP-1.
1
-
-
... More
NOTE:- All items to be used in this work should be branded and ISI certified or CPWD approved list of material may be followed. If any make is not specified, decision of Engineer-in-charge shall be final and binding.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements