Central Institute Of Medicinal And Aromatic Plants Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Central Institute Of Medicinal And Aromatic Plants - CIMAP Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Mar 2022
Closing Date8 Apr 2022
Tender Amount₹ 29,43,940
Costs
EMD
₹ 58,879Document Cost
₹ 1,120Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CSIR_111018_1Bid Award Id
ViewTender No
68_48/839/2022-MP(Works)Tender Authority
Central Institute Of Medicinal And Aromatic Plants ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Capacity 10-11 TR (Packaged IDUs + Controllers) Complete
3
-
-
... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required.
-
-
-
... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
37
-
-
... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
37
-
-
... More
SITC of GSS Rectangular ducting (Class VIII Galvanised) with all component like GI sheets , duct support MS angles, nut bolts etc as per site requirements
-
-
-
... More
22 Gauge
110
-
-
... More
24 Gauge
160
-
-
... More
SITC of Duct Acoustic lining with 25 mm thick fiberglass covered with RP Tissue paper & perforated Alluminium sheet
40
-
-
... More
SITC of Duct Insulation with XLP 13mm thermal insulation
245
-
-
... More
SITC of Extruded Aluminium Powder coated supply/ return air Spot grilles
6
-
-
... More
SITC of MS Volume Control Damper
2.5
-
-
... More
SITC of Duct Damper
2
-
-
... More
SITC of Canvass connection (1 no per Unit)
3
-
-
... More
SITC of sand,Cement Plaster with Thermocol , wire mesh for exposed Duct open in Roof
270
-
-
... More
SITC of Slotted angle Cable tray for laying of pipes and cables for exposed piping only(Width 200mm / Hight of Tray wall 25mm)
60
-
-
... More
Flexible Pipe for condensate Drain from indoor unit to the nearest drain point as per site suitability.(40 mm hard PVC)
20
-
-
... More
Annual Maintenance contract (Comprehensive) of Variable Refrigerant Flow/Variable Refrigerant Volume air cooled units for 03 years after the date of defect liability period of one year from the date of commissioning. The work Includes Quarterly visit, unlimited complains attending as and when required, Variable Refrigerant Flow/Variable Refrigerant Volume air cooled units in proper functioning to maintain the cooling requirements. Nothing will be paid extra on any account during the AMC period
-
-
-
... More
1 st year CAMC
1
-
-
... More
2 nd year CAMC
1
-
-
... More
3 rd year CAMC
1
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
25
-
-
... More
Buy back and dismantling of old existing air conditioners water cooled voltas make plant 3X7.5 TR rating installed in institute premises. The existing air conditioners water cooled voltas make plant is in operational/functional condition. The firm has to dismantle, transport, and take back the existing Air conditioners from the installation place. A detailed item list is prepared and submitted by the firm to issue gate pass to take the materials outside the institute. Format will be given by concerned Engineer In charge towards issue of gate pass. Make good if any things occurs during dismantling (personal safety gears, machinery, lifts, special tools etc.). Nothing will be paid extra on any account. The firm may physically inspect and check the existing old water cooled AC plant before quoting the price. Buy Back is mandatory.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements