If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Central Electronics Limited - CEL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Aug 2024
Closing Date28 Aug 2024
Tender Amount₹ 2,19,69,213
Costs
EMD
₹ 4,39,384Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEL_204332_1Bid Award Id
ViewTender No
C-2(b)/RC/0910/0212/2024Tender Authority
Central Electronics Limited ViewPurchaser Address
-Website
http://http://www.celindia.co.in/drupal7/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Relay base plate complete with amphanols, code pins, fixing screws etc. suitable for Metal to Metal K-50 mini groups/ECRs of Siemens Make or functional equivalent of other makes. Note: Relay base plates, are to be procured from Relay manufacturer (OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's certificate is submitted. inspection by CONSIGNEE
420
-
-
Supply of Time Element Relay (Clockwork type) AG timer Siemens Make (No RSSK 30/0052) or GIC make or functional equivalent. Inspection By RDSO
20
-
-
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (AC Immunised-1) Siemens make (No. RSSK 30/0078-1) (Ref. IRS:S46/74 with Amd. 1 & firms specification). or functional equivalent without base plates. Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. Inspection By RDSO
80
-
-
Supply of QNA1 AC immunized relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS: 931A, IRS:S60, IRS:S34 & IRS:S23. Inspection By RDSO
40
-
-
Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding9the values Sb (Antimony) 0.2% maximum,Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. Inspection By Consignee
10
-
-
Lacing thread rolls, black, wax coated (100 mtrs). Inspection By Consignee
25
-
-
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.S A – 23741A Alt.4, S A-23745 Alt.5, S A – 23746, S A-23748 Alt.4 & S A-23756A Alt.3. Inspection By RDSO
4800
-
-
Supply of cartridge fuse block made of PBT as per RDSO Drg No S A-23748 Alt 4, S A-23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. Inspection By RDSO.
240
-
-
Supply of round head type non-deteriorating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity y. Inspection By RDSO
1000
-
-
Supply of Tik-tak, piano type switches,5 A (as per IS Specification). Inspection By Consignee
96
-
-
Supply of three pole plug and socket 5 Amp (as per IS Specification). Inspection By Consignee
96
-
-
Supply of Lamp 110V/24W, 2 Pin for Loc. Inspection By Consignee
200
-
-
Supply of Apparatus Case with godown locks with detachable handle on both the doors. Single Case as per Drg. No.SK 783-1 & 2 with latest alteration. Inspection By RITES
48
-
-
Supply of Apparatus Case with godown locks with detachable handle on both the doors. Half Case as per Drg. No.SK 783-1 & 2 with latest alteration. Half Case as per Drg. No.SK 783-1 & 2 with latest alteration. Inspection By RITES
48
-
-
Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815. Inspection By Consignee
218
-
-
Supply of Hand Cuff Locks/ Godrej Navtal lock with Three common keys. Inspection By Consignee
96
-
-
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. Inspection By Consignee
192
-
-
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti-rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. Inspection By Consignee
984
-
-
Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at Centre to view description from front. Material to be procured from RDSO approved firms only. Inspection By RDSO
3000
-
-
Supply of DIN Channel for the terminals 1 Mtrs each. Inspection By Consignee
60
-
-
Supply of End plates for modular terminal block. Inspection By Consignee
600
-
-
Supply of End Clamp for modular terminal block. Inspection By Consignee
600
-
-
Fuse terminal block with LED indication upto 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004. (without fuse). Inspection By Consignee
300
-
-
End plate for through terminal block with LED indication. Inspection By Consignee
600
-
-
Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A). Inspection By Consignee
4000
-
-
Shorting link insulated Grey in colour. Inspection By Consignee
125
-
-
Operating tool (operating tool, screw driver & stripper) as per AnnexureVII. Inspection By Consignee
15
-
-
Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of :1) Copper bond steel electrode 3 Mtr. long 17mm dia. with copper bonding thickness of min. 250micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. Inspection By RDSO
50
-
-
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. Inspection By RITES.
12000
-
-
Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C. Railways & the instructions of Rly engineer at site.
14
-
-
Termination of cable cores on ARA terminal/disconnecting links in the cable termination rack. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractors own material. The work shall be done as per instructions of Rly engineer at site
7680
-
-
Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tag blocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. (UnitNumbers=Jumper)
3200
-
-
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.
3440
-
-
Termination of cable cores on ARA terminal/fuse blocks, 8 w ay terminals block/ Wago terminal in the apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
6880
-
-
Fabrication and fixing of phenolic laminated sheet in location box by providing all fixtures as per Railway Dr awing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg. and arrangement similar to SK 783-1/2 with latest alterations & as per instructions of Rly engineer at site. Single Case
48
-
-
Fabrication and fixing of phenolic laminated sheet in location box by providing all fixtures as per Railway Dr awing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg. and arrangement similar to SK 783-1/2 with latest alterations & as per instructions of Rly engineer at site. Half Case
48
-
-
Excavation and Casting of Apparatus Case foundation with contractors Anchor Bolts, Cement, ballast and other materials as per instruction of site engineer. Single Case as per Drg. No.SK-748.
48
-
-
Excavation and Casting of Apparatus Case foundation with contractors Anchor Bolts, Cement, ballast and other materials as per instruction of site engineer. Half Case as per Drg. No.SK-747.
48
-
-
Erection of Apparatus Cases. This includes filling of location foundations with river bed sand/stone dust and plastering on top of the sand/stone dust. Single Case
48
-
-
Erection of Apparatus Cases. This includes filling of location foundations with river bed sand/stone dust and plastering on top of the sand/stone dust. Half Case.
48
-
-
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide alongside the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805
2500
-
-
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide alongside the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes co vering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be maden as per procedure. The work shall be done as per the extant practice on Central Railway ay and instructions of Railway ay Engineer at site. Drg. No. SK 805
1200
-
-
Cutting of all types of Roads/ platforms (except concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on Central Rly & instructions of Rly engineer at site. Drg. No. SK 807
192
-
-
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
192
-
-
Digging of trench 1.0 M deep from rail flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806
384
-
-
Laying of DWC/RCC pipes along with collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc.
12384
-
-
Laying of signaling/Power/Telecom cable of various cores/sizes in trenches.
189
-
-
Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under: - Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
80
-
-
Horizontal boring of cable duct of minimum 2.0 Mtr. depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site Engineer. Preparation of site for Horizontal boring shall be carried out in presence of Railway a y Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
1550
-
-
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railway. NOTE: - The paint and primer should be from M/s Asian paints Co. Ltd., The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint o ver one coat of primer. Apparatus Case Single case
48
-
-
Painting of two coats of synthetic enamel paint o ver one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railway ays. NOTE: - The paint and primer should be from M/s Asian paints Co. Ltd., The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint o ver one coat of primer. Apparatus Case Half case
48
-
-
Painting of two coats of synthetic enamel paint o ver one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-incharge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from M/s Asian paints Co. Ltd., The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. Axle Counter devices.
170
-
-
Lettering / Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes. Single case
48
-
-
Lettering / Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes. Half case
48
-
-
Installation of earth electrode assembly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete. (only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
190
-
-
Installation, wiring & testing / commissioning of Multi Section Digital Axle Counter's Central Unit/Evaluator/Processor for the section /at station including its associated all indoor equipment’s, indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply of required power cable of multi -strand10 Sq mm or more from power room to Central Evaluator, 2 core shielded cable of required size copper conductor as per IRS (S) 76/89(Amd.3) or IS 694/2010 with latest amendment as applicable with other accessories as per the instructions of Railway Engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable if an y form Panel Room to Axle Counter room /Relay room in DWC pipe with contractor's material / existing ladder.
170
-
-
Installation, wiring & testing / commissioning of Axle Counter's Reset Box of all types in Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay room to Reset Box in DWC pipe / existing ladder.
6
-
-
Installation, Fixing and wiring of track side Electronic Equipment of Axle counters including its battery& charger (if required), foundation and earthing as per OEM's technical requirement and specification associated Relays in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables on terminals/fuse blocks. Supply and making Axle counter Parameter History Cards, all activities as per standard practice and technical specifications.
170
-
-
Installation of complete assembly of track device/double rail contact unit for entry or exist with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through antirodent, anti-oxidnat & non-flame propagating type Double walled corrugated (DWC) pipe as pr RDSO/SPN/204/2011 Ver.1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and upto location/T rack side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embeded rubber pipe with clamp for protecting these cables at DP end. (Unit-Number=Per track device)
170
-
-
Installation of complete assembly of deflectors on either side of track device/double rail contact unit including drilling of required sizes holes on rails for fixing these.
170
-
-
Installation of unit Earth as per RDSO/SPN/197/Ver. I or latest, to construct earthing of /=1 ohm consisting of a. digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and all other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the relay room, Exothermic weld materials and tools & fixtures for the welding Copper tapes and electrodes shall be arranged by the contractor.
50
-
-
Patching work in old location box consisting 1) Digging of pit, cleaning of earth from all sides, breaking of seal of location boxes removal sand from location, marking of new cable holes 2) insertion of cable from ground 3) making place for cable termination in old location, shifting ARA, fuse etc after removal and termination including fixing of ARA. 4) Termination of cable in old location 5) Filling of sand and plastering to all sides upto 50mm below ground level.
6
-
-
Supply of Tool box complete with megger and multimeter along with other accessories as per Annexure. Inspection by consignee.
4
-
-
ELECTRICALLY OPERATED HEAVY DUTY IMPACT DRILL MACHINE SIZE -13 MM WITH VARIABLE SPEED WITH 5 MTS ELECTRIC CORD, Operating Voltage:220-240 V, Wattage :550-650 Watt, MAKE: BOSCH, Black & Decker, Cheston, HITACHI, Dewalt, Inspection By Consignee. Numbers 6
6
-
-
Supply & transportation of Concrete Earth enclosure as per drg. Inspection By Consignee.
48
-
-
Transporting and supply and installation of concrete (RCC) route indicators at intervals of 50 meters as per technical specification. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations, it shall be painted with RED colour. Inspection By Consignee
730
-
-
HDPE Pipe 110 mm Diameter, PE63, Class PN6, with confirming to IS4984 with ISI marked (or) Latest. Type test report from Central Govt./state Govt/ NABL / ILAC to be submitted at the time of supply GEM Id No: 5116877- 43443347933. Inspection By Consignee
1700
-
-