Central Drug Research Institute Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Central Drug Research Institute - CDRI Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date15 Sep 2023
Closing Date25 Sep 2023
Tender Amount₹ 33,84,166
Costs
EMD
₹ 67,683Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_CSIR_167814_1Bid Award Id
ViewTender No
2/06/2023-Engg.Tender Authority
Central Drug Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2)3x1.5 Sq.mm
300
-
-
3)2x2.5 Sq.mm
100
-
-
4)3x2.5 Sq.mm
300
-
-
5)2x4 Sq.mm
100
-
-
6)3x4Sq.mm
300
-
-
7)2x6 Sq.mm
100
-
-
8)3x6 Sq.mm
100
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required:
-
-
-
1)2 Pair
300
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required:
-
-
-
1) 20 mm.
100
-
-
2) 25 mm.
100
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
1)1 way 5/6 amps
100
-
-
2)1 way 15/16 amps
100
-
-
3)5 Pins Socket 5/6 amps
50
-
-
4)6 Pins 15/16 amps socket
50
-
-
5)Telephone socket outlet
10
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
10
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box including modular plate etc as required.
10
-
-
Supplying and fixing following size/modules.GI box along with modular base and cover plate for modular switches in recess etc as required.
-
-
-
a) 1 or 2 Module (75mmX75mm)
10
-
-
b) 3 Module (100mmX75mm)
10
-
-
c) 4 Module (125mmX75mm)
10
-
-
d) 6 Module (200mmX75mm)
20
-
-
e) 8 Module (125mmX125mm)
20
-
-
f) 12 Module (200mmX150mm)
20
-
-
Supplying and fixing following modular base and cover plate on existing modular metal boxes etc as required.
-
-
-
a) 1 or 2 Module
2
-
-
b) 3 Module
2
-
-
c) 4 Module
2
-
-
d) 6 Module
2
-
-
e) 8 Module
2
-
-
f) 12 Module
20
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
100
-
-
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
100
-
-
Supplying and fixing call bell suitable for single phase, 230Volt, 50Hz on the existing box excluding connections etc as required.
4
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
20
-
-
Numbering of ceiling fan/exhaust fan/ fluorescent fittings etc. as required.
100
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
-
-
-
a) Upto 450 mm sweep
2
-
-
b) 510 mm sweep
2
-
-
Extra for fixing the louvers/shutters completes with frame for exhaust fan of all sizes.
4
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
-
-
-
a)100 A, 16 KA,TPMCCB
1
-
-
b)125 A, 16 KA,TPMCCB
1
-
-
c)150 A, 16 KA,TPMCCB
1
-
-
d)200 A, 16 KA,TPMCCB
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
a) 12way, Double door
1
-
-
b) 16 way, Double door
1
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase
outlets are required.)
-
-
-
a) 4 way (4 + 12), Double door
1
-
-
b) 8 way (4 + 24), Double door
1
-
-
Supply and fixing 5 amps to 32 amps. rating 240/415 volts, ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
-
-
-
i) Single pole
10
-
-
ii)Single pole and neutral
4
-
-
iii) Triple pole
2
-
-
iv)Triple pole and neutral
2
-
-
Supply and fixing single pole blanking plate in the existing MCB D.B. complete etc. as required.
10
-
-
Supply and fixing following rating, double pole, 240 V isolator in the existing MCB D.B. complete with connections, testing and commissioning etc as required.
-
-
-
i) 40 amps.
1
-
-
ii) 63 amps.
1
-
-
Supply and fixing following rating, four pole, 415 V isolator in the existing MCB D.B. complete with connections, testing and commissioning etc as required.
-
-
-
i) 40 amps.
1
-
-
ii) 63 amps.
1
-
-
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
4
-
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing 20 A, 240 V SPN industrial socket outlet with 2 pole and earth, metal enclosed plug top along with 20A “C” curve SP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing 30 A, 415 V TPN industrial socket outlet with 4 pole and earth, metal enclosed plug top along with 30A “C” curve TP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
1
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required:
-
-
-
a)Upto 35 sq.mm
200
-
-
b)Above 35 sq.mm and up to 95 sq.mm
10
-
-
c)Above 95 sq.mm and up to 185 sq.mm
10
-
-
d)Above 185 sq.mm and up to 400 sq.mm
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 K V grade of following sizes on wall surface as required:
-
-
-
a) Upto 35 sq.mm (clamped with 1mm thick saddle)
100
-
-
b) Above 35 sq.mm and up to 95 sq.mm (clamped with 25x3mm MS flat clamp)
10
-
-
c) Above 95 sq.mm and up to 185 sq.mm (clamped with 25/40x3mm MS flat clamp)
10
-
-
d) Above 185 sq.mm and up to 400 sq.mm (clamped with 40x3mm MS flat clamp)
10
-
-
Supplying and making end termination with brass compression gland & heavy duty lugs for the following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grades as required:
-
-
-
a)3½ X 25 sq. mm (28mm)
2
-
-
b) 3½ X 35 sq. mm (32mm)
2
-
-
c) 3½ X 50 sq. mm (35 mm)
2
-
-
d) 3½ X 70 sq. mm (38mm)
2
-
-
e) 3½ X 95 sq. mm (45 mm)
2
-
-
f) 3½ X 120 sq. mm (45 mm)
2
-
-
g) 3½ X 150 sq. mm (50 mm)
2
-
-
h) 3½ X 185 sq. mm (57mm)
2
-
-
i) 3½ X 240 sq. mm (62mm)
2
-
-
j) 3½ X 300 sq. mm (70 mm)
2
-
-
k) 4 X 10 sq. mm (25 mm)
20
-
-
l) 4 X 16 sq. mm (28mm)
20
-
-
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
-
-
-
a) 3½ X 70 sq. mm
1
-
-
b) 3½ X 95 sq. mm
1
-
-
c) 3½ X 120 or 150 sq. mm
2
-
-
d) 3½ X 185 sq.
2
-
-
e) 3½ X 240 sq.
2
-
-
f) 3½ X 300 sq. mm
2
-
-
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering,lead up to 50 meter.
2
-
-
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter.
2
-
-
Supply, installation, testing and commissioning of following sizes , BEE 5 star rated, ceiling fan with brush less direct current(BLDC) motor, class of insulation:B, 3nos. blades, 30cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, air delivery minimum 215 CMM, 350RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, tempreture rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V,50Hz, single phase AC supply, earthing etc. complete as required:
-
-
-
a)1200 mm sweep
30
-
-
b)1400 mm sweep
30
-
-
Supply of 1.1KV grade, PVC insulated and PVC sheathed heavy duty aluminium conductor cables of following sizes etc as required:
-
-
-
a)4 x 10mm square
100
-
-
b)4x 16mm square
300
-
-
c) 3&1/2 x 25mm square
10
-
-
d)3&1/2 x 35mm square
10
-
-
e)3&1/2 x 50mm square
10
-
-
f)3&1/2 x 70mm square
10
-
-
g) 3&1/2 x 95mm square
10
-
-
h) 3&1/2 x 120mm square
10
-
-
i) 3&1/2 x 150mm square
10
-
-
j)3&1/2 x 185mm square
10
-
-
k) 3&1/2 x 240mm square
10
-
-
l) 3&1/2 x 300mm square
10
-
-
Dismantling of defective existing office light fixture or fan or point wiring and handing over the material to electrical section as required.
400
-
-
Dismantling of sub main wiring from the surface or reccessed , restoring the surface & handing over the materials to the electrical section, etc as required.
100
-
-
Dismantling of existing or defective old metal clad power switches, MCB enclosures, DB’s, after disconnection of cables / wires, restoring of walls and handing over the material to electrical section, etc as required.
10
-
-
Dismantling of various sizes of cable from the surfaces, restoring the surfaces & handing over the materials to electrical section, etc as required.
100
-
-
Supply & mounting of 3 or 4 pole, 63 Amps, 16KA, 415V MCCB on existing mild steel box or enclosure, etc as required.
4
-
-
Supply & fixing of sheet steel enclosure box for fixing of 63 or 100 or 125 or 160 or 200Amps 3 or 4 pole MCCBs etc as required.
4
-
-
Providing and fixing of 3mm phenolic laminated sheet/perspex sheet on existing metal board/box etc as required.
8000
-
-
Supply & laying of 6 SWG GI earth wire along with existing aluminium power cable including end termination with proper size of lugs etc as required.
400
-
-
Supply & installation of following type of energy efficient LED light fitting along with accessories and manpower, including dismantling of defective light fitting, etc as required:
-
-
-
a)9 or 10 Watt, 2feet stand alone industrial type aluminium extruded CW
200
-
-
b)18 or 20 Watt, 4feet stand alone industrial type aluminium extruded CW
800
-
-
c) 12 to 18 Watt, Slim down lighter (155 to to 210mm dia) CW
10
-
-
d) 36 Watt, 2FeetX2Feet Slim light CW
20
-
-
e) 40 or 45 Watt, Post top lantern CW
2
-
-
f) 90 Watt, street light CW
2
-
-
g) 50 to 70 Watt, street light CW flood light
4
-
-
Supply & fixing of following sizes of single phase, 230 volt, 50Hz metallic exhaust or fresh air fan, etc as required:
-
-
-
a)225 mm sweep
10
-
-
b)300 mm sweep
10
-
-
c)450 mm sweep
10
-
-
Drawing of CAT6 cable in the existing surface/ recessed steel/ PVC conduit as required.
100
-
-
Diesel tank work 30KL underground
-
-
-
a) Supply, installation, testing and commissioning of TLS 4B console with display for fuel monitoring level, tempreture and density, including ATG probe for fule: high and low level measurement, float kit, belden cable @50 Mtr (approx.) etc as required.
1
-
-
b) Pressure and manual pressure testing of existing 30KL underground diesel tank up to 5PSI for maximum 1 hours, which includes 2 mandays visit and execution of work in all respct etc as required.
1
-
-
Supply, installation, testing & commissioning of non-pressurized ETC based Solar water heating System of 500 LPD, having following technical specifications: (A) Inner Tank 304-L 2B, Inner Tank/End dish Thickness Minimum 0.7 mm, Tank Welding High quality TIG Welding, Insulation ≥40mm thick High density PUF insulation with uniform density of Minimum 36 kg/m3, Outer Cladding MS Pre Coated Sheet, Colour : Off Whit, Outer Cladding Thickness 0.45mm, End Caps MS Pre Coated Sheet, Colour : Black, Anode Protection Aluminum Alloy (Double Anode rod),(B)Type of Collector ETC (Evacuated Tube Collector), Three Layer Tubes (Cu-SS-AlN), No of ETC 30, ETC Size Ø58 x 2100 mm, Borosilicate glass 3.3 Triple layer - Material of Selective Absorber Coating, Absorption Layer -Stainless Steel, a) Metal insulation layer(Copper), b) Absorption layer(SS & Al-N-Al enameled mirror, c) Anti reflection layer (Al-N-Al),(C)Absorber Material High quality triple layered ETC, Absorbance Rate =94.5% (after coating); =93.5% (after evacuating),(D) Emission Rate =6% (after coating); =6.5% (after evacuating), Tube Length 58 mm and 2100 mm, Wall Thickness 0.6 mm,Vacuum Degree =3x10^-3 Pa, Pressure 0.4 MpA, (E) complete with accessories,monitoring & MS supporting structure, as required.
4
-
-
Providing & fixing tripple layer cold water tank of capacity 1000 litres along with following supporing structure of minimum hieght of 10 feet, as stated below:
-
-
-
a) Triple Layer 1000 Ltr Cold Water tank
2
-
-
b) Supporing Struture of Angle framing with minimum hieght of 10 Feet
200
-
-
Providing, fixing, jointing and testing in position the following heavy class (SDR-11) CPVc pipes rated to temperature of 85 Deg C for HWS/CWS conforming cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges & plugs etc. Threading, jointing, and making proper connections. Cost shall be inclusive of Fixing/supporting the pipes (& fittings) at wall/floor level supported by clamps, hangers etc, as per specification, as staed below:
-
-
-
a) 40 mm (Main Line terrace to Cold Water Tank)
160
-
-
b) 40 mm cold water tank to Solar water heater tank
100
-
-
Providing and fixing of 32 mm nitrle rubber insulation(19mm thickness ) on hot water supply, etc as required.
200
-
-
Providing and fixing brass ball valves with brass ball / stem, union / flange, washer, nuts & bolts, rated to temperature of 85 Deg C and tested to a pressure not less than 16 Kg/Sq.cm. Including covering with nitrile rubber insulation having protective coating against mechanical damage as per manufacturer’s specification, as stated below:
-
-
-
a) 40 mm dia
4
-
-
b) 32 mm dia
4
-
-
Providing and fixing brass 40 mm dia non return valves with union/flange, washer, nuts & bolts, rated to temperature of 85 Deg C and tested to a pressure not less than 16 Kg/Sqcm Including covering with nitrile rubber insulation having protective coating against mechanical damage as per manufacturer’s specification, etc as required.
4
-
-
Providing and fixing male/female thread connector (MTC/FTC) with union / flange, washer, nuts & bolts rated to temperature of 85 Deg C and tested to a pressure not less than 16 Kg/Sq.cm. Including covering with nitrile rubber insulation having protective coating against mechanical damage as per manufacturer’s specification, etc as required.
-
-
-
a) 40 mm dia
20
-
-
b) 32 mm dia
20
-
-
GST 18 % (already included in the items rate, please do not fill GST here)
1
-
-