Central Drug Research Institute Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Central Drug Research Institute - CDRI Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date3 Nov 2022
Closing Date14 Nov 2022
Tender Amount₹ 83,51,381 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SITC of 200TR water cooled screw chiller stand by for breeding unit of animal house at old CDRI campus
SITC of 200TR water cooled screw chiller stand by for breeding unit of animal house at old CDRI campus
SITC of 200TR water cooled screw chiller stand by for breeding unit of animal house at old CDRI campus.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,installation,testing and commissioning of split casing end suction and top discharge Centrifugal pumps of 900 USGPM and 15 meter head suction /delivery of 150/125 m.m. for circulating condenser water through the circuit, directly coupled to 20/15 HP/KW, 4 - pole SPDP type Sq. cage. Induction Motor,with efficiency class of IE3 as per IS 12615, suitable for operation on 415 ± 10% volts, 50 Hz, 3-phase, A. C. power supply complete with base for pump and motor, coupling,coupling gaurd, bronze impeller , Sleeve,SS shaft drain and all other accessories as required and ribbed neoprene vibration isolation pads with the P.C.C/cement concrete foundation of pumps and conforming to specification. -

1

-

-

... More
Supply,erection, testing and commsissioning of FRP cooling tower CTI certified of 200 CMH top discharge squire shaped Induced Draft counter flow with FRP cold water basin, corrosion resistant synthetic plastic parts, hot water distribution spray header,PVC film type fill with intigrated drift eliminators and louvers, low noise direct driven fan,TEFC fan motor, drift eliminator and other accessories as required,make up -quick fill arrangement, overflow and drain connection with necessary valves and suitable ladder ,access arrangement for cooling tower interior,steel supporting stucture,anti vibration mounting etc. and as per the specification for cooling required quantity of water from 37º C condenser outlet to less than 32º C at an ambient WB temperature of 28º C during mansoon.(total heat rejection capacity of C. Tower shall be minimum 200 TR at 28º C WBT.(Advance /Paharpur/ Mihir /Bell/Delta)

1

-

-

... More
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding valves ,strainers, gauges etc. adequetly supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.(Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.).

-

-

-

... More
200 mm dia 'C" Class

85

-

-

... More
150 mm dia 'C' Class

5

-

-

... More
125 mm dia "C"Class

5

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps,supports, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 gauge polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.(The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia)

-

-

-

... More
200 m.m. dia (with 75 mm thick insulation)

40

-

-

... More
150 m.m. dia (with 75 mm thick insulation)

5

-

-

... More
125 m.m. dia (with 50 mm thick insulation)

5

-

-

... More
Supplying, fixing, testing and commissioning of following valves,strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.

-

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water circulation where ever necessary for maintenance and flow control of the system.

-

-

-

... More
200 mm dia.

4

-

-

... More
150 mm dia.

2

-

-

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water circulation where ever necessary for balancing of water .

-

-

-

... More
200 m.m. dia (with 75 mm thick insulation)

1

-

-

... More
150 m.m. dia (with 75 mm thick insulation).

4

-

-

... More
125 m.m. dia (with 50 mm thick insulation)

1

-

-

... More
Supplying, fixing, testing and commissioning of following valves,gauges and strainers for condenser water circulation as per specifications-

-

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water circulation where ever necessary for maintenance and flow control of the system.

-

-

-

... More
200 mm dia

5

-

-

... More
150 mm dia

4

-

-

... More
125 mm dia

1

-

-

... More
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation where ever necessary and required for site.

-

-

-

... More
125m.m. dia

1

-

-

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with PN 16 pressure rating for condenser water circulation where ever necessary for balancing of water .

-

-

-

... More
200 mm

1

-

-

... More
Providing and fixing in position the industrial type pressure gauges where ever necessary with gun metal / brass valves complete as required.

4

-

-

... More
Providing & fixing in position the mercury in glass industrial type thermometers whereever necessary as required.

4

-

-

... More
Supplying, fixing, testing and commissioning of following POT STRAINER of 200 mm Ductile CI Body flanged ends with stainless steel strainer for hot/chilled water circulation where ever necessary as required.

1

-

-

... More
Design , fabrication ,supply and installation of BMS supported and CPRI approved cubical type dust 7 vermine proof (IP54) electrical panel made out of 16G CRCA sheet with 3 phase and neutral Aluminium bus bars of 1000 A with bus supports in suitable bus chamber and internal control / power wiring, interlocking, incoming of 1 No.1000 Amp,35KA, 4P MCCB with overload & shortcircuit protection, earth fault protection, metering 0-1200 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch, 1 set R.Y.B lamps with fuses,out going of 630A MCCB, 400A MCCB and suitable MCCB, indication lamps etc out going for chiller, one condenser pump,cooling tower with star delta starter and two spare panel. (Switch gear items will be L&T / Siemens make)

1

-

-

... More
Supply of 1.1 KV and PVC/XLPE insulated pvc sheathed steel armoured aluminium power cable of following sizes as required:-

-

-

-

... More
3.5 Core x 300 mm²

20

-

-

... More
3.5 Core x 240 mm²

15

-

-

... More
4 Core x 10 mm²

180

-

-

... More
Supply of control cable XLPE/PVC insulated PVC sheathed, steel aromoured multi core copper conductor control cable of following sizes-4 C X 1.5 Sq mm

90

-

-

... More
Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

250

-

-

... More
Above185 sq. mm and upto 400 sq. mm (clamped with 25x3mm MS flat clamp)

35

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

40

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends “ ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required...

90

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 240 sq. mm (62mm)

2

-

-

... More
3½ X 300 sq. mm (70mm)

2

-

-

... More
4 X 10 sq. mm (25mm)

8

-

-

... More
Providing and fixing of 25mmx5mm GI strip on surface or in recess for earth connection etc. Complete as required.

90

-

-

... More
Comprehensive annual maintenance contract for the chiller and all other accessories included in the scope of work, after completion of the defect liability period of one year.

1

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

2.25

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers.

20

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

260

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

490

-

-

... More
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.

27

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work

20

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior,sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm.

15

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior,sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.

45

-

-

... More
GST @ 18% (included in the item rates)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.