Bundelkhand University Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Bundelkhand University Tender

Works
Eprocure
Opening Date11 Aug 2018
Closing Date17 Aug 2018
Tender Amount₹ 4,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Constructing brick masonry chamber/ manhole for underground CI inspection chamber and bends with bricks in CM 1:4 CI cover with frame light duty 455x610mm internal dimensions, total wt of cover with frame should not be less than 38 kg (Wt of cover 23 kg & wt of frame 15 kg) RCC top slab with 1:2:4, foundation concrete 1:5:10, inside plastering12mm tk in 1:3CM finished with 3mm tk floating coat of neat cement on walls & bed concrete etc complete as per std design.(Inside dimensions 455x610x450mm for single pipe line).

9

-

-

... More
P/f 110 mm dia PVC pipe 6 kg/sqcm pressure ISI marked (KISAN/FINOLEX) with specials such as bends, tee, socket, cross, clamps (300x25x3mm) and fixed to wall with 15 cm long 6mm dia nails and testing for leakage, finished good to wall including s/o all material, labour, T&P etc. reqd for proper completion of work.

155.2

-

-

... More
E/W in excavation in foundation in soil mixed with mooram / shingle kankar / gravel, including 1.50m lift and lead up to 30m including filling watering ramming of excavated earth in to the space between the bldg and side of foundation trenches or in to the plinth and removal & disposal of surplus earth as directed EI within the distance of 60m (rates are including royalty)

140.5

-

-

... More
As in item no 4 but for 160mm dia PVC pipe line.

100.4

-

-

... More
P/l 40 mm tk CC 1:2:4 flooring in cement, appd coarse sand, 20 mm stone grit laid in panels with 3 mm tk floating coat of neat cement including s/o all material, labour, T&P etc. reqd for proper completion of work.

153.36

-

-

... More
P/l PCC 1:4:8 in cement, appd coarse sand, 40 mm stone grit in foundation and under floors including s/o all material, labour, T&P etc. reqd for proper completion of work.

12.27

-

-

... More
Making connection of drain or sewer line with existing manhole i/c breaking into and making good the walls, floor with cc 1:2:4, 12mm CP on both side in 1:3CM finished with 3 mm tk floating coat of neat cement and making necessary channels for the drain etc complete.(For pipe 100-250mm dia)

9

-

-

... More
Add to item no 1 but for every addl lead of 30m or a part of addl lift up to 1.50m.

2388.5

-

-

... More
Septic tank work

-

-

-

... More
E/W in excavation in foundation in soil mixed with mooram / shingle kankar / gravel, including 1.50m lift and lead up to 30m including filling watering ramming of excavated earth in to the space between the bldg and side of foundation trenches or in to the plinth and removal & disposal of surplus earth as directed EI within the distance of 60m (rates are including royalty)

20.92

-

-

... More
P/l PCC 1:4:8 in cement, appd coarse sand, 40 mm stone grit in foundation and under floors including s/o all material, labour, T&P etc. reqd for proper completion of work.

1.39

-

-

... More
Ist class brick work in 1:4 cement mortars of cement and sand 1.25 FM in f&p including s/o all material, labour, T&P etc. reqd for proper completion of work.

6.58

-

-

... More
20 mm thick CP in 1:2 CM on BW on fair faces or in dado/skirting finished with 3 mm tk floating coat of neat cement including s/o all material, labour, T&P etc. reqd for proper completion of work.

30.15

-

-

... More
P/l 40 mm tk CC 1:2:4 flooring in cement, appd coarse sand, 20 mm stone grit laid in panels with 3 mm tk floating coat of neat cement including s/o all material, labour, T&P etc. reqd for proper completion of work.

4.5

-

-

... More
Cast CC door sills / b.posts / shelves / chaukhats or in similar works in 1:2:4 in cement, appd coarse sand, 20mm stone grit excluding s/o reinforcement and its binding, but including its fixing with 24 BWG GI binding wire and including necessary centering and shuttering including s/o all material, labour, T&P etc. reqd for proper completion of work.

0.68

-

-

... More
P/f 110 mm dia PVC pipe 6 kg/sqcm pressure ISI marked (KISAN/FINOLEX) with specials such as bends, tee, socket, cross, clamps (300x25x3mm) and fixed to wall with 15 cm long 6mm dia nails and testing for leakage, finished good to wall including s/o all material, labour, T&P etc. reqd for proper completion of work.

15

-

-

... More
Cleaning of manhole /lines with the help of sweepers their broom and reqd t&p complete in all respects.

8

-

-

... More
Making connection of drain or sewer line with existing manhole i/c breaking into and making good the walls, floor with cc 1:2:4, 12mm CP on both side in 1:3CM finished with 3 mm tk floating coat of neat cement and making necessary channels for the drain etc complete.(For pipe 100-250mm dia)

8

-

-

... More
P/f 110mm dia PVC cowl on top of septic tank complete in all respects.

1

-

-

... More
MS or Iron in plain work such as RCC/RB when not included in over all rates wrought to reqd shape as necessary including cutting, bending, binding the steel for proper completion of the work including wastage & over lapping and hooks.

0.43

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.