If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Bharat Sanchar Nigam Limited - BSNL Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date1 Jan 2025
Closing Date19 Jan 2025
Tender AmountRefer Documents
Costs
EMD
₹ 49,244Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Sitc Of 1 X 180 Kva Ea Set With Sound Proof Enclosure At
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_222154_1Tender No
09/ATC/GEM/BED/VNSTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bsnl.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
[c] Standard Manual Control Panel - Standard Manual Control Panel comprising of 1 No. 4 Pole, 400A MCCB with Overload & Short-circuit Protection having breaking capacity not less than 50 KA at 415 V with no-voltage release ,And Digital multi-display meter for current ,voltage, frequency ,power factor and power etc, with necessary CTs and indicating LED lamps, With SCR/SMPS type 10A,12 V ( in case of 12V starting system)/10A , 24V( in case of 24V starting system) inbuilt static battery charger with automatic trickle and boost charging and auto cutoff facility etc as per detailed specifications attached.
-
-
-
... More
[d] ACOUSTIC ENCLOSURE- Prefabricated factory built, free standing, floor mounting type acoustic enclosure of modular construction suitable for accommodating the 180 KVA Engine Alternator set with standard control/ instrument panel, fuel tank etc as per specifications and conditions attached. The engine and the enclosure shall conform to the latest environment (Protection) Act 1986(29 of 1986) of Ministry of Environment and Forest Notification No. dated 17th May 2002 and 12th July 2004 and 2nd Amendment of 2002 and 2004 respectively and Environment (Protection) (Third Amendment) Rules, 2014 dt 31st March 2014 and 11th Nov. 2014, in respect of noise and emission norms, as amended up-to-date. No set shall be accepted without the latest CPCB certificate of authorized agency such as ARAI of Pune, NPL New Delhi, NSTL Vishakhapatnam, FCRI Palghat and NAL Bangalore. The make and model number of Engine and alternator shall be as per BSNL approved product Directory.
-
-
-
... More
[e] I.T.C. of 180KVA DG Set- Installation Testing and Commissioning of the above 180 KVA E/A set with acoustic enclosure and control panel with all equipments, accessories and associated items on the cement concrete floor / foundation including providing necessary fuel MS piping and conducting Acceptance Testing of the Engine Alternator by arranging necessary consumables like Lube oil, fuel oil ,providing artificial resistive load with cabling ,switching arrangements etc. for pre Acceptance Testing ( i.e, 2 hours full load, 1 hour 10% overload and 1 hour at no load) and final Acceptance Testing of E/A set (i.e. Running of E/A set on full load for 6 hours and running on 10% overload for 1 hour) including topping up of lube oil up to full mark and filling of extra fuel up to a level suitable for 2 hours full load working etc. as per specifications as required.
-
-
-
... More
[f] PCC Foundation-Earth work in excavation in foundation including dressing of sides and ramming of bottoms, getting out the excavated soil and disposal of surplus excavated soil as directed etc as reqd. and after that providing suitable PCC plinth with ratio 1:2:4 (1cement:2coarse sand:4stone ballast aggregate 20 mm nominal size) for installing the engine alternator set in canopy i/c plastering, cementing, curing and shuttering etc as required.( Plinth size:- length 5.0m x breadth 2.0 m x height 1.0m. Above ground level plinth shall 0.4 meter high )
-
-
-
... More
(g) Earthing -Providing 04 set earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt and supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode-20 mtr ,and providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode--30 Mtr including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
-
-
-
... More
(h)-Supply & laying of cable in ground -Supply and Laying of one number heavy duty PVC insulated, armored cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminum conductor having insulation of PVC compound type -C, suitable for rated voltage up to and including 1100 volts and conforming to IS: 1554 (Part-1) latest. For 3-Phase Power Generators, 3.5 core x 240 sqmm size 10 meter cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
-
-
-
... More
(i) Supply and Laying on surface /existing cable tray of 1 No. cable of ISI marked heavy duty PVC insulated, Armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminum conductor having insulation of PVC compound type -C, suitable for rated Voltage up to and including 1100 volts and conforming to IS- 1554 (Part-1) latest. For 3-Phase Power Generators, 3.5 core x 240 sqmm size -04 Mtr complete as required. (Note-This shall be extra length of LT Cable required for connecting DG Set supply to existing MV Panel ,over and above the Length of LT Cable to be supplied by Seller as per GTR details given).
-
-
-
... More
(j) Providing nosing on all edges of PCC plinth using angle iron of size 50x50x5 mm i/c cutting, welding, painting etc complete as required.—18 Mtrs.
-
-
-
... More
(k) Supplying and making end termination of 3½ X 240 sq. mm with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.-04 sets.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%