Bharat Sanchar Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Bharat Sanchar Nigam Limited - BSNL Tender
Telecommunication Services
Eprocure
Opening Date21 Dec 2024
Closing Date1 Jan 2025
Tender Amount₹ 22,06,435
Costs
EMD
₹ 44,129Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_840952_1Bid Award Id
ViewTender No
25/NIT/EE(E)/BSNL/ED/MT/24-25Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://www.bsnl.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(b) More than than 25 KM from the District head quarter
150
-
-
... More
Charging of Refrigerant gas R-22 /R-32/410 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e. One complete air conditioning circuit only. (a) 1.5 TR
100
-
-
... More
(b) 2.0 TR
25
-
-
... More
Replacement of the following items/accessories in the existing WAC/SP AC/water cooler Units of all makes in place of faulty/unserviceable parts i/c dismantling of the faulty, fixing the new item and testing, connection etc. complete as reqd. (a) 120-140 MFD Starting Capacitor aluminum case
50
-
-
... More
40/50 MFD Running Capacitor aluminum case
50
-
-
... More
4MFD Fan Motor Capacitor aluminum case
50
-
-
... More
WAC Blower /WAC/condenser fan blade
50
-
-
... More
Starting relay
50
-
-
... More
PCB for Split AC 1.5 TR/2TR
25
-
-
... More
PCB for inverter type Split AC Indoor Unit
25
-
-
... More
PCB for inverter type Split AC 1.5 TR-For Out door Unit
25
-
-
... More
S/F of Blower/Condenser fan motor for 1.5 / 2 TR Window/Split A.C/water cooler unit in lieu of unservisible motor i/c connection etc as required.
40
-
-
... More
Provision of Top up of R-22/R-32 /410 gas in existing all type Window A.C /Split A.C/ units, flushing, testing etc. as required.
10
-
-
... More
P/F 12mm thick Exterior grade particle board for AC Unit for support i/c fixing the same with screw ,complete etc. as reqd.
2
-
-
... More
Replacement of the 1.5 TR rotary type compressor I/c dismantling of the existing compressor from site, to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required.
Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
20
-
-
... More
Replacement of the 1.5 TR Reciprocating type compressor I/c dismantling of the existing compressor from site, to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required.
Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
3
-
-
... More
S/F of following item in exsiting MV panel /MCB DB /free cooling i/c dismentling of faulty unit (if reqd ) i/c ,connections, testing etc comp as reqd. (a) 5 A to 32 A , 240/415 V, 10 kA, "C" curve, SP MCB
50
-
-
... More
b) 5 A to 32 A , 240/415 V, 10 kA, "C" curve, TP MCB
50
-
-
... More
c) 5 A Plug Top
50
-
-
... More
d) 15 A Plug Top
50
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
50
-
-
... More
Installation, Testing & Commissioning of the following type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall behind indoor unit , laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 3 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required. (a) 1.5/2 TR Split AC unit
5
-
-
... More
(b) 2x1.5/2 TR HSHF AC unit
3
-
-
... More
Pdg and Fixing of following size additional following size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured ) (a) 1/4"&5/8"
20
-
-
... More
(b) 3/8"&5/8"
5
-
-
... More
S/F of 50 mm dia PVC pipe for wall crossing of refrigerant and drain pipe of split AC units etc as reqd.
50
-
-
... More
S/F of 19 mm dia PVC Wire braded pipe for drain water of SPAC i/c fixing on wall surface with suitable MS shaddle etc.as te reqd.
50
-
-
... More
S/F Powder coated MS stand, for wall /Floor mounting of outdoor unit of Split AC i/c fixin gthe same on wall with suitable fastner etc as reqd
5
-
-
... More
Supplying and fixing of following size of white colour flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd (Note--Cables have joints shall be replaced to avoid fire hazard) (a) 3x1.5 sq mm
50
-
-
... More
3x2.5 sq mm
50
-
-
... More
Insulating the existing laid refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle etc as reqd
10
-
-
... More
Dismantling of the existing split /window type AC Unit complete with indoor unit, outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd .
10
-
-
... More
Dismantling of the existing 2x1.5/2 TR HSHF type Split AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to other room in same exchange premises ,packing of SPAC wall hole ,making good the damage etc as reqd .
3
-
-
... More
Installation of existing 1.5/2 TR Reciprocating /rotary type comressor in the all type AC units i/c connecting with existing refrigerent pipeline i/c vacuemising , nitrogen pressure testing ,etc as reqd
3
-
-
... More
Closing of existing window in AC opening area to prevent AC leakage/theft by Single brick masnoary i/c plastering with cement mortar , finishing etc complete as reqd as reqd.
1
-
-
... More
Transportation of Split /Window AC units/water cooler with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board ,stand from One TE building to various TE /BTS sites in BAMeerut i/c. loading,unloading etc. as reqd.