Bhadohi Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Bhadohi Industrial Development Authority Tender
Eprocure
Opening Date1 Mar 2019
Closing Date11 Mar 2019
Tender Amount₹ 39,53,049
Costs
EMD
₹ 3,95,305Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_BIDA_326532_1Bid Award Id
ViewTender No
BIDA/TECHNICAL-2/1701/19Tender Authority
Bhadohi Industrial Development Authority ViewPurchaser Address
-Website
http://www.bidabhadohi.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
FLOOR PANEL -2 Incoming- 630A, 4P, MCCB = 01 No Bus Bar- 630A, 415V, 50 Hz TPN Aluminium Busbar Outgoing- 400 A, TP, MCCB = 02 No 40 A, TP, MCB, 10 KA = 01 No 40 A, TP, MCB, 10 KA = 01 No 32 A, TP, MCB, 10 KA = 23 No
1
-
262140
... More
SUB FLOOR PANEL -1 Incoming- 200A, 4P, MCCB = 01 No Bus Bar- 200A, 415V, 50 Hz TPN Aluminium Busbar Outgoing- 63 A, TP, MCB, 10 KA = 01 No 40 A, TP, MCB, 10 KA = 01 No 32 A, TP, MCB, 10 KA = 17 No
1
-
92147
... More
SUB FLOOR PANEL -2 Incoming- 400A, 4P, MCCB = 01 No Bus Bar- 400A, 415V, 50 Hz TPN Aluminium Busbar Outgoing- 63 A, TP, MCB, 10 KA = 01 No 40 A, TP, MCB, 10 KA = 01 No 32 A, TP, MCB, 10 KA = 33 No
1
-
149194
... More
CAPACITOR PANEL SITC APFC panel of 100 KVAR capacity suitable for operation on 415 +5% Volts, 3 Phase, 50 Hz, AC supply, having MNP type, resin bounded, static 12.5 KVAR capacitors (Without oil) in tier formation complete with following TPN MCCB as incomer of the Panel, 8 steps microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors, for each capacitors protected with MCB's, Ammeter wit CT, Voltmeter selector switches indicating lights, cooling fans for panel, earting the panel with 2 nos 25x5 mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 Core Aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as required. te panel should have provision of timer based circuit in APFC relay to switc ON and OFF the static part automatically as and when required. Capacity of Static capacitors should be accomodated from the overall rating of the panel and should be designed to switch in independently . The panel should be fabricated with 1.6mm thick CRCA sheet duly powder coated. Incoming- 320 A, 4P, MCCB = 01 No Bus Bar- 400 A, 415V, 50 Hz TPN Aluminium Busbar Outgoing- 40 A, TP, MCB, 10 KA = 8 No
2
-
205357
... More
Main LT Panel Supply & Erection of factory fabricated & wired metal claddust and vermin proof floor mounting, MS Channel Base with bottom and top cable entries Electrical control panel TPN ACB ( 25KA, 4 pole MDO, Microprocesser release ) and TPN MCCB's ( Four Pole 25 KA wit thermal magnetic release) Switches and instrument chamberetc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeters, volt meter, selector switchs for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable cpacity electrilytic aluminium busbar as per IS8623 insulated with heat shrink and mounted in non hygroscopic supports such as CMC/DMC support with diteachable side covers and shall be complete with suitable for extension on side. The switches entry boxes shall be complete with cable end boxes reverse. All outgoings of 100 Amp and above will be provided with Amp meter, current transformer and selector switch etc and instrument switch. The board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. (Switchgear L&T, ABB, Siemens, Schneider) 1- Incoming- 800A, 4P, MDO ACB (25KA) = 02 Nos 2- Both the incomer will Electrically & Mechanically interlocked with 800A, 4P, MDO ACB (25KA) Bus Coupler. 3-Outgoing- 320 A, TP, MCCB = 03 No 500 A, TP, MCCB = 01 No 200 A, TP, MCCB = 02 No 125 A, TP, MCCB = 01 No 630 A, TP, MCCB = 03 No 300 A, DP, MCCB = 01 No 400 A, TP, MCCB = 02 No 63 A, TP, MCB = 01 No
1
-
1061660
... More
Supply and wiring of submains with 4 nos. 6.00 sq mm & with 2 no earth wire of 4.0 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. ( cable make- Havells, Polycab, Finolex )
2500
-
297
... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
1
-
-
... More
240 sq. mm 3-1/2 core
100
-
1209
... More
185 sq. mm 3-1/2 core
60
-
970
... More
70 sq. mm 3-1/2 core
100
-
443
... More
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.
1
-
-
... More
240 sq. mm 3-1/2 core
4
-
473
... More
185 sq. mm 3-1/2 core
8
-
397
... More
70 sq. mm 3-1/2 core
4
-
199
... More
Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.
1
-
-
... More
240 sq mm
4
-
272
... More
185 sqmm
8
-
193
... More
70 sqmm
4
-
67
... More
Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. ( havells, bajaj, phillips)
98
-
1870
... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required
-
-
-
... More
300mmx50mmx1.6mm
80
-
521
... More
600mmx50mmx2.0mm
20
-
641
... More
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing
6
-
5350
... More
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect
100
-
90
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements