Bareilly Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Bareilly Development Authority - BDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date1 Mar 2023
Closing Date28 Mar 2023
Tender Amount₹ 7,83,42,550 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 X 4 sq. mm +1 X 4 sq. mm earth wire(in minimum 20mm)( As per DSR_E&M _2022_1.14.3) (Rate=334/1.12)

4538

1353296

298.21

... More
2 X 6 sq. mm +1 X 6 sq. mm earth wire(in minimum 25mm)( As per DSR_E&M _2022_1.14.4) (Rate=439/1.12)

150

58794

391.96

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire(in minimum 32mm)( As per DSR_E&M _2022_1.14.9) (Rate=754/1.12)

210

141375

673.21

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire(in minimum 40mm)( As per DSR_E&M _2022_1.14.10) (Rate=1005/1.12)

250

224330

897.32

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm( As per DSR_E&M _2022_1.17.3) (Rate=95/1.12)

1566

132830

84.82

... More
3 x 2.5 sq. mm( As per DSR_E&M _2022_1.17.12) (Rate=137/1.12)

1250

152901

122.32

... More
3 x 4 sq. mm( As per DSR_E&M _2022_1.17.21) (Rate=206/1.12)

3157

580662

183.93

... More
3 x 6 sq. mm( As per DSR_E&M _2022_1.17.30) (Rate=304/1.12)

250

67857

271.43

... More
1 x 16 sq. mm( As per MR_A1) (Rate=390/1.18)

225

74364

330.51

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm( As per DSR_E&M _2022_1.21.1) (Rate=128/1.12)

1800

205714

114.29

... More
25 mm( As per DSR_E&M _2022_1.21.2)(Rate=145/1.12)

3500

453125

129.46

... More
32 mm( As per DSR_E&M _2022_1.21.3) (Rate=184/1.12)

250

41071

164.29

... More
40 mm( As per DSR_E&M _2022_1.21.4) (Rate=228/1.12)

100

20357

203.57

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep( As per DSR_E&M _2022_1.22.2) (Rate=209/1.12)

20

3732

186.61

... More
150 mm X 150 mm X 60 mm deep( As per DSR_E&M _2022_1.22.4) (Rate=311/1.12)

25

6941

277.68

... More
200 mm X 250 mm X 60 mm deep( As per DSR_E&M _2022_1.22.9) (Rate=468/1.12)

20

8357

417.86

... More
250 mm X 300 mm X 60 mm deep( As per DSR_E&M _2022_1.22.15) (Rate=607/1.12)

10

5419

541.96

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. ( As per DSR_E&M _2022_1.26) (Rate=40/1.12)

20

714

35.71

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.( As per DSR_E&M _2022_1.31) (Rate=477/1.12)

229

97529

425.89

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in Labs).( As per DSR_E&M _2022_1.56) (Rate=676/1.12)

10

6035

603.57

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( As per DSR_E&M _2022_1.32) (Rate=586/1.12)

74

38717

523.21

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. ( As per DSR_E&M _2022_1.25) (Rate=369/1.12)

89

29322

329.46

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet ( As per DSR_E&M _2022_1.24.7) (Rate=148/1.12)

7

925

132.14

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm X 75mm)( As per DSR_E&M _2022_1.27.1) (Rate=298/1.12)

7

1862

266.07

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. ( As per DSR_E&M _2022_1.57) (Rate=727/1.12)

10

6491

649.11

... More
Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. ( As per DSR_E&M _2022_1.38) (Rate=99/1.12)

8

707

88.39

... More
SUB-HEAD-II: DISTRIBUTION BOARDS Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door ( As per DSR_E&M _2022_2.3.3) (Rate=2315/1.12)

1

2066

2066.96

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way (4 + 18), Double door( As per DSR_E&M _2022_2.4.2) (Rate=4974/1.12)

40

177642

4441.07

... More
8 way (4 + 24), Double door( As per DSR_E&M _2022_2.4.3) (Rate=5967/1.12)

13

69259

5327.68

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole( As per DSR_E&M _2022_2.10.1) (Rate=256/1.12)

605

138285

228.57

... More
Triple pole( As per DSR_E&M _2022_2.10.4) (Rate=1007/1.12)

18

16183

899.11

... More
Supplying and fixing 63 A TP rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (As per MR-B3) (Rate=1234/1.18)

18

18823

1045.76

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. ( As per DSR_E&M _2022_2.11) (Rate=13/1.12)

121

1404

11.61

... More
Supplying and fixing following rating, double pole, 240 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A( As per DSR_E&M _2022_2.10.3) (Rate=656/1.12)

1

585

585.71

... More
Supplying and fixing following rating, four pole, 415 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A(As per MR-B5) (Rate=825/1.18)

40

27966

699.15

... More
63A(As per MR-B6) (Rate=1479/1.18)

13

16294

1253.39

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A( As per DSR_E&M _2022_2.14.1) (Rate=2028/1.12)

1

1810

1810.71

... More
40A( As per DSR_E&M _2022_2.14.2) (Rate=2642/1.12)

119

280712

2358.93

... More
63A( As per DSR_E&M _2022_2.14.3) (Rate=2722/1.12)

40

97214

2430.36

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. For 10 way, Double door SPN MCBDB( As per DSR_E&M _2022_2.23.3) (Rate=810/1.12)

1

723

723.21

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 6 way, Double door TPN MCBDB (As per DSR_E&M _2022_2.24.2) (Rate=1124/1.12)

40

40142

1003.57

... More
For 8 way, Double door TPN MCBDB(As per DSR_E&M _2022_2.24.3) (Rate=1340/1.12)

13

15553

1196.43

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (As per DSR_E&M _2022_2.18) (Rate=1621/1.12)

5

7236

1447.32

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(As per DSR_E&M _2022_2.19) (Rate=2590/1.12)

5

11562

2312.5

... More
Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:30, IK 08) minimum 1.2mm thick sheet steel DP/TP/FP MCB/ Isolator enclosure conforming to IS: 8623-1 & 3 & IEC 61439- 1&3, made out of pre-treated and powder coated (minimum 60-80 micron), 240/415 V, mount on surface / recess, complete with din bar including earthing stud etc. as standard or as suggested by Architect/Consultant. (But without MCB/RCCB/Isolator). (As per MR-B7) (Rate=386/1.18)

10

3271

327.12

... More
SUB-HEAD-III: LIGHTNING CONDUCTOR Supply, fixing, testing and commissioning of single spike air terminals of 10 mm dia.of 1Meter long as required and as per site conditions. the air terminal shall be manufactured with aluminium. The terminal shall be provided with the integrated / attached threaded base support suitable for mounting the terminals as per site condition. The base support shall be minimum 3 mm thick and shall have inbuilt connector fitting for connection of lightning conductor in such a way that conductor contact area shall not be less than 40mm on all side of the conductor as per IS/IEC 62305. (As per MR-C1) (Rate=2621/1.18)

6

13327

2221.19

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run) (As per DSR_E&M _2022_6.7) (Rate=126/1.12)

660

74250

112.5

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) (As per DSR_E&M _2022_6.8) (Rate=197/1.12)

176

30957

175.89

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required. (As per DSR_E&M _2022_6.4) (Rate=113/1.12)

278

28048

100.89

... More
Supply, fixing, testing and commissioning of Lightning counter indicating date and time of last record In-addition having to see previous history of surges etc complete as required to meet requirements to IS/IEC 62561-1 etc. complete as required. (As per MR-C2) (Rate=12500/1.18)

7

74152

10593.22

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. (As per DSR_E&M _2022_6.12) (Rate=121/1.12)

13

1404

108.04

... More
SUB-HEAD-IV: EARTHING SYSTEM Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(As per DSR_E&M _2022_5.4) (Rate=7472/1.12)

29

193471

6671.43

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. (As per DSR_E&M _2022_5.6) (Rate=13838/1.12)

9

111198

12355.36

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.(As per DSR_E&M _2022_5.10) (Rate=1551/1.12)

330

456991

1384.82

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (As per DSR_E&M _2022_5.11) (Rate=706/1.12)

286

180282

630.36

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (As per DSR_E&M _2022_5.15) (Rate=244/1.12)

231

50325

217.86

... More
Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required. (As per MR-D1) (Rate=143/1.18)

158

19147

121.19

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.(As per DSR_E&M _2022_5.16) (Rate=70/1.12)

1760

110000

62.5

... More
Providing and fixing 32 mm X 6 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (As per MR-D2) (Rate=291/1.18)

150

36991

246.61

... More
Providing and fixing 50 mm X 6 mm G.I. strip in 80 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.(As per MR-D3) (Rate=1126/1.18)

60

57254

954.24

... More
Providing and fixing 50 mm X 6 mm G.I.strip on surface or in recess for connections etc. as required.(As per MR-D4) (Rate=566/1.18)

30

14389

479.66

... More
Providing and fixing 40 mm X 6 mm Cu. strip in 80 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.(As per MR-D5) (Rate=1512/1.18)

40

51254

1281.36

... More
Providing and fixing 40 mm X 6 mm Cu..strip on surface or in recess for connections etc. as required.(As per MR-D6) (Rate=1321/1.18)

30

33584

1119.49

... More
SUB-HEAD-V: CABLE TRAY & RACEWAY CABLE TRAY Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness(As per DSR_E&M _2022_4.6.6) (Rate=1325/1.12)

33

39040

1183.04

... More
300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.6.4) (Rate=963/1.12)

259

222693

859.82

... More
150 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.6.2) (Rate=716/1.12)

220

140642

639.29

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness(As per DSR_E&M _2022_4.7.6) (Rate=2683/1.12)

6

14373

2395.54

... More
300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.7.4) (Rate=1852/1.12)

20

33071

1653.57

... More
150 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.7.2) (Rate=1270/1.12)

22

24946

1133.93

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness(As per DSR_E&M _2022_4.8.6) (Rate=3141/1.12)

1

2804

2804.46

... More
300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.8.4) (Rate=2156/1.12)

9

17325

1925

... More
150 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.8.2) (Rate=1383/1.12)

15

18522

1234.82

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness(As per DSR_E&M _2022_4.10.6) (Rate=3721/1.12)

4

13289

3322.32

... More
300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.10.4) (Rate=2823/1.12) Important Notes for raceways:- Contractor to get the samples of floor and ceiling raceways to be approved from the Architect/ Project Manager/ Consultant/ Client before supply & erection. Depth of the floor raceway is to be decided by the contractor after checking/ examining screed depth available at site. For this purpose chipping to be carried out at various places on the floor/ floors to carefully assess the depth/ floor margin available. Final approval is to be obtained from the Architect/ Project Manager/ Client before ordering/ fabricating raceway. The sizes & depths of raceways given in the BOQ are only tentative & indicative. Contractor is also supposed to check and confirm the adequacy of raceway sizes by calculating the exact number of electrical circuit wires & N/W wires for respective Electrical & N/W raceways.

9

22684

2520.54

... More
SUB-HEAD-VI: L.T./ CONTROL CABLES Supply of following sizes of Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments. 4 CORES 4 x 10 sq.mm. (As per MR-F1) (Rate=212.16/1.18)

650

116867

179.8

... More
3.5 CORES 3.5 x 50 sq.mm. (As per MR-F2) (Rate=502/1.18)

184

78277

425.42

... More
3.5 x 70 sq.mm. (As per MR-F3) (Rate=658/1.18)

322

179555

557.63

... More
3.5 x 95 sq.mm. (As per MR-F4) (Rate=822/1.18)

368

256352

696.61

... More
3.5 x 120 sq.mm. (As per MR-F5) (Rate=1023/1.18)

104

90162

866.95

... More
3.5 x 150 sq.mm. (As per MR-F6) (Rate=1191/1.18)

357

360327

1009.32

... More
3.5 x 185 sq.mm. (As per MR-F7) (Rate=1507/1.18)

196

250315

1277.12

... More
3.5 x 300 sq.mm. (As per MR-F8) (Rate=2335/1.18)

316

625305

1978.81

... More
Supply of following sizes of Power Cables multi stranded Copper conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments. 4 CORES 4x 4 sq.mm. (As per MR-F9) (Rate=341/1.18)

250

72245

288.98

... More
4x 6 sq.mm. (As per MR-F10) (Rate=496/1.18)

316

132827

420.34

... More
4x 10 sq.mm. (As per MR-F11) (Rate=747/1.18)

1144

724210

633.05

... More
4x 16 sq.mm. (As per MR-F12) (Rate=1095/1.18)

955

886207

927.97

... More
2 CORES 10 sq.mm. Cu Ar. XLPE cable(As per MR-F13) (Rate=434/1.18)

125

45974

367.8

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)(As per DSR_E&M _2022_7.8.1) (Rate=45/1.12)

2790

112098

40.18

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)(As per DSR_E&M _2022_7.8.2) (Rate=92/1.12)

506

41564

82.14

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm(As per DSR_E&M _2022_7.1.1) (Rate=387/1.12)

650

224598

345.54

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35mm)(As per DSR_E&M _2022_9.1.22) (Rate=413/1.12)

16

5900

368.75

... More
3½ X 70 sq. mm (38mm)(As per DSR_E&M _2022_9.1.23) (Rate=468/1.12)

8

3342

417.86

... More
3½ X 95 sq. mm (38mm)(As per DSR_E&M _2022_9.1.13) (Rate=542/1.12)

20

9678

483.93

... More
3½ X 120 sq. mm (45 mm)(As per DSR_E&M _2022_9.1.14) (Rate=597/1.12)

6

3198

533.04

... More
3½ X 150 sq. mm (50 mm)(As per DSR_E&M _2022_9.1.15) (Rate=681/1.12)

6

3648

608.04

... More
3½ X 185 sq. mm (57mm)(As per DSR_E&M _2022_9.1.16) (Rate=858/1.12)

10

7660

766.07

... More
3½ X 300 sq. mm (70mm)(As per DSR_E&M _2022_9.1.30) (Rate=1195/1.12)

8

8535

1066.96

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 2C X 10 sq. mm (19mm)(As per MR-F14) (Rate=247/1.18)

8

1674

209.32

... More
4C X 10 sq. mm (25mm)(As per MR-F15) (Rate=305/1.18)

60

15508

258.47

... More
4C X 4 sq. mm (25mm)(As per MR-F16) (Rate=251/1.18)

6

1276

212.71

... More
4C X 6 sq. mm (25mm)(As per MR-F17) (Rate=253/1.18)

16

3430

214.41

... More
4C X 16 sq. mm (28mm)(As per MR-F18) (Rate=370/1.18)

16

5016

313.56

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)(As per DSR_E&M _2022_14.16.1) (Rate=247/1.12)

15

3308

220.54

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)(As per DSR_E&M _2022_14.16.3) (Rate=368/1.12)

25

8214

328.57

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)(As per DSR_E&M _2022_14.16.4) (Rate=481/1.12)

40

17178

429.46

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)(As per DSR_E&M _2022_14.16.5) (Rate=668/1.12)

75

44732

596.43

... More
Supply of 11kV (E) 3 Core 185 sq. mm Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape (0.2kA for 1 sec/Core), cores laid up, innersheath/Outer of FRLS PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments.(As per MR-F19) (Rate=2453/1.18)

50

103940

2078.81

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 185 sq. mm and upto 400 sq. mm(As per DSR_E&M _2022_8.2.2) (Rate=415/1.12)

50

18526

370.54

... More
Supplying and making INDOOR cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required 185 sq. mm(As per MR-F20) (Rate=16217/1.18)

3

41229

13743.22

... More
SUB-HEAD-VII: SUPPLY OF LIGHT FIXTURES AND FANS Note:-The model numbers specified below are only for references for Shape of the product requirement. The product shall supplied, must match the technical specifications. The technical data sheets shall be arranged before the material dispatch and got approved from engineer-in- charge. Supply of PHILIPS DURA SLIM LED PANEL LIGHTS(MODEL NO. 59527) consuming a system wattage of 15W (±10%) & the luminaire shall be with system efficacy ≥ 105 lm / W. (As per MR-G1) (Rate=2122/1.18)

1521

2735222

1798.31

... More
Supply of PHILIPS DEEP COB RECESSED LED SPOTLIGHT consuming a system wattage of 12W (±10%) & the luminaire shall be with system efficacy ≥ 75 lm / W. (As per MR-G2) (Rate=2357/1.18)

480

958779

1997.46

... More
Supply of PHILIPS LINEABRIGHT LED COVE LIGHTING (MODEL NO. 582099) consuming a system wattage of 28W (±10%) & the luminaire shall be with system efficacy ≥ 500 lm /mt. (As per MR-G3) (Rate=2730/1.18)

300

694067

2313.56

... More
Supply of Recess mounted LED 2'x2' luminaire delivering an initial system lumen of 3300 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: CRCA, Rim: Engneering plastic / CRCA. Optics: polycarbonate/PMMA/Polysterene, IP20 Protection. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (As per MR-G4) (Rate=3947/1.18)

211

705777

3344.92

... More
Supply of Bulk Head Luminare delivering an initial system lumen of 700 lumens & the luminaire shall be with system efficacy ≥ 70 lm / W. Housing: Die Cast Aluminium. IP65 , Diffuser : OPAL Polycarbonate. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (As per MR-G5) (Rate=877/1.18)

29

21553

743.22

... More
Supply of 2ft Linear LED luminaire delivering an initial system lumen of 903 lumens & the luminaire shall be with system efficacy ≥ 90 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (Similar to Wipro Cat No.: LL20-111-XXX-65-NE or equivalent as per approved list of make)(As per MR-G6) (Rate=373/1.18)

10

3161

316.1

... More
Supply of 3W LED Unidirectional Exit Signage Light with inbuilt 2hours battery back up . (As per MR-G7) (Rate=4934/1.18)

22

91989

4181.36

... More
LED Flood light luminaire (IP66), BIS certified with a body of high pressure diecast aluminium, flat toughened glass protector (IK07) and a whitepolycarbonate film reflector around LEDs. Several optical options forsymmetric light distribution with 30°, 60° or 90° beam angles. Bracketsuitable for a wall, ground or high mast mounting and pre-cabled as required.Overall luminous efficiency of 120lm/W at correlated colour temperature(CCT) of 5700K (optional 3000K & 4000K), colour rendering index (CRI) 70and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internalsurge protection of 4/4 kV and an additional surge protection device (SPD) of10/10 kV from 100W and above (in both Common & Differential Modes).Offered Wattage - 100W, 120Lm/W Total Lummens - 12,000 (As per MR-G8) (Rate=11352/1.18)

16

153925

9620.34

... More
Decorative LED Up-Down Light, BIS certified with a grey painted die casted aluminium body and a PC lens sealed with the body to achieve complete IP66 protection and making the luminaire suitable for outdoor use.Surface-mounted luminaire for wall mounting.The optics of the luminaire shall be designed for two-sided light emission in both upward and downward directions. Design life shall not be less than 30,000 burning hours.Overall luminous efficiency of luminaire shall be 50Lm/W ± 7% at correlated colour temperature (CCT) of 3000K with tolerance as per ANSI standard, colour rendering index (CRI) 80. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.50 for 2W and 0.9 for 4W & 6W. Shall be supplied pre-cabled for easy installation.The product complies with the essential safety requirements of the applicable BIS standard. Offered Wattage - 6W 3000K. (As per MR-G9) (Rate=4057/1.18)

30

103144

3438.14

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (As per DSR_E&M _2022_19.1) (Rate=2730/1.12)

89

216937

2437.5

... More
Supply of 300mm dia sweep PVC body, 900±10% RPM Exhaust fan with guard and mounting arrangement. (As per MR-G11) (Rate=979/1.18)

15

12444

829.66

... More
Supply of 450mm dia sweep wall fan Hi speed with 3 speed push buttons, 1440 RPM, with guard and mounting arrangement. (As per MR-G12) (Rate=1624/1.18)

2

2752

1376.27

... More
Supplying, installation, testing and commissioning of Bollard light fitting suitable for 9 watt IP 65LED having system lumen output of minimum 900 lumens complete with all accessories and lamp. (As per MR-G13) (Rate=5969/1.18)

24

121403

5058.47

... More
Supplying, installation, testing and commissioning of Spike light fitting suitable for 9 watt IP 65 LED having system lumen output of minimum 900 lumens complete with all accessories and lamp. (As per MR-G14) (Rate=4537/1.18)

24

92277

3844.92

... More
Supplying of 4.0 and 6.0 mtr. long Polar pole Integrated with LED Modules, Clear polycarbonate optical cover, Protection class IP65, Integral power supply, Earth connection, Safety class I, Conformity mark, BIS - Conformity mark, Pole made of Mild Steel, Pole design parameters vary depending on the type of bracket and loading factor, All pole sections are welded using special v groove technique by certified welders using high end MIG welding processes, Built-in control box with service door including lock and safety chain, The control gear tray is prewired with MCB, terminal connectors for loop-in / loop-out arrangement, The foundation bolt holes in the base plate are designed to be elongated for fine adjustments / alignment of the pole during installation, Base plate made of steel grade E250 & foundation bolt of grade 4.6, including making cement concrete 1:2:4 foundation of minimum size as per manufacture design, including cost of 8mm dia steel rainforced bars for fixing of poles and providing and fixing 2 no 50mm dia DWC HDPE pipe of minimum one mtr long in side the foundation for laying of cables i/c providing and fixing bakelite sheet of size 25cm x 10cm x 6mm thick, 2 nos connector, of suitable size and complete with door and locking arrangement near bottom of the pole etc as required. K-Lite Polar 80-Series ID-KP-4862 / 4863, Arm-SA, Arm Length-600, Wattage-1 x 30W,Height-3000 / 4000, Mounting-KP-56.1/57.3 (As per MR-G15.1) (Rate=26767/1.18)

10

226838

22683.9

... More
K-Lite Polar 100-Series ID-KP-7229, Arm-SA, Arm Length-900, Wattage-1 x 60W,Height-6000, Mounting-KP-57.5(As per MR-G15.2) (Rate=29193/1.18)

18

445316

24739.83

... More
Providing, installation of 200 x 150 x 125 mm polycarbonate weather proof (IP-55) junction box and SP MCB’s and terminal block. Supplying and laying cable through GI pipe upto junction box including excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixture complete. (As per MR-G16) (Rate=3863/1.18)

8

26189

3273.73

... More
Wiring with 2 x 2.5 sq. mm. PVC insulated copper conductor 1100 V grade wires in existing pole including connecting at the lighting fixtures complete. (As per MR-G17) (Rate=135/1.18)

2500

286016

114.41

... More
Supply, installation, testing and commissionin of following polycarbonate weather proof (IP-55) junction boxes including terminal / connector block complete as required. One way (As per MR-G18.1) (Rate=1430/1.18)

5

6059

1211.86

... More
Two way (As per MR-G18.2) (Rate=1639/1.18)

7

9722

1388.98

... More
Three way (As per MR-G18.3) (Rate=1810/1.18)

10

15338

1533.9

... More
SUB-HEAD-VIII: INSTALLATIONS OF LIGHT FIXTURES AND FANS Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(As per DSR_E&M _2022_1.41) (Rate=206/1.12)

2367

435358

183.93

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (As per DSR_E&M _2022_1.45) (Rate=339/1.12)

89

26938

302.68

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep(As per DSR_E&M _2022_1.50.1) (Rate=450/1.12)

17

6830

401.79

... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. (As per DSR_E&M _2022_1.49) (Rate=57/1.12)

2708

137817

50.89

... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) (As per DSR_E&M _2022_1.47) (Rate=46/1.12)

89

3655

41.07

... More
SUB-HEAD-IX: UPS Supply, installation, testing and commissioning of 15kVA/ 12kW ( Input 3Phase / output 3 Phase) Floor Mount Type, Compact & modulat design, Conforming to IEC EN 62040 (All Parts), ISO 9001 certified, True On-Line, double conversion, IGBT on the input and output with multiple digital signal processor controlled for Rectifier/ charger, Battery, 2 Level IGBT Inverter, Static Switch, with parallel redundent, compatible with 0.7 lagging to 0.7 leading PF loads without deration, power factor 0.8, THDi 3-5%, Input voltage 380-415V, Output voltage 415V, 50Hz frequency, efficiency 95%, 0-40 deg C, with inbuilt overload, short circuit, Input low voltage, output over voltage, battery over charging, battery over discharging protections, Parallel kit, 30 min battery back-up with 12 V Maintenance Free Sealed Lead Acid batteries alongwith Powder Coated M.S. Rack with unidirectional wheels for housing the Batteries alongwith all accessories including interconnecting cables, lugs, Base Frames, Battery Rack & Battery Circuit breaker complete as required. (As per MR-I1) (Rate=285017/1.18)

2

483079

241539.83

... More
SUB-HEAD-X: DESIGN, FABRICATION, ASSEMBLING, SUPPLY, LOADING & FORWARDING TO SITE OF SUB-STATION EQUIPMENT SUBSTATION 11KV/433KV 11 KV HT DP STRUCTURE Supply, Installation, testing and commissioning of 11 kV DP structure as per CEI & MSEB norms & comprising of the following, but not limited to it for completion of works RSJ pole of 9.15 mt length of size 175 x 90 mm complete with suitable M.S. base plate welded at bottombase plate - 2 Nos. MS Channel of size 100 x 50 mm, length 4 mts (approx) 11 KV AB switch - 1 set 11 KV Horn Gap fuse Unit - 1 set 11 KV Lightning Arrestor 11 KV Disc insulator 11 KV Pin insulator 6 SWG copper wire for jumpering Supply and erection of Stay set complete with necessary foundation, excavation and refilling of earth etc. as required. Concrete foundation for RSJ poles burrioed upto a depth of 1830 mm in ground in a pit of size 450X450 mm in CC 1:3:6 along with 200 mm copping above ground inclusive of earth work. Necessary Nut, Bolts, clamps, operating handle for AB switch, clamping welding etc. complete as required. Painting the RSJ poles complete with two coat of Red Oxide and two coats of GI enamel paints complete as required. Transportation of all materials and accessories at site Complete erection, testing and commissioning. (As per MR-J1) (Rate=215625/1.18)

1

182733

182733.05

... More
11kV Single HT Panel Board. (In Indoor Cubical) Design, Manufacture, Supply at site, inspection of Consultant's/client at Factory at your cost of 11KV, 50Hz, in extensible type Indoor Cubical (IP 4X As per IS 3427:1969/IEC 298), free standing metal clad vaccum circuit breaker HT switchgear including suitable raiting protection relays, indications, push buttons, Toggle Switch copper busbars, Door earthed, Handle For breaker Spring Charging, etc. as per the requirement detailed in BOQ / SLD and engineer incharge etc. complete as required. The Panel shall be fabricated with CRCA sheet steel enclosure used for Side Sheet, Partition, removable Top/Bottom, Doors Sheet 2mm and 3mm for Removable Gland Plate & Base Frame. The Panel Shall be electro static powder coating paint (80-100 micron) with RAL 7035 Shade 630A, 11kV, 21kA for 3Sec., TP Electrically operated horizontal draw type Vacuum cicuit braker with, Auxilary contact minimum 4NO+4NC, 240V AC spring charge motor, trip free, dust & vermin proof, 24V DC Closing & Tripping Coil, Safety Shutter. Confirming to IEC 62271-100 Bus Bars- 60 x 10 Copper (3 Phase) + 30 x 6 Copper (Earth) OR EQ. Current Transformer - 3Nos. Epoxy resin cast double wound Single Phase CT for --- KVA Transformer. BIL : Suitable for Altitude of Less than 1000Meter, Core-1 :15 VA, Class 0.5 For Metering and Core- 2:15 VA, Class- 5P10 For protection. CT Ratio Potential transformers- 3Nos. Single Phase, Epoxy resin cast drawout type, PT Ratio 11KV / (Root 3) /110VAC / (Root 3) ratio class 0.5 accuracy, minimum 200 VA burden, feeder connected HV fuse on primary side and MCB on secondary side. 110Volts Tri-Vector Meter with Import/Export, Demand & RS485 Port Similar to Enersol make Model Number TVMR 5105 Class 0.5. IDMT self power relay with 3 elements for over current (50-200%) and 1 element for earth fault protection (10-40%) CDG-31 type. Anti pumping relay-VAA11, Master Trip relay-VAJH 13, Trip circuit supervision relay & Non Communicable Numercial relay for 50/ 51/ 50N/ 51N Restricted Earth fault relay. (For Transformer above 1500kVA) 3 Nos. Auxiliary relays for transformer faults WTI, OTI and Bucholz Relay. (For 800kVA and above Transformer) Power Pack Input - 110V AC, Output-24V DC with Battery back up of minimum 4 operation of circuit breaker. The Power pack shall connected on output of PT or Auxilary transformer shall be provided. A set of breaker ON / OFF / Trip / DC control supply / Trip circuit healthy / Spring Charged & R, Y, B phase indication LED lamps. Emergency trip push button Limit switches with 2NO + 2NC breaker auxiliary contacts Control:- T-N-C ( Trip, Neutral, Close ) breaker control switch with indication arrangement. 8 window annunciator with built in T/A/R, Auxilairy supply 24V DC, Case-2 D and hooter. (For 800kVA and above Transformer) make -Teknika/Minilec (2 Window for over Current & Earth fault) (2 Window for OTI alarm & Trip) (2 Window for WTI alarm & Trip) (2 Window Bucholz alarm & Trip) All control wiring with protection & test terminal block as required. The Control wiring sizes- 2.5 Sqmm, for Phases + Neutral + DC Control circuit + CT wire and PT Wire 1.5 Sqmm & Earth 4.0 Sqmm Cu Flexible. 100 Watts Strip heater, auxilary Supply - 110 Volts AC with thermostat range - minimum 02 - 105 Degree celsius Stem type for moisture absorption. Suitable for connection to 3C x 150sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. Danger Plate, LED bulb with holder connected to a toggle switch for each door open 11kV SINGLE PANEL BOARD - AS DESCRIBED ABOVE. (As per MR-J2) (Rate=508481/1.18)

1

430916

430916.1

... More
Supply, erection, testing and commissioning of 230V, single phase 2 wire AC to 24V DC Batteries charger with semiconductor/IGBT fullwave rectifier with auto /manual float cum boost facility complete with 24V DC, 120 AH sealed maintenance free batteries including one no. distribution board having 63 Amps DP MCCB as incomer and 12 Nos. 20/16A DP MCB's (D.C. duty) as outgoing complete as required and as per technical specifications. (As per MR-J3) (Rate=146733/1.18)

1

124350

124350

... More
SUB-HEAD-XI: TRANSFORMER-630 kVA 11/0.433kV ONAN OFF LOAD TAP CHANGER WITHOUT BUCHHOLZ, OTI AND WTI RELAYs Design, Manufacture, Supply at site, inspection of Consultant's/client at Factory at your cost of following rating continuous duty cycle, 11kV/0.433kV, 3 phase, 50Hz, Dyn-11 vector group, step down, outdoor type, copper wound, ONAN type transformers with off Load Tap changer & with all fixing accessories including complete as per specifications. Tap changing range shall be +5% to -10% in steps of 2.5%. Class 'A' of Thermal insulation Suitable for Maximum Ambient temperature 45º C. Maximum winding temprature 105º C The Following Fittings Shall Be provided with all required accessories:- Rating & Terminal Marking Plate, Earthing Terminals, Lifting Lugs For Main Tank & Top Cover, Filter Valve , Drain Cum Sampling Valve, Thermometer Pocket, Dial Type Oil Temperature Indicator, Air Release Plug, Silica Gel Breather, oil conservator, Explosion Vent, Inspection Cover, Arcing Horn, Radiators Mounted on Tank, 4 Nos. uni-directional Rollers, First Filling of Transformer Oil as per IS:335, Magnetic Oil Level Gauge, Marshalling Box, Epoxy Bushing, PU Paints, Palm, LV Bus Bar, Radiator Valves, Cable Box on LT side & Cable Box on HT side. Transformer shall Compliance to IS:1180 & IS:2026 all parts latest as on date whichever is higher. complete with all accessories The transformer shall be delivered along with after complete factory tests and temprature rise test, Operational & Maintenance manual and test certificate of unconditional guaranteed against manufacturing defects for a period of 18 months from the date of supply. i. 630kVA Losses as per IS:1180 Level-2(As per MR-K1) (Rate=1670725/1.18)

1

1415868

1415868.64

... More
Receiving, unloading & shifting to Sub-Station, storing, inspection of Consultant's/client at site, handling, installing in correct aligned position, on existing foundation, testing and commissioning of following rating, Transformers ONAN type with or without OLTC, RTCC Panel and AVR complete as required. 316-800kVA (As per MR-K2) (Rate=20200/1.18)

1

17118

17118.64

... More
SUB-HEAD-XII: MAIN LT PANEL/ SUB LT PANEL/ MDB & SDB Supplying, installation, testing & commissioning of Totally Type Tested Panels complying IEC 61439 -1/2 cubical with Internal arc withstand and impact resistance IK10 as per ICE62262. The panel shall be tested for an internal arc of 50kA for minimum 0.4 seconds. The degree of protection of minimum IP 42 for indoor and IP 65 for outdoor use. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of minimum 2 mm thick for load bearing member and 1.6mm for Non load bearing member, 3mm thick for gland, plates i/c cleaning & finishing complete, having extensible type aluminium bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA for 1 Sec., bottom frame shall be 100mm Height as per OEM standard, fabrication shall be done in transportable sections, Entire panel shall have a common aluminium earth bar of size 32mm x 6mm or as specified below at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al with form-4B construction. bus bars and control wiring with suitable size of PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- The Bus bars will be Copper purity 99.9% / electrolytic grade E91 Aluminium. Panels will be powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All Bus-Bar alley and relay compartments shall be provide fully automtic control thermotate with strip heater. Also, refer to General Notes and Specifications for Panels/ Boards. Contractor to submit manufacturer's Total discrimination curves prove the same, insulation material & corners cover on bus-bars for approval. Feeders should be totally bolted structure with interchangeable feeder.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC shrouds bus bar supports shall be used. Padlocking facility shall be provided on all MCCB feeder doors and switch handles shall be lockable in OFF position Sealing Arrangement :- PE Foam Rubber Gasket Bus Bars Supports - Non-Hygroscopic, Non Carbonising, Corrosion Resistant, SMC Supports 1Set of connector (Phase+Neutral) shall be provided in cable alley for all outgoing with interconnection wires between MCB and Connector. Minimum Air Clearances between bus bars shall be as per IEC 61439 Clause 8.2.5; Panel Power and control Wiring all ZHLS PVC insulated AC voltage circuit-1.5 sqmm Red,Yellow,Blue &Black Current circuit-1.5 sqmm Red,Yellow,Blue &Black AC Control circuit-1.5 sqmm White for Phase & Black for Neutral DC Control circuit-2.5 sqmm Grey Power circuit- Red,Yellow,Blue for Phase &Black for Neutral Labeling- Computerised Laminated Aluminium Name Plate with White letters on Blue/Black Background For Each Feeder and Panel Itself. NOTE: 1) If mentioned fault and Automatic transfer switch rating is unavailable consider nearby upside rating 2) A separate compartment for Minimum 20% spare space of Panel shall be provided for outgoings in future and busbars shall be drilled accordingly. 3) Total Discrimination of system shall be checked and required setting shall be made. If any component required to change will change free of cost. The switch-gear & Panel manufacturer (jointly) will submit discrimination check report duly checked and signed on company letter head. 1. GENERAL NOTES FOR ACB's: a. ACB shall be with 4 NO + 4 NC Auxiliary contacts .b. Safety Shutter. c. Door Sealing Frame. d. Inbuilt Ethernet Port e. Inbuilt TRIP LED indication. f. ON/ OFF/ TRIP status on Ethernet g. Ics = Icu = Icw for 1 sec. for the breakers. h. With built in micro-processor based releases: ( digitally upgradable) i. Adjustable over current with time setting. j. Adjustable short circuit with time setting. k. Instantaneous short circuit. l. Adjustable earth fault with time setting. m. Power wiring with one size higher terminals / bus bars for termination of cables as specified. n. There shall be no deration upto 50 degree celcius. o. ACBs shall be provided with both side terminal adaptors (Preferably Hr Vr) p. All the ACBs must be equipped with features like ZSI, Thermal Memory, last 10 trip histories, current & Voltage Metering, % loading Bar graph, LED fault differentiation, display of per phase energy & Total Harmonics Distortion 2. GENERAL NOTES FOR MCCB's: a. MCCB's shall be of TPN (3P with solid neutral link) or 4P as called for in the BOQ. b. Ics = Icu = 100% or more for the breakers. c. All Thermal Magnetic MCCB's shall have adjustable over current and Fixed short circuit if used as outgoing and when used as incomer short circuit rating shall be adjustable. d. All micro-processor based MCCB's shall have adjustable over current with time setting, adjustable short circuit and Adjustable earth fault with indication due to earth fault. e. MCCB's shall be with extended rotary handle with Phase spreaders & Phase Barriers at both sides f. MCCB's shall have auxiliary contacts for BMS compatibility. g. All MCCBs above 250A shall be microprocessor based. Thermal Magnetic MCCBs shall have modular external earth fault protection. h. All the MCCBs in Main Panel to communicate ON/OFF/TRIP status on Ethernet. 3. GENERAL NOTES FOR MCB's: a. MCB's shall be of minimum 10kA breaking capacity for 1 sec. b. Use 'B' curve MCB's for lighting & small power circuits, 'C' curve for motor duty i.e. for pumps, AC motors, AHU motors, window and split AC's etc. & 'D' curve for UPS DB's i.e. for computers/ PC's circuit. Main Incomer & outgoing circuit MCB's shall be selected accordingly i.e. type B,C & D. as per the nature of the circuit/ load. c. Exact MCB rating & category is to be calculated by the electrical contractor based on the final load of the circuit, its nature and fault current. (Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maxmum fault level of the panel.) 1. MAIN LT PANEL INCOMER FROM GENERATOR (DG SET-1 400 kVA ) Incomer from D.G. shall consist of the following: 1 No. 800Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. Under voltage & Overvoltage protection Overload, over current & Earth fault protection, Negative phase sequence protection relay , reverse power relay The MCCB shall be complete with 3 Nos. 250A/5A, 15VA, 5P10 CTs for protection. Metering, Indication & Push Button for Controls 3 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. 3 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 3 No. (0-800A) Ammeter with ASS with 3 nos. 250/5A CT's 3Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps. INCOMER FROM TRANSFORMER-1 630 KVA) Incomer shall consist of the following: 1 No. 1000Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. Under voltage & Overvoltage protection Overload, Over current & Earth fault protection Negative phase sequence protection,reverse power protection relay The MCCB shall be complete with 3 Nos. 400A/5A, 15VA, 5P10 CTs for protection. 3 set of 400/5A, 15 VA, class-1 CTs for APFC relay Metering & Indication 3 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. 3 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 3 No. (0- 1000A) Ammeter with ASS with 3 nos.1000/5A CT's 3 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps. INCOMER FROM GENERATOR (DG SET-2 250 kVA ) Incomer from D.G. shall consist of the following: 1 Nos. 400A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. Under voltage & Overvoltage protection Overload, over current & Earth fault protection, Negative phase sequence protection relay , reverse power relay The MCCB shall be complete with 3 Nos. 250A/5A, 15VA, 5P10 CTs for protection. Metering, Indication & Push Button for Controls 3 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. 3 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 3 No. (0-250A) Ammeter with ASS with 3 nos. 250/5A CT's 3Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps. BUS-COUPLAR 1 Nos. 1000A, 4 pole ACB BUS BARS I&II Sets of 1000A &600A TPN Aluminum bus bars with colour coded PVC sleeves PLC 1 no. 32-bit microprocessor based PLC with MMI for auto load Management of DG Sets, Sensing & Signaling AMF condition to PCC or equivaent mounted on DG Sets, Selection of Master DG Sets,operation(Opening/closing) as required BUSCOUPLER, Transformer incomers MCCB's interlocking etc as required and complete with interfacing with DG Set Control Module and coordination with Controller and DG Sets. Auto Load Sharing and Synchronization of DG Sets shall be Done by DG Controller PCC or equivalent mounted on DG Sets. OUTGOINGS( Short Ckt Rating in KA Rating as per above note ) 2 No. 630A TPN MCCB 3 No. 400A TPN MCCB 1 No. 250A TPN MCCB 2 No. 125A TPN MCCB 2 No. 100A TPN MCCB 3 No. 63A TPN MCCB 2 No. 63A TPN MCB 1 No. 40A TPN MCB Supplying,Receiving, fixing, testing & commissioning of above described main LT Panel. (As per MR_M1) (Rate=1670725/1.18) Note: Incomers for Transformer, D.G. sets & Bus couplers shall be electrically & mechanically interlocked and quoted price shall be inclusive of all .

1

1415868

1415868.64

... More
Capacitor Panel-1 (200 KVAR) INCOMER 1 No. 400 Amps TPN MCCB METERING & INDICATION 1 set of phase indicating lamps 1 No. Microprocessor APFC controller/Relay shall continuously monitor all three phases and LCD displays for various Electrical Parameters like voltage, input current, capacitive current, KVA demand,KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232 C port. Controller should mounted on the front side of the panel. BUS-BAR 1 Set of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 3 Nos.of 100A TP MCCB with suitable AC -3 duty contactor, 1 Nos.of 25A TP MCCB with suitable AC -3 duty contactor, 3 Nos.of 20A TP MCCB with suitable AC -3 duty contactor, 1 Nos.of 16A TP MCCB with suitable AC -3 duty contactor, 3 Nos. 50 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 1 Nos. 15 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 3 Nos. 10 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 1 Nos. 5 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. Note:The capacitor panel shall also stipulate the following (i) All the capacitors shall be suitable for 525 V (ii) Necessary control and firing card with proper wiring and lugs of the required rating to be provided. (iii) Heavy duty exhaust fans to be provided for cooling (iv) LED indication for number of capacitor banks ‘ON & Power Factor lagging or leading. (v) The APFC shall be protected from following * over-voltage & voltage unbalance * Over temperature-system should be in standby mode and automatically restart after above condition restored. * Total Harmonic Distortion Supplying,Receiving, fixing, testing & commissioning of Capacitor panel as described above of Capacitor panel as described above. (As Per MR_M2) (Rate=573858/1.18)

1

486320

486320.34

... More
FRONT OPERATED PANEL Design, manufacture, supplying fixing in position of the following front operated cubicle type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 25 MVA symmetrical at 415 volts. All switchboards shall be modular type and have provision for entry of cables from the top /bottom as required. The cost shall include providing and fixing of 100 x 50 x 6 mm channels for switchboard support. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. All MCCB shall have phase barriers, rotary handles and extension terminal as required . All unbalanced kWH meter shall have communication module for BMS connectivity MDB UPS Input panel-1 INCOMER 2 No.63 4P MCCB METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-125A) Ammeter with ASS with 3 nos. 320/5A CT's BUS-BAR 1 Set of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 2 No. 63A TPN MCCB Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M3) (Rate=181601/1.18)

1

153899

153899.15

... More
MDB UPS output panel INCOMER 2 No. 63A TP+2NL MCCB (25 kA) METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-125A) Ammeter with ASS with 3 nos. 160/5A CT's BUS-BAR 1 Set of 250A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 2 Nos. 63A TPN MCB 13 Nos. 40A TPN MCB Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M4) (Rate=334145/1.18)

1

283173

283173.73

... More
MDB-1 (FOR LIGHT & RAW POWER DISTRIBUTION) (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry. INCOMER 1 Nos.400A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class-1.0 accuracy for all incomer feeder. Refer to Cat no. - Trinity-NF29 E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer and outgoing MCCB TVSS AND BUS BARS 500 Amps TP+N, 35kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar. 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. OUTGOINGS( Short Ckt Rating in KA Rating as per above note ) 4 No. 160A TPN MCCB 3 No. 100A TPN MCCB, 3 No. 63A TPN MCCB, 4 No. 63A TPN MCB, 10 No. 40A TPN MCB Earth leakage protection relay with 30mA to 300mA with ZCT for each outgoing MCCB. Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M5) (Rate=799042/1.18)

1

677154

677154.24

... More
SDB-1,2 &3 (FOR LIGHT & RAW POWER DISTRIBUTION) . (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry. INCOMER 1 Nos. 160A TP+NL MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C & adjustable E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class-1.0 accuracy for all incomer feeder. Refer to Cat no. - Trinity-NF29 E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer and outgoing MCCB TVSS AND BUS BARS 250 Amps TP+N, 35kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar. 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.. OUTGOINGS( Short Ckt Rating in KA Rating as per above note ) 5 No. 63A TPN MCB 10 No. 40A TPN MCB Earth leakage protection relay with 30mA to 300mA with ZCT for each outgoing MCCB. Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M6) (Rate=319617/1.18)

3

812585

270861.86

... More
SDB-4 (FOR HVAC OUTDOOR) (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry.. INCOMER 1 Nos. 630A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class-1.0 accuracy for all incomer feeder. Refer to Cat no. - Trinity-NF29 E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer and outgoing MCCB TVSS AND BUS BARS 600 Amps TP+N, 35kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar. 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O... OUTGOINGS( Short Ckt Rating in KA Rating as per above note ) 14 No. 63A TPN MCB 3 No. 40A TPN MCB Earth leakage protection relay with 30mA to 300mA with ZCT for each outgoing MCCB. Supplying,Receiving, fixing, testing & commissioning of above described Panel . (As per MR_M7) (Rate=617442/1.18)

1

523255

523255.93

... More
METER BOARD PANELS-1&2 METER PANEL (Indoor use located at Ground floor on a plain civil foundation with cable entry from top and when wall mounted cable entry from Top/bottom or side wall as case may be) INCOMER 1 Nos. 125A TP+NL MCCB built in thermal magnetic based release (adjustable O/L & fixed S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with door Knob for door interlock with Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended INDICATIONS E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. BUS BARS WITH LOCK & KEY ARRANGEMENT 4x25x6 SQMM, 415 volts grade busbar chamber of suitable length with Aluminium busbars. All busbars and interconnections shall be of suitable size Al busbar, current density of bus-bars shall not be less than 1 Amps / sq.mm cross sectional area of Bus Bar. OUTGOINGS 12 Nos. 325MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Single phase pre-paid Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 40A, DP MCB with central overload trip mechanism and flag indication, 'C' Curve, 10kA with heavy duty 600V 4P terminal block screw type 60A in cable alley and power wiring between meter and connector via MCB. Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M8) (Rate=627611/1.18)

2

1063747

531873.73

... More
PLUMBING PANEL (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry. INCOMER 1 Nos. 63A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements A,V,Hz and RS-485 port for BMS with class-1.0 accuracy for all outgoing feeder. Refer to Cat no. - Trinity-VAF. E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer TVSS AND BUS BARS 100Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be with FRLS PVC insulated copper flexible colour coded wires, current density of bus-bars shall not be less than 1 Amps/sq.mm for Aluminium and 2 Amps/sq.mm for copper cross sectional area of Bus Bar. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.. OUTGOINGS Note:- All Starters shall be High Performance Star Delta / DOL Motor Starters as specified (Type 2 Co-ordination with MPCB at 415 V) 1 Sets of TP MPCB with inbuilt over load relay of 50kA breaking capacity each with 1.0HP DOL motor starter type ii co-ordination along with TP power contactors (AC3 Duty) with inbuilt 2NO + 2NC contact, Analouge Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP Fuse, Start/Stop Push buttons, Auto/Manual/off selector switch, 230Vac, 0-30Second and SPP Complete as required, for 2Nos. Water Transfer Pumps (1Working +1 Stand-by) 1 Set of TP MPCB with inbuilt over load relay of 50kA breaking capacity each with 1.0HP DOL motor starter type ii co-ordination along with TP power contactors (AC3 Duty) with inbuilt 2NO + 2NC contact, Analouge Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP Fuse, Start/Stop Push buttons, Auto/Manual/off selector switch, 230Vac, 0-30Second and SPP Complete as required, For 1No. Tube well pump. 1 Set of TP MPCB with inbuilt over load relay of 50 KA breaking capacity each with 10.0HP Star-Delta motor starter type ii co-ordination along with 3Nos. TP power contactors (AC3 Duty) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor, Analogue Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP HRC Fuse, Start/Stop Push buttons, Auto/Manual/off selector switch, Timer, 230Vac, 0-30Second and SPP Complete as required, For 2Nos. Filter Feed Pumps ( 1Working +1 Stand-by ) Provide Sequance Controller / Micro PLC in between starter feeders working and stand-by. The scheme for starting the pumps shall be such that only one Pump shall start at a time and the sequence of starting the pumps shall change regularly on daily basis and The pump shall srart on receiving the signal from pump controller 1 Nos. 63A TPN 'B' CURVE MCB with central overload trip mechanism and flag indication Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M9) (Rate=544802/1.18)

1

461696

461696.61

... More
FIRE FIGHTING PANEL (Indoor use located at Ground floor on a plain civil foundation with cable entry from top or Cable trench with bottom & top both cable entry) / Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry. INCOMER 1 Nos. 250A TP+NL MCCB built in microprocessor based release (adustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements A,V,Hz and RS-485 port for BMS with class-1.0 accuracy for all outgoing feeder. Refer to Cat no. - Trinity-VAF. E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer TVSS AND BUS BARS 300Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be with FRLS PVC insulated copper flexible colour coded wires, current density of bus-bars shall not be less than 1 Amps/sq.mm for Aluminium and 2 Amps/sq.mm for copper cross sectional area of Bus Bar. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. OUTGOINGS Note:- All Starters shall be High Performance Star Delta / DOL Motor Starters as specified (Type 2 Co-ordination with MPCB/MCCB at 415 V as specified in BOQ). Type 2 Co-ordination selection shall be in consideration of that the jockey pump motor should be minimum IE3 efficiency and rest other motors shall be of IE2 efficiency. 1 Set of TP MCCB (Motor duty) of 35kA with thermal over load relay each for 75HP Star-Delta motor starter type II co-ordination along with 3Nos. TP power contactors (AC3 Duty) with inbuilt 2NO + 2NC contact and necessary additional potantial free auxiliary contactor, CT operated digital Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP HRC Fuses, Start/Stop Push buttons, Auto/Manual/off selector switch, Timer, 230Vac, 0-30Secondand SPP Complete as required, For 1Nos. Main Hydrand Pumps 1 Set of TP MPCB of 50 KA with Thermal over load relay each for 7.5HP DOL motor starter type ii co-ordination along with TP power contactors (AC3Duty) with inbuilt 1NO + 1NC contact with necessary additional potantial free auxiliary contactor, CT operated digital Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP HRC Fuses, Start/Stop Push buttons, Auto/Manual/off selector switch,Timer, 230Vac, 0-30Secondand SPP Complete as required, For 1No. Jockey Pumps Provide fully automatic Diesel Engine starting panel complete with battary charger, Hooter, Anunciator window, Transformer, Rectifier, Ameter, Voltmeter, push butten, Relay, in side panel including control wirings etc. complete as required. Note:- CABEL CONNECTION Following provisions to be made in the fire panel: Audio visual alarm & indications having disconnect / reset facility with a range of 1/2 km. Annunciator to be provided in the Fire panel with hooter and acknowledge, test and reset P Bs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop. Facility for mode selection ie auto or manual test & local/remote. Protection failure & control cabling. Panel shall be interlocked in such a way when fire pump starts on pressure drop in the header, supply to working chiller A/c panel is disconnected. Remote indication of ON/OFF/TRIP shall be provided through potential free contact. Provision of remote starting/stopping (manuals) of the engine shall be made. NOTE : All pumps operation shall be controled by flow switches. The logic of control panel based on specification attached. All pumps shall be works automatically or manually. 5 Amp power required for diesel engine pump from main fire fighting panel. (panel starter shall be based on pumps motor rating if any changes in motor rating the starter rating shall change and fabrication shall start only after approval of drawing) Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M10) (Rate=602914/1.18)

1

510944

510944.07

... More
SDB - EXTERNAL LIGHT PANEL (Outdoor use located in external area on Rock or soft Soil as case may be with bottom cable entry.. INCOMER 1 Nos. 63A TP+NL MCCB built in thermal magnetic based release (adjustable O/L & fixed S/C) of fault breaking capacity 25KA (Ics=Icu=75%) upto 415V manually operated with door Knob for door interlock with Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended OR 1Nos. 63 4P 'C' Curve MCB with central overload trip mechanism and flag indication of 10kA breaking capacity 1Nos. 80 4P Power Contactor Main incomer with Auto/Manual selector and self Start/Stop illuminated switch. 1No. 1 Channel yearly programming cycle Astronomical time switches with in- built 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz, Hager make-EE181 or Eq. Make. 1No. 2 Channel yearly programming cycle Astronomical time switches with in- built 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz, Hager make-EE181 or Eq. Make. METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin Filled Nylon 66 Casing CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements A,V,Hz and RS-485 port for BMS with class-1.0 accuracy for all outgoing feeder. Refer to Cat no. - Trinity-VAF. E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Start/Stop illuminated push buttons, Auto/Manual/off selector switch 2P/2W+OFF, ON/OFF/TRIP indicator, Timer each backed up with HRC fuses provide on each power contactor. TVSS & BUSBARS SECTIONS 4x25x6 SQMM, 415volts grade busbar chamber of suitable length with Copper bus-bars mount on SMC supports current density of bus-bars shall not be less than 2 Amps/sq.mm for copper cross sectional area of Bus Bar. For interconnections provide 3 x 100A tinned copper insulated prong type short links with end cap , 4Nos. neutral bus bar (For three phase & One common), 3Nos earth bar, din bar as required. The cost shall include required minimum 10sqmm copper insulated colour coded interconnection wire set, circuit identification lables & laminated wiring detail chart as standard. 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.. OUTGOINGS: 15 Nos. 20A DP 'C' Curve MCB with central overload trip mechanism and flag indication of 10kA breaking capacity connected before timer used for Guard Room DB. All MCB shall be mounted on din channel inside closed chambers shall have Acrylic sheet infront and front door should be a glass for see thru. Supplying,Receiving, fixing, testing & commissioning of above described Panel. (As per MR_M11) (Rate=239713/1.18)

1

203146

203146.61

... More
SUB-HEAD-XIII: SAFETY EQUIPMENTS Supply and Erection of MS angle iron bucket stand which include 6 Nos. fire bucket with 9 ltr. Capacity with sand filling including cost of fabrication, welding and painting of complete stand & buckets with one coat of red oxide and two coats of approve paint of red color written with fire on the buckets as per fire protection with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. (As per MR_N1) (Rate=15327/1.18)

1

12988

12988.98

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 3mm thick, suitable for 11 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top). (As per MR_N2) (Rate=2295/1.18)

10

19449

1944.92

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2mm thick, suitable upto 3.3 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top). (As per MR_N3) (Rate=1990/1.18)

12

20237

1686.44

... More
Supply and fixing in position approved shock treatment chart written in English, Hindi and local language. These charts shall be framed in wooden frame and covered with clear glass. (As per MR_N4) (Rate=5157/1.18)

2

8740

4370.34

... More
Supply of First aid box as approved by St. John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963. (As per MR_N5) (Rate=5756/1.18)

1

4877

4877.97

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. (As per DSR_E&M _2022_2.21) (Rate=269/1.12)

6

1441

240.18

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. (As per DSR_E&M _2022_2.22) (Rate=292/1.12)

4

1042

260.71

... More
Supplying of Rubber gloves of 11 KV grade as per IS 4770-68. (As per MR_N6) (Rate=1288/1.18)

1

1091

1091.53

... More
Supplying and fixing of MS sheet board of size 500mm x 300mm of 16 SWG with 'Entry Restricted to Authorised Person Only" near the main entrance of the Sub- Station. The lettering shall be black painted on yellow base or as approved by engineer incharge. (As per MR_N7) (Rate=654/1.18)

1

554

554.24

... More
Supply and fixing safety instruction chart both in Hindi & English duly framed with 3 mm thick glass as required. (approximate front area 1.00 sq. Meter). (As per MR_N8) (Rate=5521/1.18)

1

4678

4678.81

... More
SUB-HEAD-XIV: FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. (As per DSR_E&M _2022_17.2.4) (Rate=2858/1.12)

454

1158510

2551.79

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (As per DSR_E&M _2022_17.2.9) (Rate=2726/1.12)

4

9735

2433.93

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. (As per DSR_E&M _2022_17.2.5) (Rate=276/1.12)

25

6160

246.43

... More
Supplying,installation,testing & commissioning of addressable manual call point complete as required. (As per DSR_E&M _2022_17.2.14) (Rate=3871/1.12)

18

62212

3456.25

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required. (As per DSR_E&M _2022_17.2.7) (Rate=3270/1.12)

28

81750

2919.64

... More
Supplying, installation, testing & commissioning of addressable fire Monitor modual complete with base as required.

9

26977

2997.46

... More
Supplying, installation, testing & commissioning of addressable fire control modual complete with base as required. (As per DSR_E&M _2022_17.2.10) (Rate=3003/1.12)

18

48262

2681.25

... More
Supplying, installation, testing & commissioning of addressable Relay module complete with base as required.

9

32987

3665.25

... More
Supplying,installation, testing & commissioning of addressable horne cum strobe complete as required. (As per DSR_E&M _2022_17.2.15) (Rate=3506/1.12)

18

56346

3130.36

... More
INTELLIGENT FIRE ALARM SYSTEM Supply , Installation , Testing and Commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. Designed to meet UL864, 10th Edition Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohm / Gamewell04 Loop (Rate as/Attached Quotation of LV System)

1

349220

349220.34

... More
REPEATER PANEL Supply , Installation , Testing and Commissioning of Network Repeater Panel with minimum 10" Color Touch Screen display with QWERTY Keypad, mapping minimum 2,00,000 points on network. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation. (rate as/Attached Quotation of LV System)

1

143368

143368.64

... More
SITc of Graphics User Interface for Monitoring & Control of complete Fire, Voice Evacuation & Telephone Talkback System. The GUI based main network software shall network with other panels on True Peer-to-Peer network. It shall be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems, and / or sensors’ locations. It shall have the facility to change the sensitivity of any detector. The software shall be capable of monitoring 200 Nodes with 100 Mbps Transmission rate on Fibre Optics Network and 12 Mbps Transmission on cable and 2,50,000 network points. The software shall be capable to Monitor & Control all the Digital Voice Evactuation as well as 2 way communication from main control room using voice signals over Fire Network along with the Fire detection signal. The Graphic workstation shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of GUI. Approved Makes :Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohm / Gamewell (rate as/Attached Quotation of LV System)

1

128389

128389.83

... More
Supply , Installation , Testing and Commissioning ofAddressable Fire Fighter's Telephone Jack with suitable supervised module for two way communication between Remote Fire Fighter & Fire Command Center. UL Listed. (rate as/Attached Quotation of LV System)

12

46220

3851.69

... More
Supply , Installation , Testing and Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center. (rate as/Attached Quotation of LV System)

2

25677

12838.98

... More
Supplying and Laying of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable. (rate as/Attached Quotation of LV System)

4428

397957

89.87

... More
SUB-HEAD-XV: PA SYSTEM Supplying, installation, testing & commissioning 2X250 W Class-D Amplifier with 1 independent channel and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. (rate as/Attached Quotation of LV System)

2

211864

105932.2

... More
PAGING STATION Supply, Installation, Testing & Commissioning of IP based Networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions: . Built-in monitoring loudspeaker . Detachable goose-neck microphone . LCD touchscreen display . Audio input (rate as/Attached Quotation of LV System)

1

55635

55635.59

... More
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. (As per DSR_E&M _2022_17.3.2) (Rate=965/1.12)

81

69790

861.61

... More
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. (As per DSR_E&M _2022_17.3.3) (Rate=1793/1.12)

81

129672

1600.89

... More
Supplying, installation, testing & commissioning command keypad 6 zone, with microphonecomplete as required. (As per DSR_E&M _2022_17.3.9) (Rate=81756/1.12)

1

72996

72996.43

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. (As per DSR_E&M _2022_17.5.1) (Rate=359/1.12)

651

208668

320.54

... More
SUB-HEAD-XVI: IT/ NETWORKING, & CCTV SYSTEM-ACTIVE & PASSIVE COMPONENT PASSIVE COMPONENT( STRUCTURED CABLING SYSTEM PASSIVE) Supply , Installation , Testing and commissioning of CAT 6 UTP cable 23 AWG solid copper conductors for Connectivity of Hub room to End Point. Approved Makes: Belden/Siemon/Panduit/Derwiser/ Rit (rate as/Attached Quotation of LV System)

8074

372909

46.19

... More
Supply, Installation, Testing & Commissioning of CAT6 information outlet (I/O) for Data, Voice, Wifi and Camera at user end. Approved Makes: Belden/Siemon/Panduit/Derwiser/ Rit (rate as/Attached Quotation of LV System)

232

59572

256.78

... More
Supply, Installation, Testing & Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end. (rate as/Attached Quotation of LV System)

13

107376

8259.75

... More
Supply, Installation, Testing & Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. (rate as/Attached Quotation of LV System)

232

59572

256.78

... More
Supply, Installation, Testing & Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity. (rate as/Attached Quotation of LV System)

232

64547

278.22

... More
Supply, Installation, Testing & Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. (rate as/Attached Quotation of LV System)

232

29786

128.39

... More
Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. (rate as/Attached Quotation of LV System)

1

52062

52062.12

... More
Supply, Installation, Testing & Commissioning of 15U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. (rate as/Attached Quotation of LV System)

3

32097

10699.15

... More
SECTION - II- IP-PBX SYSTEM Supply, Installation, Testing & Commissioning of Pure IP at core server Based voice solution with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,86 IP users License ,01 Nos. IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode. (rate as/Attached Quotation of LV System)

1

1032397

1032397.2

... More
Supply, Installation, Testing & Commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE . (rate as/Attached Quotation of LV System)

80

588881

7361.02

... More
Supply, Installation, Testing & Commissioning of Type 2 IP Phone with 2 Voip accounts, 2 Lines , HD Voice,Graphic LCD display with backligh. (rate as/Attached Quotation of LV System)

6

84737

14122.88

... More
SECTION - III- LOCAL AREA NETWORK ( LAN ) Supply , Installation , Testing and Commissioning of Core  Switch with switching capacity of 3.6Tbps with  48 x 1/10/25G with 8 x 40/100G QSFP28 ports  from day 1, dual hot swappable internal power supply. Should support advance layer 3 (OSPF, BGP and MPLS). 200k MAC address, 100K IPv4 routes and 100k IPv6 routes entries in the routing table with 48000 Multicast Routes, Switch OEM should be leader in Gartner data centre Quadrant. (rate as/Attached Quotation of LV System)

1

825974

825974.58

... More
Supply, Installation, Testing & Commissioning of of Access Switch 24 Port POE+ Access Switches with switching capacity of 128 Gbps, forwarding performance 95 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W and 4 x 10G SFP+ uplink ports, should have support for 9 switch Stacking with bandwidth of minimum 120 Gbps. Should support min 2GB internal DRAM, 2GB internal Flash memory, 32K MAC address, 4k Multicast Routes, Should have static Routing from day 1 and upgradable to support OSPF and VRRP with 1 year support. (rate as/Attached Quotation of LV System)

10

1947245

194724.58

... More
Supply, Installation, Testing & Commissioning of Appliance based customised ITAM for asset inventory management with ability to map physical locations and exact rack elevations for audit and support control. Appliance shall be Intel x86 based device with secure intranet server with Linux Based operating system and relational databases for long term storage. Appliance includes license for 100 units under control. (rate as/Attached Quotation of LV System)

1

826717

826717.54

... More
SECTION - IV- Wi-Fi SYSTEMS Supply, Installation, Testing & Commissioning of the Microservices based WLAN Architecture. The indoor AP should have radios to support 2.4Ghz and 5 Ghz band in a 4X4:4 Mu-MIMO configuration with support for 802.11 a/b/g/n/ac. The AP should have internal Omni Antennas and should support vBLE and RF optimization. It should also support way finding and asset tracking via bluetooth.Should support Artificial Intelligence platform, WIPS/WIDS to detct Rogue APs and the facility to terminate connevction to the Rogue APs.Plenum rated and support for UL 60950-1 CAN/CSAC22.2 No. 60950-1, FCC Part 15.247, 15.407, 15.107, and 15.109 RSS247 ICES003. (rate as/Attached Quotation of LV System)

7

340438

48634.07

... More
SUB-HEAD-XVII: IP CCTV SYSTEM Supply, installation, testing and commissioning of 5 MP Dome camera , ONVIF profile S , G& T ,UL , CE , FCC Certified ,1/2.8” Progressive Scan CMOS ,2.7 mm to 12 mm motorized varifocal lens , Quad stream with each stream support H.265+ compression simultaneously ,min illumination : 0.01 Lux @ (F1.2,AGC ON), 0 Lux with IR , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,120 dB WDR , Compression : H.265+ ,H.265 ,H.264+ H.264 .SD card support upto 128GB , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP ,Edge analytics : line crossing , perimeter intrusion ,Face detection(deep learning) , pedestrian detection ,cross counting , stationary object , In built IR LED , IR Distance upto 40 meters , IP 67 , IK10 ,POE. (rate as/Attached Quotation of LV System)

17

341944

20114.41

... More
Supply, installation, testing and commissioning of 5 MP Bullet camera , ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.8” Progressive Scan CMOS ,2.7 mm to 12 mm motorized varifocal lens , Quad stream with each stream support H.265+ compression simultaneously ,min illumination : 0.01 Lux @ (F1.2,AGC ON), 0 Lux with IR , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,120 dB WDR , Compression : H.265+ ,H.265 ,H.264+ H.264 .SD card support , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP , Edge analytics : line crossing , perimeter intrusion ,Face detection (deep learning) , pedestrian detection ,cross counting , stationary object , In built IR LED , IR Distance upto 50 meters , IP 67 , IK 10 housing , POE. (rate as/Attached Quotation of LV System)

20

419406

20970.34

... More
Supply, installation, testing and commissioning of 64 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA , Alarm in/out :16ch in / 4ch out , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support , each HDD slot support upto 8 TB HDD , RAID support , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR . Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000 ,A.I maximum captured quantity 200,000. . UL,CE,FCC certified. (rate as/Attached Quotation of LV System)

1

276173

276173.39

... More
Supply, Installation, Testing & Commissioning of 8TB Surviellance Hard Disk. (rate as/Attached Quotation of LV System)

4

97576

24394.07

... More
Supply, Installation, Testing and Commissioning of Full HD 55" LED Professional Display Panel. (rate as/Attached Quotation of LV System)

1

73182

73182.2

... More
Supply, Installation, Testing and Commissioning of 24 port L2 Managed switch having port density 24 Nos. of 10M/100M/1G RJ45 Port POE/POE+ ports , 4 Nos. of 1G/10G SFP+ Port , 1X console port , Available POE power 370 W , 128 Gbps switching bandwidth , 32K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP server , Device Management system - topology view , floor view , map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified (rate as/Attached Quotation of LV System)

3

584173

194724.58

... More
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest. (rate as/Attached Quotation of LV System)

1

96720

96720.34

... More
SUB-HEAD-XVIII: IT/ NETWORKING, & CCTV SYSTEM-CONDUTING Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm(As per DSR_E&M _2022_1.21.2) (Rate=145/1.12)

5119

662727

129.46

... More
PART-2 FIRE FIGHTING FIRE PROTECTION SYSTEM External Fire System Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. MS `C' Heavy class pipe 150 mm dia(As per DSR_E&M _2022_18.6.2) (Rate=3804/1.12)

185

628339

3396.43

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS: 904 as required: 2 way-100 mm dia M.S. Pipe(As per DSR_E&M _2022_18.19.1) (Rate=6742/1.12)

1

6019

6019.64

... More
4 way - 150 mm dia M.S. Pipe(As per DSR_E&M _2022_18.19.2) (Rate=13974/1.12)

2

24953

12476.79

... More
NON RISING cast Iron double flange SLUICE Valve as per 151/14846 PN 1.6 rating complete with Bronze body & wedge Stainless Steel spindle, G land packing, Rubber gasket.(As per MR-1) 150 mm dia (Rate=20515/1.18)

2

34771

17385.59

... More
Providing, fixing, testing & commissioning of indoor type hose lockable cabinet frames fabricated from 40 x 40 x 5 angle iron sections and 16 gauge MS sheet with full front glass door and locking arrangement, suitable to accommodate landing valves, 15 m long hoses, first-aid hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade, as required (Approx 2.1 m (high) x 0.9 m (wide). The item shall be complete of MS housing with front door. (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hamer). (As per MR-2) (Rate=6543.33/1.18)

1

5545

5545.19

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : single headed Stainless steel (As per DSR_E&M _2022_18.10.2) (Rate=6139/1.12)

8

43850

5481.25

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)(As per DSR_E&M _2022_18.16.2) (Rate=4448/1.12)

16

63542

3971.43

... More
Providing, fixing, testing & commissioning of butterfly valve (PN 1.6) (suitable for test pressure of 24 kg / sqcm) with flanges, nut bolts, gaskets, painting and necessary pad locking arrangement complete required. 65 mm dia(As per DSR_E&M _2022_18.11.3) (Rate=4302/1.12)

4

15364

3841.07

... More
80 mm dia(As per DSR_E&M _2022_18.11.4) (Rate=4982/1.12)

2

8896

4448.21

... More
100 mm dia(As per DSR_E&M _2022_18.11.5) (Rate=6667/1.12)

2

11905

5952.68

... More
150 mm dia(As per DSR_E&M _2022_18.11.6) (Rate=8960/1.12)

9

72000

8000

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. (As per DSR_E&M _2022_16.8) (Rate=1196/1.12)

2

2135

1067.86

... More
Providing, fixing, testing & commissioning of automatic Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1). (As per MR-3) (Rate=1990/1.18)

1

1686

1686.44

... More
Constructing masonry Chamber 60x60x75cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size) and inside plastering with cement mortat 1:3 ( 1cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (As per DSR_Civil _2021_18.33.1) (Rate=10102.5/1.12)

2

18040

9020.09

... More
Providing and fixing Fire Hose Cabinet made up of fully welded construction of size 750 x 600 x 250 mm, fabricated from 14 SWG GI sheet, having hinged double front door with locking arrangements and partially glazed with 5 mm thick glass. Cabinet must have Stove enamelled Fire Red finish with "FIRE HOSE" written on front and must be suitable for housing 2 Nos. 15m long synthetic Hose with couplings, 1 No. Branch Pipe, Fire Man Axe complete as specified in drawing. (As per MR-4) (Rate=5880/1.18)

8

39864

4983.05

... More
Fire Pumps And Equipments Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting For pump defined above & of duty as follows : Flow : 450 LPM (at terrace lvl.) Head : 35 mts(As per DSR_E&M _2022_18.4.2) (Rate=86203/1.12)

1

76966

76966.96

... More
Supply, installation, testing and commissioning of electrically driven high pressure centrifugal fire hydrant / sprinkler pump, suitable for automatic operation consisting of the following: Horizontal end suction / high pressure single, centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal, capable for delivering 2850 LPM at outlet head of 70 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority). Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ A.C supply, for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling and coupling guard, complete as required. c. Common base plate for (a) and (b) from M.S. Channel for required size. d. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with anti-vibration arrangement of cushy foot mountings.For pump defined above & of duty as follows : Flow : 1620 LPM Head : 70 mts(As per DSR_E&M _2022_18.1.8) (Rate=331972/1.12)

1

296403

296403.57

... More
Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date. Horizontal end suction / high pressure single / multistage, centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal, capable for delivering 1620 LPm at outlet head of 70 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority). Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. b. Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required. c. Common base plate for (a) and (b) from M.S. channel of required size. d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with antivibration arrangement of cushy foot mountings. For pump defined above & of duty as follows : Flow : 1620 LPM Head : 70 mts(As per DSR_E&M _2022_18.2.8) (Rate=592194/1.12)

1

528744

528744.64

... More
Supply, installation, testing and commissioning of jockey pump (pressurisation pump) comprising of the following: a. Vertical Multistage, centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with Flexible coupling and coupling guard, complete as required. Jockey pump shall be of stainless steel construction. The pump head and base shall be CI GG20 construction and impellers, diffusers, shaft sleeve, seal bush & pump shaft shall be in SS 304 material. The pump shall be provided with mechanical seal The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side (The pump should meet the condition and shall be gotten approved by the Local fire Authority). b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as required. c. Common base plate for (a) and (b) from M.S. channel as required size. d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting. For pump defined above & of duty as follows : comman jocky Flow : 180 LPM Head : 70 mts(As per DSR_E&M _2022_18.3.2) (Rate=103304/1.12)

1

92235

92235.71

... More
Providing, fixing, testing and commissioning of precharged air vessel (size 250 mm dia & 1200mm height) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required. (As per DSR_E&M _2022_18.20) (Rate=18244/1.12)

1

16289

16289.29

... More
Providing, fixing, testing & commissioning of automatic Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1).. (As per MR-3) (Rate=1990/1.18)

2

3372

1686.44

... More
Providing & fixing in position the industrial type pressure gauges with gun metal/ brass valves complete as required. (As per DSR_E&M _2022_16.8) (Rate=1196/1.12)

1

1067

1067.86

... More
Providing, fixing, testing & commissioning of forged brass ball valve with forged brass ball suitable for test pressure of not less than 37.5 kg / sq.cm of the following size with nuts, bolts, gaskets, necessary accessories, etc as required. (Cost shall be inclusive of providing necessary union / flange connection). 25 mm dia(As per MR-5) (Rate=1595/1.18)

10

13516

1351.69

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 65 mm dia(As per DSR_E&M _2022_18.11.3) (Rate=4302/1.12)

4

15364

3841.07

... More
80 mm dia(As per DSR_E&M _2022_18.11.4) (Rate=4982/1.12)

4

17792

4448.21

... More
100 mm dia(As per DSR_E&M _2022_18.11.5) (Rate=6667/1.12)

8

47621

5952.68

... More
150 mm dia(As per DSR_E&M _2022_18.11.6) (Rate=8960/1.12)

3

24000

8000

... More
Providing, fixing, testing and commissioning of dual plate C.I. wafer type check valve of pressure 37.5 Kg/sq.cm with flanges, Nut,bolts & washers, painting etc. complete as required. 65 mm dia(As per DSR_E&M _2022_18.14.3) (Rate=6418/1.12)

2

11460

5730.36

... More
100 mm dia(As per DSR_E&M _2022_18.14.5) (Rate=11050/1.12)

2

19732

9866.07

... More
150 mm dia(As per DSR_E&M _2022_18.14.7) (Rate=17786/1.12)

4

63521

15880.36

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia(As per DSR_E&M _2022_18.15.3) (Rate=11144/1.12)

2

19900

9950

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. For hydrent system - MS `C' Heavy class pipe 25 mm dia(As per DSR_E&M _2022_18.7.1) (Rate=744/1.12)

30

19928

664.29

... More
32 mm dia(As per DSR_E&M _2022_18.7.2) (Rate=851/1.12)

5

3799

759.82

... More
40 mm dia(As per DSR_E&M _2022_18.7.3) (Rate=1034/1.12)

5

4616

923.21

... More
50 mm dia(As per DSR_E&M _2022_18.7.4) (Rate=1281/1.12)

5

5718

1143.75

... More
65 mm dia(As per DSR_E&M _2022_18.7.5) (Rate=1614/1.12)

15

21616

1441.07

... More
80 mm dia(As per DSR_E&M _2022_18.7.6) (Rate=1885/1.12)

2

3366

1683.04

... More
100 mm dia(As per DSR_E&M _2022_18.7.7) (Rate=2555/1.12)

30

68437

2281.25

... More
150 mm dia(As per DSR_E&M _2022_18.7.8) (Rate=3574/1.12)

25

79776

3191.07

... More
200 mm dia(As per DSR_E&M _2022_18.7.9) (Rate=5463/1.12)

2

9755

4877.68

... More
INTERNAL FIRE SYSTEM Hydrants, Piping & Accessories Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and the supply of the same shall also be included in rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted. MS `C' Heavy class pipe 25 mm dia(As per DSR_E&M _2022_18.7.1) (Rate=744/1.12)

20

13285

664.29

... More
100 mm dia(As per DSR_E&M _2022_18.7.7) (Rate=2555/1.12)

107

244093

2281.25

... More
150 mm dia(As per DSR_E&M _2022_18.7.8) (Rate=3574/1.12)

20

63821

3191.07

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm dia(As per DSR_Civil_2021_18.18.3) (Rate=399.15/1.12)

10

3563

356.37

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia(As per DSR_E&M _2022_18.11.5) (Rate=6667/1.12)

4

23810

5952.68

... More
150 mm dia(As per DSR_E&M _2022_18.11.6) (Rate=8960/1.12)

6

48000

8000

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel(As per DSR_E&M _2022_18.9.2) (Rate=6139/1.12)

10

54812

5481.25

... More
Providing & fixing in position the industrial type pressure gauges with gun metal/ brass valves complete as required: (As per DSR_E&M _2022_16.8) (Rate=1196/1.12)

12

12814

1067.86

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. (As per DSR_E&M _2022_18.13) (Rate=1321/1.12)

14

16512

1179.46

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m Long. (As per DSR_E&M _2022_18.17.1) (Rate=8675/1.12)

10

77455

7745.54

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)(As per DSR_E&M _2022_18.16.2) (Rate=4448/1.12)

20

79428

3971.43

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)(As per DSR_E&M _2022_18.18.2) (Rate=1662/1.12)

10

14839

1483.93

... More
Providing, fixing, testing & commissioning of standard firemans axe with heavy rubber handle. (As per MR-7) (Rate=550/1.18)

10

4661

466.1

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. (As per DSR_E&M _2022_16.8) (Rate=1196/1.12)

10

10678

1067.86

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (As per DSR_E&M _2022_18.20) (Rate=18244/1.12)

2

32578

16289.29

... More
Providing, fixing, testing & commissioning of automatic Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1).. (As per MR-3) (Rate=1990/1.18)

2

3372

1686.44

... More
Providing, fixing, testing & commissioning of indoor type hose lockable cabinet frames fabricated from 40 x 40 x 5 angle iron sections and 16 gauge MS sheet with full front glass door and locking arrangement, suitable to accommodate landing valves, 15 m long hoses, first-aid hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade, as required (Approx 2.1 m (high) x 0.9 m (wide). The item shall be complete of MS housing with front door. (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hamer). (As per MR-2) (Rate=6543.33/1.18)

10

55451

5545.19

... More
Portable Chemical Fire Extinguishers Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). Providing & fixing ISI marked portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres conforming to IS: 15683:2006 with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets. (As per MR-9) (Rate=4508/1.18)

10

38203

3820.34

... More
Providing & fixing ISI marked (IS:15683:2006) portable CO2 type fire extinguisher type 4.5 kg capacity. Including valve, discharge hose of not less than 10 mm dia & 1 M long complete in all respects including initial filled with CO2 gas confirming to IS:307-1966 & filled to a filling rate of not more than 0.667 and wall suspension bracket. (As per MR-10) (Rate=6681.50/1.18)

10

56622

5662.29

... More
Providing & fixing of ABC Type, Portable Fire Extinguisher, dry powder type (Gas Cartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with dry powder, ISI marked confirming to IS:15683 : 2006 complete with standard discharge valve with tube, CI bracket for wall mounting. (As per MR-11) 4 Kg (Rate=2135.55/1.18)

10

18097

1809.79

... More
Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS: 15683 : 2006 50 Litres (trolley mounted) (As per MR-12) (Rate=10752.50/1.18)

2

18224

9112.29

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet confoming to IS: 2546, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer. (As per MR-13) (Rate=1035.69/1.18)

10

8777

877.7

... More
Sprinkler, Piping & Accessories Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and the supply of the same shall also be included in rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted. MS `C' Heavy class pipe 25 mm dia(As per DSR_E&M _2022_18.7.1) (Rate=744/1.12)

1550

1029642

664.29

... More
32 mm dia(As per DSR_E&M _2022_18.7.2) (Rate=851/1.12)

369

280374

759.82

... More
40 mm dia(As per DSR_E&M _2022_18.7.3) (Rate=1034/1.12)

524

483764

923.21

... More
50 mm dia(As per DSR_E&M _2022_18.7.4) (Rate=1281/1.12)

627

717131

1143.75

... More
65 mm dia(As per DSR_E&M _2022_18.7.5) (Rate=1614/1.12)

294

423675

1441.07

... More
80 mm dia(As per DSR_E&M _2022_18.7.6) (Rate=1885/1.12)

439

738852

1683.04

... More
100 mm dia(As per DSR_E&M _2022_18.7.7) (Rate=2555/1.12)

419

955843

2281.25

... More
150 mm dia(As per DSR_E&M _2022_18.7.8) (Rate=3574/1.12)

153

488233

3191.07

... More
Providing, fixing, testing & commissioning of butterfly valve (PN 16) (suitable for test pressure of 24 kg / sqcm) with flanges, nut bolts, gaskets, painting and necessary pad locking arrangement complete required. 100 mm dia(As per DSR_E&M _2022_18.11.5) (Rate=6667/1.12)

4

23810

5952.68

... More
150 mm dia```(As per DSR_E&M _2022_18.11.6) (Rate=8960/1.12)

14

112000

8000

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 150 mm dia(As per DSR_E&M _2022_18.14.7) (Rate=17786/1.12)

6

95282

15880.36

... More
Providing, fixing, testing & commissioning of brass quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type & temperature rating shall be as follows : Pendent /UPRIGHT (68 °C) sprinkler (As per DSR_E&M _2022_18.21.1) (Rate=522/1.12)

1255

584919

466.07

... More
Providing, fixing, testing & commissioning of inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete strictly as per drawing. (As per MR-14) (Rate=17475/1.18)

8

118474

14809.32

... More
Providing, fixing, testing & commissioning of dial type (100 mm) pressure Switch with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required. (As per DSR_E&M _2022_18.22) (Rate=1546/1.12)

10

13803

1380.36

... More
Providing & fixing in position the industrial type pressure gauges with gun metal/ brass valves complete as required. (As per DSR_E&M _2022_16.8) (Rate=1196/1.12)

12

12814

1067.86

... More
150 mm dia(As per DSR_E&M _2022_18.23.2) (Rate=9021/1.12)

10

80544

8054.46

... More
Providing & Fixing of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications complete as required. 150 mm dia(As per DSR_E&M _2022_18.24.3) (Rate=48202/1.12)

2

86075

43037.5

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. (As per DSR_E&M _2022_18.20) (Rate=18244/1.12)

2

32578

16289.29

... More
PART-3 HVAC Variable refrigerant Volume/Flow System Outdoor Unit Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled outdoor units suitable for cooling and heating, having all hermitecally sealed inverter type scroll compressor(s), minimum two compressor for above 14 HP modules, microprosessor based controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required, The unit shall deliver the rated capacity at AHRI conditions and work even at 500C ambient temperature without tripping. The unit shall be suitable to wok on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 40 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X40)

2

1313200

656600

... More
38 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X38)

4

2495080

623770

... More
36 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X36)

1

590940

590940

... More
34 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X34)

1

558110

558110

... More
32 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X32)

1

525280

525280

... More
Indoor Unit Cassette Type Supply, Installation, Testing & Commissioning of following minimum capacity 4-way flow VRF/VRF Cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolator, cordess remote control etc., suitable for operation on single phase 230V + 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system or fire panel of the building. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 3.2 TR 4 Way VRV/VRF Cassette Unit(As per DSR_VRF/VRV _2019_2.8)

9

295083

32787

... More
2.0 TR 4 Way VRV/VRF Cassette Unit(As per DSR_VRF/VRV _2019_2.5)

5

154005

30801

... More
Indoor Unit High Wall Type Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pump, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0.6 TR(As per DSR_VRF/VRV _2019_3.1)

38

711740

18730

... More
0.8 TR(As per DSR_VRF/VRV _2019_3.2)

4

77248

19312

... More
1TR(As per DSR_VRF/VRV _2019_3.3)

15

295500

19700

... More
1.3TR(As per DSR_VRF/VRV _2019_3.4)

6

127056

21176

... More
1.65TR(As per DSR_VRF/VRV _2019_3.6)

7

152222

21746

... More
2.0 TR(As per DSR_VRF/VRV _2019_3.7)

12

265200

22100

... More
Indoor Unit Ductable Type Supply, Installation, Testing & Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V + 10%, 50Hz, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system or fire panel of the building. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Mid Static Ductable Units (Minimum 45 Pascal External Static Pressure) 4.0 TR(As per DSR_VRF/VRV _2019_4.16)

1

48731

48731

... More
High Static Ductable Units (Minimum 110 Pascal External Static Pressure) 5.5 TR(As per DSR_VRF/VRV _2019_4.17)

4

343064

85766

... More
7.1 TR(As per DSR_VRF/VRV _2019_4.18)

3

261843

87281

... More
8.0 TR(As per DSR_VRF/VRV _2019_4.19)

18

1612620

89590

... More
Supply Installation, testing & commissioning of Y-joints for various size of Refrigerant pipe including insulation. (As per MR-1) (Rate=4123/1.18)

114

398323

3494.07

... More
Centralized controller Supply Installation, testing & commissioning of Main Intelligent touch screen central controller system including all the accessories suitable to operate, monitor, on/off, temperature setting of all the indoor units individually complete as required and as specified. (As per MR-2) (Rate=80703/1.18)

2

136784

68392.37

... More
Copper Refrigerant Piping Supply, Installation, Testing & Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with with Class-O closed cell elastometric nitrile rubber insulation of specified thickness as given below for Suction and Liquid lines, exposed piping shall be protected with UV & water protective coating, all accessories as per specifications etc. as required: 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation (As per DSR_VRF/VRV _2019_5.1)

140

34300

245

... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.2)

530

175430

331

... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.3)

250

116500

466

... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.4)

280

164640

588

... More
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.5)

415

293405

707

... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.6)

160

138400

865

... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.8)

125

138500

1108

... More
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.10)

50

61500

1230

... More
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.12)

285

373065

1309

... More
Drain Piping Supplying & fixing of UPVC drain piping with all fitting such as bends, tees etc. necessary clamps, adequate support duly insulate with 9 mm nitrile rubber insulation complete as per technical specifications, requirement, standardard and drawings complete as required. 50 mm dia(As per MR-3) (Rate=298/1.18)

85

21466

252.54

... More
40 mm dia(As per MR-3) (Rate=204/1.18)

60

10372

172.88

... More
32 mm dia(As per MR-3) (Rate=157/1.18)

40

5322

133.05

... More
25 mm dia (As per MR-3) (Rate=121/1.18)

150

15381

102.54

... More
Inline Fans Supply, Installation, testing and commissioning circular direct driven / cabinet inline fans of G.I. construction complete with centrifugal fan with motor, accoustically lined, canvass connection at inlet and outlet complete with electric panel with MCB and relays, with 5 Rm cabling and earthing complete as per standards, requirement and drawings. 3300 cfm 20 mmwg S.P(As per MR-4) (Rate=45163/1.18)

2

76547

38273.73

... More
800 cfm 15 mmwg S.P(As per MR-4) (Rate=23520/1.18)

1

19932

19932.2

... More
550 cfm 15 mmwg S.P(As per MR-4) (Rate=17064/1.18)

2

28922

14461.02

... More
500 cfm 15 mmwg S.P(As per MR-4) (Rate=17064/1.18)

10

144610

14461.02

... More
450 cfm 15 mmwg S.P(As per MR-4) (Rate=15743/1.18)

1

13341

13341.53

... More
400 cfm 15 mmwg S.P(As per MR-4) (Rate=15743/1.18)

3

40024

13341.53

... More
350 cfm 15 mmwg S.P(As per MR-4) (Rate=15743/1.18)

2

26683

13341.53

... More
300 cfm 15 mmwg S.P(As per MR-4) (Rate=14056/1.18)

3

35735

11911.86

... More
250 cfm 15 mmwg S.P(As per MR-4) (Rate=13102/1.18)

4

44413

11103.39

... More
200 cfm 15 mmwg S.P(As per MR-4) (Rate=13102/1.18)

1

11103

11103.39

... More
150 cfm 15 mmwg S.P(As per MR-4) (Rate=12662/1.18)

3

32191

10730.51

... More
100 cfm 15 mmwg S.P(As per MR-4) (Rate=12662/1.18)

6

64383

10730.51

... More
Propeller Type Fan Supply, installation, testing and commissoning of propeller type fan for exhaust air complete with in and out gravity louvers, 3 pin socket with 5RM cabling complete as per specifications, requirement, standard and drawings. 200 mm dia, 5 mmwg S.P. (As per MR-5) (Rate=13039/1.18)

9

99450

11050

... More
Exposed Copper Pipe Coating Supplying and fixing of UV/fire/water, thermal protective coating, with canvas/glass fibre cloth, coating on copper pipe insulation by wrapping canvas/glass fibre cloth dipped in star bond/poly bond 30-36 complete as per specifications and drawings.(The price should be quoted considering minimum 3 coats of 30-36 chemical). (As per MR-6) (Rate=587/1.18)

100

49745

497.46

... More
Packaged Type Airwasher Supply, installation, testing and commissioning of floor mounted CELLULOSE FILL AIR-WASHER complete with double skin construction fabricated out of extruded aluminium sections with 0.8 mm thick pre-plasticised GI sheet on out side and 0.8 mm thick plane GI sheet inside with 25 mm thick insulation, 40 Kg / m3 density PUF insulation in between. The unit shall comprise of supply fan sections with DIDW backward curve fans (efficiency not less than 75%) suitable for static pressure as required, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply, giving 95% adiabatic saturation efficiency at 500 FPM air velocity across pads, factory assembled and complete with 16 gauge GI casing for Air washer section, 18G SS-304 water tank, Cellulose fill, water distribution header, PVC piping, butterfly valves, for quick fill, isolation of tank, pumps and brass strainers, Y strainers, fire rated flexible duct connections & aluminium volume control damper at blower discharge and necessary fittings, belt drive package, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The fan and motor shall be mounted on aluminium extruded section.The unit shall also include provision of GSS partitions duly reinforced at intake side of air washer and GSS louvers with bird-screen synthetic washable filters and four bend PVC drift eliminators and horizontal monoblock pumps of suitable rating, factory mounted on mild steel channel base with electric motor for circulation of water. Pumps shall be aligned and suitable for 415±10% volts, 50 cycles 3 phase power supply. One No. 3 phase isolator switch in weather proof enclosure shall be provided near motor complete as required confirming to specification. 3,000 CFM, 50 mmwg Static Pressure (As per MR-7) (Rate=205427/1.18)

1

174090

174090.68

... More
Exhaust Scrubber Supply, installation, testing & commissioning of double skin exhaust scrubber of 0.6 mm inner and outer skin construction fabricated from precoated sheet blower housing with DIDW backward curved centrifugal blower with fan motor and belt drive arrangement with totally enclosed fan cooled class F insulation, with IP 55 protection, TEFC high efficiency motor type IE-3 suitable for 415+-10% volts, 50 HZ, 3 Phase A.C. supply, all accessories like common base frame, fan, motor pulley, belts, fire proof canvass connection, vibration isolator, prefilters, wet scrubber section, spray, nozzels, filters, M.S. frame for supports etc.complete as per specifications, requirement, standardard and drawings. 4,000 CFM, 65 mmwg Static Pressure (As per MR-8) (Rate=220100/1.18)

1

186525

186525.42

... More
Ducting Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. G.I. Sheet Metal Ducting (Rectangular) Thickness 0.63 mm sheet (As per DSR_E&M _2022_16.12.1.1) (Rate=1080/1.12)

2080

2005714

964.29

... More
Thickness 0.80 mm sheet (As per DSR_E&M _2022_16.12.1.2) (Rate=1263/1.12)

35

39468

1127.68

... More
Thickness 1.0 mm sheet (As per DSR_E&M _2022_16.12.1.3) (Rate=1381/1.12)

20

24660

1233.04

... More
Thickness 1.25 mm sheet (As per DSR_E&M _2022_16.12.1.4) (Rate=1836/1.12)

20

32785

1639.29

... More
Grilles / Diffuser Supply, installation, testing and commissioning of Aluminium extruted powder coated supply and return air grilles/ diffusers as per specifications and drawings (Approval of colour shall be taken from Architects/Consultants). Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.(As per DSR_E&M _2022_16.15) (Rate=9105/1.12)

37.6

305667

8129.46

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.(As per DSR_E&M _2022_16.16) (Rate=5910/1.12)

174.8

922382

5276.79

... More
Supply, fixing, testing & commissioning of Return air diffussers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.(As per DSR_E&M _2022_16.18) (Rate=8121/1.12)

4.4

31903

7250.89

... More
Louvers Supply and fixing of Fresh / Exhaust air Aluminium extruded with bird screen, damper adjustable louvers as per specifications and drawings.(As per MR-9) (Rate=12986/1.18)

2.9

31914

11005.08

... More
Volume Control Damper Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (As per DSR_E&M _2022_16.13) (Rate=7046/1.12)

2.5

15727

6291.07

... More
Flexible Duct Supply of 25 mm glass wool insulated double lamination of metalize polister film parmantely bounded to a coated spring wire, helix and resistant construction of tear and pincture branch and collor where ever suitable of following sizes. Connected at both ends with necessary jublie clamps 150 MM Dia(As per MR-10) (Rate=404/1.18)

35

11983

342.37

... More
Isolator Supplying & installation of weather proof isolator with suitable rating near each outdoor unit and complete as required. 63 Amps(As per MR-11) (Rate=5136/1.18)

8

34820

4352.54

... More
40 Amps(As per MR-11) (Rate=5136/1.18)

10

43525

4352.54

... More
Control & Transmission Wiring Supplying & fixing control cum transmission wiring of copper in heavy duty conduits PVC conduits between indoor and out door unit. (As per MR-12) (Rate=113/1.18)

2235

214029

95.76

... More
Sub Panel For Kitchen Supply, installation,testing & commissioning of sub panel board cubical compartmentalised, weather proof Floor/ Wall mounted made of 2.0 mm thick steel sheet duly painted complete with voltmeter, ammeter, indicating lights for selector switch, incoming/outgoing feeders,NO/NC contactors, CTS contactors complete as per specifications and requirement 1 No. 32 Amps TPN incoming MCB 1 set 40 Amps TPN Aluminium conductor bus bar duly sleeved. 2 Nos. 25 Amps MCB outgoing along with 2 Nos. DOL starter for Scrubber Motor (5.5 kw) (1 No Spare). 2 Nos. 16 Amps MCB outgoing along with 2 Nos. DOL starter for Airwasher Motor (3.7 kw) (1 No Spare). 3 Nos. 6 Amps SPN MCB outgoing for Airwsher & Scrubber Pump.(0.37 / 0.55 kw) (1 No. Spare).(As per MR-13) (Rate=124723/1.18)

1

105697

105697.46

... More
Power Cabling Supply & fixing of PVC sheathed Aluminium / Copper cables for various equipments through walls/ceiling with appropriate clamps & fixing arrangement as per specifications and drawings. 3C - 4 sqmm (Aluminium) for Airwasher & Scrubber(As per MR-14) (Rate=126/1.18)

30

3203

106.78

... More
3C - 2.5 sqmm (Aluminium) for Airwasher & Scrubber pump(As per MR-14) (Rate=117/1.18)

30

2974

99.15

... More
4C - 16 sqmm (Copper) (As per MR-14) (Rate=1102/1.18)

150

140084

933.9

... More
4C - 10 sqmm (Copper) (As per MR-14) (Rate=753/1.18)

60

38288

638.14

... More
Cable Tray Supplying and installation of following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.2) (Rate=604/1.12)

150

80892

539.29

... More
300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.4) (Rate=777/1.12)

75

52031

693.75

... More
450 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.6) (Rate=1137/1.12)

50

50758

1015.18

... More
Earthing Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (As per DSR_E&M _2022_5.15) (Rate=244/1.12)

200

43571

217.86

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.(As per DSR_E&M _2022_5.16) (Rate=70/1.12)

200

12500

62.5

... More
Ductable Split Unit Supplying,installation,testing & commissioning of ductable type split unit air-conditioners with evaporator with coil, fan and fan motor, aircooled condenser with hermatically sealed scroll compressor, condenser coil, propeller fans controls, mounting stand for ODU, control panel, corded remote, canvass connection as per standards, requirement and drawings. 3.0 Tons(1 Working & 1 Standby) for Server Room(As per MR-15) (Rate=88040/1.18)

2

149220

74610.17

... More
Refrigerant Piping (For Split) Supplying & installation copper soft/hard refrigerant piping along (Circuit length) with control cabling and earthing should be insulated with 9 mm thick pipe section of nitrile rubber complete in all respect. 3.0 Tons Ductable Split Unit(As per MR-16) (Rate=1981/1.18)

40

67152

1678.81

... More
Sequence Controller Providing and fixing microprocessor based control panel cum seqence operation controller for ductable unit in server room including wiring etc. The controller shall perform mainly the following function To run only required set of unit. To set timer for operation of each unit. To start standby unit incase of breakdown fault or on temerature rise of space. (As per MR-17) (Rate=15407/1.18)

1

13056

13056.78

... More
PART-4 GLASS WORK GLASS Under DOME Area :- 23.04 MM THICK THREE LAYER TOUGHENED GLASS (10mm TOUGHENED GLASS + 3.04 PUB + 10mm TOUGHENED GLASS) INCLUDING SUPPLYING AND FIXING+Silicon + Tape + Rubber Gasket+ Scaffolding as/Specification given by incharge.(As per MR-1) (Rate=23700/1.18)

225.4

4527101

20084.75

... More
TRUSS WORK : Providing and fixing stainless steel ( Grade 304) made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).(As per DSR _Civil_2021_10.28) (Rate=612.25/1.12)

5880

3214312

546.65

... More
Erection Work : Hire and running charges of crane having capacity 50MT hire - charges include cost of services of operating staff, Cost of lubricating oil, diesel / Petrol/ Kerosene oil , other consumables for running the plant and machinery and excluding GST. The hire charges of plant machinery on per day basis are for single shift of eight working hours. DSR_CIVIL_2021_ CODE NO. 0072

30

255000

8500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.