Banaras Hindu University Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Banaras Hindu University - BHU Tender
Machinery and Tools
GEM
Opening Date10 Jun 2024
Closing Date12 Jul 2024
Tender Amount₹ 1,90,09,746 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 4,90,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5033143Bid Award Id
ViewTender No
GEM/2024/B/5033143Tender Authority
Banaras Hindu University ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
spinal_tender_1_2024-06-10-16-03-41_9cce5296afa95b37d596cae9d562d193.pdf
boq_item_sample_spinal_tender_1_2024-06-10-16-03-41_4f117ee872566e3eae294797309ae935.csv
BOQ Items
Title 4 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 5 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 4.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 6 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 7 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 8 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
100
-
-
Title 9 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
100
-
-
Title 10 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 11 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 12 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 13 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
250
-
-
Title 14 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
250
-
-
Title 15 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 16 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 30 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 17 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 35 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 18 , Provide optimal small pupil capabilities ,with a pupil as small as 2 - 3 mm. It provides excellent fundoscopy through a miotic pupil , so you wont miss a single detail.103 / 124 Degree field of view ,0.45 x image magnification ,2.20 x laser spot magnification , 4 mm working distance Excellent wide field views past the vortex Most popular choice for fast undilated screening exams. Supplier Must Have ISO ,IEC Certificate and MD - 42 , Also Authorization from OEM
2
-
-
Title 19 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 40 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces ,The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw ,Screw should be 5.5mm Compatible Rod. ,cross link connectors & rod to rod connectors, screw must have a built in Square threaded inni locking mechanism- OEM Should be ISO13485 ,CDSCO & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 20 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 45 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces , The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw , Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 21 , A Differential Thread Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 50 mm length Patented Quad Lead thread form extends average 18mm from the head of the screw and doubles the Number of contact points with the cortical wall of the Pedicle. Increases the resistances to axial pull out forces ,The Product should be conical in shape and must have self - tapping & self - centering tip for bone Screw ,Screw should be 5.5 mm Compatible Rod. , cross link connectors & rod to rod connectors , screw must have a built in Square threaded inni locking mechanism - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 22 , Titanium INNI Screws must have Square Shape built in threaded Inni for locking Mechanism, Inni SIZE 9.9 x4.8 mm compatible of Above mention Pedicle Screw OEM Should be ISO CDSCO and USFDA Certified Supplier Should be OEM Authorized Certified and ISO Certified from notified body
1000
-
-
Title 23 , Pre cut rod 5.5 mm rod with blunt end 50 mm in length should have alignment Marking Made up of medical grade Titanium OEM Should be ISO CDSCO & USFDA Certified and Should be Manufactured in India Supplier Should be OEM Authorized Certified & ISO Certified from notified body
10
-
-
Title 24 , Pre cut rod 5.5 mm rod with blunt end 60 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
10
-
-
Title 25 , Pre cut rod 5.5 mm rod with blunt end 70 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 26 , Pre cut rod 5.5 mm rod with blunt end 80 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 27 , Pre cut rod 5.5 mm rod with blunt end 90 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 28 , Pre cut rod 5.5 mm rod with blunt end 100 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 29 , Pre cut rod 5.5 mm rod with blunt end 150 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
30
-
-
Title 30 , Pre cut rod 5.5 mm rod with blunt end 200 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
30
-
-
Title 31 , Pre cut rod 5.5 mm rod with blunt end 250 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 32 , Pre cut rod 5.5 mm rod with blunt end 500 mm in length should have alignment Marking. Made up of medical grade Titanium. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 33 , A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size small - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
30
-
-
Title 34 , A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size Medium - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
80
-
-
Title 35 , A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size Large - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
70
-
-
Title 36 , A Connector to Increase the rigidity of rod screw construct & provides additional stability. The Interconnection assembly can adjusted to minimize and reduce interference with the spinal column size Extra Large - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 37 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 10 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 38 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 12 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 39 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 14 mm , . Should have compatible with our existing systems - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 40 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 16 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 41 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 18 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 42 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 20 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 43 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 22 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 44 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 24 mm , . Should have compatible with our existing systems - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 45 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 26 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 46 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 26 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 47 , A Poly Axial Screw must have Cortical fix thread in 3.5 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 30 mm , . Should have compatible with our existing systems - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 48 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 10 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 49 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 12 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 50 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 14 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 51 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 16 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 52 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 18 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 53 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 20 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 54 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 22 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 55 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 24 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 56 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 26 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 57 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 28 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 58 , A Poly Axial Screw must have Cortical fix thread in 4.0 mm diameter with a quick start tip Fully Threaded , having up to 92 degree cone of angulation , screw head must accept 3.5 & 4.0 mm rod system , must be compatible with cross link connectors & rod to rod connectors , screw must have an built in threaded inni locking mechanism Size 30 mm , . Should have compatible with our existing systems. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 59 , Tapered rod must accommodate 3.5 /4.0 mm lateral mass screw and 5.5 mm differential thread screw - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 60 , Pre cut rod 3.5 mm rod with blunt end 30 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 61 , Pre cut rod 3.5 mm rod with blunt end 35 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 62 , Pre cut rod 3.5 mm rod with blunt end 40 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 63 , Pre cut rod 3.5 mm rod with blunt end 45 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 64 , Pre cut rod 3.5 mm rod with blunt end 50 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 65 , Pre cut rod 3.5 mm rod with blunt end 60 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 66 , Pre cut rod 3.5 mm rod with blunt end 70 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 67 , Pre cut rod 3.5 mm rod with blunt end 80 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 68 , Pre cut rod 3.5 mm rod with blunt end 90 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 69 , Pre cut rod 3.5 mm rod with blunt end 100 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 70 , Pre cut rod 3.5 mm rod with blunt end 120 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 71 , Pre cut rod 3.5 mm rod with blunt end 140 mm in length should fit above mentioned lateral mass screw and Occipital Plate , made up of medical grade Titanium. - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 72 , Skin marker pen for thick Marking (gamma sterile) , Level 1 Protection as per ANSI/ AAMI standard/ ISO 13485 - 2016 - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
1000
-
-
Title 73 , This drape is used for all kind of spinal surgeries & Laminectomies etc. level 4 protection as per ANSI/AAMI standards. Material 50 gsm , SMS polypropylene water repellent sheet Size 1.5 x 3 mm , incise sheet 15x 35 cm , poly sheet lining 1.20 x 1.20 m. Level 1 Protection as per ANSI/ AAMI standard/ ISO 13485 - 2016 - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
300
-
-
Title 74 , PEEK TLIF Cage is single component device used to restore height of disc space by Transformational approach and to facilitate lumbar interbody fusion with maintaining physiological lordotic angulation of lumbar spine. The vertical square teeth with Trapezoidal Shape and Height 0.5 mm made of material (Polyetheretherketone , ASTM F2026 - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
25
-
-
Title 75 , USFDS approved Cervical Interbody Fusion devise made of Titanium material should be available with convex anatomy design ,teardrop foot print ,Lateral window for postoperative fusion evaluation ,large axial graft window , leading edge for ease of insertion ,superior and inferior teeth to resist migration and should be available in 1mm height increments starting from 5mm to 12 mm and footprint of 13x14 mm only ,As per Required Size to be Supplied as per PO - OEM Should be CE & USFDA Certified ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body
25
-
-
Title 76 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 30 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge- Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors- OEM Should be ISO13485 ,CDSCO & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 77 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 35 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 78 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 40 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 79 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 45 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , S Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 80 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 5.5 mm diameter & 50 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 81 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 30 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 82 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 35 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 83 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 40 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 84 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 45 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 85 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 6.5 mm diameter & 50 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 86 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 30 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 87 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 35 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 88 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 40 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 89 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 45 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 90 , Minimally Invasive Spine Polyaxially Screws must have Cortical fix thread in 7.5 mm diameter & 50 mm length Patented Quad Lead thread Screw , Screw Head with rimmed edge - Screw should be 5.5mm Compatible Rod. , cross link connectors & rod to rod connectors - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 91 , Titanium Grade Peek Spinal Domino Connector Size 10 mm - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 92 , Titanium Grade Peek Spinal Domino Connector Size 12 mm - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 93 , Titanium Grade Peek Spinal Domino Connector Size 14 mm - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 94 , Mesh Cage in a wide variety of diameters , lengths , and styles , Can also be trimmed to specific heights , Triangle Shape in design. Supplier to be supply Mesh Cage on required Size as per PO (8 to 18 ) (L - 20 to 100) - OEM Should be ISO13485 , CDSCO & INDIAN FDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 95 , Balloon kyphoplasty is a minimally invasive procedure for treating painful vertebral body fractures on the thoracic or lumbar spine. This surgical therapy stabilizes the spine and relieves pain. Pressure Gauge indicates the pressure of the balloon . Single Balloon Catheter kit Length 16.3 to 19 mm , Maximum Diameter - 16.3 , PSI Rating - 150 - Manufacturers must have CE Certified and Imported Product , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
50
-
-
Title 96 , Balloon kyphoplasty is a minimally invasive procedure for treating painful vertebral body fractures on the thoracic or lumbar spine. This surgical therapy stabilizes the spine and relieves pain. Pressure Gauge indicates the pressure of the balloon . Double Balloon Catheter Kit Length 16.3 to 19 mm , Maximum Diameter - 16.3 , PSI Rating - 150 - Manufacturers must have CE Certified and Imported Product , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
70
-
-
Title 97 , Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 5 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 98 , Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 6 / 13 MM , - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 99 , Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine ,system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 7 / 13 MM - OEM Should be ISO ,CE , ZED GOLD & USFDA Certified and Should be Manufactured in India ,Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 100 , Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 8 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 101 , Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 9 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 102 , Stand alone cages for cervical spine - Integrated plate and spacer is designed to preserve the natural anatomical profile of the spine , system streamlines the entire ACDF procedure and facilitates a less invasive approach through a small incision with less retraction for biomechanical strength of a traditional ACDF with two self drilling screw 10 / 13 MM - OEM Should be ISO , CE , ZED GOLD & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 103 , Pedicle reduction screw for listhesis correction Die 5.5 rod system length 35 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
10
-
-
Title 104 , Pedicle reduction screw for listhesis correction Die 5.5 rod system length 40 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
25
-
-
Title 105 , Pedicle reduction screw for listhesis correction Die 5.5 rod system length 45 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - must be USFDA Approved , manufacturer must have ZED certificate & CE certificate from notified body - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
25
-
-
Title 106 , Pedicle reduction screw for listhesis correction Die 6.5 rod system length 35 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
10
-
-
Title 107 , Pedicle reduction screw for listhesis correction Die 6.5 rod system length 40 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
25
-
-
Title 108 , Pedicle reduction screw for listhesis correction Die 6.5 rod system length 45 mm breakable wings and the head is multiracial Head design should be tapered tulip type to minimize facet impingement its should accommodate 5.5 mm rod system . Should be bio compatible & mri friendly. Screw must have dual thread starting cancellous & self tapping threads. Inni screw design in such a way to prevent rod migration. Should have compatible with our existing systems. - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
25
-
-
Title 109 , This type of needle biopsy uses a thin , hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses a wider needle than does fine - needle aspiration. The needle used during a core needle biopsy is a hollow tube that allows the doctor to extract a sample of tissue for testing - OEM Should be ISO13485 , CDSCO & USFDA Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
16
-
-
Title 110 , Imported Instrument Full set Compatible with above mentioned pedicle Screws and with Storage Box on loaner Basis
1
-
-
Title 111 , Imported Instrument full set Compatible with above mentioned Lateral mass Screws and with Storage Box on loaner Basis
1
-
-
Title 112 , Saw System - The Saw Hand Piece is light weight and has a tool less attachment for blades. Saw Hand Piece is Autoclavable. Speed of the Saw Hand Piece is 20 , 000 rpm. Torque of the Saw Hand Piece is 2.5 Nm Charger - two single station chargers , which makes it easy to carry from one OT to another , if required. Battery is Ni - MH Battery , 14.4 Volts. Minimum Run time after each charge is 40 Minutes. Charging time is minimum 1.5 Hrs. . There are 2 batteries provided with each hand piece.OEM Should be ISO , CDSCO Certified , Supplier Should be Provide 5 yr. CMC , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
3
-
-
Title 113 , Quick bone healing and Quick setting calcium hydroxyapatite injectable cement sets in 10 - 20 minutes. This cement acts as osteoinductive material and promotes bone healing it helps in conduction of new bone formation. This cement include with dish , syringe , spatula and 14 gauge needle provided with in the packet Size 5 Gram - OEM Should be ISO , GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
20
-
-
Title 114 , It has outer surface , it prevents slipping of cage and induces better osteon - integration. Thereby creating better fusion of vertebral bodies. It also prevent subsequent migration of spinal cage. Surface have honeycomb structure. Each cage is pre - filled with hydroxyapatite , by creeping substitution the bone will grow into the spinal cage. Further improving integration with vertebral body bone. Making it a natural part of the spine , Highly polished entry point for easier placement Size 6 angle x 12 mm - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
2
-
-
Title 115 , It has Peek Serrated outer surface , it prevents slipping of cage and induces better osteon - integration. Thereby creating better fusion of vertebral bodies. It also prevent subsequent migration of spinal cage. Surface have honeycomb structure. Each cage is pre - filled with hydroxyapatite , by creeping substitution the bone will grow into the spinal cage. Further improving integration with vertebral body bone. Making it a natural part of the spine , Highly polished entry point for easier placement Size 6 angle x 8 mm - OEM Should be ISO & GMP Certified and Should be Manufactured in India , Supplier Should be OEM Authorized Certified & ISO Certified from notified body
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements