Banaras Hindu University Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Banaras Hindu University - BHU Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jan 2024
Closing Date16 Jan 2024
Tender Amount₹ 42,35,895
Costs
EMD
₹ 84,718Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BHU_789159_1Bid Award Id
ViewTender No
UWD/2024/06012024-1Tender Authority
Banaras Hindu University ViewPurchaser Address
-Website
http://http://www.bhu.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special Repair of HVAC System installed for Trauma Centre, IMS, Banaras Hindu University, Varanasi (U.P.)
BOQ Items
SITC Of Lube oil
510
-
-
SITC Of Oil Filter
9
-
-
SITC Of Shut off Valve
9
-
-
SITC Of Drier Core
27
-
-
Supply and fixing of Canvas connection of OT - 2 AHU of 3000 CFM (400x400MM) Fire proof material
1
-
-
Overhauling of Secondary Chilled Water Pump (25HP) including dismantling, replacement of defective bearings, remetaling of shaft, polishing, reassembling and commissioning of the same.
1
-
-
Overhauling of Hot Water Pump (7.5HP) including dismantling, replacement of defective bearings, Mechanical seal remetaling of shaft, polishing, reassembling and commissioning of the same.
3
-
-
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below.
FRP SEALING Compound
90
-
-
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below.
Splash Cap with steel screw
900
-
-
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below.
PVD END CAP 63 mm dia.
40
-
-
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below.
PVC pipe 63MM X10 feet long
274
-
-
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,.
Evaporative cooling Pad
81
-
-
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,.
Roof and base 35 MM thick insulated with supporting frame
162
-
-
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,.
One mono block pump (0.5HP ) make ;Crompton
1
-
-
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,.
Pre Filter of size( 675X665X50)MM
12
-
-
Supply and fixing of Canvas connection of Air Washer(1200X1200 MM) Wire proof.
1
-
-
Descaling and cleaning of cooling coil/Heating Coil of AHUs/CSUs with the help of descaling compound, soft cleaning agent, pressure pump etc. as required.
50
-
-
Descaling and cleaning of cooling coil/Heating Coil of FCUs with the help of descaling compound, soft cleaning agent ,pressure pump etc. as required.
49
-
-
Dismantling, repairing and fixing of Heating Coil of AHU installed in OT - 7 including lifting shifting of the same to the storage.
1
-
-
Dismantling, repairing and fixing of Cooling Coil of CSU installed in Blood Bank including lifting shifting of the same to the storage.
1
-
-
SITC of Thermostat of FCU Unit (Make: Honeywell/ Siemens/ Equivalent)
2
-
-
SITC of( 300mmx575mm) With circular frame Stainless Steel Pot Strainer Jali
1
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
50 MM
75
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
65 MM
50
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
80 MM
75
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
100 MM
75
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
125 MM
50
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
150 MM
75
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
200 MM
70
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
250 MM
80
-
-
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size.
300 MM
90
-
-
Humidity and temperature device with display make -Siemens ,Honeywell
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements