Babasaheb Bhimrao Ambedkar University Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Babasaheb Bhimrao Ambedkar University - BBAU Tender
Electrical Goods and Equipments
Eprocure
Opening Date6 Feb 2019
Closing Date28 Feb 2019
Tender Amount₹ 1,17,795
Costs
EMD
₹ 3,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_BBAU_440868_1Bid Award Id
ViewTender No
BBAU/ 2019/ELECT/ 48Tender Authority
Babasaheb Bhimrao Ambedkar University ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
4 way (4+12), TPN, vertical type, MCB DB, double door (MCCB Based) (Legrand/L&T) (M/R)
1
-
-
... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (DSR 2016 - 2.2)
-
-
-
... More
100 A, 16 kA,TPMCCB (DSR 2016 - 2.2)
1
-
-
... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 63 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required. (Legrand/L&T) (M/R)
4
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR 2016 - 2.2)
-
-
-
... More
4 way (4 + 12), Double door (DSR 2016 - 2.2.1)
1
-
-
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2016 - 2.13)
-
-
-
... More
63 A (DSR 2016 - 2.13.2)
1
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2016 - 2.10)
-
-
-
... More
Single pole (DSR 2016 - 2.10.1)
14
-
-
... More
20 A SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure (DSR 2016 - 1730)
2
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR 2016 - 1.10)
-
-
-
... More
Group C (DSR 2016 - 1.10.3)
2
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (DSR 2016 - 1.27)
-
-
-
... More
3 Module (100 mmX75 mm) (DSR 2016 - 1.27.2)
12
-
-
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (DSR 2016 - 1.28)
-
-
-
... More
3 Module (DSR 2016 - 1.28.2)
12
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (DSR 2016 - 1.24)
-
-
-
... More
15/16 A switch (DSR 2016 - 1.24.3)
12
-
-
... More
6 pin 15/16 A socket outlet (DSR 2016 - 1.24.5)
12
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (DSR 2016 - 1.7)
-
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR 2016 - 1.7.3)
100
-
-
... More
Supplying and fixing brass batten/ angle holder including connections etc. as required. (DSR 2016 - 1.34)
2
-
-
... More
Supplying and fixing LED Tubelight Fitting 22 Watt including connections etc. as required. (M/R) (I.S.I./Branded)
2
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. (DSR 2016 - 7.7)
-
-
-
... More
Upto 35 sq. mm (clamped with 1mm thick saddle) (DSR 2016 - 7.7.1)
100
-
-
... More
Supply of 35 sq.mm. X 3.5 Core XLPE AL Unarmoured Cable (Havells)
100
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR 2016 - 2.4)
-
-
-
... More
4 way (4 + 12), Double door (DSR 2016 - 2.4.1)
1
-
-
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2016 - 2.15)
-
-
-
... More
63 A (DSR 2016 - 2.15.3)
1
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2016 - 2.10)
-
-
-
... More
Single pole (DSR 2016 - 2.10)
12
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (DSR 2016 - 1.27)
-
-
-
... More
3 Module (100 mmX75 mm) (DSR 2016 - 1.27.2)
12
-
-
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (DSR 2016 - 1.28)
-
-
-
... More
3 Module (DSR 2016 - 1.28.2)
12
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (DSR 2016 - 1.24)
-
-
-
... More
15/16 A switch (DSR 2016 - 1.24.3)
12
-
-
... More
6 pin 15/16 A socket outlet (DSR 2016 - 1.24.5)
12
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR 2016 - 1.10)
-
-
-
... More
Group C (DSR 2016 - 1.10.3)
1
-
-
... More
Providing & Fixing of 450 mm, 900 RPM, Single Phase Turbo Force Exhaust Fan with Louvers (M/R) (Havells)
1
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (DSR 2016 - 1.7)
-
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR 2016 - 1.7.3)
80
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements