Ayodhya Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Ayodhya Development Authority Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date9 Nov 2024
Closing Date28 Nov 2024
Tender Amount₹ 12,39,82,000
Costs
EMD
₹ 24,79,640Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Work To Develop The Currently Flowing Kutcha Drain From Fatehganj Vegetable Market To
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AFDA_972188_1Bid Award Id
ViewTender No
2024_AFDA_972188_1Tender Authority
Ayodhya Development Authority ViewPurchaser Address
-Website
http://http://www.adaayodhya.in/Default.aspx
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
20 mm Thick G.S.B.
ANALYSIS
-
3364
6923112
... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) DSR 4.1.8
-
5006
3865265.04
... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1:2 in Slab supply of reinforcement the concrete shall not beless than M-25.
DSR 5.33.1
-
6985
39037712.12
... More
Mild Steel or iron in plain work such as RCC or R.B.
DSR 5.22.6
-
7926
52163333.35
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete.
DSR 5.9.1
-
288
1780333.3
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Columns,Pillars, Piers, Abutments, Posts and Struts.
DSR 5.9.6
-
706
5587476.48
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Edges of slabs and breaks in floors and walls Under 20 cm wide.
DSR 5.9.16.1
-
153
382816.8
... More
Earth work in Excavation in trenches for foundation, pipes ,cables etc. in ordinary soil (Loam clay or sand) including lift upto 1.5 m.,lead upto 30m. And dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer
Desilting, Dredging, Deeping , Dewatering , in pond including 1.5 mt. lift and 30 mt. lead with all.
D.S.R.-2.6.1
-
130
1134219.24
... More
Shiftting of Sludge
D.S.R.-1.1.2
-
159
1112136.48
... More
PUMPING OUT WATER CAUSED BY SPRINGS, TIDAL OR RIVER SEEPAGE, BROKEN WATER MAINS OR DRAINS AND THE LIKE.(DSR 14.23)
45 Days x 50 Kl per Day
-
169
382095
... More
Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet).
DSR 2023 - 15.23.1
-
53
103368.2
... More
Dimantling brick work or stone work in lime or cement mortar and including stacking of materials as directed be the Engineer-in-charge within a distance of 60 meter (200 feet).
DSR 2023 - 15.7.4
-
1514
450427.29
... More
Disposal of Malba upto 8 Km
DSR 2023 - 15.60
-
194
76242
... More
Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
DSR 2023 - 2.6.1
-
130
252048.72
... More
Compacted Earthen water barrier in layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge.
DSR 2023 - 2.25(a)
-
514
994728.84
... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
DSR 2023 - 2.28.1
-
25
48484.67
... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 350 to 450 mm diameter
DSR 2023 - 19.21.3
-
976
43938.45
... More
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholesand dechocking of sewer lines. Dechocking and flushing of sewerline from one manhole to another by high pressure jetting system of2200 PSI for sewer line from 150mm dia upto 300mm.
DSR 2023 - 14.77
-
250
403224.5
... More
Pumping OUT WATER CAUSED BY SPRINGS, TIDAL OR RIVER SEEPAGE, BROKEN WATER MAINS OR DRAINS AND THE LIKE.(DSR 14.23)
30 Days x 100 Kl per Day
-
169
509460
... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform DSR: 14.72
-
248
24861
... More
Clearing jungle including uprooting of rank vegetation, grass
DSR 2.31
-
12
1294
... More
Excavation work by mechanical means (Hydraulic excavator)/ manualmeans in foundation trenches or drains (not exceeding 1.5m in width or10 sqm on plan).
DSR 2.9.1
-
465
42800.24
... More
20 mm Thick G.S.B.
ANALYSIS
-
3364
20520.4
... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) DSR 4.1.8
-
5006
15020.46
... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1:2 in Slab supply of reinforcement the concrete shall not beless than M-25.
DSR 5.33.1
-
6985
174649.75
... More
Mild Steel or iron in plain work such as RCC or R.B.
DSR 5.22.6
-
7926
309152.22
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete. DSR 5.9.1
-
288
7205.75
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Columns,Pillars, Piers, Abutments, Posts and Struts.
DSR 5.9.6
-
706
14131.2
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Edges of slabs and breaks in floors and walls Under 20 cm wide.
DSR 5.9.16.1
-
153
4751.68