Ayodhya Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Ayodhya Development Authority Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date21 Sep 2024
Closing Date15 Oct 2024
Tender Amount₹ 12,39,82,000
Costs
EMD
₹ 24,79,640Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AFDA_957657_1Tender No
ADA FATEHGANJ SABJI MANDI TO SAHABGANJ RCC DRAIN WORK DT 20-09-2024Tender Authority
Ayodhya Development Authority ViewPurchaser Address
-Website
http://http://www.adaayodhya.in/Default.aspx
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
20 mm Thick G.S.B.
ANALYSIS
-
6923112
3364
... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) DSR 4.1.8
-
3865265
5006.82
... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1:2 in Slab supply of reinforcement the concrete shall not beless than M-25.
DSR 5.33.1
-
39037712
6985.99
... More
Mild Steel or iron in plain work such as RCC or R.B.
DSR 5.22.6
-
52163333
7926.98
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete.
DSR 5.9.1
-
1780333
288.23
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Columns,Pillars, Piers, Abutments, Posts and Struts.
DSR 5.9.6
-
5587476
706.56
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Edges of slabs and breaks in floors and walls Under 20 cm wide.
DSR 5.9.16.1
-
382816
153.28
... More
Earth work in Excavation in trenches for foundation, pipes ,cables etc. in ordinary soil (Loam clay or sand) including lift upto 1.5 m.,lead upto 30m. And dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer
Desilting, Dredging, Deeping , Dewatering , in pond including 1.5 mt. lift and 30 mt. lead with all.
D.S.R.-2.6.1
-
1134219
130.46
... More
Shiftting of Sludge
D.S.R.-1.1.2
-
1112136
159.9
... More
PUMPING OUT WATER CAUSED BY SPRINGS, TIDAL OR RIVER SEEPAGE, BROKEN WATER MAINS OR DRAINS AND THE LIKE.(DSR 14.23)
45 Days x 50 Kl per Day
-
382095
169.82
... More
Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet).
DSR 2023 - 15.23.1
-
103368
53.95
... More
Dimantling brick work or stone work in lime or cement mortar and including stacking of materials as directed be the Engineer-in-charge within a distance of 60 meter (200 feet).
DSR 2023 - 15.7.4
-
450427
1514.25
... More
Disposal of Malba upto 8 Km
DSR 2023 - 15.60
-
76242
194
... More
Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
DSR 2023 - 2.6.1
-
252048
130.46
... More
Compacted Earthen water barrier in layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge.
DSR 2023 - 2.25(a)
-
994728
514.87
... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
DSR 2023 - 2.28.1
-
48484
25.1
... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 350 to 450 mm diameter
DSR 2023 - 19.21.3
-
43938
976.41
... More
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholesand dechocking of sewer lines. Dechocking and flushing of sewerline from one manhole to another by high pressure jetting system of2200 PSI for sewer line from 150mm dia upto 300mm.
DSR 2023 - 14.77
-
403224
250.45
... More
Pumping OUT WATER CAUSED BY SPRINGS, TIDAL OR RIVER SEEPAGE, BROKEN WATER MAINS OR DRAINS AND THE LIKE.(DSR 14.23)
30 Days x 100 Kl per Day
-
509460
169.82
... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform DSR: 14.72
-
24861
248.61
... More
Clearing jungle including uprooting of rank vegetation, grass
DSR 2.31
-
1294
12.94
... More
Excavation work by mechanical means (Hydraulic excavator)/ manualmeans in foundation trenches or drains (not exceeding 1.5m in width or10 sqm on plan).
DSR 2.9.1
-
42800
465.22
... More
20 mm Thick G.S.B.
ANALYSIS
-
20520
3364
... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) DSR 4.1.8
-
15020
5006.82
... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1:2 in Slab supply of reinforcement the concrete shall not beless than M-25.
DSR 5.33.1
-
174649
6985.99
... More
Mild Steel or iron in plain work such as RCC or R.B.
DSR 5.22.6
-
309152
7926.98
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete. DSR 5.9.1
-
7205
288.23
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Columns,Pillars, Piers, Abutments, Posts and Struts.
DSR 5.9.6
-
14131
706.56
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Edges of slabs and breaks in floors and walls Under 20 cm wide.
DSR 5.9.16.1
-
4751
153.28
Evaluation Notes How It Works ?
Potential Partner