Allahabad Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Allahabad Development Authority - ADA Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date24 May 2024
Closing Date6 Jun 2024
Tender Amount₹ 1,15,19,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S/F of 200 Amp Busbar Box made of 16 SWG CRCA Sheet including TPN Aluminium Busbar complete with locking arrangement with required Clamps nuts & bolts and grouting / .Fixed on Wall (if required on Angle stand angle will be measured in MS Items) ( PSR in PDA)

30

197100

6570

... More
S/L of Aluminiuum conductor PVC Insulated armoured served sheathed 400Sq mm x 3.5 Core LT cable 1100 volts grade at a deopth of 750mm below groundlevel over a cushion of 756 mm. Thick sand all around and protectedwith burnt bricks on sides and on top. (UPPWD-S.I.No.501(t)/2018)

15

30720

2048

... More
Same as Above but size 240 Sq mm x 3.5 Core (UPPWD-S.I.No.501(r)/2018)

1800

2482200

1379

... More
Same as Above but size 120 Sq mm x 3.5 Core (UPPWD-S.I.No.501(r)/2018)

1000

824000

824

... More
Same as Above but size 50 Sq mm x 3.5 Core (UPPWD-S.I.No.501(l)/2018)

1000

492000

492

... More
Same as Above but size 16 Sq mm x 4 Core (UPPWD-S.I.No.501(i)/2018)

1200

411600

343

... More
Same as Above but size 10 Sq mm x 2 Core (UPPWD-S.I.No.501(b)/2018)

100

29200

292

... More
S/L of 185 Sqmm 3 Core 11 KV grade cable aluminium conductor XLPE (Cross linked Polyethylene) insualted PVC bedded, Galvanied flat steel strip armored confirming to I.S. 7098 ( Part-II with latest amendement) at a depoth of 900 mm below ground level ovdr a cushion of 100 mmthick fine rriver. sand al around and protected with well burnt bricks in sides and on top purt across. ( PSR in PDA)

1400

2608200

1863

... More
S/F of 185 Sq mm 11 KV Joint Kit complete. (PSR in PDA)

12

104472

8706

... More
S/F of 400 Sq mm cable Lugs (UPPWD-S.I.No.504(0)/2018)

16

9536

596

... More
S/F of 240 Sq mm cable Lugs (UPPWD-S.I.No.504(m)/2018)

72

19584

272

... More
S/F of 120 Sq mm cable Lugs(UPPWD-S.I.No.504(j)/2018)

60

7020

117

... More
S/F of 50 Sq mm cable Lugs (UPPWD-S.I.No.504(j)/2018)

48

2304

48

... More
S/F of 16 Sq mm cable Lugs (UPPWD-S.I.No.504(d)/2018)

320

6720

21

... More
S/F of 10 Sq mm cable Lugs (UPPWD-S.I.No.504(c)/2018)

8

160

20

... More
Trenchles Drilling with HDPE 150 mm in 33 KV/100 mm in 11 KV & LT dia HDD for carring of Cable on Road Crosing complete with Repairing of all internal water connection/Sever Connection if necessary complete ( PSR in PDA)

120

118260

985.5

... More
Dismantling & Store /Street light Poles /PCC/Rail as per direction of UPPCL with Loading unloading cartage of Pole embedded in brick ballast & CC foundation etc. as required. ( PSR in PDA)

25

19597

783.9

... More
Dismantling of over head lines Wires/ ABC comprising of copper/aluminium overhead conductor, G.I, wire, cross arms, insulators etc, as Required & Deposite as per direction of UPPCL with Loading unloading cartage of all material with proper listing. ( PSR in PDA)

1000

11700

11.7

... More
Dismantiling & Removal of 11 KV S/S Transformer with Loading Unloading with Proper shifting including connections Structure Complete. Rate PSR

2

14600

7300

... More
S/F Steel tubualr Pole 9 M. Long designated 410 SP-32 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. (UPPWD-S.I.No.613/2018)

6

88026

14671

... More
S/F Steel bubular Pole 11 M. long designated 410 SP/55 in 1:3:6 cement concrete foundation including excavation back fillingetc.Rate based on S.I. No. 613/2018 on Weight basis

8

159704

19963

... More
S/F of MS Channel, Angel, Clamps and other required MS Iron Items etc. (PSR in PDA)

500

22950

45.9

... More
S/F of 100 mm x 110 mm shackle insulator (UPPWD-S.I.No.621/2018)

90

7110

79

... More
S/f of 11 KV Pin insulator complete with Pin, Nuts, & Bolts complete ( PSR in PDA)

18

1044

58

... More
S/E of overhead line with ACSR conductor on Poles/service brfackwet including binding etc. (UPPWD-S.I.No.627/2018)

200

52600

263

... More
S/E of ACSR Insulated Dog conductor on Poles/service brfackwet including binding etc. complete in all respect.

100

12900

129

... More
S/E of ACSR Insulated Weasel conductor on Poles/service brfackwet including binding etc. complete

50

2350

47

... More
S/E of overhead line with GI Wire 8 to 4 SWG on poles/service bracket including binding etc.. (UPPWD-S.I.No.628/2018)

100

6600

66

... More
S/E of Stay set at least 3.5 M. away from the Pole complete with galvanised 19 mm diax 1.80. M. long Sary clamps, stay insulator 19 mm x 600 double screw tightener, 7/4.00 mm G.I. stary wire etc. in 1:3:6; cemtn concrete complete .(UPPWD-S.I.No.630/2018)

30

96300

3210

... More
Painting of the electric pole with 2 coats of aluminium paint over red primncer complete in all respect. (UPPWD-S.I.No.634/2018)

30

9720

324

... More
Earthing of pole by MS earthing rod of 20x2500mm and 6 SWG earthing wire etc complete. ( PSR in PDA)

30

9840

328

... More
S/F of 100 mm dia GI Pipe Clas B Make Jindal Complete with required clamping . ( PSR in PDA)

48

34416

717

... More
S/F of Dead End Insulated Clamps complete on Poles as direction of E/I. ( PSR in PDA)

10

4630

463

... More
S/E of Suspension Insulated Clamps complete on Poles as direction of E/I. ( PSR in PDA)

10

3700

370

... More
Removal and Refixing of service Connections complete as per direction of E/I. ( PSR in PDA)

120

4560

38

... More
S/Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (UPPWD-S.I.No.701/2018)

15

61140

4076

... More
Deduction of Cable Rate during errection in Pipe/Duct ( Duct will be made by civil work Estimate)(UPPWD-S.I.No.507/2018)

2620

-445400

-170

... More
Supply & fixing of 9 Mtr GI Octagonal Single Arm Pole of approved make (top dia 70 mm, Bottom dia 155 mm and base plate 12 mm thik having 3mm thinkness with single arm bracket (1 mtr length) on RCC foundation including the cost of doundation, foundation bolts, excavation & Back filling and Required T&P complete(645/2018)

35

730100

20860

... More
Supply and fixing of 90 Watt LED street light Fitting having die cast aluminium body and diffuser with driver set suitable for 90 Watt. Confirming to IP 66 Protection complete in all respect. (UPPWD-S.I.No.1423/2018)

35

309750

8850

... More
S/F of followign capacity of Automatic street light cubicle control Panel painted with anti corrosive alkeli and acie proof paint considting of tme switch TSO 100 serive/Digital type with Contactors, HRC fuses, 100 Amp MCCB isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complte

1

29300

29300

... More
S/L of 6 Sq mm Twin Flate unarmoured cable complete Rate PSR in PDA

500

8550

17.1

... More
Supply & laying of following 50 mm dia (OD-50 mm nominal) DWC HDPE pipe 6 Kg ISI marked alongwith all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Ii complete with fitting and cutting. Jointing etc, direct in groudn (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. copete as required. ( PSR in PDA)

750

66825

89.1

... More
Same as above 90 mm dia (ID-90 mm nominal) 6 Kg ISI marked ( PSR in PDA)

2500

742500

297

... More
SITC of TPMO Set and DO Fuse Set 11 Kv with Handle clamps nuts bolts and required Fuse complete in all rerspect Rate UPPCL 2017-18

1

23292

23292

... More
S/C of Transformer Plinth 1.25x1.25 Meter x 2.3 Meter hight full brick work with 30 Cm foundation and 15 Cm hight CC in 1:3:6 on Top with surface plastering and white wash complete

1

7862

7862

... More
S/F of wire mesh Fencing with 2 Mtr high cage fabricated with 3 mm thick expended matal fixed on 50x50x6 mm angle frame having vertical spaced at 1 Mt and horizental spaced 1 Mtr. With 2000x1000 mm size door leaf frame 35x35x6 mm and vertical grouting at a depth of 300 mm complete. Rate SOR 2018

15

19125

1275

... More
S/P of Reflecting Red colour 230 mm x 230 mm wide strip 3 m aroudn the pole above 1.5 Mt from GL Logo of PDA Complete in all respect as per direction E/I. ( PSR in PDA)

35

8820

252



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.