Agra Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Agra Development Authority - ADA Tender

Works
Paints and Enamels
Coronavirus COVID 19
Eprocure
Opening Date22 Feb 2020
Closing Date4 Mar 2020
Tender Amount₹ 2,16,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of girders, trusses and other steel work including stacking of dismantled materials as directed by Engineer-in charge within a distance of 60 meters (200 feet) PWD 270

246.328

-

1250

... More
Dismanting doors and windws including stacking of dismantled materials as directed by Engineer-in charge within a distance of 60 meters (200 feet) PWD 703

182.955

-

29

... More
scrapping old white or colour wash including disposl of refuse as directed by Engineer-in charge within a distance of 60 meters PWD 708

145.338

-

11

... More
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window PWD 14.4.1

4.92

-

400

... More
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) CPWD 14.5.2

25.02

-

983.8

... More
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. PWD 14.12

22

-

230

... More
Raking out joints in lime or cement mortar and preparing the surface for re- pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. CPWD 14.17

58.476

-

42.93

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineering charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. CPWD 14.72

188.28

-

214.2

... More
Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer in-charge. CPWD 14.76

24

-

64.48

... More
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. CPWD 14.78

33.6

-

52.8

... More
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. CPWD 14.81

8

-

197.05

... More
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. CPWD 14.82

12

-

79.7

... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. CPWD 14.83

48.28

-

2.08

... More
Class-150 (Non Modular ) brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all materials, labor and T&P etc. required for proper CPWD 305 (a)

32.791

-

4750

... More
Construction of granular sub- base by providing coarse graded material, spreading in uniform layers with motor graded material, spreading in uniform layers with motor graded on prepared surface, mixing by mix in place method with motivator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 As in item No. 755 (a) above but consolidation of 45-63 mm 10 cm thick ( loose) coat of stone ballast CPWD 755 (a)

182.34

-

2620

... More
(a) P/L 18 mm black granite stone (super quality ) flooring over 25mm thick base of cement mortar 1:4 (1 cement :4 coarse sand )laid and jointed with white cement slurry including rubbing and polishing complete PWD New Item

71.177

-

3600

... More
R.C.C. work with cement approved coarse sand and 2cm (3/4") gauge approved stone ballast in the proportion 1:2:4 (One part of Cement. Two part of Coarse Sand and Four part of 2cm Stone Grit) in lintels of doors and window excluding supply of reinforcement and its bending and including its fixing and binding the same with 24 BWGI binding wire and including necessary centering and shuttering etc and also including supply of all materials labor and tools and plants etc. required to proper completion of the work/strength of the concrete shell not be less than M-15 grade Same as Item No. 284 above but 1:1.5:3 PWD 281 (a)

1.761

-

7100

... More
Laying of 1 shaped precast interlocking tiles of thickness 60 to 100mm ( compressive strength not less then 30Mpa and weight 4.50 kg ) including 25 mm thick local and base leveling and dressing of surface to required level and slope, filling joints with local sand all complete work. 80mm thk Rubber Moulded PWD New Item

58.473

-

1000

... More
Reinforcement of Reinforced concrete or reinforced brick work ( When not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and including the supply of steel and its wastage Bend, hooks, Binding wire and authorized over lapping shall be measured upto floor two level. PWD 504

13.388

-

6200

... More
Mild steel or iron work in heavy sizes such as trusses, built up gates record rack, roof work, gates etc. brought to required from including drilling holes revitting or welding where necessary, and also including supply of steel bolts, nuts wastage etc. and their fixing require for proper completion of the work PWD 503

5.493

-

6200

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes. Channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). PWD New Item

99.936

-

487.77

... More
SANITARY INSTALLATIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests PWD 17.1.1

6

-

3150

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid CPWD 17.2.1

14

-

3150

... More
Providing and fixing white vitreous China flat back half stall urinal of size 580 x 380x350mm with white PVC automatic flushing cistern withfittings, stndard size CP brass flush with pipe, spreaders with unionsand clamps (all in C.P. brass)with waste fitting as per IS:2556, C.I.trp with outlet grating and other couplings in CP brass, including painting of fittings and cutting nd making good the walls and floors wherever required. Range of three half stall urinals with 10 litre PVC automatic fluhing cistern. CPWD 17.5.3

9

-

11900

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD 17.7.1

11

-

1925

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. CPWD 17.22A

11

-

733.26

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia PWD 17.28.1.1

11

-

62

... More
40 mm dia PWD 17.28.1.2

2

-

70

... More
Providing and fixing 100 mm sand cast Iron grating for gully trap. CPWD 17.29

16

-

37

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. CPWD 17.31

11

-

1088.44

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia CPWD 17.35.1

120

-

837.2

... More
Sand cast iron S&S pipe as per IS: 1729 CPWD

40

-

837.2

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. CPWD 17.21

11

-

131.68

... More
WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes PWD 18.7.1

40

-

130

... More
20 mm nominal outer dia Pipes PWD 18.7.2

60

-

155

... More
25 mm nominal outer dia Pipes PWD 18.7.3

30

-

195

... More
DRAINAGE Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter PWD 19.1.1

40

-

160

... More
150 mm diameter PWD 19.1.2

124

-

230

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type:- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 PWD 19.4.1.1

6

-

1270

... More
Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : 100 mm diameter CPWD 19.5.1

82

-

52.69

... More
150 mm diameter CPWD 19.5.2

78

-

58.27

... More
Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg CPWD 19.2

16

-

554.54

... More
WATER PROOFING: Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours., Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) CPWD 22.5 (a)

78.263

-

386.6

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conformingn to IS 2645 over the RCC slab including cleaning the surface before treatment. (b) Laying cement concrete using broken bricks / brick bats 25mm to 100mm size with 50% of cement mortar 1:5 ( 1cement : 5 coarse sand) admixed with proprietary water roofing compound conforming to IS: 2645 over 20mm thick layer of cement mortar of mix 1:5 (1cement : 5 coarse sand) admixed with proprietary water proofing compound conforming to IS: 2645 to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS: 2645 (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 ( 1cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS: 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300X300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as irected and specified by the Engineer - in- charge. CPWD 22.7

448

-

845.98

... More
Making khuras 45x45cm with average minmum thickness of 5 cm cement concrete 1:2:4 (1 cement :2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400micron, finished with 12mm cement plaster 1:3 (1cement:3coarse sand) and a coat of neat cement rounding of the edges and making and finishing the outlet complete CPWD 12.22 New

18

-

202.66

... More
Providing and fixing to the inlet mouth of rain water pipes cast iron grating 15cm diametre and weighing not less than 440 grams. CPWd 12.44

18

-

39.23

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion.(i) Single socketed pipes 110mm diameter CPWD 12.41.2

180

-

253.32

... More
Providing and fixing on wall face unplasticised - PVC moduled fittings/ acessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion Bend 87.5º 110mm bend CPWD 12.42.5.2

18

-

107.81

... More
Shoe (plain) 110mm Single tee with door CPWD 12.42.6.2

18

-

94.47

... More
Single tee with door Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs screwed with MS screws of required length including cuting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110mm diameter CPWD 12.43.2

108

-

239.82

... More
FLOORING: KOTA STONE FLOORING Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick CPWD 11.26.1

808.673

-

1272

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. CPWD 11.27

271.217

-

1503.01

... More
CERAMIC GLAZED TILES Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. CPWD 11.38

135.885

-

827.64

... More
VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm PWD 11.46.1 New Item.

271.674

-

1550

... More
Ceramic wall tiles Providing and laying tiles in cladding/ dado/ jamb/ soffit/ cill of uniform thickness, size, shade and pattern as approved by Engineer's Incharge laid with rich cement slurry over a bedding plaster of 6mm (avg.) thick cement mortar 1:3 (1 cement : 3 fine sand) including the cost of 12mm average thick rough base plaster of mix 1:3 (1 cement : 3 coarse sand), providing grooves using 1mm PVC spacers and grouted with polymer based (acrylic) tile grouted (Bal grout) of matching shade of tile, cutting of tiles, scaffolding, curing etc. complete in all respects as per drawing. CPWD 8.31

336.739

-

855.54

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm CPWD 11.48.2

271.674

-

200.48

... More
NEW TECHNOLOGIES AND MATERIALS Providing corrugated Galvalume sheet roofing fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. Limpet washer filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses, 1.00mm thick with zinc coating not less than 275gm/m2 CPWD 12.1.3

1040.69

-

759.78

... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. Limpet washer complete, 0.8mm thick with zinc coating not less than 275gm/m2 CPWD 12.4.1

784

-

648.84

... More
WOOD WORK Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters., 32 mm thick including ISI marked Stainless Steel butt hinges with necessary screws PWD 9.21.2

52.29

-

1620

... More
40 mm thick including ISI marked Stainless Steel butt hinges with necessary screws PWD 9.21.1

27.3

-

1830

... More
PAINTWORK Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). CPWD 13.46.1

2146.38

-

136.77

... More
Finishing walls with textured exterior paint of required shade: New work (Two or more coat applied @ 3.28 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). CPWD 13.45.1 New

3305.25

-

130

... More
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works CPWD 13.50.3 New 641

280

-

42.09

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work CPWD 13.61.1

332

-

100.91

... More
Finishing walls with POP of approved brand and manufacture and of requuired shade and undecorated wall surface to ive even shade over, including curing and cost of material, labour, T&P etc required for proper completion of work. New

1686

-

120

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, Two or more coats on new work CPWD 13.60.1

569

-

106.81

... More
Providing catwalks - work in steel work welded in built-up sections, framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. PWD Sr. No.LKO

26.7

-

5850

... More
(PART-B) ALUMINIUM WORK: Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) CPWD 21.3.2

4.41

-

1076.5

... More
With float glass panes of 8 mm thickness (weight not less than 20 kg/ sqm) CPWD 21.3.3

18.74

-

1214.29

... More
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-incharge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). CPWD 21.5

120

-

557.04

... More
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium CPWD 21.15.2

22.5

-

61.62

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately), Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made., Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) CPWD 9.147D.1

69.12

-

5571.53

... More
NEW TECHNOLOGIES AND MATERIALS Providing and fixing in position false ceiling and side cladding with single layer of 6mm thick Everest Designer Board with and including propriority frame suspended system and necessary scaffoldingas required complete. (Market Price)

182.17

-

1266

... More
Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineer-in-charge all complete., With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles CPWD 26.24.1

466.03

-

2272.58

... More
Accoustic treatment for low frequency Absorption for walls (Market Price)

182.16

-

9094

... More
Accoustic treatment for high frequency Absorption for walls (Market Price)

466

-

8906

... More
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from MS sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 22 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the angle hangers of 25 x 25 x 0.55 mm of required length and other end of angle hanger being fixed with nut and botls to G.I. channels 45 x 15 x 0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick button wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450 mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick x 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive all screws @ 230 mm interval including jointing and fixing to a flush finish of tapered PWD 12.52

935.56

-

1550

... More
Providing and laying Tufted Loop pile carpet (1800 gm/sqm) of 100%solution dyed, 100% BCF duralux Olefin,yarn weight 26 Oz per sqYd. with secondary backing with action back,gauge 1/10", pile height 4mm. ( Heritage / broadloom / Grand Canion make ) including fixing with approved quality adhesive etc. complete as per direction of Engineer-in - charge (Market Price)

94.321

-

295.01

... More
Auditorium Chairs ISRO-AUDI or INFOTECHAUDI of Featherlite or equivalent of Godrej/ Blowplast (Market Price)

200

-

12000

... More
Providing and fixing of seating back , seat and arm-rest using high-density super-soft (PU)using members of effective fire retardent steel frame. One piece cold foam moulding, finished with enamel using paint approved by the architect. Fabric:using fire retardant, anti-pollution, fade resistant of dsign approved by the architect. Arm rest: using logs and overcoated PU. Tablet: using high density MDF and cold pressing fire proofing panels around PU edged. The work include transportation, lead lift, etc. .Work to be executed as per the directions of engineer-in-charge and approved by the architect. (Market Price)

200

-

5200

... More
Stage Proscenium: As per proposed design. GI structure with panelling and valence of approved make. (Market Price)

1

-

1400000

... More
Wood wool panelling on Proscenium (inner side of stage) (Market Price)

1

-

350000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.