Agra Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Agra Development Authority - ADA Tender
Bridge Construction
Civil And Construction
Civil Works Others
Eprocure
Opening Date13 Jun 2024
Closing Date25 Jun 2024
Tender Amount₹ 1,25,76,000
Costs
EMD
₹ 2,51,600Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ADAA_927851_1Bid Award Id
ViewTender No
01/em/2024-25Tender Authority
Agra Development Authority ViewPurchaser Address
-Website
http://http://www.adaagra.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, Installation, Testing and Commissioning of state-of-the-art laser-cut Decorative poles are made of Mild Steel total height of 4mtr with predefined pattern as per drawing. .50W top spot light, also with 50W diffused light, enclosed by symmtric led lens with durable proper silicone rubber gasket. SCDM5 to avoid color deviation. All the LED to be tested LM80 test method. Fitting is IP66, wired with Branded OSRAM, seoul or equivalent make LED and Fulham or osram constant current driver with efficiency 80%, power factor 0.9, THD=10%.Operating temp range of 0-50deg C. The CCT of the led will be 3000K as required by the project. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. Fitting is IP 65 complete in all aspects. in pole Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation. Pole coated with proper powder coating process and cured. Pole is complete in all aspects with all accessories except foundation bolt. 5 Years Warranty. The work includes all the installation & mounting accessories, as approved by the department.
12
834000
69500
Supply, Installation, testing & commissioning of complete Chemical Earth Pit System with inspection chamber and cover, 3m earth electrode, along with all the necessary accessories such as 25mm double compression Cable glands with Lugs, 19mm PG Cable glands with Lugs etc.
2
39500
19750
Supply and laying of 4.0 sq. mm x 3 core ISI marked, FRLS PVC insulated, single core copper conductor cable in exising conduits with proper connections, glands, etc.
1200
330000
275
Supply and Laying of one number 3.5core x25 sq mm Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
100
37300
373
Supply and fixing IP67 weatherproof box for Power Supply with cable glands at input and output of the box, size of the box should be sufficient to accommodate the power supply of the fixtures
36
40860
1135
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898:2002 but without enclosures :- 6 Amp to 32 Amp Rating, SINGLE POLE (SP)
400
32400
81
For 40 Amps. Rating only. DOUBLE POLE (DP)
50
16800
336
Supplying of approved make, powder coated Vertical TPN MCB DB Metal Double Door with MCCB 100A TP 10kA as incomer and space for SP/TP MCBs as outgoing (without MCBs) inclusive of busbar &connections etc without MCB: 4 way with MCCB
2
13538
6769
8 way with MCCB
2
14356
7178
12 way with MCCB
2
17374
8687
Stand Alone DMX controller with Zone management and 16-bit channel management. RDM Enabled. Extensive external triggering operations via Dry Contact ports, TCP/UDP along with Calendar Triggers. Ethernet Integration. IOS/Android APP based wireless control. 1024 DMX channel control with an option to get a paid upgrade to 2048 channels. DC5-5.5V Input via external adaptor. Up to 32BG memory. Using light show authoring software to select from standard 10 effects, adjust effect settings such as color, speed, and brightness.
1
275000
275000
DMX converter with 3 and 5 pin XLR points for programming of lights .
2
332000
166000
DMX Splitter- The DMX-512 splitter shall have minimum one DMX input and six DMX output connections, the sockets being standard 5-pin AXR connectors. The opto isolated DMX-512 splitter shall have a power on LED and DMX active LED indication on the front panel. The opto isolated DMX-512 splitter input shall be internally terminated.
4
226800
56700
DMX Cable 18 AWG 18/0.20 mm x 2 Core ATC copper conductor PE insulated, core twisted in a circular form inner sheathed with moisture proof polymer, beard shieleded (80% with ATC Copper, outter jacket with matt finished PVC.
800
162400
203
Supply, installation, testing and commissioning of stand mounted panel made of 16 SWG GI sheet, double door and duly pretreated and power coated to make it weather proof. Astonomical timer MCCB 65 A , switch 3 pole TPN.
1
38946
38946