Tube Investments Of India Limited Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Tube Investments Of India Limited - TIDC Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date31 Jan 2024
Closing Date21 Feb 2024
Tender Amount₹ 1,04,52,257 
Notes
Download

Costs

Summary

Setting Up Of Mini Tea Processing Factory At Machmara Tea Estate Under Machmara Adc Village Of Pecharthal Rd Block Under Unakoti District(2nd Call))

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavating, supplying and filling of local earth (includingroyalty) by mechanical transport upto a lead of 5 km alsoincluding ramming and watering of the earth in layers notexceeding 20 cm in trenches, plinth, sides of foundationetc. complete.

69.68

21091

302.7

... More
Extra for additional lift of 1.5m or part thereof-All kinds of soil

69.67

3469

49.8

... More
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts includingspreading in horizontal layers, watering, grading torequired slope, ramming, consolidating and compactingeach layer by using plate compactor or by any suitablemethod complete.F1+F2+FLOOR

22.17

19671

887.5

... More
Treatment of soil under plinth filling using chemicalemulsion @ one litre per hole, 300 mm apart includingdrilling 12 mm diameter holes and plugging with sandfilling:2.21.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

232.26

22041

94.9

... More
Cement Concrete

-

-

-

... More
Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stoneaggregate 20 mm nominal size) PCC BELOW TIE F1 + F2 + FLOOR

25.35

250297

9872.1

... More
Providing and laying cement concrete in retainingwalls, return walls (any thick-ness) includingattached pilasters, columns, piers, abutmets, pillars,posts, struts, buttresses, string or lacing courses,parapets, coping bed blocks, anchor blocks, plainwindow sills, fillets, sunken floor etc. upto floor fivelevel, excluding the cost of centring shuttering andfinishing -1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)

0.29

3167

11075.8

... More
Centering shuttering including struttings, proppingetc. and removal of form work for:

-

-

-

... More
Foundations, footings, bases for columns. F1+F2

14.18

3382

238.6

... More
Making plinth protection 50mm thick of cementconcrete 1:3:6 (1 cement : 3 fine sand : 6 graded wellburnt brick aggregate 20 mm nominal size) over75mm bed of dry brick ballast 40mm nominal sizewell rammed and consolidated and grouted with fine sand including finishing the top smooth

81

65650

810.5

... More
Retaining walls, return walls, walls (any thickness)including attached pilasters, but-tresses plinth andstring courses fillets etc.

19.04

5870

308.4

... More
Reinforced cement concrete

-

-

-

... More
Providing and laying in position specified grade ofreinforced cement concrete excluding the cost ofcentring, shuttering, finishing and reinforcement--All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size)

84.62

928626

10974.6

... More
Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor fivelevel excluding cost of centring, shuttering, finishing and reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)

1.96

23064

11791.9

... More
Reinforced cement concrete work in beams, suspendedfloors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishingand reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size)

11.7

141612

12104.7

... More
Centering shuttering including struttings, propping etc. and removal of form work for

-

-

-

... More
Foundations, footings, bases for columns etc. for massconcrete with timber plank

55.62

14956

268.9

... More
Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply

3

1617

539

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply

45.72

17611

385.2

... More
Columns, Pillars, Piers, Abutments, Posts and Struts withshuttering ply

78.78

38050

483

... More
Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding allcomplete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more Footing 56.899 x85kg/cum=4836.415kg Beam 10.298 x180kg/cum=1853.64kg Floor & lintle17.419+1.956=19.375 x70kg/cum= 1356.25kg Roof =10.502 x120kg/cum=1260.24kg

9306.55

727771

78.2

... More
First class brick work in foundation and plinthincluding cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). side drain

22.5

199989

8888.4

... More
Half brick masonry work with first class bricks infoundation and plinth including cost of all materials asrequired complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).

9

10691

1187.9

... More
First class brick work in superstructure above plinthlevel & upto floor-five level including cost of allmaterials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ).pherifery wall

32.96

334139

10136.49

... More
Half brick masonry work with first class bricks insuperstructure upto floor five level including cost ofall materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ).

27.43

37389

1363.1

... More
Supplying and fixing rolling shutters of approved make,made of required size M.S. laths interlocked togetherthrough their entire length and jointed together at theend by end locks mounted on specially designed pipeshaft with brackets, side guides and arrangements forinside and outside locking with push and pull operationcomplete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S.top cover of required thickness for rolling shutters &with handles, hold fast including embedding in cementconcrete of required grade required for fixing in position,all necessary fittings, including applying of approvedsteel primer etc. complete as required:80x0.90 mm M.S. laths with 0.90 mm thick top cover.

17.43

39149

2246.1

... More
Extra for providing & fixing mechanical device chain andcrank operation for operating rolling shutters ofapproved make complete as required:-9.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area.

10.83

12236

1129.9

... More
Providing, fabricating, transporting, assembling anderection in position of Steel members for steel colunms,built up beams using structural tubular sections (round,square or rectangular hollow tubes etc. confirming to IS4923 / IS 1161, Yield strength 310 MPa as per latest IS Code)to the required profile & shape as called for as per thedrawing & specifications and of approved make including the shear connectors /studs and fusion weld to top ofhorizontal member. This item also includes prepration ofshop drawings and their approval, necessary templates,adequate temporary supports, scaffolding & staging, allcutting, grinding, sliding & all labour tools, plants &equipments & operations etc. required to complete the jobas per drawing & specification. Every precaution to be takento prevent rusting of sections. This item also includes alltest on materials & welded fabricated parts as perspecification and direction of Engineer - in - ChargeTemporary bolts & nuts ( grade EN 8 ) to be used duringassembling & shall be removed before site erection. All siteerection bolts shall be HSFG type only. The item to includecost of sand blasting on materials, application of primer andepoxy paint in internal & external in fabrication shop &final painting on site including all touch up works aftererection as per technical specification.

-

-

-

... More
Scope of work includes: i) Design & fabrication of any additional temporary structureincluding all type of lifting brackets, supporting brackets ,which will be required for transportion & erection in position / launching offabrication part or complete element in position.ii) Making provision & arrangement for required opening / inserts forfixing lights fixtures & funning cable conduits.iii) All incidentials labour, equipement & plants required to execute &complete the job from fabrication to erection at final position as perdrawing, specification & direction of Engineer - in -Charge.iv) Cleaning & removing of all spoil, temporary arrangementa forcasting of deck slab/roofing.v) All safety measures required to execute & complete the work.vi) Procurement of all materials from approved manufactures &fabrication. Complete methodology for structural steel work, Nameof workshop for fabrication works, Testing facilities & erectionprocedures etc.to be intimated for approval of Engineer - in - Charge.vii) The provision of temporary bearing / sand jacks for supportingsteel members during erection.viii) Provision of stability during erection against wind load or any other type of loading on structural steel members during erection.ix) Measurement shall be only for structural steel which is erected &is part of permanent structure & paid as per approved shop drawings.All wastages, temporary works, Jigs, temporary assembly bolts etc.are deemed to be included in rates. No allowence or increse in weightfor welding , nuts & bolts etc will be applicable.

12607.31

1720897

136.5

... More
Providing testing & tigthtening of high strength frictiongrip bolts (HSFG bolts ) of class / grade EN 8 up to proofload as per IS 4000, including required threading, using automatic calibrated torque wrench at all locations & allheights and their compitable nuts & washers all completerequired to execute the job. All HSFG bolts, nuts &washers confirming to IS 1367, IS 6610 & IS 4000 shall beused. The measurement shall be made for completeassembly of bolt, nut & compitable washers used inpermanent works.

100

23830

238.3

... More
Steel work welded in built up section/framed workincluding cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer usingsteel etc. complete as required:-In stringers, treads, landing etc. of stair cases including useof chequered plate wherever required, all complete.

508.73

48532

95.4

... More
Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.

865.07

71195

82.3

... More
Providing and fixing M.S. round holding down bolts withnuts and wahser plates complete as per standard design.

280

21420

76.5

... More
Providing and fixing in position 1mm thick M.S. sheetsliding-shutters with frame and diagonal braces of40x40x6mm angle iron and 3mm M.S. gusset plates at thejunction and corners 25mm dia pulley, 40x40x6mmangle and T-iron guide sufficiently long at the top andbottom respectively, channels & with bolts, nuts, rivets,locking arrangement, stoppers, handles, hold fastincluding embedding in cement concrete of requiredgrade for fixing in position, all necessary fittings,including applying a priming coat of approved steelprimer etc. complete as required.

43.68

181678

4159.3

... More
Providing and fixing angle iron frames for doors,windows and ventilators of mild steel Angle sections ofsize 35x35x5 mm, joints mitred and welded by angle iron35x35x5 mm or 35x 5 mm flat pieces to the existing Tironframe or to the wall with dash fastener, includingfixing of necessary butt hinges and screws and applyinga priming coat of approved steel primer, all complete as per the direction of Engineer-in-Charge. Ventilators 21x 1.50x0.60= 15kg /sqm

283.5

25231

89

... More
Supply & installation of pre-painted Galvalume sheetsfor roofing/cladding (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) in550mpa steel grade, made out of Cold Rolled Steelcoated with Zinc-Aluminium alloy coating of 43.5% Zn,55% Al and 1.5% Silicon confirming to ASTMA792/A792M and AS1397, Alloy coating AZ150/AZ70,colour coated with high quality Polyester coating, topcoated of modified polyester of 20 micron, back sidecoat of 5 micron, having epoxy primer coat of 5 micronon both side. Sheet should have protective guard filmof 25 microns minimum to avoid scratches whiletransportation and should be supplied in singlelength upto 12 metre or as desired by Engineer-incharge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55mm) with EPDMwashers filled with white lead complete upto anypitch in horizontal/ vertical or curved surfacesexcluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever required.0.45mm thickness

532.64

397403

746.1

... More
Supply & installation of pre-painted Galvalume sheetsroofing accessories in 550mpa steel steel grade, madeout of Cold rolled steel coated with Zinc-Aluminiumalloy coating of 43.5% Zn, 55% Al and 1.5% Siliconconfirming to AASTM A792/A792M and AS1397, Alloycoating AZ150/AZ70, colour coated with high qualitypolyester coating, top coated of modified polyester of20 micron, back side coat of 5 micron, having epoxyprimer coat of 5 micron on both side. Sheet should haveprotective guard film of 25 microns minimum toavoid scratches while transportation. Sheet shouldhave protective guard film of 25 microns minimumto avoid scratches while transportation. The sheetshall be fixed using self drilling /self tapping screwswith EPDM washers complete forRidges/ Valley/ Gutter/Flashing of width 610mm: 0.45mm thickness

32

13200

412.5

... More
Providing & fixing UV stabilised fiberglassreinforced plastic sheet roofing up to any pitchincluding fixing with polymer coated 'J' or 'L' hooks,bolts & nuts 8mm dia. G.I plain/bitumen washerscomplete but excluding the cost of purlins, rafters,trusses etc. The sheets shall be manufactured out of2400 TEX panel rovigs incorporating minimum 0.3%Ultra-violet stabiliser in resin system underapproximately 2400 psi and hot cured. They shall be ofuniform pigmentation and thickness without airpockets and shall conform to IS 10192 and IS12866.The sheets shall be opaque or translucent, clearor pigmented, textured or smooth as specified. 11.12.12mm thick corrugated (2.5" or 4.2" or 6") or step-down(2"or 3"or 6") as specified

89.67

95902

1069.5

... More
Providing and fixing false ceiling at all height includingproviding and fixing of frame work made of specialsections, power pressed from M.S. sheets and galvanizedwith zinc coating of 120 gms/sqm (both side inclusive)as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and37mm, at 1200 mm centre to centre, one flange fixed tothe ceiling with dash fastener 12.5 mm dia x 50mm longwith 6mm dia bolts, other flange of cleat fixed to theangle hangers of 25x10x0.50 mm of required lengthwith nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200 mm centre to centre,to which the ceiling section 0.5 mm thick bottom wedgeof 80 mm with tapered flanges of 26 mm each havinglips of 10.5 mm, at 450 mm centre to centre, shall befixed in a direction erpendicular to G.I. intermediatechannel with connecting clips made out of 2.64 mm diax 230 mm long G.I. wire at every junction, includingfixing perimeter channels 0.5 mm thick 27 mm highhaving flanges of 20 mm and 30 mm long, the perimeterof ceiling fixed to wall/partition with the help of rawlplugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsumboard to ceiling section and perimeter channel with thehelp of dry wall screws of size 3.5 x 25 mm at 230 mmc/c, including jointing and finishing to a flush finish oftapered and square edges of the board with recommended jointing compound of joint and two coats of primer su,i tjoabinletinfogr tbapoaersd ,, all asper manufacturer's specification and also including thecost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeterchannels suitably fixed, all complete as per drawings,specification and direction of the Engineer in Charge butexcluding the cost of painting with :

36.16

36815

1018.1

... More
Providing and laying cement concrete 1:2:4 (1 cement : 2fine sand : 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cementslurry, rounding of edges and strips etc. complete.40 mm thick with 20 mm stone aggregate

232.26

128717

554.2

... More
Providing and laying ceramic floor tiles in different sizes(thickness to be specified by the manufacturer) of 1stquality conforming to IS : 15622 - 2017 of approvedmake in colours such as White, Ivory, Grey, Fume RedBrown, laid over 20 mm thick cement mortar 1:4 (1cement : 4 fine sand), Jointing with grey cement slurry @3.3 kg/sqm including pointing the joints with whitecement and matching pigment etc. complete.Anti-Skid Tiles cramic Tiles 1st quality 300 x 300mm in all shades and designs

61.42

51669

841.2

... More
Providing and fixing 1st quality ceramic glazed wall tiles(minimum 200 x 300) conforming to IS : 15622 - 2017(thickness to be specified by the manufacturer) ofapproved make in all colours, shades of any size asapproved by Engineer-in-charge in skirting, risers ofsteps and dados, laid over 12 mm thick bed of cementmortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with whitecement mixed with pigment of atching shade complete.

36

28512

792

... More
Finishing work 12 mm cement plaster of mix Cement mortar 1:4 (1 cement : 4 fine sand) partion wall, pherifery wall inside, drain

408.6

71423

174.8

... More
15 mm cement plaster on the rough side of single orhalf brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) , wall out side, partion wall

228.6

46497

203.4

... More
Neat cement punning.

484.08

21832

45.1

... More
Providing and applying white cement based putty ofaverage thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface to preparethe surface even and smooth complete.

14.4

1463

101.6

... More
Distempering with oil bound washable distemper ofapproved brand and manufacture to give an even shade[Payment shall be made after submission of TestCertificate issued by the Manufacturer] :12.24.1 New work ( two or more coats) over and including waterthinnable priming coat with cement primer.

91.44

8750

95.7

... More
Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture [Payment shall be made after submission of TestCertificate issued by the Manufacturer] :12.30.1 New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/10 sqm)

91.44

10917

119.4

... More
Painting with synthetic enamel paint of approved brandand manufacture to give an even shade [Payment shallbe made after submission of Test Certificate issued bythe Manufacturer]:Two or more coats on new work

1000

82800

82.8

... More
Designing, fabricating, testing, installing and fixing inposition Curtain Wall with Aluminium Composite PanelCladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights andall levels etc. including: (a) Structural analysis & design and preparation of shopdrawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertightincluding checking of all the structural and functionaldesign. (b) Providing, fabricating and supplying and fixing panelsof aluminium composite panel cladding in pan shape inmetalic colour of approved shades made out of aluminium composite panel material of approved thickness andspecification. The aluminium composite panel claddingsheet shall be coil coated, with Kynar 500 based PVDF /Lumiflon based fluoropolymer resin coating of approvedcolour and shade on face # 1 and polymer (Service) coatingon face # 2 as specified using stainless steel screws, nuts,bolts, washers, cleats, weather silicone sealant, backer rodsetc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MSwith Hot Dip Galvanised with serrations and serratedwashers to arrest the wind load movement, fasteners, SS316 Pins and anchor bolts of approved make in SS 316,Nylon separators to prevent bi-metallic contacts allcomplete required to perform as per specification anddrawing The item includes cost of all material & labourcomponent, the cost of all mock ups at site, cost of allsamples of the individual components for testing in an approved laboratory, field tests on the assembled workingcurtain wall with aluminium composite panel cladding,cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of thebuilding for occupation. Base frame work for ACP claddingis payable under the relevant aluminium item.s TheContractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete , as per the Architecturaldrawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual areaon the external face of the curtain wall with AluminumComposite Panel Cladding (including width of groove) shallbe measured in sqm. up to two decimal places."

-

-

-

... More
Aluminium Composite Panels of 4mm total thickness withTop coil – 0.50mm AA3003 / AA3105 / AA5005 Grademanufactured as per IS-737 1986, FR Grade Class B1 with3mm Mineral Core with minimum 70-72% Inorganiccontent (Aluminium Hydroxide and Magnesium Hydroxide)28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501-1, class B1,and Bottom coil – 0.50mmAA3003 / AA3105 / AA5005 Grade, anufactured as per IS-737 1986 with minimum 25 microns lead free PVDFCoating conforming to AAMA2605 on top coil and Servicecoating on Back Coil (4 - 6 microns) having minimum panelweight of 7.5 Kg/m2

3

12898

4299.6

... More
Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded builtup standard tubular sections/ appropriate Z sectionsand other sections of approved make conforming toIS: 733 and IS : 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up ofgaps at junctions, i.e. at top, bottom and sides withrequired EPDM rubber/neoprene gasket etc. Aluminiumsections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle, aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as perarchitectural drawing and the directionof Engineer in charge.(Glazing and paneling and dashfasteners to be paid for separately) :-

-

-

-

... More
For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed torequired shade according to IS: 1868, Minimum anodic coating of grade AC 15).

936

374587

400.2

... More
For shutters of doors, windows & ventilators includingproviding and fixing hinges / pivots and makingprovision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately ):-Polyester powder coated aluminium ( minimum thicknessof polyester powder coating of 50 micron ). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).

77.76

36671

471.6

... More
Providing and fixing bright finished brass hangingtype floor door stopper with necessary screws, etc.complete.

1

111

111.6

... More
Providing and fixing aluminium sliding door bolts ISImarked anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed torequired colour or shade with nuts and screws etc.complete :300x16 mm

1

259

259.9

... More
Providing and fixing chromium plated brass handles with necessary screws etc. complete :125 mm

4

958

239.6

... More
Providing and fixing bright finished brass night latchincluding necessary screws etc. complete (best makeof approved quality).

4

3920

980.2

... More
Providing and fixing IS : 3564 marked aluminiumextruded section body tubular type universalhydraulic door closer with double speed adjustmentwith necessary accessories and screws etc. complete.

2

2189

1094.5

... More
Providing and fixing 12 mm thick prelaminated threelayer medium density (exterior grade ) particle boardgrade-I, type II conforming to IS : 12823 bonded withphenol formaldehyde synthetic resin, of approved brandand manufacture in panelling fixed in aluminium doors,windows, shutters and partition frames with C.P. brass /stainless steel screws all complete as per architectural drawing and the direction of Engineer-in-charge :- Prelaminated particle board of approved quality with decorative lamination on both side.

72

94312

1309.9

... More
Providing and fixing glazing of approved quality inaluminium doors, windows, ventilator, shutters andpartition etc. with EPDM rubber / neoprene gasket etc.complete as per architectural drawing and the directionof Engineer-in-charge (Cost of snap beading shall be paidin basic item) :- With float glass panes With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm )

45

57834

1285.2

... More
Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion:

-

-

-

... More
Single socketed pipe - 75 mm OD

2

316

158.3

... More
Single socketed pipe - 110 mm OD

3

805

268.5

... More
Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water pipes conforming to IS : 13592 Type-Aincluding jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansio

-

-

-

... More
Coupler 75 mm

1

72

72.3

... More
Coupler 110 mm

1

123

123.6

... More
Single equal tee without door 75x75x75 mm

1

138

138.6

... More
Single equal tee without door 110x110x110mm

1

224

224.4

... More
Single equal tee with door 75x75x75 mm

1

148

148.8

... More
Single equal tee with door 110x110x110mm

1

231

231.2

... More
Bend 87.5° 75mm

1

77

77.6

... More
Bend 87.5° 110 mm

1

140

140.9

... More
Providing and fixing unplasticised -PVC pipe clips ofapproved design to unplasticised - PVC rain waterpipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required lengthincluding cutting brick work and fixing with cementmortar 1 : 4 (1cement : 4 fine sand) making good thewall etc. complete.

-

-

-

... More
75mm

3

563

187.8

... More
110mm

3

571

190.5

... More
Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.

-

-

-

... More
75mm

1

84

84.8

... More
110mm

1

97

97.2

... More
Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square orround bars etc. all complete.Fixed to openings /wooden frames with rawl plugsscrews etc.

252

31852

126.4

... More
Providing & fitting fixing in position steel decking sheet materials GICC,GLCC,GI,GLTensile strength 240 Mpato 350Mpa thickness 0.60to 2mm coating 70GSM to 550GSM color coating SMP,PVDF,RMP,EXOXySDP,AND HDF etc. all complete as per the direction of Engineer-in-Charge.complete. 1.00mm thckness 10.71 kg/sqm for below slab area

512.71

69944

136.42

... More
Electrical Work

-

-

-

... More
Supplying Installation testing & comissoning of Distribution Transformer : 3Ø 200 KVA Delta-Star (DYN11)11/0.433 KV,Frequency OIL COOLED/ ONAN,Off load,Aluminium wound ,as per BIS level-2

1

258750

258750

... More
Supplying & fixing of Lightining Arrester :9 Kv, 5 KA Metal Oxide Lightning Arresters (discharge class shall be 3 as per. IS-3070 part-II) as per relevant standard, one number per phase shall be fitted

3

9023

3007.67

... More
Supplying,Installation & Testing of Poles & its supporting Accessries

-

-

-

... More
PSC Poles 9.75 Mtrs

4

27883

6970.8

... More
Supplying of 11KV Pin Insulator(Poly)with G.I. pin,bolts & nuts coach screw ets. As required & as directed by the department.

6

4014

669

... More
Supplying of 11KV Disc Insulator(Poly) 45 KN with hard wire fitting etc. as required directed by the department

6

5928

988

... More
11KV, 150 Amp D.O. fuse set complete as required & as directed by the department.

1

3803

3803

... More
Fitting & fixing for weasel at pole (PG clamp) complete as required and as directed by the department.

22

2596

118

... More
H.T. stay set complete (Galvanized) with 19 mm dia x 1.8 m long stay rod anchor plat of size 30cm x 30cm x 6.4mm, thimble stay clamps,turns buckle(19mm x 60cm) 7/3.15 mm dia G.I stay wire

2

5628

2814

... More
15/6 Amp aerial fuse complete as required and as directed by the department

3

222

74

... More
11 KV 400 Amp Gang operated switch with all accessories complete as required and as directed by the department.

1

9080

9080

... More
H.T. Danger Plate complete as required and as directed by the department.

2

160

80

... More
Main MCCB with Rated Current & Breaking Capacity

-

-

-

... More
Rated 320 Amp, Breaking Capacity 36 KA 4 Poles MCCB (Moulded Case Circuit breaker)

1

32191

32191

... More
Rated 250 Amp, Breaking Capacity 36 KA 4 Poles MCCB (Moulded Case Circuit breaker)

1

21051

21051.5

... More
X installation & erection

1

7986

7986.44

... More
MCCB/TPN/MCB/CONT/OLR For CTC & CFM-65 HP (48.49 KW)

-

-

-

... More
MCCB (Moulded Case Circuit Breaker) 4P- 200 Amp

2

22487

11243.56

... More
TPN Switch - 250 Amp

2

21459

10729.52

... More
MCB (Miniature Circuit Breaker) TP-6 Amp

12

11928

994

... More
CONT (Contactor)3 pole with 1NO+1NC Aux. Contact. 18 Amp/LCID 18

6

9976

1662.82

... More
CONT (Contactor)3 pole with 1NO+1NC Aux. Contact. 22 Amp/LCID 25

2

3325

1662.82

... More
CONT (Contactor)3 pole with 1NO+1NC Aux. Contact. 40 Amp/LCID 40

2

13569

6784.76

... More
OLR (Overload Relays) 3.5 Amp - 5 Amp/4-6 LRD10

6

21000

3500

... More
OLR (Overload Relays) 11 Amp - 15 Amp/9-13 LRD 16

2

15000

7500

... More
OLR (Overload Relays) 5.3 Amp - 8 Amp/5.5-8 LRD 12

2

11000

5500

... More
V installation and erection

1

7436

7436.62

... More
MCCB/TPN/MCB/CONT/OLR For Dryer-39 HP (29.09 KW)

-

-

-

... More
MCCB (Moulded Case Circuit Breaker) 4P- 100 Amp

2

12493

6246.58

... More
TPN Switch - 100 Amp

2

21459

10729.52

... More
MCB (Miniature Circuit Breaker) TP-63 Amp

4

6134

1533.6

... More
CONT. (CONTACTORS) 18 Amp/LCID 18

2

3325

1662.82

... More
CONT. (CONTACTORS) 22 Amp/LCID 25

3

4988

1662.82

... More
CONT. (CONTACTORS) 40 Amp/LCID 40

4

27139

6784.76

... More
OLR (Overload Relays) 18 Amp - 25 Amp/16-24 LRD22

2

5000

2500

... More
OLR (Overload Relays) 7 Amp - 10 Amp/7-10 LRD 14

2

8000

4000

... More
OLR (Overload Relays) 5.5 Amp - 9 Amp/5.5 -8 LRD 12

2

7000

3500

... More
Zinstallation & erection

1

5793

5793.02

... More
MCCB/TPN/MCB/CONT/OLR For Sorting-20 HP (14.92 KW)

-

-

-

... More
MCCB(Moulded Case Circuit Breaker)4P-100 Amp

2

12493

6246.58

... More
TPN Switch - 100 Amp

2

21459

10729.52

... More
MCB (Miniature Circuit Breaker) TP-16 Amp

5

4970

994

... More
CONT (Contactor) - 18 Amp

5

8314

1662.82

... More
OLR (Overload Relays) 4.5 Amp - 6.3 Amp

4

12000

3000

... More
OLR (Overload Relays) 4.5 Amp - 5.2 Amp

2

9000

4500

... More
W installation and erection

1

4069

4069.94

... More
MCCB/TPN/MCB/CONT/OLR For Withering Trough & Monorail-17 HP (12.682 KW)

-

-

-

... More
MCCB(Moulded Case Circuit Breaker)4P-100 Amp

2

12493

6246.58

... More
TPN Switch - 100 Amp

2

21459

10729.52

... More
MCB (Miniature Circuit Breaker) TP-6 Amp

8

7952

994

... More
CONTACTORS (CONT) CONT (Contactor) - 18 Amp

3

4988

1662.82

... More
CONT (Contactor) - 22 Amp/LCID 25

5

8314

1662.82

... More
OLR (Overload Relays) OLR 3.5 Amp - 6 Amp/4-6A LRD10

3

13500

4500

... More
OLR (Overload Relays) OLR 1.8Amp - 2.5 Amp/1.6-2.5A LRD07

5

17500

3500

... More
V installation and erection

1

4394

4394.36

... More
MCCB/TPN/MCB/CONT/OLR For Factory Lighting 4.02 HP (3.00 KW)

-

-

-

... More
MCCB(Moulded Case Circuit Breaker)4P-125 Amp

2

15852

7926.44

... More
TPN Switch - 200 Amp

2

38019

19009.54

... More
MCB (Miniature Circuit Breaker) TP-16 Amp

5

4970

994

... More
CONT (Contactor) - 18 Amp

5

8314

1662.82

... More
OLR 4.5 Amp - 6.3 Amp/4-6 A LRD10

5

17500

3500

... More
U installation and erection

1

4963

4963.92

... More
Supplying of Air/Water Cooled DG Set (Diesel Generator) 125 KVA 3-Phase Approx size (3200 x1300x1805 mm) ,220/415V

1

815000

815000

... More
installation, Testing and commissioning

1

122250

122250

... More
Supply of LT Power Cables with Copper Armoured

-

-

-

... More
3.5 Core X 150 SQ. mm PVC sheathed Armoured cable

10

10155

1015.56

... More
3.5 Core X 185 SQ. mm PVC sheathed Armoured cable

10

12550

1255

... More
3.5 Core X 35 SQ. mm PVC sheathed Armoured cable

10

3152

315.24

... More
4 Core X 10 SQ. mm Aluminium Armoured

10

1831

183.18

... More
T installation & erection

10

4153

415.35

... More
Supply & erection of Capacitor Bank & its using MCB with All acessories as specified & directed by the deptt.: 125 Amp, 4P MCB-2 nos/10 KVAR-2 nos/20KVAR-3 nos.

1

135390

135390

... More
Supply & installation of Plate Earthing Materials

-

-

-

... More
G.I. Pipe (Perforated 40 mm dia & 3.00 Meter long ) heavy duty G.I. with necessary fitting such as Socket,Tee,elbow,nipple and 65 mm x50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx 6mm hinged cover C.I. earth plate complete with digging of earth pit,construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.

12

64104

5342

... More
Copper Plate (size 600 mm x 600 mm x 3 mm) with necessary Accessories such as Socket,Tee,elbow,nipple etc.

4

52872

13218

... More
Materials are using for earthing like 5kg Salt & 64 Kg Charcols in pipe earthing to provide low impedance ground.

16

44864

2804

... More
Copper strip (size 25x4 mm ) with all accessories like Brass nuts & bolts,screwa etc including soldering,reventing & making necessary connection etc.

50

37100

742

... More
Wiring of Light/Fan/Call bell point with PVC insulated unsheathed Industrial (Multistrand)cable FR IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts..

-

-

-

... More
Medium point up to 6 Mtrs length

14

10374

741

... More
Long point up to 10 Mtrs Length

40

41480

1037

... More
Supplying including installation,connection as aproved by the Dept.,testing and comissioning of JET MONOBLOCK PUMP SET Complete as directed and specified by the deptt.

-

-

-

... More
1 HP single phase jet monoblock two stage pump set 2900 rpm with DOL starter.

1

18499

18499

... More
2 HP single phase jet monoblock two stage pump set 2900 rpm with DOL starter.

1

23309

23309

... More
Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -Cable size 6 sq.mm

10

13490

1349

... More
Supplying fitting & comissioning of panel board as specified and directed by the deptt.

-

-

-

... More
Feeder Pillar Panel board

1

68115

68115

... More
Main Panel board

1

331660

331660

... More
CTC Panel board

1

247940

247940

... More
Capacitor Panel board

1

169651

169651

... More
Sorting Panel board

1

104049

104049

... More
VFD Dryer Panel board

1

161163

161163

... More
Weithering Trough & Monrail Panel board

1

135779

135779

... More
CFM Panel board

1

125625

125625

... More
Supply & Laying of following size PVC/XLPE insulated and PVC sheathed Copper Conductor Armoured Cable-2XWY/2XFY

-

-

-

... More
3 Core X 4 sq.mm Copper armoured U.G. Cable

10

3270

327

... More
3 Core X 6 sq.mm Copper armoured U.G. Cable

10

3300

330

... More
3 Core X 10 sq.mm Copper armoured U.G. Cable

10

3720

372

... More
3.5 Core x 50 sq.mm Copper armoured U.G. Cable

10

6520

652

... More
3.5 Core x 95 sq.mm Copper armoured U.G. Cable

10

9720

972

... More
3.5 Core x 300 sq.mm Copper armoured U.G. Cable

10

23720

2372

... More
Miscleneous items (finishing items like wall putty/ Tap/paint/Extra bolt & screws etc.)

1

10000

10000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.