Tripura State Electricity Corporation Limited Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Tripura State Electricity Corporation Limited - TSECL Tender

Works
Eprocure
Opening Date29 Mar 2019
Closing Date24 Apr 2019
Tender Amount₹ 1,05,76,205 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
( a )Supply of 8.0 mtr. long PCC pole conforming to relevant ISS specification direct in earth including excavation, refilling and ramming etc. as required complete. 1/6 th of the length of the pole to be embedded in earth.

53

-

-

... More
( a ) Supply of 9.0 mtr. long PCC pole conforming to relevant ISS specification direct in earth including excavation, refilling and ramming etc. as required complete. 1/6 th of the length of the pole to be embedded in earth.

46

-

-

... More
Supply of painted Stay Set complete( HT/LT) direct in earth with 16 mm. dia. 1.8 mtr. long painted stay rod, anchor plate of size 300 X 300 X 8 mm. thick, turn buckle of length 356 mm. with 300 mm. long threaded adjustable 16 mm. dia. MS rod , thimble, guy insulator as per IS specification, hot dip (heavy duty) galvanized stay stranded wire of size 7/2.5 mm. fastened with stay clamps as required. ( including supply of MS clamp & Nuts & Bolts as reqd) and Grouting of stay set with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required ( @ 0.119 Cum per stay set as per TSECL specification).

137

-

-

... More
Supply of 11 KV marked Danger Plate including supply on existing single/double Pole structure at a height of 4 mtr from the GL.

90

-

-

... More
Supply of 440V marked Danger Plate including supply on existing single/double Pole structure at a height of 4 mtr from the GL.

70

-

-

... More
Supply of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air brake switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of clamps, nuts and bolts as required.

19

-

-

... More
Supply of triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit foroperation in 11 KV, 50 Hz, AC system as per relevant IS specification along with Supply of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR.

19

-

-

... More
Supply of 9 KV, 5 KN single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Creepage distance 600 mm. conforming to ISS:3070/1985.

32

-

-

... More
( a ) Supply , Testing & commissioning of 3- Phase, 50 Hz, AC, Distribution Transformer as per attached technical specification,on Pole Mounted structure with necessary connections by ACSR from 11 KV line to Transformer via GOS & DOF. i) 25 KVA ; 11/0.433 KV

6

-

-

... More
ii) 63 KVA ; 11/0.433 KV

2

-

-

... More
iii) 100 KVA; 11/0.433KV

2

-

-

... More
iv) 200 KVA; 11/0.433KV

2

-

-

... More
Supply of Assorted size MS Channel/Angle100X50X50X6mm, 75 X 40 X 40 X 6 mm., MS channel 65 X 65 X 6 mm. , 50X50X6mm etc. arm on steel tubular pole or PCC pole or RS joist with 1 (one) no. or 2(two) nos. clamp of 50x6 mm. MS flat, nuts and bolts as required including painting with ready mixed primer of approved quality (two or more coats) and alluminium paint of approved quality on new works to give an even shade for cross-arm. as per direction of Eng-In-Charge.( including supply of MS clamp & Nuts & bolts as reqd):- a.)MS Channel (100X50X50X6 mm)

2.9

-

-

... More
c.) MS channel (75 X40X40X6mm )

2.4

-

-

... More
e.) MS Angle (65X65X6mm )

1.8

-

-

... More
p.)MS angle (50X50X6 mm)

1.9

-

-

... More
Supply of G.I. Straps and Bolts, 185 mm x 30 mm x 3 mm including Supply of Nuts & Bolts etc. as required with shackle insulator

300

-

-

... More
( a ) Supply as per attached Technical Specification ,Laying, hoisting & stringing of ACSR Conductor including binding, jumpering, etc. as reqd. & as per direction of Engineer-in-charge. i) 6/1/2.59 sqmm dia ACSR, Rabbit conductor.

22

-

-

... More
Supply of 8 G.!. wire as per ISS : 280/1978 amended latest with heavy coating as per ISS : 4826 I 1968 of tensile strength 55 to 95 Kgf /mm i/c fastening with cross arm & metallic parts for earth continuity wire and metal parts to earth electrode as per the direction of Engineer-in-charge.

0.85

-

-

... More
Supply of porcelain pin insulator for 11 KV system with mechanical strength 10 KN conforming to ISS:731/1971 on hot dip galvanized M.S forged 11 KV G.I pin complete with galvanized hexagonal nuts, G.I flat washer & G.I spring washer conforming to ISS: 2486(P-II)/1974.

150

-

-

... More
Supply of porcelain disc insulator ball and socket type for 11 KV system (EMS-45 KN) conforming to ISS:731/1971 in angle and dead end locations including tension fittings of EMS-45 KN to accommodate the relevant ACSR conductor size along with supply of nuts and bolts, washer etc. as requied in complete & as per direction of Engineer-in-charge.

150

-

-

... More
Supply of anti-climbing devices viz barbed wires on pole structures including supply of barbed wres in helical form 7.5 cm. apart starting from ground level (1.5 Kg. / pole) as per direction of Engineer-in-charge.

1

-

-

... More
Supply of Porcelain Shackle Insulator (90X75mm) or ( 115X100 mm) for LT system with mechanical strength of 5 KN conforming to ISS:731/1971 with hot dip galvanized M.S G.I Straps with bolts in complete (suitable for Rabbit/DOG conductor) as per direction of Eng-In-Charge.

165

-

-

... More
Supply of wooden plank (preferably karai wood) of size 24" X 10" X 1.5" for fixing of cut outs with supply of 2(two) nos. M.S. clamps of 50x6 mm MS flat Nuts & bolts as required to be erected on the steel tubular, pee pole as per direction of Engineer-in-charge.

14

-

-

... More
Providing of HT Protective cradle guard made of 8 SWG G.I. wire as per ISS : 280/1978 with latest amendment if any, heavy coating as per ISS : 4826 I/ 1968 of tensile strenath 55 to 95 kgf/sq.mm i/c suuply of 8 S.W.G. G.I Wire as required as per direction of Engineer-in-Charge.

2000

-

-

... More
Grouting of steel tubular poles with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shutterirtg as required.(@ 0.33 Cum per steel tubular pole as per TSECL specification ).

70

-

-

... More
Grouting of stay set with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shutterirtg as required.( @ 0.119 Cum per stay set as per TSECL specification)

32.3

-

-

... More
Supply of earthing set as per ISS : 3043 of 1966 and with upto date mendment having 2.5 mtr long G.I. pipe (IS I marked) of 40 mm diameter with holes Including a pair of clamps of 50 X 6 mm M.S. flat & 12 mm dia galvanized nuts & bolts long with alternate layers of salt & charcoal including supply of 8 SWG GI wire for earth connectivity as required.

126

-

-

... More
Applying priming coat with ready mixed primer of approved quality om steel pole and steel work including painting ( two or more coats) with alluminium paint of approved quality on new work to give an even shade ( TSR - 2013 )

136

-

-

... More
( a ) Making connection from Transformer LT side to overhead LT Line via fuse unit of unarmoured PVC cable 1100-V grade conforming to ISS: 1554 (P-I) /1988 of the following sizes and the cables shall be properly crimped by bimetallic lugs at contact areas as per direction of Engineer-in-charge:- i) PVC cable 4mm sq.

2

-

-

... More
ii) PVC cable 16mm sq.

0.25

-

-

... More
iii) PVC cable 35mm sq.

0.75

-

-

... More
iv) PVC cable 70mm sq.

1.5

-

-

... More
v) PVC cable 120mm sq.

0.25

-

-

... More
vi) PVC cable 185mm sq.

0.35

-

-

... More
Supply & Connection of Bimetallic lugs:- a) 70sqmm

340

-

-

... More
b)95 sqmm

63

-

-

... More
c) 120 sqmm

63

-

-

... More
Supply of single circuit rewireable Porcelain Kit-Kat fuse unit of 500V grade as per relevant IS specification: i) 300 Amps.

21

-

-

... More
ii ) 200 Amps.

21

-

-

... More
iii ) 100 Amps

72

-

-

... More
Supply of 8 SW. G.!. wire as per ISS : 280/1978 amended latest with heavy coating as per ISS : 4826 I 1968 of tensile strength 55 to 95 Kgf /mm i/c fastening with cross arm & metallic parts for earth continuity wire and metal parts to earth electrode as per the direction of Engineer-in-charge.

1.2

-

-

... More
Supply of machine made nuts & bolts (Assorted Size):- a) 16X50mm N/B

0.15

-

-

... More
b)16X50mm N/B

0.15

-

-

... More
c) 16x90mm N/B

0.15

-

-

... More
d) 12X250mm N/B

0.4

-

-

... More
e) 12X300 mm N/B

0.25

-

-

... More
ERECTION

-

-

-

... More
Construction of 11 KV OH link line on NH-8A from 00 KM to 8.35 km

-

-

-

... More
Detailed Survey of route alignment with covering of existing Distribution Sub-Station, submission of route alignment, profile and final survey with profile in details indicating road crossing, river, water body, SCADA OFC cable, Water supply pipe line, Gas pipe line and P&T line etc:- i) Survey of route alignment for HT , LT Lines and DTs

8.35

-

-

... More
( a ) Erection of 12.0 mtr. long Steel Tubular Poles (Designation 410: SP-60) conforming to ISS: 2713 (P-I & II)-1980 with base plate direct in earth including excavation, refilling and ramming etc. as required (1/6th length of the pole to be embedded in earth) and grouting with CC of ratio 1:2:4 (1 cement : 2 river sand : 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required (@ 0.273 Cum per Steel Tubular Pole as per TSECL specification ) etc. and applying paints with ready mixed primer (two or more coats) and alluminium paint of approved quality to give an even shade etc. as required as per direction of Eng-In-Charge.

97

-

-

... More
( a ) Erection of 8.0 mtr. long PCC pole conforming to relevant ISS specification direct in earth including excavation, refilling and ramming etc. as required complete. 1/6 th of the length of the pole to be embedded in earth.

70

-

-

... More
( a ) Supply & erection of 9.0 mtr. long PCC pole conforming to relevant ISS specification direct in earth including excavation, refilling and ramming etc. as required complete. 1/6 th of the length of the pole to be embedded in earth.

46

-

-

... More
Erection of painted Stay Set complete( HT/LT) direct in earth with 16 mm. dia. 1.8 mtr. long painted stay rod, anchor plate of size 300 X 300 X 8 mm. thick, turn buckle of length 356 mm. with 300 mm. long threaded adjustable 16 mm. dia. MS rod , thimble, guy insulator as per IS specification, hot dip (heavy duty) galvanized stay stranded wire of size 7/2.5 mm. fastened with stay clamps as required. ( including supply of MS clamp & Nuts & Bolts as reqd) and Grouting of stay set with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required ( @ 0.119 Cum per stay set as per TSECL specification).

137

-

-

... More
Erection of 11 KV marked Danger Plate including supply on existing single/double Pole structure at a height of 4 mtr from the GL.

90

-

-

... More
Erection of 440V marked Danger Plate including supply on existing single/double Pole structure at a height of 4 mtr from the GL.

70

-

-

... More
Erection of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air brake switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of clamps, nuts and bolts as required.

19

-

-

... More
Erection of triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit foroperation in 11 KV, 50 Hz, AC system as per relevant IS specification along with Supply of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR.

19

-

-

... More
Erection of 9 KV, 5 KN single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Creepage distance 600 mm. conforming to ISS:3070/1985.

32

-

-

... More
( a ) Erection, Testing & commissioning of 3- Phase, 50 Hz, AC, Distribution Transformer as per attached technical specification,on Pole Mounted structure with necessary connections by ACSR from 11 KV line to Transformer via GOS & DOF:- i) 25 KVA ; 11/0.433 KV

15

-

-

... More
ii) 63 KVA ; 11/0.433 KV

15

-

-

... More
iii) 100 KVA; 11/0.433KV

14

-

-

... More
iv) 200 KVA; 11/0.433KV

3

-

-

... More
Erection Assorted size MS Channel/Angle100X50X50X6mm, 75 X 40 X 40 X 6 mm., MS channel 65 X 65 X 6 mm. , 50X50X6mm etc. arm on steel tubular pole or PCC pole or RS joist with 1 (one) no. or 2(two) nos. clamp of 50x6 mm. MS flat, nuts and bolts as required including painting with ready mixed primer of approved quality (two or more coats) and alluminium paint of approved quality on new works to give an even shade for cross-arm. as per direction of Eng-In-Charge. ( including supply of MS clamp & Nuts & bolts as reqd) a.)MS Channel (100X50X50X6 mm)

64

-

-

... More
c.) MS channel (75 X40X40X6mm )

64

-

-

... More
e.) MS Angle (65X65X6mm )

95

-

-

... More
p.)MS angle (50X50X6 mm)

124

-

-

... More
Erection of G.I. Straps and Bolts, 185 mm x 30 mm x 3 mm including Supply of Nuts & Bolts etc. as required with shackle insulator

1125

-

-

... More
( a ) Erection as per attached Technical Specification ,Laying, hoisting & stringing of ACSR Conductor including binding, jumpering, etc. as reqd. & as per direction of Engineer-in-charge. i) 6/1/2.59 sqmm dia ACSR, Rabbit conductor.

224.46

-

-

... More
Erection, laying & stringing of 8 G.!. wire as per ISS : 280/1978 amended latest with heavy coating as per ISS : 4826 I 1968 of tensile strength 55 to 95 Kgf /mm i/c fastening with cross arm & metallic parts for earth continuity wire and metal parts to earth electrode as per the direction of Engineer-in-charge.

72.33

-

-

... More
Erection of porcelain pin insulator for 11 KV system with mechanical strength 10 KN conforming to ISS:731/1971 on hot dip galvanized M.S forged 11 KV G.I pin complete with galvanized hexagonal nuts, G.I flat washer & G.I spring washer conforming to ISS: 2486(P-II)/1974.

2970

-

-

... More
Erection of porcelain disc insulator ball and socket type for 11 KV system (EMS-45 KN) conforming to ISS:731/1971 in angle and dead end locations including tension fittings of EMS-45 KN to accommodate the relevant ACSR conductor size along with supply of nuts and bolts, washer etc. as requied in complete & as per direction of Engineer-in-charge.

3537

-

-

... More
Providing of Sub-Station protective fencing of size 2X3 mtr and height 1.5 mtr as per Engineering requirement by 10 Nos MS angle post (50X50X6 mm) of height 2 mtr, horizontal bar 2X3 mtr and 2X2 mtr of MS angle (35X35X5mm) at top of angle posts and two part MS grill door of size 1.2/1.4 mtr with locking arrangement including necessary grouting and painted by Al paint over red oxide priming of approved quality as required as per T S including supply of all materials.

14

-

-

... More
Erection of anti-climbing devices viz barbed wires on pole structures including supply of barbed wres in helical form 7.5 cm. apart starting from ground level (1.5 Kg. / pole) as per direction of Engineer-in-charge.

350

-

-

... More
Erection of Porcelain Shackle Insulator (90X75mm) or ( 115X100 mm) for LT system with mechanical strength of 5 KN conforming to ISS:731/1971 with hot dip galvanized M.S G.I Straps with bolts in complete (suitable for Rabbit/DOG conductor) as per direction of Eng-In-Charge.

165

-

-

... More
Erection of wooden plank (preferably karai wood) of size 24" X 10" X 1.5" for fixing of cut outs with supply of 2(two) nos. M.S. clamps of 50x6 mm MS flat Nuts & bolts as required to be erected on the steel tubular, pee pole as per direction of Engineer-in-charge.

14

-

-

... More
Providing and Erection of HT Protective cradle guard made of 8 SWG G.I. wire as per ISS : 280/1978 with latest amendment if any, heavy coating as per ISS : 4826 I/ 1968 of tensile strenath 55 to 95 kgf/sq.mm i/c suuply of 8 S.W.G. G.I Wire as required as per direction of Engineer-in-Charge.

2000

-

-

... More
Grouting of steel tubular poles with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shutterirtg as required.(@ 0.33 Cum per steel tubular pole as per TSECL specification ).

70

-

-

... More
Grouting of stay set with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shutterirtg as required.( @ 0.119 Cum per stay set as per TSECL specification)

32.3

-

-

... More
Erection of earthing set as per ISS : 3043 of 1966 and with upto date mendment having 2.5 mtr long G.I. pipe (IS I marked) of 40 mm diameter with holes Including a pair of clamps of 50 X 6 mm M.S. flat & 12 mm dia galvanized nuts & bolts long with alternate layers of salt & charcoal including supply of 8 SWG GI wire for earth connectivity as required.

126

-

-

... More
Applying priming coat with ready mixed primer of approved quality om steel pole and steel work including painting ( two or more coats) with alluminium paint of approved quality on new work to give an even shade ( TSR - 2013 )

300

-

-

... More
( a ) Making connection from Transformer LT side to overhead LT Line via fuse unit of unarmoured PVC cable 1100-V grade conforming to ISS: 1554 (P-I) /1988 of the following sizes and the cables shall be properly crimped by bimetallic lugs at contact areas as per direction of Engineer-in-charge:- i) PVC cable 4mm sq.

2

-

-

... More
ii) PVC cable 16mm sq.

0.25

-

-

... More
iii) PVC cable 35mm sq.

0.75

-

-

... More
iv) PVC cable 70mm sq.

1.5

-

-

... More
v) PVC cable 120mm sq.

0.25

-

-

... More
vi) PVC cable 185mm sq.

0.35

-

-

... More
Supply & Connection of Bimetallic lugs.:- a) 70sqmm

123

-

-

... More
b)95 sqmm

339

-

-

... More
c) 120 sqmm

101

-

-

... More
Erection, laying & stringing of 8 SW. G.!. wire as per ISS : 280/1978 amended latest with heavy coating as per ISS : 4826 I 1968 of tensile strength 55 to 95 Kgf /mm i/c fastening with cross arm & metallic parts for earth continuity wire and metal parts to earth electrode as per the direction of Engineer-in-charge.

12

-

-

... More
Erection of machine made nuts & bolts (Assorted Size):- a) 16X50mm N/B

0.15

-

-

... More
b)16X50mm N/B

0.15

-

-

... More
c) 16x90mm N/B

0.15

-

-

... More
d) 12X250mm N/B

0.4

-

-

... More
e) 12X300 mm N/B

0.25

-

-

... More
Cutting, clearing and disposal of jungle/ tree of any girth from either side of HT/LT line for providing required vertical and horizontal clearance as per provision of I.E. Rule

8

-

-

... More
Construction of RCC Transformer Base for three nos 315/100 KVA Transformer:- Earth work in excavation in foundation trenches not exceeding 1.5m in width or 10sqm on plan or drains 1.5m in width or 10sqm on plan i/c dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal a) All kinds of soil: Excluding rock

26.94

-

-

... More
Filling available excavated earth excluding rock) in trenches, plinth, sides of foundation etc. in layer not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.50m.

15.39

-

-

... More
Filling in plinth with sand under floor i/c watering ramming consolidating and dressing complete.

1.32

-

-

... More
Providing and laying in foundations and plinth cement concrete 1:5:10(1 cement:5 river sand: 10 jhama brick aggregate 40mm nominal size) excluding the cost of centering and shuttering.

2.24

-

-

... More
Cement Concrete work 1:2:4(1 cement:2 river sand:4 Jhama brick aggt. 20mm nominal gauge) excluding the cost of centering, shuttering in:

118.31

-

-

... More
Providing and fixing hard drawn steel wire fabric 75 x 25 mm mesh of weight not less than 4.80 kg per sqm to out side fencing filled with M.S. angle or flat frame by electric welding as per direction of the Engineer-in-charge. ( frame work to be paid separately) a)12 mm cement plaster 1:6 (1 cement : 6 river sand).

15.3

-

-

... More
Applying priming coat with ready mixed genuine red lead paint of approved quality on steel work.

46.32

-

-

... More
Painting two or more coats (excluding priming coat ) with superior ready mixed paint for steel work of approved quality in all shades on new work to give an even shade.

46.32

-

-

... More
DISMANTLING OF THE FOLLOWING ITEMS. Dismantling of 18" short bracket

15

-

-

... More
Dismantling of G.I wire (8 SWG)

6.2

-

-

... More
Dismantling of 2 Wire LT bracket in/c clamp, nut&bolts etc.

19

-

-

... More
Dismantling of 4/5 Wire LT bracket in/c clamp, nut&bolts etc.

12

-

-

... More
Dismantling of C bracket. 2/3 Wire in/c clamp, nut&bolts etc.

25

-

-

... More
Dismantling of C. bracket.4/5-Wire in/c clamp, nut&bolts etc.

23

-

-

... More
Dismantling of 11KV V-Cross arm in/c clamp, nut&bolts etc.

26

-

-

... More
Dismantling of 11KV S.P. Top Cross arm in/c clamp, nut&bolts etc.

26

-

-

... More
Dismantling of 11KV S.P Bottom Cross arm in/c clamp, nut&bolts etc.

65

-

-

... More
Dismantling of 11 KV S.P. Guard Cross arm in/c clamp, nut&bolts etc.

65

-

-

... More
Dismantling of 11 KV D.P. top Cross arm in/c clamp, nut&bolts etc.

32

-

-

... More
Dismantling of 11KV D.P. Bottom Cross arm in/c clamp, nut&bolts etc.

32

-

-

... More
Dismantling of 11 KV D.P. Guard Cross arm in/c clamp, nut&bolts etc.

32

-

-

... More
Dismantling of Stay set complete (HT/LT) in/c earth excavation.in/c clamp, nut&bolts etc.

48

-

-

... More
Dismantling of 2.4 to 2.8 mtr long MS angle /channel of sub-station cross arm in/c clamp, nut&bolts etc.

14

-

-

... More
Dismantling of 0.3 to 2.3 mtr long MS angle /channel of sub-station cross arm in/c clamp, nut&bolts etc.

24

-

-

... More
Dismantling of 10 to 63 KVA Transformer from base(Pole mounted/RCC base)

9

-

-

... More
Dismantling of 100 KVA Transformer from base(Pole mounted/RCC base)

2

-

-

... More
Dismantling of 200 KVA Transformer from base(Pole mounted/RCC base)

2

-

-

... More
Dismantling of 7.5 mtr. long PCC Pole in/c earth excavation.

27

-

-

... More
Dismantling of 8 mtr. long PCC Pole in/c earth excavation.

32

-

-

... More
Dismantling of 9.5/9 mtr. long PCC Pole in/c earth excavation.

53

-

-

... More
Dismantling of broken PCC Pole

6

-

-

... More
Dismantling of 8/9 mtr. long Steel Tubular Pole in/c earth excavation.

6

-

-

... More
Dismantling of 10/12 mtr. long Steel Tubular Pole in/c earth excavation.

22

-

-

... More
Dismantling of broken Steel Pole

2

-

-

... More
Dismantling of LT Shackle Insulator i/c or ex/c. straps, Nuts & Bolts.

73

-

-

... More
Dismantling of 11KV Disc. Insulator with fittings.

123

-

-

... More
Dismantling of 11 KV Pin Insulator with G.I Pin.

210

-

-

... More
Dismantling of ACSR (6/1/2.59 or equivalent AASC or higher size)in/c oppening of jumpering,binding, cioling stacking etc. as per diredtion of the Eng. In Charge.

32.3

-

-

... More
Dismantalling of Triple pole ( 3ph, 12 KV), 200 Amps manually gang operated air break switch (A.B.Switch.) including necessary connection.

3

-

-

... More
DISMANTLE of Triple pole (3 ph, 12 KV)200 Amp drop out fuse unit(D.O.Fuse Unit) suitable for operation for 11 KV, 50 Hz AC system including necessary connection.

3

-

-

... More
Dismantalling of Triple pole ( 3ph, 12 KV), 200 Amps manually gang operated air break switch (A.B.Switch.) including necessary connection.

3

-

-

... More
DISMANTLE of Triple pole (3 ph, 12 KV)200 Amp drop out fuse unit(D.O.Fuse Unit) suitable for operation for 11 KV, 50 Hz AC system including necessary connection.

3

-

-

... More
Dismantleling of 11 KV L.A (Conventional gapped type)

9

-

-

... More
Dismantaling & Refixing of 1-Ph S/C

49

-

-

... More
Dismantaling & Refixing of 3-Ph S/C

8

-

-

... More
Carriage of Pole from Work site to work site within 12.00 km by Mechanical Transport, Handcart, Manual labour, etc as required including loading/unloading & stacking etc. as per direction of the Egn.-In - Charge:- ( I ) 7.5 mtr.long PCC Pole

27

-

-

... More
( ii ) 8.0 mtr.long PCC Pole

40

-

-

... More
( iii ) 9.0 mtr.long PCC Pole

32

-

-

... More
( iv ) 9.0 mtr.long Steel Tubuler Pole

26

-

-

... More
( v )11.0 mtr.long Steel Tubuler Pole

12

-

-

... More
Carriage of dismantles line materials from worksite to work site above 12.00 km by Mechanical Transport, Handcart, Manual labour, etc as required including loading/unloading & stacking etc. as per direction of the Egn.-In - Charge.

12

-

-

... More
Carriage of Dismantes Transformer from Worksite to work site within 12.00 km by Mechanical Transport, Handcart, Manual labour, etc as required including loading/unloading & stacking etc. as per direction of the Egn.-In - Charge: i.) 10 to 63 KVA

10

-

-

... More
ii.)100 KVA

2

-

-

... More
iii)200 KVA

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.