BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Costs
EMD
₹ 70,215Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Extension Of Service Connection To 09 Nos Bsnl 4g Tower
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_POWER_48085_1Bid Award Id
ViewTender No
DGM/MANU/E-TENDER/23-24/07Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://tripuratenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Stay Insulator (HT) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
90
-
-
Stay Std. wire, (7/2.50 mm) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed.
450
-
-
M.S. Channel-100X50X50X6 mm, conforming to relevant IS with up-to- date amendment and as per TSECL’s tender specification enclosed .
918
-
-
M.S. Channel-75x40x40x6mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
1841
-
-
M.S. Angel 65x65x6mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
1244
-
-
M.S. Nuts & bolts (assorted size) conforming to relevant IS with up-to- date amendment and as per TSECL’s tender specification enclosed .
209
-
-
11 KV Pin Insulator (Poly) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
222
-
-
11 KV Disc Insulator (Poly) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
240
-
-
11 KV Disc Fittings conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
240
-
-
A.C.S.R-6/1/2.59 mm weasel conductor conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
20
-
-
G.I. wire-8 SWG conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
1176
-
-
11 KV G.O. Switch, 3-Phase conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
9
-
-
11 KV D.O. Fuse, 3-Phase conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
9
-
-
11 KV L.A. polymer(9 KV, 5 KA L.A) conforming to relevant IS with up-to date amendment and as per TSECL’s tender specification enclosed
27
-
-
100 A Cut-Out conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
27
-
-
200 A Cut-Out conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
27
-
-
PVC Cable-70 sq.mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
450
-
-
PVC Cable-16 sq.mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
1260
-
-
Danger plate conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
10
-
-
Barbed wire conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
162
-
-
60 kg Salt & 55 kg Charcoal for earthing (1 pit)
27
-
-
GI pipe 40mm dia 2.5 Mtr long (Make - TATA / JINDAL) conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed
27
-
-
Wooden plank
9
-
-
Aluminium Lugs - 95 sq.mm conforming to relevant IS with up-to-date amendment and as per TSECL’s tender specification enclosed .
108
-
-
PVC Pipe 1" Size
18
-
-
Stay Clamp of MS Flat (50x6mmm)
90
-
-
Bracket Clamp of MS Flat (50x6mmm)
378
-
-
Schedule- B Erection
-
-
-
Installation / positioning of 11/0.230 KV , 1-phase 16 KVA of distribution transformer on pole with necessary connection and fitting fixing of all allied assessories components as required for making complete in all respect for energizing .
9
-
-
9 mtrs length of PCC pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect
106
-
-
2.8 Mtr. Long MS Channel of Size 100x50x50x6mm for DT & Disc support
27
-
-
0.8 Mtr. Long MS Channel of Size 100x50x50x6mm for DT support
18
-
-
2.8 Mtr. Long MS Channel of Size 75 x50x 50x6 mm for GO & DO & LA i/c lineGO & DOF
45
-
-
2.8 Mtr. Long MS Channel of Size 65x65x6mm SS
9
-
-
SP Top X-arm of 0.3 Mtr. Long MS Channel of Size 75x40x40x6mm
26
-
-
SP bottom X-arm of 1.2 Mtr. Long MS Channel of Size 75x40x40x6mm
26
-
-
SP Guard X-arm of 1.6 Mtr. Long MS Angle of Size 65x65x6 mm.
26
-
-
DP Top X-arm of 1.7 Mtr. Long MS Channel of Size 75x40x40x6mm.
40
-
-
DP bottom X-arm of 2.2 Mtr. Long MS Channel of Size 75x40x40x6mm.
40
-
-
DP Guard X-arm of 2.5 Mtr. Long MS Angle of Size 65x65x6 mm.
40
-
-
Laying & stringing of 1 km (single conductor ) ACSR 6/1/2.59mm dia weasel i/c hoisting & binding etc. complete as reqd.
20
-
-
Laying & stringing of 1 km (single conductor ) 8 SWG GI wire i/c hoisting & binding etc. complete as reqd.
9.5
-
-
Stay Set Complete
90
-
-
11KV Polymer Disc insulator with fittings
240
-
-
11KV Polymetric Pin Insulator
222
-
-
11 KV G.O.S. 3-phase
9
-
-
11 KV D.O.F. 3-phase
9
-
-
11 KV L.A. (polymer)
27
-
-
Cradle Guard
264
-
-
Barbed wire (anti-climbing device) per pole
108
-
-
Danger plate
10
-
-
Providing Single phase Service Connection
9
-
-
Construction of Sub-station Fencing with barbed wire, errection supply & errection of barbed wire fencing of MS Angle ( 6Nos. 65x65x6mm & 4Nos . 50x50x6 mm)& provision of gate ( to be fabricated by 35x35x6 mm M.S. Angle-20x6mm M.S. Flat ) fixed with supports of fencing belted at top by 35x35x6 mm M.S. Anglethrough out with provision of hings & locking arragement etc. as per approved design & drawing .
9
-
-
Sub-Station Name plate in/c supply as directed by Engg- in -charge.
9
-
-
Earthing with GI pipe 2.5mtr long and 40 mm dia, including excavation, refilling with alternate layer of salt and charcoal as per drawing (excluding supply of GI pipe, salt and charcoal, GI wire, Nuts & bolts etc.
As required).
27
-
-
carring of the following
-
-
-
carriage of Distribution Transformer from AD Nagar agartala electrical store yard to work side by mechanical transport including loading Unloading & Stacking etc as required
-
-
-
16 KVA transformer
9
-
-
carriage of the Following from Manul store yard to work side by mechanical transport including loading Unloading & Stacking etc as required
-
-
-
9 Mtr Long PCC Pole
106
-
-
Fabrication of all X-Arm by M.S Angle, MS Channel , M.S. flats etc.
4003
-
-
Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager
9
-
-
Stratening of 9 Mtr Long PCC Pole
6
-
-
Re stringing of conductor including binding hoisting jumpering etc as required
-
-
-
A.C.S.R-(6/1/2.59 mm)
1
-
-
Re-adjustment of stayset complete without dismentalling turn buckle.
6
-
-
Jungle cutting
15
-
-