Tripura State Electricity Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Tripura State Electricity Corporation Limited - TSECL Tender
Electrical and Electronics
Eprocure
Opening Date5 Mar 2024
Closing Date11 Mar 2024
Tender Amount₹ 86,93,318
Costs
EMD
₹ 1,73,866Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_POWER_48163_1Bid Award Id
ViewTender No
DGM/ED-KCP/23-24/20Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://tripuratenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
25 kva Distribution Transformer
2
-
-
11.0 mtr long Galvonized Tubular pole
42
-
-
8.0 mtr long Galvonized Tubular pole
40
-
-
Stayset complete
60
-
-
Stay wire (7/2.5 mm dia.)
280
-
-
11KV Stay insulator
60
-
-
11kv Polimeric Disc insulator (45KN)
368
-
-
11 kv Disc fittings
168
-
-
11kv Polimeric Pin insulator
460
-
-
LT Shackle insulator
142
-
-
11kv G.O. Switch, 3 phase Polymer
11
-
-
11kv D.O. fuse, 3 phase Polymer
11
-
-
11KV L.A (9 KV, 5KA)
24
-
-
Galvonized channel (100x50x50x6mm)
700
-
-
Galvonized channel (75x50x50x6mm)
1442
-
-
Galvonized angle(65x65x6)
1670
-
-
Galvonized angle(50x50x6)
320
-
-
ACSR (3/1/2.59 mm dia.)
13
-
-
10swg GI wire
450
-
-
HT Danger plate
36
-
-
Barbed wire
40
-
-
Cut out 200 amps
36
-
-
PVC Cable 120 mm2
330
-
-
Bimetallic Lugs of size 95
72
-
-
Bimetallic Lugs of size 120
36
-
-
8'x12" Wooden Board for Meter & 16A Cut out
362
-
-
4'x6" Wooden Board for with 3 board switch & 1 pin Point
362
-
-
3'x3" Wooden Board with 2 Angle Holder
724
-
-
Wooden Batton (20X8X0.5 inch per each)
362
-
-
Main Switch ISI Mark
362
-
-
2.5 sq mm PVC cable 2-core alluminium for service connection.
25340
-
-
2.5 sq mm PVC wire 1-core alluminium for internal wiring (6X2=12mtr each)
4344
-
-
GI 10mm for Service connection
2172
-
-
Real Insularor
4344
-
-
Fabricated GI Clamp Made of 50x6mm for (11kv Line 140Nos + S/S 120 Nos + 80nos LT line)
340
-
-
Fabricated GI Clamp Made of 50x6mm for LT line.
142
-
-
Fabricated GI Clamp Made of 50x6mm for Stay set
120
-
-
Fabricated GI Clamp Made of 50x6mm for DP Cross connection arm
76
-
-
Galvanized Nuts & Bolts i/c washer of assorted size
680
-
-
16A cutout
362
-
-
2 Balb & 2 Holder
362
-
-
Supply of 60 kg Salt & 55 kg Charcoal (1 pit)
20
-
-
2.5 mtr long, 40 mm dia G.I pipe (TATA/ JINDAL make)
20
-
-
Wooden plank
10
-
-
Dismentalling of the following line materials
-
-
-
63 KVA Distribution Transformer (damage)
2
-
-
25 KVA Distribution Transformer (damage)
4
-
-
Providing Single phase Service Connection
110
-
-
A.C.S.R. (6/1/2.59 mm)
14
-
-
GI Wire (10SWG)
6
-
-
Cradle guard
220
-
-
11KV Disc insulator with fittings
342
-
-
11KV Pin Insulator with GI pin
368
-
-
LT Shackle insulator
280
-
-
Stay Set Complete
34
-
-
11 KV G.O.S. 3-phase (Damage)
5
-
-
11 KV D.O.F. 3-phase (Damage)
5
-
-
11 KV L.A. Set (Damage)
15
-
-
3.2 Mtr. Long Galvonized Angle of Size 65x65x6mm for DP cross connection arm
52
-
-
2.2 Mtr. Long Galvonized Angle of Size 65x65x6mm for DP cross connection arm
52
-
-
SP Top X-arm of 0.3 Mtr. Long Galvonized Channel of Size 75x40x40x6mm
29
-
-
SP bottom X-arm of 1.2 Mtr. Long Galvonized Channel of Size 75x40x40x6mm
29
-
-
SP Guard X-arm of 1.5 Mtr. Long Galvonized Angle of Size 65x65x6 mm.
29
-
-
DP Top X-arm of 2.2 Mtr. Long Galvonized Channel of Size 75x40x40x6mm.
26
-
-
DP Top Guard X-arm of 2.5 Mtr. Long GalvonizedChannel of Size 65x65x6 mm.
26
-
-
LT 5-wire C Bracket
45
-
-
Uprooting of 9.00 Mtr long Steel pole (D.P.)
26
-
-
Uprooting of 9.00 Mtr long Steel pole (S.P.)
29
-
-
Uprooting of 8.00 Mtr long Steel pole (LT line.)
39
-
-
Erection of the following line materials
-
-
-
11.00 Mtr. Long Galvonized tubuler Pole
42
-
-
9.00 Mtr. Long Galvonized tubuler Pole
95
-
-
8.00 Mtr. Long Galvonized tubuler Pole
79
-
-
3.2 Mtr. Long Galvonized Angle of Size 65x65x6mm for DP cross connection arm
70
-
-
2.2 Mtr. Long Galvonized Angle of Size 65x65x6mm for DP cross connection arm
70
-
-
2.8 Mtr. Long Galvonized Channel of Size 100x50x50x6mm for DT support
21
-
-
0.6 Mtr. Long Galvonized Channel of Size 100x50x50x6mm for DT support
14
-
-
2.8 Mtr. Long Galvonized Channel of Size 75x50x50x6mm for GO, DO, LA & GO pipe
40
-
-
SP Top X-arm of 0.3 Mtr. Long Galvonized Channel of Size 75x40x40x6mm
47
-
-
SP bottom X-arm of 1.2 Mtr. Long Galvonized Channel of Size 75x40x40x6mm
47
-
-
SP Guard X-arm of 1.5 Mtr. Long Galvonized Angle of Size 65x65x6 mm.
47
-
-
DP Top X-arm of 2.2 Mtr. Long Galvonized Channel of Size 75x40x40x6mm.
44
-
-
DP Top Guard X-arm of 2.5 Mtr. Long Galvonized Channel of Size 65x65x6 mm.
44
-
-
2.5 Mtr. Long Galvonized Channel of Size 75x50x50x6mm for line GO, DO & GO pipe.
15
-
-
LT 5-wire C Bracket
82
-
-
11KV polymeric disc insulator with fittings
462
-
-
11KV Polymetric Pin Insulator
488
-
-
LT Shackle insulator
350
-
-
Stay Set Complete
94
-
-
A.C.S.R. (6/1/2.59 mm)
28
-
-
GI Wire (10SWG)
15
-
-
11 KV G.O.S. 3-phase
11
-
-
11 KV D.O.F. 3-phase
11
-
-
11 KV L.A. Set
27
-
-
Cradle Guard (HT)
440
-
-
Danger plate
20
-
-
Erection of barbed wire per pole
82
-
-
100 KVA Distribution Transformer
1
-
-
63 KVA Distribution Transformer
5
-
-
25 KVA Distribution Transformer
2
-
-
Re-erection Single phase Service Connection with GI wire Reel insulator etc as required
110
-
-
Providing Single phase Service Connection with fitting fixing of board, main switch, switch point cutout holder etc as required
362
-
-
Construction of Sub-station Fencing with barbed wire, errection supply & errection of barbed wire fencing of MS Angle ( 6Nos. 65x65x6mm & 4Nos . 50x50x6 mm)& provision of gate ( to be fabricated by 35x35x6 mm M.S. Angle-20x6mm M.S. Flat ) fixed with supports of fencing belted at top by 35x35x6 mm M.S. Anglethrough out with provision of hings & locking arragement etc. as per approved design & drawing of ED-KCP .
8
-
-
Earthing with GI pipe 2.5mtr long and 40 mm dia, including excavation, refilling with alternate layer of salt and charcoal as per drawing (excluding supply of GI pipe, salt and charcoal, GI wire, Nuts & bolts etc. As required).
24
-
-
Grouting of Steel Tubular Poles with CC work ratio 1:2:4 (1 Cement :2 River Sand :4 Jhama Brick agreegate of 20 mm normal size ) including supply of Cement, Sand & brick aggregate complete with excavation , refilling of earth , ramming along with centering & shuttering as reqd. (0.275 Cum / Steel Tubular Pole)
22.55
-
-
HIRING OF VEHICLE
-
-
-
Carriage of 11.00 mtr. Length of Gelvonized Steel Pole by mechanical transport from Dasda Electrical Sub-Divisional sitestore to work site vis-a-vis including loading, unloading & stacking as required.
-
-
-
a)Beyond 25 km upto lead of 50 km
-
-
-
ii) Beyond 4 poles
42
-
-
Carriage of 8.0 / 9.0 mtr. Length of Gelvonized Steel Pole by mechanical transport from Dasda Electrical Sub-Divisional sitestore to work site vis-a-vis including loading, unloading & stacking as required. (HT-14nos + LT-35nos)
-
-
-
a)Beyond 25 km upto lead of 50 km
-
-
-
ii) Beyond 4 poles
52
-
-
Carriage of 1(one)no- 100 KVA transformer from Dasda Electrical Storeyard to work site by mechanical transport including Loading, Un-loading & Stacking etc. as required. .
-
-
-
a)Beyond 25 km upto lead of 50 km
1
-
-
Carriage of 1(one)no- 63 KVA transformer from Dasda Electrical Storeyard to work site by mechanical transport including Loading, Un-loading & Stacking etc. as required and back Damage DT
-
-
-
a) Upto lead 25 km
5
-
-
Carriage of 1(one)no- 25 KVA transformer from SK Shermun to Dasda Electrical Storeyard by mechanical transport including Loading, Un-loading & Stacking etc. as required and back Damage DT
-
-
-
a) Upto lead 25 km
2
-
-
Carriage of line materials such as Cable, AAC, AAAC, ACSR, GI wire, Cross arm, stay set, insulators etc by mechanical transport from the electrical Sub-Divisional sitestore to working site including loading, unloading & stacking as required.
-
-
-
a)Beyond 25 km upto lead of 50 km
20
-
-
Carriage of materials such as G.O.S, D.O.F, LA etc by mechanical transport from the electrical Sub-Divisional sitestore to working site including loading, unloading & stacking as required.
-
-
-
a)Beyond 25 km upto lead of 50 km
2.2
-
-
Manual carriage of 11.00 mtr. Length of Steel tubuler Pole approx. 7km Each pole from Gobindabari to work side
42
-
-
Manual carriage of 9.0/8.00 mtr. Length of Steel tubuler Pole approx. 7km Each pole from Gobindabari to work side .(9.0 mtr=12nos + 8.0mtr. = 40nos)
52
-
-
Manual carriage of line materials approx. 7km such as GOS, DOS, Cable, AAC, AAAC, ACSR, GI wire, Cross arm, stay set, insulators etc from Gobindabari to work side.
6
-
-
Fabrication & Gungle cutting
-
-
-
Fabrication of all X-Arm by Galvonized Angle/Channel etc.
5169
-
-
Jungle cutting
19
-
-
Fitting, fixing of Sub-station cable jointing & cutout.