Tripura State Electricity Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Costs
EMD
₹ 2,52,365Document Cost
₹ 8,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_POWER_47871_1Bid Award Id
ViewTender No
DGM/ED/KLS/2023-24/06Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://tripuratenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Stay set [ LT ]
78
-
-
Stay insulator (HT)
194
-
-
Stay insulator (LT)
78
-
-
GI Stay wire 7/4 mm (272X5)
1360
-
-
M.S. Ch. 100 x 50 x 50 x 6 mm [2.8X18+0.8X12=60.00x9.56=573.60-Kg
573.6
-
-
M.S. Ch. 75 x 40 x 40 x 6 mm[2.8x96+0.3x130+1.2x130+1.7x71+2.2x71]= 740.70x7.14=5288.60-kg
5288.6
-
-
M.S.Angle 65 x 65 x 6 mm. [2.8X48+1.6x130+2.5x71]=519.90x5.8=3015.42-kg
3015.42
-
-
11 KV Polymeric Disc insulator [45 KN]
498
-
-
11 KV Polymeric Disc fittings.
498
-
-
11 KV Polymeric composite Pin insulator
639
-
-
11 KV G.I Pin.
639
-
-
ACSR WEASEL (30 Sq.mm) Conductor
44.6
-
-
GI wire (8 SWG)
2974
-
-
LA - 9 KV 5 KA (set of 3 no)
18
-
-
11 KV GOS (3 phase Porcelin type)
12
-
-
11 KV DOF (3 phase Porceilin type)
6
-
-
25 - KVA Distribution Transformer,11/0.433-KV (Al) [BIS Level-II]
6
-
-
Cut Out [100 A]
18
-
-
Danger plate
250
-
-
PVC Cable 70-sqmm
180
-
-
Barbed wire
452
-
-
60-Kg Salt & 55-Kg Charcoal for earthing (1-Pit)
48
-
-
2.5-mt long 40-mm dia G.I.Pipe (TATA/JINDAL)
48
-
-
Wooden plank (Gamai/Karai)
6
-
-
Bi-Mettalic Lugs-70-sq.mm
108
-
-
PVC Pipe 1" size
24
-
-
L.T.AB Cable (3x70+1x50+1x65)-sq.mm
6.9
-
-
Suspension clamp Assembly with straps & buckle
180
-
-
Dead end clamp Assembly with straps & buckle
180
-
-
Service Anchor clamp
180
-
-
Distrbution Box 1-Phase ( 25 mm / 50 mm)
95
-
-
Cable End Cap (25-35 mm / 25-50 mm)
180
-
-
Cable Ties
180
-
-
Eye Hook
180
-
-
Pole clamp
180
-
-
Insulator piercing connector Main (16-95 sq.mm) & Tap 4-35(50) sq.mm
180
-
-
Stay clamp of MS Flat (50x6-mm)
544
-
-
Bracket clamp of MS Flat (50x6-mm)
1398
-
-
Nuts & Bolts (assorted) size
776.8
-
-
2.5-Sq.mm PVC Cable (35x2x128)
8960
-
-
Re-wireable Porcelin Cut out 16 Amp
128
-
-
10-SWG GI Wire for holding Service cable (3-Kg x 128)
384
-
-
Reel insulator (15x128)
1920
-
-
8-SWG GI Wire for coil Earthing (4x128)
512
-
-
16-Amp ICDP Main Switch with ISI mark
128
-
-
Wooden plank (thickness 1")
128
-
-
9W LED Bulb
128
-
-
Angle holder ISI mark
128
-
-
4x4" Wooden / polycarbonate Board
128
-
-
5 Amp piano switch ISI mark
128
-
-
Single core 1.5-sq.mm Copper wire
384
-
-
Supply & Erection of Screw of assorted size
2560
-
-
carrying of following from AD Nagar store to work site:- (a) S.T Pole 9.00mtr long(Upto 8 nos pole)
8
-
-
carrying of following from AD Nagar store to work site:- (b) S.T Pole 9.00mtr long (beyond 8 nos pole)
276
-
-
ERECTION OF THE FOLLOWING:- Erection of 9-mt length of S.T. Pole at any kind of soil upto a depth of 1/6 th of pole height including excavation of earth refilling the pit with soil upto the ground ;level ramming & making complete in all respect
284
-
-
Erection of 8-mt length of S.T. Pole at any kind of soil upto a depth of 1/6 th of pole height including excavation of earth refilling the pit with soil upto the ground ;level ramming & making complete in all respect
168
-
-
Erection of Stay set direct in earth complete with 19mm x 1800mm long stay rod,anchor plate of size 300x300x8-mm thimble,turn buckle,7/3.15 mm dia G.I.Stranded stay wire & stain sulator etc. with supply of M.S.Clamp, Nuts & bolts etc as reqd and making complete in all respect
272
-
-
Erection of M.S.Channel Cross-Arm 2.8-mtr long 100x50x50x6 mm (Excluding the cost of Back clamp, Nuts & Bolts)
18
-
-
Erection of M.S.Channel Cross-Arm 0.8 -mtr long 100x50x50x6 mm (Excluding the cost of Back clamp, Nuts & Bolts)
12
-
-
Erection of M.S.Channel Cross-Arm 2.8-mtr long 75x40x40x6 mm for GO,DO & LA (Excluding the cost of Back clamp, Nuts & Bolts)
96
-
-
Erection of M.S.Angle Cross-Arm 2.8-mtr long 65x65x6 mm (Excluding the cost of Back clamp, Nuts & Bolts)
48
-
-
Erection of M.S.Channel Cross-Arm 0.3 mtr long 75x40x40x6 mm for S.P.Top bracket (Excluding the cost of Back clamp, Nuts & Bolts)
130
-
-
Erection of M.S.Channel Cross-Arm 1.2 mtr long 75x40x40x6 mm for S.P Bottom bracket (Excluding the cost of Back clamp, Nuts & Bolts)
130
-
-
Erection of M.S.Angle Cross-Arm 1.6-mtr long 65x65x6 mm for S.P.Guard (Excluding the cost of Back clamp, Nuts & Bolts)
130
-
-
Erection of M.S.Channel Cross-Arm 1.7 mtr long 75x40x40x6 mm for D.P.Top bracket (Excluding the cost of Back clamp, Nuts & Bolts)
71
-
-
Erection of M.S.Channel Cross-Arm 2.2 mtr long 75x40x40x6 mm for D.P Bottom bracket (Excluding the cost of Back clamp, Nuts & Bolts)
71
-
-
Erection of M.S.Angle Cross-Arm 2.5-mtr long 65x65x6 mm for D.P.Guard (Excluding the cost of Back clamp, Nuts & Bolts)
71
-
-
Erection of 11 KV single Disc insulator set along with necessary fitting
498
-
-
Erection of 11 KV Pin insulator along with Pin
639
-
-
Erection of Danger plate on OH lines (11-KV/415Volts)
250
-
-
Laying & stringing of 1KM (Single conductor) ACSR 6/1/2.59 mm dia WEASEL including hoisting & binding etc complete as reqd.
44.6
-
-
Laying & stringing of 1KM (Single conductor) G.I.Wire 8-SWG including hoisting & binding etc complete as reqd.
29.74
-
-
Erection of 9 KV, 5 KA Single pole metal oxide gapless type LA including necessary connection complete as per technical specification
18
-
-
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification (Excluding the cost of back clamp, Nuts & bolts)
12
-
-
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification (Excluding the cost of back clamp, Nuts & bolts)
6
-
-
Laying of 8-SWG GI Wire at 300-mm below the ground level for earthing of Sub-station equipments from the earth electrode/ HT Pole/ LT Pole/ service main
306
-
-
Installation/positioning of 11/0.433 KV 3-Phase 25- KVA of distribution Transformer on pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing
6
-
-
Erection of 11 KV protective guarding by GI wire 8 SWG as per technical specification across road/river/Telecom line etc in horizontal formation complete
1356
-
-
Supply & erection of substation fencing with erection of 6nos 2.50m long ( 65 x 65 x 6mm) Angle post and 4nos( 50 x 50 x 6mm)angle post with grouting of vol 0.045cum at the ratio of 1:2:4(1cement :2R. sand : 4 jhamabrick aggregate) per post. The fencing should be made 9 horizontal line of barbed wire and one gate with shutter (2 x 1.7)m i/c locking arrangement etc complete as per diection of the Engg. in charge.
6
-
-
Fabrication of X-arm by MS Angle/MS Channel as per specification
8877.62
-
-
Earthing with G.I.Pipe 2.5 mtr long & 40 mm dia including excvation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, GI Wire, Nuts & bolts etc as required)
24
-
-
Barbed wire (anti-climbing device)
452
-
-
Positioning of cable drum, removing of cable from drum & laying,hoisting & drawing of AB Cable 3x70-95+1x16-25+1x50-95-sq.mm of 101 KV grade as per direction of E-I-C
6900
-
-
Fitting-fixing of Service main 1/3-phase distribution Box 1.01-KV grade on PCC/ST Pole with help of pole brackets or steel straps & buckle as per direction of E-I-C
95
-
-
Erection & ditting-fixing of insulated suspension clamp including pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/ST Pole with the help of pole brackets or steel straps & buckle as per direction of E-I-C
180
-
-
Erection & ditting-fixing of insulated Dead end / Anchor clamp including pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/ST Pole with the help of pole brackets or steel straps & buckle as per direction of E-I-C
180
-
-
Erection & ditting-fixing of insulation of Piercing connector (IPC) of all sizes of 1.1 KV grade including connection from main cable to Distribution Box, Tee-off line as per direction of E-I-C
180
-
-
Providing Single Phase Service Connection with laying PVC cable from nearby Electrical pole to premises up to 35 mtr in length supported by G.I.Wire Reel insulator i/c fitting, fixing of Energy Meter as reqd.
128
-
-
Carriage of 11/0.433 KV 3 Phase 25 KVA by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
6
-
-
Carriage of 8/9-mtr long S.T. pole by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
452
-
-
Carriage of steel materials,ACSR,GI Wire,GOS & DOF LA etc by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
20
-
-
Grouting of 9-Mtr long S.T. Pole (1-Cement : 2-coarse river : 4-graded stone) = .273-cum/Pole
123.4
-
-
Sub-station Name plate in/c supply as directed by Engg-in-charge
6
-
-
Maintaining adequate clearence from overhead live conductors by Trimming of tree branches for way leaves
18
-
-
Straightening of 9-mt long PCC Pole
42
-
-
Re-adjustment of Stayset complete without dismentalling of turn buckle
25
-
-
Re-stringing of conductor (ACSR 6/1/2.59-mm) including binding,hoisting & jumpering etc as reqd
8.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements