Tripura State Electricity Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Tripura State Electricity Corporation Limited - TSECL Tender
Civil And Construction
Eprocure
Opening Date2 Mar 2024
Closing Date8 Mar 2024
Tender Amount₹ 1,43,66,248
Costs
EMD
₹ 2,87,325Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_POWER_47977_1Bid Award Id
ViewTender No
DGM/ED-DMR/23-24/11Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://https://www.tsecl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Stay wire 7/2.5mm
2665
-
-
Stay insulator(LT)
279
-
-
Stay insulator(HT)
254
-
-
100X50x50X6 mm GI Channel
684.43
-
-
75X40X40x6 mm GI Channel
4027.96
-
-
65X65X6 mm GI Angle
5464.55
-
-
ACSR (6/1/2.59 mm) weasel conductor
20.28
-
-
11 KV composit (polymer) Tension (Disc) insulator, 70 KN with all accessories
405
-
-
11 KV composit (polymer) Tension (Disc) fittings, 70 KN with all accessories
405
-
-
11 KV 320 mm polymer composit Pin insulator
528
-
-
Lighting Arrestor 9 KV, 10KA single pole metal oxide gapless type
30
-
-
16KVA, 11/0.433 KV Distribution Transformer
7
-
-
70 sqmm PVC cable for transformer ckt connection
70
-
-
63 Amp Cut Out
14
-
-
11 KV GOS (3-Phase)
10
-
-
11 KV DOF(3-phase)
10
-
-
40 mm dia GI pipe 2.5 mtr long (Make:-TATA/JINDAL)
31
-
-
60 kg salt & 55 kg Charcoal (For 1 pit)
31
-
-
8 SWG GI Wire
1784.37
-
-
GI Barbed wire 12 SWG
1599
-
-
Stay clamp
533
-
-
Bracket Clamp by 50X6mm
1389
-
-
GI Nuts & Bolts i/c washer, ISI markedmachine made(assorted size)
3280
-
-
1.1 KV LT AB cable 1X25+1X16+1X25 sq.mm.
9.6
-
-
Suspension clamp
240
-
-
Dead End clamp
50
-
-
Eye Hook
301
-
-
Cable tie with adjustable locking arrangement
301
-
-
GI pole clamp /Double SS straps for fixing eye hook to 8 mtr ST pole i/c GI N&B/ Strapbuckles.
301
-
-
Pre-insulated mid span jointing sleeves
38
-
-
Insulated Piercing connector
222
-
-
Single Phase LT ABC Distribution box
111
-
-
1.1KV PVC 2.5 sq.mm, Cable (For Service)
7770
-
-
Reel insulator
220
-
-
Danger Plate [L.T]
279
-
-
Danger Plate [H.T]
234
-
-
SCHEDULE-B Errection
-
-
-
Erection of Single pole stucture of 9 mtr GI ST pole i/c excavation of pits in all type of soil, fixing stone pad, concreting, backfilling, fitting and fixing of all accessories (fully dressed) i/c GI febricated item, pin insulators, clamps & other hardware, danger plate, anti climbing device, pole numbering by paint as per technical specifications& approved drawings.
118
-
-
Erection of Double pole stucture of 9 mtr GI ST pole i/c excavation of pits in all type of soil, fixing stone pad, concreting, backfilling, fitting and fixing of all accessories (fully dressed) i/c GI febricated item ( 02 nos brackets for line 01 nos for guarding and 04 nos cross bracket for pole strenthening etc.), insulators, clamps & other hardware, danger plate, anti climbing device, pole numbering by paint and installation of earth pipes and pole earthing using GI wire as per technical specifications& approved drawings.
61
-
-
Erection of Double pole stucture of 9 mtr GI ST pole (for Sub-station) i/c excavation of pits in all type of soil, fixing stone pad, concreting, backfilling, fitting and fixing of all accessories (fully dressed) i/c insulators, clamps & other hardware, danger plate, anti climbing device, pole numbering by paint as per technical specifications & approved drawings.
7
-
-
Laying, hoisting & stringing of ACSR (6/1/2.59 mm) Weasel Conductor including binding, jumpering, etc. as reqduired & as per direction of the Engineer-in-Charge.
20.28
-
-
Erection of complete HT/LT Stay set and GI stay wire i/c excavation of stay pit , concreting, installation of all accessories , stay clamp, guy insulator, anchor plate, nuts bolts, turn buckles , stay rod & GI stay wire complete as per technical specification and approved drawings.
533
-
-
Errection 8.00 mtr. Long Steel tubular pole i/c excavation, refilling the pit in complete shape i/c Grouting.
279
-
-
Substation Top & Base bracket 2.8 mt.long 100X50X50X6 mm for Sub-Station bracket (for line & txr base) clamps & nuts bolts
21
-
-
Substation Base bracket 0.6 mt.long 100X50X50X6 mm for Sub-Station bracket ( for Txr base) clamps & nuts bolts
14
-
-
Substation GOS & DOF bracket 2.8 mt.long 75X40X40X6 mm for Sub-Station bracket (for GOS & DOF) clamps & nuts bolts
43
-
-
Substation Handle bracket 2.8 mt.long 65X65X6 mm MS angle for Sub-Station bracket (for GOS Handle) clamps & nuts bolts
10
-
-
Substation Guard bracket 2.8 mt.long 65X65X6 mm MS angle for Sub-Station bracket i/c clamps & nuts bolts
10
-
-
DP bracket 2.2 mt.long 75X40X40X6 mm ( for 11KV line)
6
-
-
DP guard bracket 2.5 mt.long 65x65X6 mm ( for 11KV line)
3
-
-
Lighting Arrestor 9 KV, 10KA single pole metal oxide gapless type i/c necessary connection complete as required.
30
-
-
installation/positioning of 16KVA, 11/0.433 KV Distribution Transformer on pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
7
-
-
Earthing with GI pipe 2.5 mtr long and 40 mm dia i/c excavation , refilling with alternate layer of salt & charcoal as per drawing alongwith complete connection as required
31
-
-
11 KV GOS (3-Phase) i/c necessary connection complete as required.
10
-
-
11 KV DOF(3-phase) i/c necessary connection complete as required.
10
-
-
Laying & stringning of 8 SWG GI Wire i/c hoisting & binding, GI eye bolt, GI Turn Buckle etc. with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect
14.48
-
-
Cradle Guard for HT by 8 SWG GI wire and Erection of 11 KV protective guarding by GI wire 8 SWG as per technical specification, across road/river/telecom line etc. in horizontal formation complete
2546
-
-
Positioning of cable drum removing of cable from drum and laying , stringning ,hoisting & drawing of AB cable 1.1 KV LT AB cable 1X25+1X16+1X25 sq.mm. alongwith Pre-insulated mid span jointing sleeves i/c installation of all accessories as per direction of Engg. In charge
9600
-
-
Fitting fixing of service main 1/3 phase distribution box of on steel pole with the help of pole brackets or steel straps & buckles as per direction of engg in charge.
111
-
-
Erection & fitting fixing of insulated suspension clamp i/c pole clamp , eye hook for cable massenger of 1.1 KV grade on steel pole with the help of pole brackets or steel straps & buckles as per direction of engg in charge.
240
-
-
Erection & fitting fixing of insulated Dead end enchoring clamp i/c pole clamp , eye hook for cable massenger of 1.1 KV grade on steel pole with the help of pole brackets or steel straps & buckles as per direction of engg in charge.
50
-
-
Erection & fitting fixing of insulation piercing connectors (IPC) all sizes i/c connection from main cable to distribution box, TEE- off line as per direction of engg in charge.
222
-
-
Providing protective Sub-Station fencing of size 2.5X3.5 mtr and 1.5 mtr height. Fencing by 75X25 mm wire mesh, 10 nos MS angle post (50X50X6mm) of height 2 mtr, horizontal bar 4X2.5 mtr, 2X3.5 mtr, 2x2 mtr, 2X1.5 mtr and 10X1.5 mtr vertical bar of MS flat (35X6mm). a single part of MS grill door of size 1.5 X 1.2 mtr along with necessary locking arrangement i/c grouting and painting by aluminium paint over red oxide priming of approve quality as required as per technical specification i/c supply of all materials.
7
-
-
Febrication of cross arms by MS Channel/ MS Angle as per specification
10176.94
-
-
Tree Trimming, Cutting & clearing Right of way
11
-
-
Providing 1 ph Service Connection with laying PVC cable from pole to premises upto 35 mtr in length supported by GI wire, Reel insulator i/c fitting fixing of energy meter.
111
-
-
Supply & erection GI wire 8 SWG for coil earthing
111
-
-
Supply & erection 16 Amp Cut out
111
-
-
Supply & erection 16 Amp ICDP main swith
111
-
-
Supply & erection Wooden plank
111
-
-
Supply & erection 9 Wt. LED Bulb
111
-
-
Supply & erection Angle holder
111
-
-
Supply & erection 5 Amps plug (3 pin)
111
-
-
Supply & erection 4"x4" Board (switch )
111
-
-
Supply & erection Piano switch 5 Amp
111
-
-
Supply & erection Single core 1.5 Sq.mm. Cupper wire
1110
-
-
Supply & erection of screw of assaorted size
2220
-
-
Supply and erection of PVC pipe 20mm dia. as per ISI
555
-
-
Supply & erection Wooden board (8"x12") for Main switch & Meter
222
-
-