BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Costs
EMD
₹ 31,746Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Replacement Of Existing Damaged Spun Pipe Culvert To Rcc Box Cell At Ch. 1.20 Km On K-a Road To Mendi Road During The Year 2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPWD_53261_1Tender No
27/EE/PWD(R and B)/KMP/DIV/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.tripura.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundation complete including formwork as per drawing & MoRD technical specifications Clauses 802,900,1202 & 1203. (including centring, shuttering, staging etc. but excluding reinforcement ).I. P.C.C grade M10 (using jhama brick aggregate).i) Nominal mix 1:3:6
7.86
62077
7897.9
... More
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawing & MoRD technical specifications Clauses 802,803,900,1202 & 1203. (including centring,shuttering,staging etc. but excluding reinforcement ).IV. R.C.C grade 20
4
40733
10183.4
... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawing & MoRD technical specifications clauses 1000 & 1202.
0.48
32703
68131.5
... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawing & MoRD technical specifications Clauses 802,804, 805, 806, 807, 900,1202 & 1204. (including centring,shuttering,staging etc. but excluding reinforcement ).VI. R.C.C grade M-25.i) Upto 5 m height
8
89818
11227.3
... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ cold twisted deformed steel bar in substructure complete as per drawing & MoRD technical specifications clauses 1002,1005,1010 and 1202.
0.96
65579
68312.2
... More
Brick masonary work in cement mortar in foundation complete excepting pointing & plastering as per drawing & MoRD technical specification Clauses 600,1202 & 1203.II) Brick masonry in 1:4 cement mortar
32.4
275325
8497.7
... More
Brick masonary work in cement mortar in substructure complete excepting pointing & plastering as per drawing & MoRD technical specification Clauses 602, 603, 604,1202 and 1204.II) Brick masonry in 1:4 cement mortar
30.6
273031
8922.6
... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.
50
17420
348.4
... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.
22.12
107726
4870.1
... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specification Clauses 800, 900, 1205.4 & 1205.5. (including centering, shuttering, staging etc. but excluding reinforcement).II) R.C.C grade M-25.1) For height upto 5 m.
4.36
53240
12211.1
... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in superstructure complete as per drawings & MoRD technical specification Clauses 1002, 1010 and 1202.
0.53
36920
69660.7
... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing & MoRD technical specification Clauses 800 & 1206.3 (including centering,shuttering,staging etc. and reinforcement.)
1.01
16368
16206.6
... More
Construction of RCC railing of M 25 grade in cast-in-situ with 20 mm nomonal size aggregate, true to line & grade, tolarance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not exceed 2000 mm including reinforcement as per drawing and MoRD technical specifications Clauses 800,0900 and 1208.3 (including centering, shuttering, staging,etc. and reinforcement).
4
13774
3443.5
... More
Providing and fixing in position drainage spouts complete as per drawing & MoRD technical specifications Clause 1209.
4
6715
1678.9
... More
Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Technical Specification Clause 301.5.
60
12336
205.6
... More
Brick edging laid in full brick width.Providing and laying brick edging on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412.
40
10094
252.36
... More
Flat Brick soling.Providing and laying flat brick soling layer on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412.
75
43432
579.1
... More
WBM Grading 2.Providing, laying, spreading and compacting jhama brick aggregates of specified size to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 KN in stages to proper grade and camber, applying and brooming, binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Technical Specification Clause 405.
A) By Manual Means
5.63
43975
7810.93
... More
WBM Grading 3.Providing, laying, spreading and compacting jhama brick aggregates of specified size to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 KN in stages to proper grade and camber, applying and brooming, binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per MoRD Technical Specification Clause 405.
A) By Manual Means
5.63
44190
7849.13
... More
Tack Coat using hot straight run itumen of grad VG-30 on W.B.M.Providing & applying tack coat using hot straight run bitumen of grade VG-30, in/c heating the bitumen, spraying the bitumen, cleaning & preparing the existing road surface as per specifications: on W.B.M. @ 0.75 kg/ Sqm.
75
4183
55.78
... More
20 mm thick Open-Graded Premix Carpet using
Bituminous (viscocity grade/ modified bitumen)
Binder.Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using viscocity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508.Case-II: By Mechanical Means.(I) Bitumen of VG-30.
75
27442
365.9
... More
Seal Coat.Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 510
A) By Manual Means.
75
5897
78.63
... More
Plastering with cement mortar (1:4) 12 mm thick on brickwork/ C.C. work including a finishing coat of neat cement punning with 2.75 kg of cement per sqm in substructure as per MoRD technical specification Clauses 613.4 & 1204.
14.6
3279
224.6
... More
Providing and laying of apron with cement concrete blocks of size as per Table 1300.1 cast-in-situ and made with nominal mix of M-15 grade cement concrete (using jhama brick aggregate)as per drawing and MoRD technical specification Clause 1301 (rate includes preparation of bed, nominal surface re-inforcement and filling of granular material in recesses between blocks).
27.95
266559
9537
... More
Painting Two Coats on New Concrete Surfaces.Painting two coats including primer coat after filling the surface with synthetic enamal paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Technical Specification Clauses 1701.
14.6
1413
96.8