Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date21 Aug 2024
Closing Date11 Sep 2024
Tender Amount₹ 4,04,44,408 
Notes
Download

Costs

Summary

Improvement Of Road From Sonamura Boxanagar Road To Adampur And Road From Sonamura Boxanagar Road To Dudhpukur Para (l-2.174 Km) Under Boxanagar Assembly Constituency Under Scheme For Special Assistance To States For Capital Investment For 2024-25.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding whenever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and upto a lead of 1000 m as per MoRD Technical Specification Clause 202. (I) By Manual Means (B) Cement Concrete

0.94

614

653.4

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding whenever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and upto a lead of 1000 m as per MoRD Technical Specification Clause 202. (I) By Manual Means C) Reinforced Cement Concrete

3.74

6821

1824

... More
Dismantling Brick/Tile Work as per MoRD Technical Specification No. 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry including disposal of unserviceable material and stacking the serviceable material with all lift and upto a lead of 1000 m as per MoRD Technical Specification Clause 202. B) Cement mortar

13.26

5626

424.3

... More
Removing all types of Hume pipes. Removing all types of Hume pipes and stacking within a lead of 1000 m excluding Earthwork and Dismantling of Masonry Works as per MoRD Technical Specification Clause 202 . (B) bove 600 mm to 900 mm dia Hume pipe

48

19296

402

... More
SH:Earthwork

-

-

-

... More
Compacting Original Ground (i) Compacting original ground supporting embankment Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per MoRD Technical Specification Clause 301.4.1.

252.38

5804

23

... More
Compacting Original Ground (ii) Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per MoRD Technical Specification Clause 303.5.2.

1128.45

34304

30.4

... More
(iii) Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections and transporting to the embankment location with all lifts and lead upto 1000 m as per MoRD Technical Specification Clause 302.3.

7904.98

348609

44.1

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per MoRD Technical Specification Clause 301.5. A. For spreading beyond 100 m

2458.18

199358

81.1

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site , spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per MoRD Technical Specification Clause 303.1.

1340.62

313436

233.8

... More
SH:Protection Work (Retaining wall & Brick drain)

-

-

-

... More
Excavation for Structures A.Without dewatering. Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I.Ordinary Soil (i) Upto 3 m depth

573.66

262851

458.2

... More
Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200. I.Sand filling

191.22

243170

1271.68

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). I.P.C.C grade M 10 ((using jhama brick aggregate) (I) Nominal mix 1:3:6

113.93

1065700

9353.99

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). (II) P.C.C grade M 15 (using jhama brick aggregate) (i) Nominal mix (1:2.5:5)

795.63

7602332

9555.11

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) VI.R.C.C grade M-25 i) Upto 5 m height

16.57

209940

12669.89

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

379

148643

392.2

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

218.1

1030164

4723.36

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

21.77

2001883

91968.72

... More
SH:Drainage Works

-

-

-

... More
Surface Drains Construction of unlined surface drains of average cross-sectional area 0.40 sqm in ordinary soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3 m and lead of 50 m (average lead 25 m) as per MoRD Technical Specification Clause 307. (i) Surface Drains in Ordinary Soil (B) Mechanical Means

1650

36135

21.9

... More
Road side Pucca Drains Construction of road side pucca drain with M10 (1:3:6 with jhama brick aggregate) to specified lines, grades, levels and dimensions as per approved design and MoRD Technical Specification Clause 307, 1606. Excavated material to be used in embankment at site. (including centering, shuttering, etc. but excluding reinforcement) C.Trapezoidal drain (top clear width 600 mm, bottom clear width 300 mm and clear depth of 600 mm) I.In Ordinary Soil

230

979326

4257.94

... More
Road side Pucca Drains Construction of road side pucca drain with M10 (1:3:6 with jhama brick aggregate) to specified lines, grades, levels and dimensions as per approved design and MoRD Technical Specification Clause 307, 1606. Excavated material to be used in embankment at site. (including centering, shuttering, etc. but excluding reinforcement) D.U shaped drain (top clear width 600 mm, bottom clear width 600 mm and clear depth of 600 mm) (I) In Ordinary Soil

100

490961

4909.61

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II.R.C.C M 25 1.For height upto 5 m

20

274726

13736.31

... More
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.

1.4

131208

93720.42

... More
SH:Miscellaneous Items for roads.

-

-

-

... More
Dismantling of Brick soling Dismantling of brick soling, stacking serviceable materials and unserviceable materials separately with all lifts and upto a lead of 500 m by manual means as per MoRD Technical Specification Clause 202.

143.93

123664

859.2

... More
Labour charge for Breaking of jhama bats/ jhama bricks/ 1st class bricks. Breaking of jhama bats/ jhama bricks /1st class bricks (including bigger lumps) into metal/chips /aggregates and stacking serviceable materials and unserviceable materials separately as per direction of the Engineer-in-charge with all lifts and upto a lead of 100 m. ii.Required sizes for GSB (53 mm to 0.075 mm) as per MoRD Technical Specification Clause 401.

71.96

109392

1520.1

... More
Charge for construction of Granular Sub-base Charge for Construction of granular sub-base by providing well graded material (53 mm to 0.075 mm Jhama Brick Aggregate , Grading-I), spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401. (excluding the cost of jhama aggregate which are available at site only). (i) For Grading - I Material (A) By Mix in Place Method

71.96

20135

279.8

... More
SH:Granular Sub-bases, Bases (Non-Bituminous) and Shoulders

-

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1) using Jhama Brick Aggregate (A) By Mix in Place Method Construction of granular sub-base by providing well graded material (Jhama Brick Aggregate, Grading-I, as per Table 400.1, spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401. (i) For Grading - I Material (jhama brick aggreate)

922.5

4482353

4858.92

... More
Water Bound Macadam Sub-Base / Base using Jhama Brick Aggragate 1) WBM Grading - 2 Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 2 as per MoRD Technical Specification Clause 405. (A) By Manual Means

609.98

4645186

7615.31

... More
Water Bound Macadam Sub-Base / Base using Jhama Brick Aggragate 2) WBM Grading - 3 Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 3 as per MoRD Technical Specification Clause 405. (A) By Manual Means

586.52

4488936

7653.51

... More
SH: Bases and Surface Courses (Bituminous)

-

-

-

... More
Prime Coat ii) Medium porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.20 kg/sqm using mechanical means as per MoRD Technical Specification Clause 502.

7820.27

718291

91.85

... More
Tack Coat (iii) Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface treated with primer & cleaned with Hydraulic broom as per MoRD Technical Specification Clause 503.

7894.69

186709

23.65

... More
20 mm thick Open-Graded Premix Carpet using Bitumen Emulsion as per MoRD Technical Specification Clause 508.2 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using bitumen emulsion to required line, grade and level to serve as wearing course on a previously prepared base , including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 KN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508.2.

7894.69

2946929

373.28

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 510. A. By Manual Means Case - II : Type B (I) Bitumen of VG-30

7894.69

741864

93.97

... More
SH:Traffic Sign, Markings and other Appurtenances

-

-

-

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A.Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. i) with 900 mm equilateral triangle aluminium sheeting

44

164288

3733.83

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A.Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. iii) with 600 mm circular aluminium sheeting

74

269945

3647.91

... More
Direction and Place Identification signs upto 0.9 sqm size board (using jhama brick aggregate in CC / PCC) (B) Semi Reflective Traffic Signs Providing and erecting and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. sheet duly stove enameled paint in white colour in front and gray colour on back with red reflective border of 70 mm width and required message, letters and figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47 mm x 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm bellow ground level as per approved drawings and MoRD Technical Specification Clause 1701.

4

18296

4574.1

... More
Kilometre Stone (with RCC M15 grade using jhama brick aggregate) Reinforced cement concrete M15 grade (using jhama brick aggregate) kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and MoRD Technical Specification Clause 1703. ii) Ordinary Kilometre Stone (precast)

3

11049

3683.24

... More
Boundary Pillar (with PCC M15 grade using jhama brick aggregate and reinforcement) Plain cement concrete M15 grade (using jhama brick aggregate and reinforcement) boundary pillar / local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Technical Specification Clause 1704.

42

37038

881.88

... More
Construction of RCC guide posts of 250 mm dia and total 600 mm long,(300 mm below GL) M15 grade (with jhama brick aggregate) cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and MoRD Technical Specification Clause 1401.6. A.In Ordinary Soil

466

251281

539.23

... More
Road marking strips (retro-reflective) of specified shade/ colour using Hot Applied Thermoplastic material with Reflectorising Glass Beads on Bituminous Surface Providing and applying 2.5 mm thick thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material including reflectorising glass beads @ 250 gms per sqm area by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater including cost of cleaning the road surface of all dirt, seals, oil, grease and foreign material etc, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes as per MoRT&H Technical Specification Clause 803.

402.8

290781

721.9

... More
Providing and Fixing 'Citizens' Information Board' of the Project(with CC structure) Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing with CC structure made with M-15 of Size 1150 mm in length, 300 mm in thickness and 2450 mm in height all above G.L. with foundation with M-15 concrete of size 1150 mm x 600 mm x 750 mm , 750 mm below ground level with skin reinforcemet with 8 mm dia TMT bars @ 200 cm C/C from bottom of the structure. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of structure will be painted with primer and two coats of epoxy paint as per drawing and MoRD technical specification Clause 1701 and Annexure 1700.1 A.Board 'A'

1

23160

23160.31

... More
Providing and Fixing 'Citizens' Information Board' of the Project(with CC structure) Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing with CC structure made with M-15 of Size 1150 mm in length, 300 mm in thickness and 2450 mm in height all above G.L. with foundation with M-15 concrete of size 1150 mm x 600 mm x 750 mm , 750 mm below ground level with skin reinforcemet with 8 mm dia TMT bars @ 200 cm C/C from bottom of the structure. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of structure will be painted with primer and two coats of epoxy paint as per drawing and MoRD technical specification Clause 1701 and Annexure 1700.1 B.Board 'B'

1

22374

22374.11

... More
SH:Box Culvert

-

-

-

... More
Excavation for Structures A.Without dewatering. Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3 m depth

244.32

111947

458.2

... More
Backfilling behind abutment, wing wall & return wall complete as per drawings & MoRD technical specification Clause 1204.3.8. I) Sandy material

81.44

138104

1695.78

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I.P.C.C grade M 10 ((using jhama brick aggregate) (i) Nominal mix 1:3:6

36.16

338240

9353.99

... More
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). II.P.C.C grade M 15 (i) Nominal mix (1:2.5:5)

171.61

1832999

10681.19

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) VI.R.C.C grade M-25 i) upto 5 m height

64.35

815307

12669.89

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

9.16

842433

91968.72

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II.R.C.C M 25 1.For height upto 5 m

30.99

425688

13736.31

... More
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.

3.72

348639

93720.42

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

99.18

468462

4723.36

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

147.62

57896

392.2

... More
Providing and fixing in position Drainage spouts complete as per drawing & MoRD technical specifications Clause 1209.

24

48168

2007



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.