Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date3 Jan 2024
Closing Date24 Jan 2024
Tender Amount₹ 5,48,83,684 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SH:Protection Work

-

-

-

... More
Excavation for Structures B.With dewatering. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, dewatering, construction of shoring, shuttering & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I.Ordinary Soil (i) Upto 3 m depth

614.75

281678

458.2

... More
Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200. I.Sand filling

204.92

275793

1345.86

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I.P.C.C grade M 10 ((using jhama brick aggregate) (i) Nominal mix 1:3:6

92.78

876977

9452.23

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) II.P.C.C grade M 15 (using jhama brick aggregate) (i) Nominal mix (1:2.5:5)

1055.86

10186398

9647.49

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

260

101972

392.2

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

236.4

1142516

4832.98

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

14.89

1368560

91911.39

... More
SH: Drainage Works

-

-

-

... More
Surface Drains Construction of unlined surface drains of average cross-sectional area 0.40 sqm in ordinary soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3 m and lead of 50 m (average lead 25 m) as per MoRD Technical Specification Clause 307. (i) Surface Drains in Ordinary Soil (B) Mechanical Means

3670

80373

21.9

... More
Road side Pucca Drains Construction of road side pucca drain with M10 (1:3:6 with jhama brick aggregate) to specified lines, grades, levels and dimensions as per approved design and MoRD Technical Specification Clause 307, 1606. Excavated material to be used in embankment at site. (including centering, shuttering, etc. but excluding reinforcement) C.Trapezoidal drain (top clear width 600 mm, bottom clear width 300 mm and clear depth of 600 mm) I.In Ordinary Soil

580

2486083

4286.35

... More
SH: Bases and Surface Courses (Bituminous)

-

-

-

... More
Tack Coat (iii) Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface treated with primer & cleaned with Hydraulic broom as per MoRD Technical Specification Clause 503.

51187.5

1206489

23.57

... More
25 mm thick Open-Graded Premix Carpet using Bituminous (Viscosity grade/ modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 25 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508. Case - II By Mechanical Means (I) Bitumen of VG-30

51187.5

21139925

412.99

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 510. A.By Manual Means Case - II : Type B (I) Bitumen of VG-30

51187.5

4749688

92.79

... More
SH:Traffic Sign, Markings and other Appurtenances

-

-

-

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A.Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. i) with 900 mm equilateral triangle aluminium sheeting

186

696311

3743.61

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A.Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. iii) with 600 mm circular aluminium sheeting

192

701882

3655.64

... More
Kilometre Stone (with RCC M15 grade using jhama brick aggregate) Reinforced cement concrete M15 grade (using jhama brick aggregate) kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and MoRD Technical Specification Clause 1703. ii) Ordinary Kilometre Stone(precast)

14

51819

3701.4

... More
Boundary Pillar (with PCC M15 grade using jhama brick aggregate and reinforcement) Plain cement concrete M15 grade (using jhama brick aggregate and reinforcement) boundary pillar / local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Technical Specification Clause 1704.

174

153704

883.36

... More
Construction of RCC guide posts of 250 mm dia and total 600 mm long,(300 mm below GL) M15 grade (with jhama brick aggregate) cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and MoRD Technical Specification Clause 1401.6. A.In Ordinary Soil

1014

548736

541.16

... More
Road marking strips (retro-reflective) of specified shade/ colour using Hot Applied Thermoplastic material with Reflectorising Glass Beads on Bituminous Surface Providing and applying 2.5 mm thick thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material including reflectorising glass beads @ 250 gms per sqm area by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater including cost of cleaning the road surface of all dirt, seals, oil, grease and foreign material etc, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes as per MoRT&H Technical Specification Clause 803.

2639

1905094

721.9

... More
SH:Box Culvert

-

-

-

... More
Excavation for Structures B.With dewatering. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, dewatering, construction of shoring, shuttering & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I.Ordinary Soil (i) Upto 3 m depth

304.25

139407

458.2

... More
Backfilling behind abutment, wing wall & return wall complete as per drawings & MoRD technical specification Clause 1204.3.8. I) Sandy material

101.42

179509

1769.96

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I.P.C.C grade M 10 ((using jhama brick aggregate) (i) Nominal mix 1:3:6

43.5

411172

9452.23

... More
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). II.P.C.C grade M 15 (i) Nominal mix (1:2.5:5)

245.85

2606622

10602.49

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) VI.R.C.C grade M-25 i) upto 5 m height

66.57

838704

12598.83

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

10.57

971503

91911.39

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II.R.C.C M 25 1.For height upto 5 m

26.65

364198

13665.99

... More
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.

3.2

299721

93663.09

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

92.35

446325

4832.98

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

155.38

60940

392.2

... More
Providing and fixing in position Drainage spouts complete as per drawing & MoRD technical specifications Clause 1209.

14

28098

2007

... More
Brick soling i) Brick on edge soling Providing and laying brick on edge soling layer on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with sand, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412.

39.2

38874

991.7

... More
Brick masonry work in cement mortar in substructure complete excepting pointing & plastering, as per drawing & MoRD technical specification Clauses 602, 603, 604, 1202 and 1204. II.In 1:4 cement mortar

14.5

148343

10230.58

... More
Reinforced Cement Concrete M 25 grade approach slab including reinforcement & formwork complete as per drawing & MoRD technical specifications Clauses 800 & 1211 (including centering, shuttering, staging etc. and reinforcement)

12.6

231188

18348.27

... More
Construction of R.C.C railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line & grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm including reinforcement as per drawing and MoRD technical specifications Clauses 800, 900 and 1208.3 (including centering, shuttering, staging etc. and reinforcement).

9.8

41661

4251.2



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.