Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Public Works Department - PWD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date22 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 22,51,617 
Notes
Download

Costs

Summary

Maintenance And Repairing Of Pipe Line Leakage, Washing, Mtc Of Hydrant Including Of Sluice Valve Chamber For Better Functioning Of Flood Affected Water Supply Schemes At Different Locations At Kalachara Sector Under Satchand Block During 2024-2025.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
iii) 140 mm OD

75

689

51683

... More
Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge.

-

-

-

... More
i) 90 mm dia

900

336

303120

... More
ii) 110 mm dia

600

360

216000

... More
iii) 140 mm dia

240

394

94752

... More
Providing and fixing in position 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide sufficiently long at the top and bottom respectively, channels & with bolts, nuts, rivets, locking arrangement, stoppers, handles, hold fast including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.

5.04

5617

28312

... More
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 11.1.2 0.63mm thick with zinc coating not less than 275gm/m2 sqm

31.5

1205

37970

... More
Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge

2

9372

18745

... More
Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge.

-

-

-

... More
i) 6.0 sqmm

2

446

893

... More
ii) 10.0 sqmm

2

589

1178

... More
Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge

2

1135

2271

... More
Providing and fitting fixing of moving iron type, Range 0-100/0200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge

2

1964

3930

... More
Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. i. 35 HP/26 kw Relay range within 20-32 + 10%

2

27556

55113

... More
Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge i. 100 amps

2

10274

20550

... More
Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) , laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge. i. for 3-phase connection with 4.00 mtr. Long G.I. pipe

2

23655

47312

... More
Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope 1 in 200) including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A. For UPVC pipes in new work a). In all kinds of soil

-

-

-

... More
i. For pipes not exceeding 90 mm dia

1980

87

173448

... More
ii). For pipes exceeding 90 mm dia but not exceeding 300 mm dia

342

106

36389

... More
B). For G.I. / C.I. / D.I. pipes in new work a). In all kinds of soil ii). For pipes exceeding 90 mm dia but not exceeding 300 mm dia

100

133

13380

... More
Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. A). Class - 3 ( working pressure 6.0 kg / cm2)

-

-

-

... More
i) 90 mm OD

600

271

162840

... More
ii) 110 mm OD

240

372

89304

... More
iii) 140 mm OD

102

612

62506

... More
Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately).

-

-

-

... More
i. 15 mm dia

780

57

44694

... More
ii. 20 mm dia

400

65

26360

... More
iii)32 mm dia

200

83

16660

... More
Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. A) PN - 1.6

-

-

-

... More
ii). 100 mm dia.

1

5561

5561

... More
iii). 125 mm dia.

2

6662

13324

... More
iv). 150 mm dia.

4

8238

32954

... More
Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. b) 110 X 110 mm dia

2

580

1161

... More
Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.

-

-

-

... More
a) 90 mm dia

3

148

446

... More
b) 110 mm dia

2

174

349

... More
Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.

-

-

-

... More
a) 90 mm dia

5

298

1494

... More
b) 110 mm dia

5

356

1782

... More
c) 140 mm dia

5

466

2334

... More
Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.

-

-

-

... More
i). 110 x 90 mm dia

5

321

1606

... More
ii). 140 x 110 mm dia

5

426

2134

... More
iii). 140 x 90 mm dia

5

395

1979

... More
Providing and fixing brass ferrule with C.I. cover conforming to IS :2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge. ii) 15 mm nominal bore

40

382

15308

... More
Constructing masonry Chamber 90 x 90 x 100 cm, inside with 75 class designation brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 190 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 brick aggregate 1st class 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. A). With Second class bricks

4

20432

81732

... More
Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia

40

78

3144

... More
Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia

40

131

5240

... More
Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. B). by manual means

28

619

17340

... More
Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. A). External work

-

-

-

... More
ii). 100 mm dia. nominal bore

48

1466

70387

... More
iii). 150 mm dia. nominal bore

48

1931

92712

... More
Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia.

40

104

4192

... More
Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge. i) 15 mm dia PVC /plastic bib cock

40

119

4776

... More
Providing and fixing G.I. Nipple of medium class as per chapter 20 of CPWD specification and direction of the Engineer - in - charge iii) 15 mm dia 225 mm long

40

74

2984

... More
Providing and fixing in position Precast RCC hydrant post of size 100 mm dia ( made with reinforced cement concrete 1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded well burnt brick aggregate 1st class 12 mm nominal size) and steel reinforcement ( TMT bars )3 nos 8 mm dia 950 mm long and 7 Nos 6 mm dia ties including plastering the surface with 6 mm thick cement mortar 1 : 3 ( 1 cement: 3 sand ) finished with a floating coat of neat cement including providing & embedding 15 mm dia G.I. pipe (medium class as per IS : 1239 ) with necessary GI fittings like 2 Nos elbow, 1 no socket, 2 nos nipple 225 mm long and fitting fixing of PVC bib cock with GI socket complete with all earth work required including refilling etc. complete as per approved drawing ( Drawing No-06/CE/ACE/P&DU/DWS/2022-23), specification and direction of Engineer-in-charge.

27

1418

38286

... More
Providing and fixing in position Precast RCC platform of size 900 mm x 900 mm x100 mm with curb of size 75 x 75 mm keping an opening of 200 mm wide for surface drain of 60 cm length of size (200 mmx150 mm) in a suitable place for draining out of grey water (made with cement concrete 1:1.5:3 (1 cement: 1.5 sand: 3 graded well burnt brick aggregate 12 mm nominal size) and steel reinforcement(TMT bars ) 6 nos. 8 mm dia in both direction including plastering the exposed surface with 6 mm thick cement mortar 1:3 (1 cement :3 sand) for platform &12 mm cement plaster(1:4) (1 cement :4 sand) for surface drain finished with a floating coat of neat cement complete with all earth work required including refilling etc. complete as per approved drawing (Drawing No-06/CE/ACE/P&DU/DWS/2022-23), specification and direction of Engineer-in-charge.

27

2295

61965

... More
Dismantling old C.I. / D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as per CPWD specification and direction of the Engineer - in - charge.

-

-

-

... More
ii) 100 mm dia

90

455

41022

... More
iv) 150 mm dia

200

469

93960



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.