Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date13 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 4,42,69,528 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(iii) Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections and transporting to the embankment location with all lifts and lead upto 1000 m as per MoRD Technical Specification Clause 302.3.

11059.74

44

487734.53

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per MoRD Technical Specification Clause 301.5. A. For spreading beyond 100 m

5335.26

81

432689.59

... More
SH:Protection Work (Toe Wall)

-

-

-

... More
Excavation for Structures A.Without dewatering. Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I.Ordinary Soil (i) Upto 3 m depth

412.1

458

188824.22

... More
Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200. I.Sand filling

18.65

1299

24235.68

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 10 (using jhama brick aggregate) (i) Nominal mix 1:3:6

50.73

9313

472476.9

... More
Brick masonry work in cement mortar in substructure complete excepting pointing & plastering, as per drawing & MoRD technical specification Clauses 602, 603, 604, 1202 and 1204. II. In 1:4 cement mortar

154.29

10111

1560126.48

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) VI. R.C.C grade M-25 i) upto 5 m height

129.61

12605

1633802.74

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

186

392

72949.2

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

233.95

4686

1096481.54

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

16.29

91867

1496518.15

... More
SH: Drainage Works

-

-

-

... More
Excavation for Structures A.Without dewatering. Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I.Ordinary Soil (i) Upto 3 m depth

535.57

458

245398.17

... More
Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200. I.Sand filling

57.98

1299

75345.01

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 10 (using jhama brick aggregate) (i) Nominal mix 1:3:6

86.97

9313

810000.31

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 15 (1:2.5:5 Nominal mix)

70.88

11090

786127.95

... More
Brick masonry work in cement mortar in substructure complete excepting pointing & plastering, as per drawing & MoRD technical specification Clauses 602, 603, 604, 1202 and 1204. II. In 1:4 cement mortar

88.13

10111

891139.71

... More
Plastering with cement mortar (1:4) 15 mm thick on brickwork in substructure as per MoRD technical specification Clauses 613.4 & 1204.

855.25

228

195356.21

... More
Plastering with cement mortar (1:4) 12 mm thick on brickwork/ C.C. work including a finishing coat of neat cement punning with 2.75 kg of cement per sqm in substructure as per MoRD technical specification Clauses 613.4 & 1204.

1247.5

233

291865.1

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

5.67

93618

530819.67

... More
SH:Miscellaneous Items for roads.

-

-

-

... More
Dismantling of Brick soling Dismantling of brick soling, stacking serviceable materials and unserviceable materials separately with all lifts and upto a lead of 500 m by manual means as per MoRD Technical Specification Clause 202.

367.5

859

315756

... More
Labour charge for Breaking of jhama bats/ jhama bricks/ 1st class bricks. Breaking of jhama bats/ jhama bricks /1st class bricks (including bigger lumps) into metal/chips /aggregates and stacking serviceable materials and unserviceable materials separately as per direction of the Engineer-in-charge with all lifts and upto a lead of 100 m. ii.Required sizes for GSB (53 mm to 0.075 mm) as per MoRD Technical Specification Clause 401.

183.75

1520

279318.38

... More
Charge for construction of Granular Sub-base Charge for Construction of granular sub-base by providing well graded material (53 mm to 0.075 mm Jhama Brick Aggregate , Grading-I), spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401. (excluding the cost of jhama aggregate which are available at site only). (i) For Grading - I Material (A) By Mix in Place Method

183.75

279

51413.25

... More
SH:Granular Sub-bases, Bases (Non-Bituminous) and Shoulders

-

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1) using Jhama Brick Aggregate (A) By Mix in Place Method Construction of granular sub-base by providing well graded material (Jhama Brick Aggregate, Grading-I, as per Table 400.1, spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401. (i) For Grading - I Material (jhama brick aggreate)

1060.5

4840

5133371.46

... More
Water Bound Macadam Sub-Base / Base using Jhama Brick Aggragate 1) WBM Grading 2 Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 2 as per MoRD Technical Specification Clause 405. (A) By Manual Means

893.31

7570

6763062.41

... More
Water Bound Macadam Sub-Base / Base 2) WBM Grading 3 Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 3 as per MoRD Technical Specification Clause 405. (A) By Manual Means

964.69

7606

7338078.48

... More
SH: Bases and Surface Courses (Bituminous)

-

-

-

... More
Prime Coat (i) Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.00 kg/sqm using mechanical means as per MoRD Technical Specification Clause 502.

12862.5

73

947966.25

... More
Tack Coat (iii) Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface treated with primer & cleaned with Hydraulic broom as per MoRD Technical Specification Clause 503.

12862.5

23

302140.13

... More
25 mm thick Open-Graded Premix Carpet using Bituminous (Viscosity grade/ modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 25 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508. Case - II By Mechanical Means (I) Bitumen of VG-30

12862.5

410

5277869.63

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 510. A.By Manual Means Case - IV : Type D (I) Bitumen of VG-30

12862.5

78

1010606.63

... More
SH:Traffic Sign, Markings and other Appurtenances

-

-

-

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A.Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. i) with 900 mm equilateral triangle aluminium sheeting

9

3744

33700.86

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A.Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. iii) with 600 mm circular aluminium sheeting

7

3659

25613.63

... More
Direction and Place Identification signs upto 0.9 sqm size board (using jhama brick aggregate in CC / PCC) B)Semi Reflective Traffic Signs Providing and erecting and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. sheet duly stove enameled paint in white colour in front and gray colour on back with red reflective border of 70 mm width and required message, letters and figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47 mm x 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm bellow ground level as per approved drawings and MoRD Technical Specification Clause 1701.

4

4608

18433.16

... More
Kilometre Stone (with RCC M15 grade using jhama brick aggregate) Reinforced cement concrete M15 grade (using jhama brick aggregate) kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and MoRD Technical Specification Clause 1703. ii) Ordinary Kilometre Stone(precast)

4

3717

14868.32

... More
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and MoRD Technical Specification Clause 1702.

1050

158

166110

... More
Providing and Fixing 'Citizens' Information Board' of the Project(with CC structure) Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing with CC structure made with M-15 of Size 1150 mm in length, 300 mm in thickness and 2450 mm in height all above G.L. with foundation with M-15 concrete of size 1150 mm x 600 mm x 750 mm , 750 mm below ground level with skin reinforcemet with 8 mm dia TMT bars @ 200 cm C/C from bottom of the structure. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of structure will be painted with primer and two coats of epoxy paint as per drawing and MoRD technical specification Clause 1701 and Annexure 1700.1 A.Board 'A'

2

23073

46146.04

... More
Providing and Fixing 'Citizens' Information Board' of the Project(with CC structure) Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing with CC structure made with M-15 of Size 1150 mm in length, 300 mm in thickness and 2450 mm in height all above G.L. with foundation with M-15 concrete of size 1150 mm x 600 mm x 750 mm , 750 mm below ground level with skin reinforcemet with 8 mm dia TMT bars @ 200 cm C/C from bottom of the structure. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of structure will be painted with primer and two coats of epoxy paint as per drawing and MoRD technical specification Clause 1701 and Annexure 1700.1 B.Board 'B'

2

22286

44573.64

... More
SH:Box Culvert

-

-

-

... More
Excavation for Structures A.Without dewatering. Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I.Ordinary Soil (i) Upto 3 m depth

315.31

458

144475.04

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 10 (using jhama brick aggregate) (i) Nominal mix 1:3:6

40.97

9313

381576.55

... More
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). II.P.C.C grade M 15 (i) Nominal mix (1:2.5:5)

154.93

10500

1626853.31

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) VI.R.C.C grade M-25 i) upto 5 m height

66.72

12605

841062.98

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

10.56

91867

970118.58

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II.R.C.C M 25 1.For height upto 5 m

25.68

13676

351209.95

... More
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.

2.57

93618

240600.8

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

120.87

4686

566495.93

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

91.8

392

36003.96

... More
Providing and fixing in position Drainage spouts complete as per drawing & MoRD technical specifications Clause 1209.

16

2007

32112



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.