Public Works Department Tender

... More
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date20 Feb 2025
Closing Soon6 Mar 2025
Tender Amount₹ 75,69,868 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 10 (using jhama brick aggregate) (i) Nominal mix 1:3:6

74.55

9521

709875.94

... More
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). i) P.C.C grade M20 (1:2:4)(Nominal mix)

57

12067

687858.9

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) i) P.C.C grade M20 (1:2:4)(Nominal mix). a) Upto 5 m height.

83.64

12689

1061371.96

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) A) R.C.C grade M-25 i) Upto 5 m height.

100.93

13617

1374427.38

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

13.96

91870

1282876.03

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II) R.C.C M-25 i) For height upto 5 m .

38.57

14688

566495.65

... More
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.

4.63

93621

433282.34

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

55

392

21571

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

13.82

4882

67473.39

... More
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing & MoRD technical specification Clause 1205.5.7.

6

1524

9146.4

... More
Construction of R.C.C railing of M 25 grade in cast-insitu with 20 mm nominal size aggregate, true to line & grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm including reinforcement as per drawing and MoRD technical specifications Clauses 800, 900 and 1208.3 (including centering, shuttering, staging etc. and reinforcement).

15

4432

66490.35

... More
Providing and laying of apron with cement concrete blocks of size as per Table 1300.1 cast-in-situ and made with nominal mix of M-15 grade cement concrete (using jhama brick aggregate)as per drawing and MoRD technical specification Clause 1301 (rate includes preparation of bed, nominal surface reinforcement and filling of granular material in recesses between blocks).

14.98

9967

149309.85

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawings & MoRD technical specifications Clauses 800 & 1206.3 (including centering, shuttering, staging etc. and reinforcement)

3.54

20519

72722.56

... More
Providing and fixing in position Drainage spouts complete as per drawing & MoRD technical specifications Clause 1209.

10

2007

20070

... More
Plastering with cement mortar (1:4) 12 mm thick on brickwork / C.C. work including a finishing coat of neat cement punning with 2.75 Kg of cement per sqm in substructure as per MoRD technical specification Clauses 613.4 & 1204

73.76

232

17166.16

... More
SUB HEAD - II : EARTH WORK

-

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Technical Specification Clause 301.5.

472.5

245

115951.5

... More
Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per MoRD Technical Specification Clause 303.5.2.

101.25

30

3078

... More
SUB HEAD - III : GRANULAR SUB-BASE(Non-Bituminous)

-

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1) using Jhama Brick Aggregate. (A)By Mix in Place Method Construction of granular sub-base by providing well graded material (Jhama Brick Aggregate, Grading-I, as per Table 400.1, spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401. (i) For Grading - I Material (jhama brick aggreate)

42.75

5035

215275.75

... More
Water Bound Macadam Sub-Base / Base using Jhama Brick Aggragate 1) WBM Grading- 2 Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 2 as per MoRD Technical Specification Clause 405. (A) By Manual Means.

20.53

7817

160510.96

... More
Water Bound Macadam Sub-Base / Base using Jhama Brick Aggragate 1) WBM Grading 3 : Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 3 as per MoRD Technical Specification Clause 405. (A) By manual means

21

7849

164831.31

... More
SUB HEAD -IV : BASES and SURFACE COURSES(Bituminous)

-

-

-

... More
Prime Coat (ii) Medium porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.20 kg/sqm using mechanical means as per MoRD Technical Specification Clause 502.

280

91

25645.2

... More
Tack Coat: (iii)Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface treated with primer & cleaned with Hydraulic broom as per MoRD Technical Specification Clause 503.

280

23

6591.2

... More
20 mm thick Open-Graded Premix Carpet using Bituminous (Viscosity grade/ modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base , including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508. Case - I : By Manual Means (I) Bitumen of VG-30

280

370

103695.2

... More
Seal Coat Providing & laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade & cross fall using type A or B type C or D as per MoRD technical specification clauses 510. A) By Manual Means. Case-iv : Type D ( Premix with fine sand ) I) Bitumen of VG-30

280

79

22148

... More
SUB HEAD - V : MARKING & OTHER ROAD APPURTENANCES

-

-

-

... More
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRD Technical Specification clause 1701.

73.76

130

9640.43

... More
Construction of RCC guide posts of 250 mm dia and total 600 mm long,(300 mm below GL) M15 grade (with jhama brick aggregate) cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and MoRD Technical Specification Clause 1401.6. A. In Ordinary Soil.

60

548

32925

... More
SUB HEAD - VI : SITE CLEARANCE AND DISMANTLING

-

-

-

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding whenever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and upto a lead of 1000 m as per MoRD Technical Specification Clause 202. (II) By Mechanical Means B) Reinforced Cement Concrete

14

1262

17675

... More
Dismantling Brick/Tile Work as per MoRD Technical Specification No. 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry including disposal of unserviceable material and stacking the serviceable material with all lift and upto a lead of 1000 m as per MoRD Technical Specification Clause 202. B) Cement mortar

9.34

424

3960.84



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.